ML18082B272
| ML18082B272 | |
| Person / Time | |
|---|---|
| Site: | Salem |
| Issue date: | 09/02/1980 |
| From: | Midura H Public Service Enterprise Group |
| To: | Grier B NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I) |
| References | |
| IEB-79-01B, IEB-79-1B, NUDOCS 8010060130 | |
| Download: ML18082B272 (3) | |
Text
~":--*:--. -.-.:---
5r) ~z.. 72-Public Service Electric and Gas Company P. 0. Box #168 Hancocks Bridge, New Jersey 08038 Mr. Boyce H. Grier Director of USNRC September 2, 1980 Off ice of Inspection and Enforcement Region 1 631 Park Avenue King of Prussia, Pennsylvania 19406
Dear Mr. Grier:
ENVIRONMENTAL QUALIFICATION OF CLASS IE INSTRUMENTATION AND ELECTRICAL EQUIPMENT NO. 1 UNIT SALEM GENERATING STATION An environmental qualification review report was submitted to the Director of Nuclear Reactor Regulation, attention Mr. A. Schwencer, Acting Chief, on August 25, 1980.
This review was undertaken in accordance with the requirements of NRC IE Bulletin 79-0lB, "Environmental Qualification of Class lE Equipment" and NUREG 0588, "Interim Staff Position on Environmental Qualification of Safety-Related Electrical Equipment".
During the course of this review, problem areas were identified with respect to certain pieces of equipment where no documentation was available, documentation was insufficient based on new requirements imposed or the review process was not completed but the data indicates acceptable operation.
In accordance with the requirements of NRC IE Bulletin 79-0lB, the attached Table B from the report identifies potential deficiencies regarding equipment environmental qualification for Salem Unit 1.
Preparations are being made to identify changes to operating pro-cedures and/or notification to the operators with respect to the items listed in Table B.
In addition, a tabulation of required design changes is also being prepared.
Supplemental information with respect to this reportable item will be contained in a follow-up licensee event report.
JMZ:lds Attachment
- ~*
The ~nergy People S 0lOORn t')O H. J. Midura Manager -
Salem Generating Station 95-2189 (5M) 10*79
TABLE B Reportable Potential Deficiencies Regarding Equipment Environmental Qualification I.
No Documentation to Support Proper Operability A.
Steam Generator Wide Range Level Transmitters LA0009 (LT-501)
LA0015 (LT-502)
- LA0021 (LT-503)
LA0027 (LT-504)
B.
E/P Operator for Main Steam Atmospheric Power Operated Relief Valves (11, 12, 13, 14 MSlO's)
C.
Limit Switches for Main Steam Drain Valves (11, 12, 13,.
14 MS7) and Main Steam Bypass Valves (11, 12, 13, 14 MS18)
D.
CMC and Enclosure for Local Ope.ration of the Main Steam Stop Valves (11, 12, 13, 14 MS167)
E.
Steam Generator Auxiliary Feedwater Flow Indication -
Square Root Extractor Instrument and Power Switch FA3969 FA3970 FA3971 FA3972 F.
E/P Operator for Residual Heat Removal Flow Control Valve (11, 12, RH18)
G.
Flow Instruments for RHR Pump Recirc Valve (11, 12 RH29)
Control FA2569 (FIC-641A)
FA2481 (FIC-641B)
H.
Limit Switches for Containment Isolation Valves Located Outside the Containment 1CC215 1CC113 1CV7 11GB4 12GB4 13GB4 14GB4 1WL16 1VC8 lVClO 1VC12 1VC14 1SJ53 1SJ60 1NI32 11SS94 12SS94 13SS94 14SS94 1WL17 1WL108 1WL97 1WL99 1WL13
TABLE B 2 -
I.
Solenoid Valves for Fan Cooler Service Water Valves (ll-15SW65, ll-15SW57, ll-15SW223)
J.
Instruments Associated with Fan Cooler Unit Service Water Valve (11-15 SW223) Flow Control FA3160Z-l, Z-2, C-1, C-2, C-3, E/P FA3165Z-l, Z-2, C-1, C-2, C-3, E/P FA3169Z-l, Z-2, C-1, C-2, C-3, E/P FA3172Z-l, Z-2, C-1, C-2, C-2, E/P FA3176Z-l, Z-2, C-1, C-2, C-3, E/P K.
Limit Switches for Boron Injection Tank Recirc Valves (1SJ78, 1SJ79, 1SJ108)
L.
Hydrogen Analyzers II. Unqualified Devices A.
Steam Generator Wide Range Level Instrument Panels 448A, B, C, D B.
Limit Switches (Submerged) for Containment Isolation Valves 1CV3 1CV4 lCVS 1SJ123