ML18085A297

From kanterella
Jump to navigation Jump to search
RO 80-55/01P: on 801029 During Radiographic Testing of Steam Generator 11,12,13, & 14 Feedwater Nozzle to Pipe Welds, Indications Found in Weld Areas of Steam Generator 13. Cause Unknown.Welds Are Undergoing Exam
ML18085A297
Person / Time
Site: Salem 
Issue date: 10/29/1980
From: Midura H
Public Service Enterprise Group
To: Grier B
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
References
RO-80-55-01P, RO-80-55-1P, NUDOCS 8012010398
Download: ML18085A297 (1)


Text

PS~G Public Service Electric and Gas Company P. 0 Box # 168 Hancocks Bridge New Jersey 08038 Mr. Boyce H. Grier Director of USNRC October 29, 1980 Office of Inspection and Enforcement

--:Region 1

,- 631 Park Avenue King of Prussia, Pennsylvania 19406

Dear Sir:

REPORTABLE OCCURRENCE 80-55/0lP SALEM NO. 1 UNIT LER

~

b This letter will serve to conf irrn our verbal report to the NRC Resident Inspector on Wednesday, October 29, 1980, advising of a potential reportable occurrence in accordance with Technical Specification 6.9.1.8.

During radiographic testing of Nos. 11, 12, 13 and 14 Steam Gen-erator feedwater nozzle to pipe welds, several indications were found in the weld areas of the No. 13 Stearn Generator.

The cause and nature of the indications are not yet known and the welds are presently undergoing further examination.

A detailed report will be submitted in the time period specified by the Technical Specifications.

Very truly yours, H. J. Midura Manager -

Salem Generating Station JR: lds CC:

General Manager - Electric Production Manager - Quality Assurance so 12 rn ~ o _3'!~ -

  • r-. :_ = ;. ~,. *~ - :