ML18081B037

From kanterella
Jump to navigation Jump to search
Forwards LER 80-002/03L-0
Date released: 10/01/2019 Download: ML18081B037


LER 80-002/03L-0:on 800104,discovered That Functional Tests of Power Range Neutron Flux Low Trip Setpoint When Greater than 25% Power Had Not Been Performed Since 1976.Caused by Lack of Procedures for Tests
ML19260D978
Person / Time
Site: Salem 
Issue date: 02/05/1980
From: Murphy M
Public Service Enterprise Group
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
References
Download: ML19260D978 (1)
Forwards LER 80-002/03L-0
ML18081B036
Person / Time
Site: Salem 
Issue date: 02/05/1980
From: Librizzi F
Public Service Enterprise Group
To: GRIER B H
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
References
Download: ML18081B036 (3)