Forwards LER 79-055/01X-1
Date released: 11/29/2018 Download: ML18081A664


LER 79-055/01X-1:on 790830,in Response to NRC Query Re Torque Valves Required for Closing Containment Ventilation Isolation Valves Under Incident Conditions,Actuator Torque Valves Determined Insufficient.Caused by Calculation Error
ML18081A665
Person / Time
Site: Salem PSEG icon.png
Issue date: 11/10/1979
From: Kapple A
Public Service Enterprise Group
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
References
Download: ML18081A665 (1)
Forwards LER 79-055/01X-1
ML18081A663
Person / Time
Site: Salem PSEG icon.png
Issue date: 11/10/1979
From: Librizzi F
Public Service Enterprise Group
To: GRIER B H
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
References
Download: ML18081A663 (3)