ML18082B204
| ML18082B204 | |
| Person / Time | |
|---|---|
| Site: | Salem |
| Issue date: | 09/05/1980 |
| From: | Mittl R Public Service Enterprise Group |
| To: | Miraglia F Office of Nuclear Reactor Regulation |
| References | |
| NUDOCS 8009190515 | |
| Download: ML18082B204 (1) | |
Text
0 PS~CJ9 Public Service Electric and Gas Company 80 Park Place Newark, N.J. 07101 Phone 201/430-7000 September 5; 1980 Director of Nuclear Reactor Regulation U.S. Nuclear Regulatory Commission Washington, D.C.
20555 Attention: Mr. Frank J. Miraglia, Chief Licensing Branch 3 Division of Licensing Gentlemen:
I.C.7 NSSS VENDOR REVIEW OF PROCEDURES NO. 2 UNIT SALEM NUCLEAR GENERATING STATION In response to your verbal request; PSE&G submits the following with regard to the subject procedure review:
I.C.7 NSSS Vendor Review of Procedures Westinghouse has reviewed the Salem Emergency Operating Procedures and Power Ascension Test Procedures.
PSE&G reviewed the results with Westinghouse and incorporated the appropriate comments in the Procedures.
Should you have any questions, do not hesitate to contact us.
CC:
Mr. Leif Norrholm Salem Resident Inspector C03 The Energy People 8009190~5 f
yours; R. L. Mittl General Manager -
Licensing and Environment Engineering and Construction s*o-3 11 95-0942