ML18081A940
| ML18081A940 | |
| Person / Time | |
|---|---|
| Site: | Salem |
| Issue date: | 12/18/1979 |
| From: | Schneider F Public Service Enterprise Group |
| To: | Grier B NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I) |
| References | |
| IEB-79-28, NUDOCS 8001240348 | |
| Download: ML18081A940 (1) | |
Text
Frederick W. Schneider Vice President Public Service Electric and Gas Company 80 Park Place Newark, N.J. 07101 201 /430-7373 Production December 18, 1979 Mr. Boyce H. Grier, Director u.s. Nuclear Regulatory Conunission Off ice of Inspection and Enforcement Region 1 631 Park Avenue King of Prussia, PA 19406
Dear Mr. Grier:
POSSIBLE FAILURE OF NAMCO MODEL EA180 LIMIT SWITCHES AT ELEVATED TEMPERATURES NRC IE BULLETIN 79-28 SALEM GENERATING STATION UNIT NOS. 1 AND 2 An investigation into. the application of the *subject limit switches has shown that, although NAMCO EA 180 switches have been installed, none fall in the identified group with faulty upper gaske~s. This response applies.to both units of our Salem Gen-erating station.
If you* have any further questions on this matter, we will be pleased to discuss them with you.
Sincereiy, CC* Director, Office of Inspection & Enforcement USNRC Division of Reactor Operations Inspection Washington, DC 20555 I