,z COUNTY OF *ESSEX
)
)
SS.
)
AFnDAVI'l' OF ROBERT P. DOU~..S ROBEJa' P. OOUGLAS, beinq first duly sworn acec:d-inq to law, c1epc~.s and states:
l..
I. am. employed by Public service Elecuic &. Gas Ccmpany as Licensin9 Manager and ~ng Znviiomnent Manager.
My p_"'"Of cssional quali!i.cations which I incarpcratc by reference heJ:e.in a~c ccntained in the t.rl'lUSc%ipt cf this prcceedin~
!o1lowinq T:r..
4~2...
- 2.
I have su-pervised t.~e calc:tllation of the es-timated dose associated with movinq and storinq spent fuel from the unenlaJ::9ed (264.spaces)" Salem Un.it.. l: to the elllarr;cd (1l.7tl. spaces}
s~"lt. fuel pool of Salem Unit 2.
As shown in Attachment l,. hereto which is also in~~at~ he:rci.n, t.11e cose resulting !.rem*m.ovinq o~i! cask containing two fuc.l a.sscmb1ies is approxi.ma~ely 0.4 man rem.
This dose docs r.ot i.ncJ.uce the additional.dose associated wit.~ the tiansf cr oz fuel £~cm Unit 2 to Unit.l if disp¢sal is not availab1e offsite and the Unit l pool must then be enlarged.
- 3.
I have also* est'2blis.hed t..Jie number of spent.
fuel clements which will have to be transferred from Unit l to Unit 2 i1 the above desC%i.bed scheme is to be carried out in accordance with t.~e latest infer.nation ~ncerninq sc.~edule and nllmber of spent fuel elements to be discharged a:f ter
- .i.--~*.*
e e
each cycle.
As shewn in At:tachmerit 2r which is inc:crpo:rated by* refSJ:ence hercj.n, *the number of spent fuel elements to be trans:ferJ:ed is 500...
~*hus the total man rem ~posu.re as-sociated wit.~ such a tr:msier is 0.4 ~ 250 = 100, considerably qreater than the 2-5 man rem. asacciatad wit.~ chan9inq tbe
- racka in unit l with spent fue.l elements in t.lle poo.l.
4 *.
I thuS conclude.that, ~9 o-;hcr reasons, it is pref e.rable to expand the tinit l sp.ent fuel. pool rather than shipping.the spent fuel to an cnl.ar9e1:1 Onit 2' spent f1.lel pool..
SWO%l1 and subscribed to
)
before me this ~day
}
of~, 1979
)
I '
OL~<~~~l NOl'~R~ PUBLIC J
Esti:natca acse from moving and storiilf3 spent fuel
£retll unit ND. l in the Ynit No. 2 spent.!uel pool.
11 i* openttcrs tc ua*lcad spen~ !ue.l cask.
place irt <!ecoo pit. and wash down, place i11 transfer pool and remove head*.
i ~c:
3 brs~ ~ 3.S._mr/~. *.
- 2)
' cperatcrs to load 2 fuel asae!liblies in-a uack (one-persca. ta operate brid.ge, one to operate crane, oae to operate fuel handlitl9 tools. l hea1th physics and 2 to record assemblies m.oved.
6-people :c 10 minutes/as~ly. x 2 a~lies x 3.5 mr,lbr.
3 l 6 peopl~ for 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> t.o set cm;k head.
S. people :r 1 hr. x 3.5 mr/br.
- 4) 6 operatm:~ for 2 hour2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br />s: (1 hcur to decon casl:,. l hc:il-r to load cask Ott truck) en*
&llft'aqe 10. mr/hr field.
7.0.,.
21 6 people x l hrs. :c lG mr/hr.
l-20.
5}
Truck driver mld assistant appcoximatel~
15: minutes t-o* dri"Ve frcm Unit l to Onit.. 2
!uel bandl.ing baildimJ (approx. 5 mr./hr.
in eab.;..
2 pecple x 15 hrs. : 5.0 mr/hr.
bO
%.S
- 5) 6 operators to unload, rina<t dcwn, and place cask in !ne.l transfer poo.l
(
2 hrs}o
- s. people x :z hrs. x 10 mr/hr.
7}
' people to remove cask head at transfer pool (approx. l hr.).
6 pegple :c l hr. x 3.5 mr/br *.
- 8) i
~ operators to move 2 fuel assemblies frcm cask to racks (approx. 10 minutes/
asse!llbly)
- a
.121}
21 6-people.:: 20. hrs..
~ 3 *. s mr/hr.
7.0
. -;n
-2'-
- 9) 6 opera.tors for l bcur to set. cask head.
.oosz Cman-mrem/hrl 6 pecple x 3.5 mr/br. ~ l hr.
21 l C)
- 6 operators fer 2 hoers to deccn cask and* load Oft trucJt to return to Unit lie-. l
{ catlJt empty~ approx. l lB' /hr.}.
6 pecple x % hrs. x* 1 *.(hr.
- ll.*
ll) T.ruek dri11er. and a.asist.ant for approxi-JUtely 15 ainotes to retu-rn to tJnit NO. l at.s mrjhr.
l people ::c* 15 hrs. :c.5 mr/br.
- l 5 n
':Otal man~rem. !or nsonng cne cask (2 !uel assemblies} from UJ:tit tltl.. l spent fael t.eol to Unit Ne. 2 spent
!ael peel.
. 3:95 raan-mzaa.
or a~*
o.~ man-rem.
l>
'l'hc 3.~ mrml/br dose rat.a-used in several 81.epa <'1£ the estimate is based on the dose rate at the fuo.l pool. and trana-fcr pool wa.ter ~r!ae=e due to om:-
spent fnol *ssesblr being SICTed
- and the-* dose rat.e ccnuiwtioa. frca *raaiocacli4es expected to be i12 tbe vatcw-.
2} *
~fuel shippiftlJ' cask dose rat.es are based en 49
- alt 173 limits oL l.O iaresalbr at six feet troa
- abippinq* cask. It. i& feet that tnia is. represe=:ta-tive of aven-gc radiat.ion !ie18 operat~ will be.
c:rposed to.
Ye~r.
1979 l9SO 1961 e 1982 19SJ 19tM 1983 1986 1987 UHJO 1999 1990
- - 1991 1992
_y FUEL ELEMENTS SHIPJ?F.O FROM SJ\\LEM UNIT 1 TO $1\\.U:;M UNIT 2 IF ONLY TUE UNIT _2 SPJ}N'f. FUEJ. P.OOl. IS EXPl\\N.DEO Ol!!ohnr9~d Ftom Stoxed tn Unit 1 Shlpp~d to Unlt 2 Di ~cluuged tram Unit 1
~~nt 1:uel Pool
_ID;>~nt r:uel Pool Unit l 40 40 52 52 SG SG S?.
.56 5G 5(;
56
~G 3G 4
52 56 36 -
S6 56 36 56 St; gs 56 56 56 56 36 56 5G 56 56 S(;
56 S6
. 56 St';
'.3G 264 500
+
6G9 1168 in Unlt a spent f u~l pool
- rh'=' pu.t:p"Jse of thitJ ttlble is.only to calcul11te! th~ t;otal nutnb~r. of sp~n1: fuel D.S""
s~m.blies to be t.:rnnsf(!r..t:l'Jd and do~~
- i1ot ~~pr~~t:!ni:. 11h.y
_F. i ~n.l mp~cifla sch~~~ fQr f u~l t:_r:.n~f'or.