ML18085A804

From kanterella
Jump to navigation Jump to search
Requests That Steam Generator Hydraulic Snubbers Identified in Proposed Tech Specs Be Exempted from Functional Testing on Basis of Extensive Qualification Testing Performed During Fabrication
ML18085A804
Person / Time
Site: Salem PSEG icon.png
Issue date: 02/04/1981
From: Mittl R
Public Service Enterprise Group
To: Miraglia F
Office of Nuclear Reactor Regulation
References
NUDOCS 8102120105
Download: ML18085A804 (1)


Text

Public Service Electric and Gas Company 80 Park Plaza Newark, N.J. 07101 Phone 201/430-7000 February 4; 1981 Director of Nuclear Reactor Regulation U.S. Nuclear Regulatory Com.mission Washington~ D.C.

20555 Attention~

Mr. Frank J. Miraglia, Chief Licensing Branch 3 Division of Licensing Gentlemen:

PROPOSED TECHNICAL SPECIFICATIONS HYDRAULIC SNUBBERS NO. 2 UNIT SALEM NUCLEAR GENERATING STATION DOCKET NO. 50-311 The NRC's proposed full power technical specifications for Salem 2 concerning hydraulic snubbers allows for exemptions from functional testing for individual hydraulic snubbers that are "especially difficult to remove" or in "high radia-tion zones during shutdown" if a justifiable basis for exemption is presented and/or snubber life destructive test-ing has been performed to qualify snubber operability for all design conditions.

PSE&G therefore requests that the steam generator hydraulic snubbers identified in Table 3.7-4a of the proposed techni-cal specifications be exempted from such functional testing on the basis of extensive qualification testing performed during snubber fabrication.

The qualification testing docu-mentation for each snubber is available for review in sup-port of this request.

Should you have any questions in this regard, do not hesi-tate to contact us.

CC:

Mr. Leif Norrholm Senior Resident Inspector The Energy People 8102120/05 A

very tru1; -y~,

Rf ¥(4 R. L. Mittl General Manager -

Licensing and Environment

[!;olJ I/.