ML18086A576

From kanterella
Jump to navigation Jump to search
Forwards LER 81-012/03L-0
Date released: 11/29/2018 Download: ML18086A576


LER 81-012/03L-0:on 810427,during Surveillance Procedure Sp(O) 4.6.1.3 on Containment Air Lock,Leak Rate Exceeded Tech Specs.Caused by Inability of Inner Door Seals to Maintain Test Pressure.Seals Replaced
ML18086A577
Person / Time
Site: Salem PSEG icon.png
Issue date: 05/22/1981
From: Espey J
Public Service Enterprise Group
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
References
Download: ML18086A577 (1)
Forwards LER 81-012/03L-0
ML18086A575
Person / Time
Site: Salem PSEG icon.png
Issue date: 05/22/1981
From: Uderitz R
Public Service Enterprise Group
To: GRIER B H
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
References
Download: ML18086A575 (2)