ML18086A480

From kanterella
Jump to navigation Jump to search
Forwards LER 81-018/03X-1.Detailed Event Analysis Encl
Date released: 11/29/2018 Download: ML18086A480


LER 81-018/03X-1:on 810214,diesel Generator 1A Was Declared Inoperable Due to Cooling Water Leak.Caused by Cracked & Leaking Nipple Connecting Jacket Water Valve 1DA45A & Jacket Water Pipe.Nipple Replaced
ML18086A481
Person / Time
Site: Salem 
Issue date: 05/04/1981
From: Steele W
Public Service Enterprise Group
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
References
Download: ML18086A481 (1)
Forwards LER 81-018/03X-1.Detailed Event Analysis Encl
ML18086A479
Person / Time
Site: Salem 
Issue date: 05/04/1981
From: Uderitz R
Public Service Enterprise Group
To: GRIER B H
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
References
Download: ML18086A479 (2)