Public Service Electric and Gas Company 80 Park Plaza Newark, N.J. 07101 Phone 201/430-7000 February 4; 1981 Director of Nuclear Reactor Regulation U.S. Nuclear Regulatory Com.mission Washington~ D.C.

20555 Attention~

Mr. Frank J. Miraglia, Chief Licensing Branch 3 Division of Licensing Gentlemen:

PROPOSED TECHNICAL SPECIFICATIONS HYDRAULIC SNUBBERS NO. 2 UNIT SALEM NUCLEAR GENERATING STATION DOCKET NO. 50-311 The NRC's proposed full power technical specifications for Salem 2 concerning hydraulic snubbers allows for exemptions from functional testing for individual hydraulic snubbers that are "especially difficult to remove" or in "high radia-tion zones during shutdown" if a justifiable basis for exemption is presented and/or snubber life destructive test-ing has been performed to qualify snubber operability for all design conditions.

PSE&G therefore requests that the steam generator hydraulic snubbers identified in Table 3.7-4a of the proposed techni-cal specifications be exempted from such functional testing on the basis of extensive qualification testing performed during snubber fabrication.

The qualification testing docu-mentation for each snubber is available for review in sup-port of this request.

Should you have any questions in this regard, do not hesi-tate to contact us.

CC:

Mr. Leif Norrholm Senior Resident Inspector The Energy People 8102120/05 A

very tru1; -y~,

Rf ¥(4 R. L. Mittl General Manager -

Licensing and Environment

[!;olJ I/.

~'to 95*0942