! ; 1. *~ *.. _.
Thomas J. Martin Public Service Electric and Gas Company 80 Park Place Newark, N.J. 07101 201/430-8316 Vice President Engineering and Construction Mr. Boyce H. Grier, Director U. S. Nuclear Regulatory Commission Office of Inspection and Enforcement Region 1
- 631 Park Avenue King of Prussia, Pennsylvania 19406
Dear Mr. Grier:
UNDETECTABLE FAILURE IN ENGINEERED SAFETY FEATURES ACTUATION SYSTEM 10CFRSO. 55 (e). "SIGNIFICANT DEFICIENCY" NO. 2 UNIT SALEM GENERATING STATION December 21, 1979 On November 14, 1979, a report was made to your office relative to the potential loss of the protective function in the subject system, which was initially identified by our NSSS Supplier (Westinghouse) on November 8, 1979 pursuant to the provisions of 10CFR50.55(e).
PSE&G Engineering has reviewed the information supplied by our NSSS Supplier and attached for your review are the results of our evaluation.
- If you require additional information, we will be pleased to discuss it with you.
Attachment cc:.Mr. L. J. Norrholm NRC, Hancocks Bridge Very truly yours, g-002150