Text
- '
_J.
e PS~G CF.'
c.,g, 1..J Public Service e:!ctric and Gas Company
--~.
Cc LW~*
t~~~
.. ~C***:(-
~t~;~~
1--**
i;.;.)
80 Park Plaza Newark, N.J. 07101 Phone 201/430-7000 January 23~ 1981 Director of Nuclear Reactor Regulation U.S. Nuclear Regulatory Commission Washington~ D.C.
20555 Attention:
Mr. Frank J. Miraglia, Chief Licensing Branch 3 Division of Licensing Gentlemen:
TEST AND SCHEDULE INFORMATION ENVIRONMENTAL QUALIFICATION OF SAFETY RELATED EQUIPMENT NO. 1 AND 2 UNITS SALEM NUCLEAR GENERATING STATION DOCKET NOS. 50-272 AND 50-311 Your letter dated October 1, 1980 requested information re-lated to environmental qualification testing to be conducted within the next two years on equipmen~ used, or to be used, at Salem.
The following information is provided in response to that request.
Wyle Laboratories is presently conducting an extensive environmental qualification test program in Huntsville, Alabama on two types of pressure transmitters.
One is a Rosemount Model 1153, Series "D" and the other is a Foxboro Model N/ElO.
PSE&G is a member of the Owner's Group sponsoring this pro-gram.
The program itself is being directed by the Wisconsin Electric Power Company.
PSE&G is planning to use the Rose-mount transmitter in safety systems at Salem.
Attached is a copy of the current Phase I test schedule, which is related to IEEE Specification 323-1971.
Phase II, which is related to IEEE Specification 323-1974 (including aging) will commence upon completion of Phase I.
It is ex-pected that the testing will take approximately 18 months to complete.
The Energy People 81 G.":~ \\D 3 :G 'Ir'/
95-0942
Director of Nuclear Reactor Regulation 1/23/81 Should you have any questions in this regard~ do not hesi-tate to contact Mr. J. J. Schubel at 201/430-8192.
CC:
Mr. Leif Norrholm Senior Resident Inspector BM03 1/2 R. L. Mittl General Manager -
Licensing and Environment
---~
. \\IEPCO H.ST StltEOULE PHASE TESTING -
ROSEMOUNT AND,FOXBORO.TRANSH'1TER.
Test Setup MFG Ca 11brat1 on Baseline Functional Rad1atton (Inc. Pre.t durtr.g,
. an~ Post-FuncttonalsJ Pre-Seismic Functional Se1smtc Post-Se tsmic Fune t ton a 1
- Pre-LOCA Functional LOCA Post-LOCA Functional Post-Test Inspection Report I)
Receipt of durrrny specimen I 2)
Receipt of ~ctual spr.clmcn WYLE J /N 115:7. !;11.
Weeks Beginning
~""'
- n Ll ::-iRn.
Nw 1Q8f OP~-
1080 Jan.. 1-;i8l
~eb.1981 29 6
13 20 21 j
1 o 11 2,,
1 I a I 1 s I 22 I 29 s I 12 I 19 26 2 *I 9 I
2.....
I t
1 T
1 PAY11ENT SCHEDULE
~1~6K TSU co~rletion (10/15/00)
..
- a§BSK Test completion (1/11/80).
- .~2SK Test report submission* (2/10/:JW)
Ill
. '\\.
Cl e