ML18085A309

From kanterella
Jump to navigation Jump to search
Forwards LER 79-056/01X-2
Date released: 11/29/2018 Download: ML18085A309


LER 79-056/01X-2:on 790831,tests Performed on Facility Indicated That RHR Pump Flow Would Exceed Design Runout Flow.Caused by Sys Resistance Being Lower than Desired.Flow Instruments Recalibr to Meet Functional Requirements
ML18085A310
Person / Time
Site: Salem PSEG icon.png
Issue date: 11/28/1980
From: Randolph J
Public Service Enterprise Group
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
References
Download: ML18085A310 (1)
Forwards LER 79-056/01X-2
ML18085A308
Person / Time
Site: Salem PSEG icon.png
Issue date: 11/28/1980
From: Librizzi F
Public Service Enterprise Group
To: GRIER B H
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
References
Download: ML18085A308 (4)