ML18082A831

From kanterella
Jump to navigation Jump to search
Responds to IE Bulletin 79-03A Re Longitudinal Weld Defects in 300 Series Fusion Welded Pipe in safety-related Sys.No Matl Used Where Code Requirements for Pressure Design Exceed 85% of Max Allowable Stress at Design Temp
ML18082A831
Person / Time
Site: Salem  
Issue date: 07/14/1980
From: Schneider F
Public Service Enterprise Group
To: Grier B
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
References
IEB-79-03A, IEB-79-3A, NUDOCS 8008070174
Download: ML18082A831 (1)


Text

. /

Frederick W. Schneider Vice President Public Service Electric and Gas Company 80 Park Place Newark, N.J. 07101 201 /430-7373 Production July 14, 1980 Mr. Boyce H. Grier, Director U.S. Nuclear Regulatory Commission Office of Inspection and Enforcement Region 1 631.Park Avenue King of Prussia, Pennsylvania 19406

Dear Mr. Grier:

NRC IE BULLETIN 79-03A LONGITUDINAL WELD DEFECTS

- ASME SA-312, 300 SERIES SS WELDED PIPE NOS. 1 AND 2 UNITS SALEM GENERATING STATION In response to NRC Bulletin No.79-03A, Items 1 and 2, we submit the following:

In accordance with the requirements of Enclosure 1, Items 1 and 2 of Bulletin 79-03A, a survey was conducted of ASTM A-312, 300 series fusion welded pipe in safety-related systems.

The results of the survey indicate that no material of this type is in use where code requirements for pressure design exceed 85% of the maximum allowable stress at the design temperature.

If you require additional information, we will be pleased to discuss it with you.

cc Sincerely,

~

/

I NRC Office of Inspection & Enforcement

  • l /

Division of Reactor Construction Inspection /

Washington, DC 20555 8 u 0 8 0 7*0 17$'