{{#Wiki_filter:1 e Public Service Electric and Gas Company P.O. Box 66 Hancocks Bridge, New Jersey 08038 Salem Nuclear Generating Station July 24, 1979 Dr. Richard A. Baker, Chief Permits Administration Branch Planning & Management Division U.S. Environmental Protection Agency 26 Federal Plaza New York, New. York 10007 Attention: Mr. Clifford Lundin

Dear*Sir:

NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM DISCHARGE MONITORING REPORTS SALEM NUCLEAR GENERATING STATION PERMIT NO. NJ 0005622 . REGULATORY DOCKET fllE COPY 9Attached are the Discharging Monitoring Reports for Salem Nuclear Generating Station containing the information, as outlined in Per~~t No. NJ 0005622 for the month of June, 1979. The material removed from the main circulating water and collected on the traveling screens was removed from the property by the O'Hara Sanitation Company, Inc., King of Prussia, Pennsylvania and-deposited at the Quinton landfill. Very truly yours, H. J. Midura Manager - Salem Generating Station LKM:pgb CC: Director, Division of Water Resources (N.J. Dept. of Env. Pro.) General Manager - Electric Production Mr. Gerald M. Hansler, Exective Director, Delaware River Basin Conunission, P.O. Box 7360, West Trenton, N. J. 08628 Director, Office of Nuclear Reactor Regulation, USNRC, Washington, D.C. 20555 A.A. BLATZ

17. 5.18. Rl.

The Energy People 95-2189 {5M) 10-78

PEllMITTEE NAME/AL>OllESB (111cl11dc NATIONAL POLLUTANT DISCHARGE ELIMHIJ<TION SYSTEM (NPDES) Furt11 Approved o.No~ 158 - noo:*1... 1 l'acl/ily Na,11e/Loc~11 I/ diOcre.11) DISCHARGE M.ITOa!NG UEPORT (DMR) fil!!il _ _!'~S ~-~--~~L~!"--~~ME_~~~_!_!I~!:i________ <2-16>_ 11-19> ~~!!'il!!L~-~w~~K. PLA~~~_Q_OM __!!~!.?__________ NJP~~~~~~~~BEa DISC~A~l!E NUMBER


u:r--01Tor-------------*** *-*-----

-==--------------. GP AT Mii 17 2 Ii I MONITORING PE~IOD DELAWARE RIVER COOLING WATER Uc;;;J!.IIY ______________________ ------ FllOM 79 06 01 79 06 30 .!:,2CATJ2.Ji.!.0W t: !!_~ll0W~VS_f~EE~----------- YEAR MO DAY (20-21) (22-2J) (24-2$) YEAR MO DAY PARAMETER (J2-J7) 00010 2 TE~PERATURE,WATER OEG.CENTIGHADF INFLUENT 00010 1 TE~PERATURE,WATER DEG.CENTIGRADE EFFLUENT GROSS 00016 4 TEMPERATURE DIFFERENCE EFFLUENT NET 00400 1 PH EFFLUENT GIWSS 00400 2 PH INFLUENT 50050 1 FLCL~ EFFLUENT GIW~S 50060 1 CHLOI~ I NE, TOT AL IH:S I DUAL F.FFLU[NT GROSS (26 -27) (28-29) (JO-JI) NOTE: Read lnslrucllons bulore compleling lhls for.n. (J Carri 011/y) QUANTITY OR LOADING (4 Ct1rd 011IJ') QUALITY OR CONCENTRATION (.Ju-H) (54-61) (JS-4$) (46-$J) (J44S/) NO. FREo;:;NcY SAMPl.£ 1---'---:--~--'----"--~-----1--~----~--'----"--~---'--'---.....-----l EX ANALYSIS TYPE AVERAGE MAXIMUM UNITS MINIMUM AVERAGE MAXIML'M UNITS 62-6J) (644S8) (69-70) OIS 481 IS Cl11'1Dtl*IStR COUL ING ~JJ\\TL:ll,.WHEN INTK PH LESS THAN 6.0,0IS PH NOT 10 BE LESS. W-IEN XNTK PH GktATE R THAN 9.0,DlS PH NOT TO EXCD INTK i-!OT MORE THAN 3 CUNOENS MAY DIS FREE CL AT ANY TJMEwOR MORE HIM' :.:OMIN I UIEPL!\\CE:~ E:PA FOllM T-40 \\'/lllC.I! t.IAY NOT BE USED.) PAGE ---i-:i-r--- I. EPA Form 3320-1 (Rev. 10-77) Pllf'.VIOIJS EDITION TO Ill! llil:"'I.} lJIJ"fll.. ~lJPP!.V l!"i ::.x11.:.u,*r,.. l.

PERMITTEE NAME/ADDRESS (lnc/1111* 1t1cllily Na111e/Lo**u1ion I/ dlDerenl) NATIONAL POLl.UTANT DISCHARGE l:l.IMlhlATION SYSTEM (N/'IJ1':S) DISCHARGE MONITOHING REPORT (IJ/UR) Form Approved OMB Nt>. 158-R0!17J I filME_J~-_§__2 __ ~~LEf1.__GENE...!!_AT !NG------- ~---~(2_-1_6_ 17-19) e I .!!!9..!!.ru_li_Q__ARK __f!-_A_fL_ROQt.!_lU.!J _____________ _ NJ00056~ I 402 GP 17 AT -Ml I NEWARK PERMIT NUMBER DISCHARGE NUMBER 2 11


... --------------~-------

___ _N.4__-97.10.L _______________________,_ MONITORING f.ACILlJY _____________________ !:Q~TJ.Q.N_!-OWEB__!LLOW,_!YS_!:l!_EEK_' _______ -'- FROM 79 06 0-1 YEAR MO llAY PERIOD 7-9 06 YEAR MO 30 DAY DELAWARE IU VER COOL I NG ~UTER (20-2/) (22-2.J) (24-25) (2(>-27) (28-29) (JO-JI) NOTE: Read IRslruclloRs before com11leling this form. (J Card Only) QUANTITY OR LOADING (-I Card Only) QUALITY OR CONCENTRATION PARAMETER (J2-J7) (46-5.J) (5-1-61) (JB--15) (46-53) (J4-61) NO. FRE~:NCY 1----"---..:.--~--'--__;;~--..~---J--~-----~--'----~~~---='--_;.--.....-------1 EX ANALYSIS 00010 2 TEMPERATURE 1 WATER DEG.CENTIGRADE INFLUENT 00010 l TEMPERATURE 1 WATER DEG.CENTIGRADE EFFLUENT GIWSS 00016 4 TtMPEllATURC: DIFFL:RENCE EFFLUENT NET 00400 l PH EFFLUENT GROSS 004 00 2 PH INFLUENT sooso~~-1~~~~~-t"-'-~~~......... FLOW EFFLUENT GROSS 5C06C l Ct-ILORINE, TOTAL HES I DUAL EFFLUENT GROSS AVERAGE MAXIMUM UNIT& MINIMUM AVERAGE MAXIMUM UNITS 62-61) (64-68) SAMPLE TYPE (69-70) DISC 1102 IS CL1l\\IJ CUOLING WAftl~.ll'llK Ptl LESS 6.0 DIS Pll NLH u:sS.INTK PH GRTR 9.0,DIS PM NOT GRTR.NOT MORE THAN 3 CCND MAY DIS TOIAL UR Flff[ CL AT ANY TIMF.,ANO NOT MIJIU: THAN 30 MINUTES EACH TIME '=PA Form 3320-1 (Rev. 10-77) P11,;v1ous 1:01T10N To oi,:: 11r.i,1, IJ1Jl"ll flllPPl.Y I~:' i. 1'1J.t. 11*.:n*Li (l!EPLACES EPA FOHM T-40 WlllCll l~AY NOT BE USED.) PAGE OF I I I

PERMITTEE NAME/AODRESS (lllc/!lde NATIONAL POLLUTANT DISCHARGE El.IMINATION SYSTEM (NPDES) Facility Name/Loe. I/ dlOere111) DISCHARGE.ITORING REPORT (DMR) Form.Approved I 01N@.158-R0~7! i m~-_J>~-~ ~~ G __ ~_ALEM_Gt:~_E_!~~.!.!_~!'~------ <2-161 11-19> .!2!2!!.lil!.!L~..2__ Ar~__fLA_f_~-_!l00M_JJ2_!_?_________ NJ000562L I 483 NEWAHK PERMIT NU~tBER DISCHARGE NUMBER GP AT Mii 17 2 I! ---r.:J-o7ior------------*--*----- Uca!!-IIY _____________________________ _ .!:Q~TJ2.li.!-OWE~~LLQ_~~VS_f_!!EE~---------- MONJTQRING PERIOD FROM~7~9_.~0~6~-o---=0~1'-I TO,_7~9~,_0~6~_..-~3~0.___, YEAR MO DAY (20-21) (22-2J) (24-2j) YEAR MO DAY (26 27) (28-29) (JO-JI) DELAWARE IHVER COOLING WATER NOTE: Read lnatrucllon11 before complellng Ihle form. (J Carel 011/y) QUANTITY OR LOADING (4 Cur1l 011/i*) QUALITY OR CONCENTRATION (4.l-51) (j4-61) (J8-4j) (46-jJ) (jfiSI) NO. FRE~:NCY &AMPLE PARAMETER (J2-J7) ~----'--'-----.--'----'----...----+--.;.._--'---~--'---'----.----'---'----..-----I EX ANALYSIS TYPE AVERAGE MAXIMUM UNITS MINIMUM AVERAGE MAXIMUM 00010 2 TEMPERATURE,WATER DEG.CENTIGRADE INFLUENT 00010 1 TEMPERATURE,WATER OEG.CENTlGHADE EFFLUENT GROSS 00016 4 TEMPERATURE D I FF EI{ ENC E EFFLUENT Nf:T 00400 l .Pl-I EFFLUENT GROSS 00400 2 PH ll'JFLUt.Nr 50050 1 FLOW EFFLUENT GROSS 50060 1 CllLOR IN[, TOT Al l~ES llJUAL E FF LlH.:NT G110SS THIS DOCUMENT IS SIGNED WITH RECOGNITION THAT KNOW-INGL'! MAKING A FALlil! CEHTIFICATION ON THIU REPORT OR Schneider, F. W. ~~~ft 0 ~*~ 1~~~o~i~~ci~~~~l'tE~~E 1 ~~E~1i.fHNt~LrRETAci~~~~~~~ v p p ii t. Ot'"FO::NSE~. sr::i;: 10 u_s.c. § 1001 AND 33 u.s.c. §1310. (l'c11a/-

  • --*-'-*----"_r._.....o......._J.,,.J..,C....,.... 1....... o... n..__ _____,,.,,. 11111lrr ""' **1111ui..< may be firres up to $/0,000 arrd/or 111uxl11111111 TYPED OR PRINTED l1111*rilu11111e11I u/ l*clH*ee11 6 mu11tlrs urrd j )'eurs.)

COMMENT AND EXPLANATION o~- ANY VIOLATIONS (R*;.,,.n*11;:;;-;,u-;;;;.,,.,.,,...,,,. lrere) OFFICER OR AUTHORIZED AGENT UNITS 62~J) (64~8) (69-70) 79 07 24 NUMBER YEAR MO DAY OISCh 403 IS COND COOLING WATER.INTAKE Plf LESS 6.0 DIS PH NOT LESS.JNTPH 6RTR 9.0 DIS PH NOT 6RTR.NOT MOR E T~IAN 3 COMO MAY DIS TOTAL OR FREECL AT ANY TIME & NOT HORE THAN 30 MIN EACH TIME EPA Form 3320-1 (Rov. 10-77) PHEVIOIJS: EDITION TO BR uar::r. lllll"ll. !JUf'l'I.\\' l'i f,J(tf.,11*.';fl';, (REPLACES EP.t,, FORM T*40 lliHICll l.IAY NOT BE lJSED.) PAGE OF "..,

  • c:

, o T.>1 _en I I

Forni Approved PERMITTEE NAME/ADDIH::ss (ltic/uJ* NATIOHAL POLLUTANT DISCHAl~GE.,l.IMIMATION SYSTEM (NJ'DES) l'udllly Nume/Lu:*I/ diO~re111) DISCHARGE ia'ITOl11NG Hl::PORT (DAIR) NAME P. ** & G SALEM GENl:RAT ING .(1-16i-11-19) ADDRESS rio _fA-nK PLAIE RUGM-83-!]=-~-~-===== NJ0005622 a l 4B't N.~. 158-ROi:l~ Gr Af MI. NEWAr~K PERMIT NUMBi::R DISCHARGE NUMBER ___ _J~ _ _!l7 l O_L ______________________ _ MONITORING PERIOD .EAtll-lll'---------------------**---- bQ~TlQ.li.!- O\\J~~_! L l OW_! Y S.SJ!{~~--*-____ ---; .----~~~-~~----..::-------~------~- DELAWARE RIVER COOLING WATER NOTE: Reacil Instructions before complulina Chl. 2 ~---~ PARAMETER (JZ-11) Ci Car.I 011ly) QUANTITY OR LOADING (4 Caril 011/y) QUALITY OR CONCENTRATION NO. FHEOoUr-"Nr.~' -~ ** MPLE (46-51) (54-61) (38-45) (46-51) (J./4.il) l----'--~---.-------....-----t--~-----r-------.--------r-----1 EX ANALYSh". TYPE AVERAGE MAXIMUM UNITS MINIMUM AVERAGE MAXIMUM 00010 2 TE~PERATURE,~ATEH DEG.CENTIGRADE INFLUENT 00010 1 TEMPfRATURE 1 WATER DEG.CENTIGRADE EFFLUENT 1;Ross OC016 TEMPERJ\\TURE DI FFEl~ENCE E FF LU ENT tH:T 00400 1 PU EFFLUENT GROSS 00400 2 PH INFLUENT 50050 1 FLOW EFFLUENT GKOSS 50060 1 CHLO~ I NE, TOT 1\\L HES I DUAL EfFLUl:NT GfWSS TlllG llOCllMENT IS SIGNED WITH RECOGNITION THAT KNOW-1-------------------1 INGLY MAIClllG A FALSE CE:HTll'ICATION ON THIS REPOHT Oil !WPPOllTING DOCUMENT~ OR INTENTIONALLY TAMPERING Schneider, F. W. wn11 ANY Mm11-ro111NG nEv1cE oR MET110D ARE cR1M1NA1. V p. - Product_i.Qn_ oFFENsl:s. sEc: 10 u.s.c. § 1001 AND 33 u.s.c. §131e. il'mul*


I tleJ* 1111rlc:r tlreJ*c 1*1111u1t*s llldV be /i11es up to $UJ,OOO u11d /or maximum OFFICER OR AUTHORIZED AGENT UNITS 62-63)

( 64-fiB) (69-70) 365-7000 79 07 24 NUMBER YEAR MO DAY TYPED OR PRINTED impri.lOlllllc:rll o/ bctwc:e11 6 111c111ll1S a1ul S years.) COMMENT AND EXPLANATION OF ANY VIOLATIONS (R~Jtre~1ll_t1_/l_uc...,.*h-m-<1-1ts-:-lic-re""')--'---'----------'------------------'-"..._...._._ ____ _._ __._ _ __._ __ _, OIS 4li't IS ClJl.IDENSER COOLING ~JAfrR.. INTK PH LESS 6.0,0IS PH NOT LESS.INTK PH GRT 9.0,0IS Ptt NOT GRT.NOT MO RE fHAN 3 CLll,lllENSCRS MllY DISCH TlH.R FllEE CtlLORINE AT ANY TIME 1 ANO NOT MORE H~AN 30 MINUTES EACH TIME EPA Form 3320-1 (Rev. -rn-77) Pl1f;VIOll!l l:DITIOtl TO l>*c llG1:n ll11*i II. !;".llPPI \\' l.i J ;:Jt,.. n *.*, 1' (ll'-'PLAc,;:s EP/I FOlll.t T-40 WlllCll MAY NOT er:: USED-) PAGE OF I I 'I

Form Approved N;:,. 158 - R0?73 I 't I GP AT Mii 17 2 I 1 M/>NITO~ING UCia!.!IY------------------------*------ Loc1.T1oN LOWER ALLOWAYS CREEK FROM 1---7-"-9-+-'0'--6'--~0-l---i YEAR MO DAY DELAWARE RIVER COOLING WATER -~--~-------~-----*--------- YEAR MO DAY (20-21) (22-2J) (24-2j) (26*27) (28-29) (30-Jl) NOTE: Read lnalrucllona before completing lhla form. PARAMETER (32-37) (J Curd 011/y) QUANTITY OR LOADING (4 Caril 011/y) QUALITY OR CONCENTRATll:>N (46-jJ) (54-61) (.18-15) (46-.SJ) (J4-61) NO. FRE~;NCY SAMPLE t--------~-------..-----1--------.---------r----*----.---~ EX ANALYSIS TYPE 00010 2 TEMPERATURE,WATER INFLUENT 00010 1 TEMPERATURE,WATER DEG.CENTIGRADE EFFLUENT CRCJSS 00016 4 T ft-'P(l~ATURE DI FFEIH:NCE EFFLUENT NET 00'400 l PH EFFLUENT GROSS 00400 2 PU INFLUENT 50050 1 FLOW EFFllJENT GROSS 50060 l CHLORINE, TOTAL RESIDUAL. EFFLUENT GiWSS AVli:RAGE MAXIMUM UNITS MINIMUM AVERAGE MAXIMUM NAME/TITLE PRINCIPAL EXECUTIVE OFFICER THIS DOCUMENT IS SIGNED WITH RECOGNITION THAT KNOW-

i.

INGLY MAKING A FAL~E CERTIFICATION ON THIS REPORT OH /l-s h 'd F w SUPPORTING DOCUMENTS OR INTENTIONALLY TAMPERING 1 c nei er I WITll ANY MONITOIHNG DEVICE OR METHOD ARE CRltAIUAL ----


=~-------!

v. p. -

Production OFFENSE!i. SEE 18 u.s.c. § 1001 AND 33 u.s.c. §1319, (l'e11t1I-SIGNATUR OF PRINCIPAL EXECUTIVI:: UNITS 62-6J) (64-68) (69-70) 365-7000 79 07 24 liCJ.' 11111lt*r tl1c1*r: J'Wlutes lllllJ' /I~ Jines 11p lo $10.000 u11d /Or maximum ~.~~-----+----t---t----t TYPED OR PRINTED lmpri*o1'm~nl uf /,.*1wee11 6 11wutlts am/ 5 i*eur..) OFFICER OR AUTHORIZED AGENT NUMBER YEAR MO DAY COMMENT AND EXPLANATION OF ANY VIOLATION& ( l<e/a1*1we 111/ 11ll11chme11ts lwre) DIS 485 IS CONDENSER COOLING WATER.INTK PH LESS 6.0,0IS PH NOT LESS.INTK PH GRT 9.0,0IS PH NOT GRT.NOT MO RE THAN 3 COriCENSORS MAY OIS TOT. OR FREE CHLORINE AT ANY TIME,ANO NOT MORE THAN 30 MINUTES EACH TIME EPA Fo111\\ 3~120-1 (Rov. 10-77) PflEVIOllS Eo1..-10N TO 1m US!iD (liEPLACEB EPA FOHM T-40 WltiCfl MAY NOT BE USED.) 111u11.. ::;11p1*L'; 1::; rx*n*.ll".T1.:11 PAGE OF i I

PERMITTEE NAME/ADDRESS (/nc/utle NAl"IOtiAL POLLUTANT Dll:lC:HAllGE ELli,llNATION SYSTEM (Nl'DES) F.irm Apprtll'ed I Facility Na111~1l.ucu-l/ tliOcre11ll DISCHARGE -ITOR1NG RL::PORT (DMR) filMS. _ _!'_~S _ _!!___!!_ SAL£!:1.._GEMf:_!!_AT.!N.Ll --*--*-*----- <1-161=* 11-19> ~!!!IB.~2!L!)_Q_ __ ~Pili__f I..i\\~~-ROQ_f1_!J_~_!_J ____________ ~J 0 0 0 5 6 2 l a I 4 06 NfWARK PERMIT NUMBER DISCHARGE NUMBER


*------------.. *----.. ------~- ---

___ J_! __ _.9_1_10!_ ___________________ _ MONJTORING PERIOD FROM,__7_-_9_,___0_6301 i T0~)~+-0_6-t-_3_0--t YEAR MO DAY Yli:AR MO DAY ,__(_20~-2~1-)~(2-2--23) (24-25) (26* 7) (28-2!1) (JO-JI) B<;l.blI.'f __________________________ _ l:Q~T.!.Q.tiJ-.Q.U E.!l__A LI..Q~!AY.~LJ:~ EEK_ ____ -* ____ _ <.Nu. 158-IW~l~ j GPATHJI 17 2 11 I DELAWARE RIVER COOLING. WATER ' NOTE: Read lnslrucllons before completing lhh1 form. PARAMETER (32-37) (J Ca1*,1 0;;/-J')--Q-U_A_N_T-IT_Y_O_R~LO-ADING (-I Ct1rd Onlt) QUALITY OR CONCENTRATION (46-5J) (5-1-61) (38--15) (-16-5J) (J4-61) NO, FRE~~";NCY SAMPLE l--~---'---~---'----'--~-----1---'-------~---'-----'---.--------'-------~ EX ANALYSIS TY~E AVERAGE MAXIMUM UNITS MINIMUM AVERAGE MAXIMUM 00010 2 TEMPERATURE,WATER DEG.CENTIGRADE INFLUENT 00010 1 TfMPERATURE,WATER OEG.CEtJTIGRADE EFFLUENT GROSS 00016 4 TEMPERATURE DIFFERENCE EFFLUENT NET 00400 1 PH EFFLUENT GROSS 00400 2 PH I NF LU ENT 50050 1 FLOW EFFLUENT GROSS 50060 1 CHLORINE, TOTAL Rl:S IOUAL EFFLUENT GROSS THIS DOCUMENT IS SIGNED WITH RECOGNITION THAT KNOW-t-----------------1 INGLY MAKrnG A FALSli'. CERTIFICATION ON THIS REPORT OH Schneider, F. W. ~~~~0~*~1~~.o~~i~H~~~T'::,E~~E i~!E~~oHNt~LXRETAc':i~~~~':!.~ *---'-'---~--='1--------1

v. p. -

Production OFFENSES. Sl::E IU u.s.c. § 1001 AND 33 u.s.c. §1319. (l'e11u/- 1-----------------111 ..

  • 1111iltr 1/1e.*e sl111utcs may be fines up tu $/0,000 und/ur mux/11111111 TYPED OR PRINTED i11111r/w11111e11I of between 6 1111mlh1 1111tl 5 }'~urs.)

OFFICER OR AUTHORIZED AGENT COMMENT AND EXPLANATION OF ANY VIOLATIONS (Ue/e1e11ce <1/1 ullud1mc11ls here) UNITS (64-68) (69-70) 365-7000 79 07 24 NUMBER YEAR MO DAY DIS 4H6 IS CONDENSER COOLING WATERoINTK PH LESS 6.0,DIS PH NOT LESS.INTK PH GRT 9.0,DIS PH NOT GRT.NOT MO RE THAN 3 CONDENSORS MAY DIS TOT. OR FREE Ct~LORINE AT ANY TIME,ANO NOT MORE THAN 30 MINUTES EACH TIME PAGE OF EPA Form 3320-1 (Rev. 10-77) PmNm11s EDITION To ac: 11s"u l _.... 1i1 l'i Ir,: 111 Pl.,. I ti I l il : 1 ! *.,-1 n ~--- ~-= -~ ~~ (lffPl.ACEB EPA FORM *T-40 WlllCll MAY NOT BE USED.)

PERl.llTTEE NAME/ADOR!;:6S (111d11du NAtiorlAL POLLUTANT DIGCHA.RGI:: ELIMINATION GY:iiTEM (N/'lJE.h l'adliti* Nm11.*/Lvcaliu11 i/ dlU<*1*c111) DISCHARGE INITORIMG REPORT (DMR) ~;::~~-{o *i~ 1 ~fA-~-~LE~o~~N~~i1~*'~--.. ------ NJOocm!L~ I f ~~19)


,;fEWARK-*---------------*-*-----

DISCHARGE NUMBER


NJ--01Tor----*-----**-*------*-'-**- -~ -- -

MONJTORING PERIOD - 7 9 *l-"'-0 6><---.....,3.,_,0"'---l .EAc;a!.lJY __________________________ _ .!:QcaTJ~fL!-OW E !!__!L l. m1 A y s _f.!!_~E~-*--- ---- ---- MO DAY Form Appro1*e1I D N.;i. 158-R007J I GP AT H 1 I 17 2 I I DELAWARE RIVER YEAR MO

  • DAY (20-2/)

(22-23) (24-25) (28-29) (30-11) NOTE: Read lnstrucllona belore compleling this lorm. PARAMETER (J2-J7) 00015 4 llEAT MILLIONS Of UTU 1 S PER HR NET EFFLUENT NET (3 Ctml Only) (46-51) AVERAGE QUANTITY OH LOADING (54-61) (-I Car1/ 011/y) (38-45) QUALITY OR CONCENTRATION ~-----~ (46-51) (J4-6f) NO. FREo;;;NCY 2AMPLE EX ANALYS: - TYPE MAXIMUM UNITS MINIMUM AVERAGE MAXIMUM UNITS 6l-6J)


+-----+-------+--------1--------+-----f'---'-l'---<;..._64-6~'.

{69-70) ,,~ ,9J . AL :r:;(-;y:ii


P""'-'-+===~\\~:::.: *.:::;:; :-.. :*.*:*::::*;*r:*..

  • f 0 T AL CF D I SCH 4 tll, 4 0 2, 4 B J, 'di 4, 4 fl 5, 4 8 6 EPA Form 3~~20-1 (flev. 10-77) r11::v1ous EDITION To BE w;u-'

l.11 ;-fi'. ~~lJPPi.\\' 1:.;; L.O::H.* 11*~. r.~~- (HEPl.ACE:S EPA FORM T*40 WHICU MA\\' MOT DE IJ6E0.) PAGE OF

PERMITTEE NAME/ADDRESS (1"clude f.IAl'IONAL POL.LUTANT DISCHARGE EL.IMINATION SYSTEM (NPDHS) f'acillty Na111*/l.oca11* . dlOemil) DISCl-IAHGE M-TOFUNG Rt::PORT (DMR) NAME P.S & G SALEM GENERATING (2-16) (11-19) ADDR!g!~ ~er P -~K_-r:rac_E"_ Roo"M a3T7=~~==== MJooos6Tc=J F a1a NEWARI< PERMIT NU~ DISCHARGE NUMBER f"orm Approved 0-No.' 158 - ROO~J + I GP AT Mii 17 2 I I I

==~ --FfJ~-trr~r== '====~---==~:==**:== ~~f'UTQRING P-E-R-10-D---~ FROM,__7 __ 9_,__ __ 0_6-+--Qlr-:17~9-~0~6~T~Q DELAWARE RIVER PARAMETER (J2-J7) 00056 l FLOW HATE (GALLONS PER DAV) EFFLUENT GROSS O!JJla l BOO,.5-DAY 1 20 DEG. C. EFFLUENT GROSS 00530 l SOLIDS, TOTAL SUSPENDED EFFLUENT GROSS 74055 1 COLIFORM-FECAL EFFLUENT GROSS YEAR MO DAY] iu [YEAR MO DAY ('ill-21) (22-2J) (24-25) Q6*27) (211-2!1) (JO-JI) NOTE: Read lnslructlona before complellng this form. (J Curt/ 011IJ*) QUANTITY OR LOADING (4 Carel 011/y) QUALITY OR CONCENTRATION (46-SJ) (54-61) (JS-45) (46-.:iJ) (54-61) NO. FRE~:NCY SAMPLE 1~~----~--,r-------.-~---t---~----..-~-----"""T"~---'---....----, EX ANALYSIS TYPE AVERAGE" MAXIMUM UtllTS MINIMUM AVERAGE MAXIMUM UNITS 62-6J) (64-68) (69-70) 1-------------------1 INGLV MAIUNG A FAL.61:: CERTIFICATION ON THIS HEPORT OH f.A NAME/TITLE PRINCIPAL EXECUTIVE OFFICER THIS DOCUMnlT IS SIGNED WITH RECOGNITION THAl" KNOW-

    • -*------M-~ ~

J Schneider, F. W. ~~~~ 0~*~*~':.1o~~~R~~~T~E~~E 1~~E~~ 1 .;>H~~LXRETAc~~~~~1~- V p Production oFFENsi::s. si:.E 1a u.s.c. § 1001 AND 33 u.s.c. §1s1s. O'eiwt-s1GNATURE PRINCIALEXEcuT1vE 365-7000 7 9 O 7 2 4 ties 1111./er tlie.<e l'l11lulc* 111.iy be /i11es 11p lo $10,000 1md/or 111axi11111111 bT~~~~~~~.,~~-t~--t---1 TYPED OR PRINTED l111t>r/w11111e111 o/ /Jetwet*n 6 mu11t/is a11d j }'ears,) OFFICER OR AUTHORIZED AGENT NUMBER YEAR MO DAY COMMENT AND EXPLANATION OF ANY VIOLATIONS (Re/.,,;;,,7ai/ ullaclmients liere) DIS 8713 IS OISCllfll~GE 40713. AVERAGE VALUE IS 30 DAY DAILY AVE, MAX VAL IS 7 DAY DAILY AVEfTSS 1 DOD5). DISCH AllGE MONITOR PHIUH Tll COMB lrllTH U[S 1t87. FLOW MEAS CONT FOR CONT DIS 1 1/30 FOR INfERMITTF.Nf DISCH. EPA Form 3320-1 (Rev. 10*77) PFlEvwus EDITION To ai:: usn, llln'll. EUPPl.Y l~i ! 1fi~Ad~."c'i'U (l"lEPl.ACl:s EPA FORM T-40 WlllCU M!\\Y NOT Bl! USED.) PAGE OF

PERMITTEE NAME/ADDRESS (ltlc/111/e l'aci/lly Name /Localio11 I/ di!]amt) NATTOF.:Al:POLLU'l'ANT DIUCHARGE C:LIMIHATION SYSTEM (NPOES) DISCHARGE MONITORl~IC; HEl-'ORT (OMR)

~=!Eaa~~o 5

~(Ii ~i~t~L~t~~~fl~~[jl!~==--=~=~~ NEWARK

~ NJ= Di!_Ql-=====-==-=====

(1-16) 9 (17-19) [ N.J000562c F 48C PERMIT NUMBER DISCHARGE NUMBER PERIOD '"-" r ; rlpprovea I OMlJ No. 158.. R0073 a . I W GP AT M~l I 11 2 rl I I ll~tr! _____________________ _:_ __ _ f.IONITOHING 7g* 0-6. 01 DELAWARE R l VE It 79 06 30 FROM TO YEAR MO DAY YEAR MO DAY !:QCAT.!.Q.tf..!-m~ E !!__ALL 0~.A_YS ___,C_B_E E.!$_ ____ -----_ (20-21) (22-2J) (U-25) (2{.:"il) (28-29) (.IO-Jl) NOTE: Read lnulrucllona before complellng this form. PARAMETER (32-17) (J C:t1rd 0111)') QUANTITY OR LOADING (*I Card 011/y) QUALITY OR CONCENTRATION (46-53) (54-61) (18-45), (46-SJ) (S4-6J) NO. FRE~:NCY SAMPLE 1-----------..-----------.-----1-----'----r---'---"'----,.----~-----.--------i EX ANALYSIS TYPE AVEHAGE MAXIMUM UNITS MINIMllM AVERAGE MAXIMUM 00530 4 SOLIDS, TOTJIL SlJSPEt.iOEO EFFLUENT NET 00550 4 OIL ANO GR[ASE EFFLUENT NET 00551 1 PETROLEUM HYOROCARCIONS EFFLUENT GROSS 01042 4 CCPPER,TOTAL (AS CU) EFFLUENT NET 01045 4 IHON,TOTAL IAS FU EFFLUENT NET 5G050 1 FLOW EFFLUENT Gl'OSS SAMPLE MEASUREMENT

~.!~\\![~~~;j*

SAMPLE MEASUREMENT iii~~~~i1~~~:~¥'" NAME/TITLE PRINCIPAL EXECUTIVE OFFICER THIS DOCUMHlT IS SIGNC:D WITH RECOGNITION THAT "KNOW-INGl.Y MAKll~G A FALS.E CERTIFICATION ON THIS REPORT 011 Schneider, F. W. ~~ft 0~~ 1~~10~ 1 1~~~~~~T~E~~E 1~~E~:A 0 HN6'~LZRET~~~~~~~'t. V.P. - Proc;l_uction oFFENsE.i. "'""' 1a u.s.c. § 1001 AND 33 u.s.c. §1310. u*m.. 1- -~~~~-----* ,,,.,,. w1,frr Ilic!.)*,~ .~tat11le~ "" be: /ines up 'o $101000 a11d /or 1111u.*;11111m TYPED OR PRINTED im11rhoum1.ml of bt'IU'een 0 111u11tlu u11d 5 J'C"rs.) OFFICER OR AUTHORIZED AGENT COMMENT AND EXPLANATIONOF. ANY VIOLATIONS (llefae11**" ;;// ulludwwlll.1' here) -------------~--------------~ EPA Form 3320*1 (Rev. 10 77) f;',i,~;~ 110,'.:Ti-~~!!:~rl,~;c:._*/;~.;::~;~'*', 1 7 c; 1 ~ Pl -~P (lll'1"LACl:OS EPA FORl\\I T-40 \\11/HICll MAY NOT BE USED.) UNITS 62-6.l) (6-1-68) (69-70) 79 07 24 NUMBER YEAR MO DAY

PERMITTEE NAME/AOORE66 (lncllule Facil/ly Name /Lucalio11 If dl!lereul) NATIONAL POLLUTANT DISCHAHGE ELIMINATION SYSTEM (Nl'DES} ~ril-_J1...!..~. & G---~~!:E~LGEN~_!.l.!!.lNli ____..:; ____ _ DISCHARGE MONITORING REPORT (!JAIR) NJ000~-~ 6 ~*_=J F 8~~ 19 Form Approved I O/llD No. 158 - Roon I e.GP AT *_MI I ADDRESS 80 .~K PLACE ROOM 8311 ---NEWARK------~-------------- ---1\\fJ-071 oT------,--------~----- PERMIT NUMP~ DISCHARGE NUMBER 1.1 2 11 --~----------~--------*--~-- MONITORING FROM,_7~9---...~0~6-+~0_1_, YEAR MO DAY (20-21) (22-23) (24-25) PERIOD 06' 30 MO DAY (28-29) (30-Jl) DELAWARE RIVER NOTE: Read lnslructlons before complellng Ihle form. (3 C11rd Oidy) QUANTITY OR LOADING (4 Card 011ly) QUALITY OR CONCENTRATION (-16-51) (54-61) (38-45) (46-53) (S4-61) NO. FRE~;NCY &AMPLE PARAMETER (32-37) 1--------.,--------.-----+--"'--'-----.---'-----..-------------r-------I EX ANALYSIS TYPE 00530 '4 SOLIDS, TOTAL SUSPENDED EFFLUENT NET 00550 4 OIL AND GREASE EFFLUENT NET 00551 1 PETROLEUM HYDROCAHBONS EFFLUENT GROSS 50050 l FLOW EFFLUENT GROSS AVERAGE MAXIMUM UNITS MINIMUM NAME/TITLE PRINCIPAL EXECUTIVE OFFICER THIS OOClJMEi'IT IB SIGNED WITH RECOGNITION THAT KNOW-


*-----1 INGLY MAKING A FALSE CERTIFICATION ON THIS REPOllT OH S h

. d F w SUPf'OHTING l)0CIJMEN16 OR IN'fENTIONALLY TAMPERING c nei er I WITH ANY MONITOIHtlG llEVICE OR ME11100 ARE CRIMINAL v !.' .. Pi:pr1uct:ton oi:rENsEs. sEc: rn u.s.c. § 1001 AND 33 u.s.c. §131e. <l'"""'- ~-=-"-""-=-------4 lies 11111/cr 1/1*.1*.: sl<1l1tl*s may be /i11cs 11p lo $/0,000 arr<l/or 111uxi11111111 AVERAGE MAXIMUM UNITS 62-()J) ( 64-68) ( 69-70) 79 07 24 NUMBER YEAR MO DAY TYPED OR PRINTED i111111*1w11111e111 11/ l*elll'ee11 (I 111<mlhs amf 5 )'eur3.) COMMENT AND EXPLANATION OF ANY VIOLATIONS (ll41*rc11~~;;-;,-/l~u-1t~11-cl-111-w-11l-s 0-/1-e~re-)~~--=~----------'---------------.,._-Wb<M.lia-1------lL----L---L--..J DIS tl7A IS 'iBlA PAGE--0-F' __ EF'A Fo(m 3320-1 (Rev. 10-77) ri'/1';~,10~~~.~~~;r:~~J.'r,~;~,.~:~~*n (lll:PLACES EPA FORM T-40 WHICH MAY NOT or:: USED.) 1 7. r:;. 1 R. 'Pl -RP I I

f'ERIAITTEE Nl\\ME/ADDRESS (foduJc NATIONAL. POLl.UTANT DISCIMRGE El.IMHIATION SYSTEM (NPl>ES) l'a.:illly Na111~/(.ornli<1* . dlOcm11) DISCHARGE MO.ORING REPORT (OMR) form Approved I OA.o..'58 - Jl007 3. ~- I NAME P.S. G SALEM GENEl~AT ING (2-/6) 11-19)

~E£S-ff(fp~ (iCPDict
*n.ooM-tf317____________

NJ0005622 r 'tBH


~.fn*~ARK--------.--------*------


~JJ ___ offtH------------------. *-*-----

PERMIT NUMBER ---------- MONITORING FROM t-*-7_9 __ 0_6_.._0_1--1 YEAR MO DAY c20..21> (22-u> t24-25> PERls;>D 79 06 30 MO DAY (28-29) (JO-JI) DELAWARE RIVER GP AT Ml I 17 2

  • 11 I

NOTE: Read lnsirucllons before completing this form. (J Cmtl On/)*) QUANTITY OR LOADING (4 Card 011/y) QUALITY OR CONCENTRATION * (46-51) (54-61) (38-15) (46-51) (J4-61) NO. FRl'.~;NCY SAMPLE PARAMETER (J2-J7) l---'---'---~----'---~----1*--"'---':._-~---'--..;.....--~--'---'---~---~ EX ANALYSIS TYPE OC530 Li SOLIDS, TOTAL SUSPENDED EFFLUENT NET 00550 1t OIL AND GREASE EFFLUENT NET 00551 l PETRCLEUM t-IYOROCARDfiNS EFFLUENT GROSS 5C050 1 Fl.OW EFFl.UENT GROSS AVERAGE MAXIMUM UNITS MINIMUM NAME/TITLE PRINCIPAL EXECUTIVE OFFICER THIS DOCUMENT IS SIGNED WITH RECOGNITION THAT ICNOW-


f INGL'( MAl(rnG A FALSE CERTIFICA"(ION ON THIS REPORT OR SIJPPOH-rlNG DOCUMENTS 011 INTENTIONALLY TAMPERING Schneider, F. w.

wrrn ANY MONITORING DEVICE OR METHOD ARE CRIMINAL .JL.J'. - Production oFFENsEs. si:E 1a u.s.c. § 1001 AND 33 u.s.c. §1310. <l'en.. 1- '------1 'leJ* uml.:r the.~t! stt*l11/es llldJ' be /i11cs up 10 $11),000 u11tl/or lllUJ.:;11111m AVERAGE MAXIMUM UNITS 62.(jJ) (64-68) (69-70) 79 07 24 VEAR MO DAY TYPED OR PRINTED impr/l*o11111t*11t tJ/ bc:1we1.m 6 mtmtlu u11d 5 }'t11rs.) COMM~NTAND EXPLANATION ~F ANY VIOLATION~tt~~~Ufflrhuunuhen)

  • -~--------~~--------------~~~~-----~--~--~--~

PA Form 3320*1 (Aov. 10-77) f'O!EVIOllS EDITION i*o Ci! lf(;lifl 11.:.*i IL su.=-1~1.'." *tt EKll ',\\J*., r1:::1 r-n T"I, ,,n (IH':PLACES EPA FORM T-40 W!ilCll MAY NOT DE USED.) PAGE Or

PERMITTEE NAME/ADDRESS (ludwle NATIONAL POl-1.UTANT Dl.:iCltARGE f.'.LIUINAT~OM SYSTEM (NPVF.S) Fad/ily Narne/1"..,,n if diOere11t) DISCHARGE.:INITORINGl REPORT (VMR) !!A!il _ _p...!... ~_f__Q ___ ~ALEH_GENEHAflHg_________ <2~ 01-19> M!onrui _ _!l_Q__AR_.!5.___fLA.f_L_llOOM_JJ_ll 7_____________ NJ000562L F 6tJA NEWARK PERMIT NUMBER DISCHARGE NUMBER .=== Ni= 0110-1==========-~===~-=. DELAWARE RIVER NOTE: Read ln&lructlons before completlng thla form

  • PARAMETER (Jl-37)

(J Card Only) QUANTITY OR LOADING (4 Card Only) QUALITY OR CONCENTRAJION (46-jJ) (54-61) (18-45) (46...SJ) (S4-6l) NO. FRE~:NCY SAMPLE 1---"---'----.---"----'----....----+--.:._-~---.--...;_-.;_ _ __,r--....;...-...--~-..-----f EX ANALYSIS TYPE AVERAGE MAXIMUM UNITS MINIMUM AVERAGE MAXIMUM UNITS 62-63) (64-6B) (69_10) 00530 4 SOLIDS, TOTAL SUSPENDED EFFLUENf NET 00550 4 OIL ANO GREASE EFFLUENT NET OC55l 1 PETROLEUM HYDROCAIHIONS EFFLUENT Grrnss 50050 l FLOW EFFLUENT GROSS NAME/TITLE PRINCIPAL EXECUTIVE OFFICER THIS DOCUM!ONT IS GIGNED WITH RECOGNITION THAT KNOW-t--------------- INGLY MAKING A FALSl.i: CERTIFICATION ON THlti REPORT OH Schneider, F. w. ~~r.0~~1~~-1o~~~~~:~~TtE~1~E i~~E~~1~~i;1*_rRETAc~~~~~'!~ OFFENSES, si:i:;: HI u.a.c. § 1001 AND 33 u.s.c. §1319. (I""""'- SIGNATURE OF PRINCIPAL EXECUTIVE l--"-"-"'-~--....._.._,,,.~~w...~~-----l 1ie.J.' wul&:r tires'~.u1.1111tes uw,* /Jt: Jines,.,, to $10,000 11ml/or maximum TYPED OR PRINTED i1111>r/.w11111e11I <1/ />1uu*e,*n 6 m<1111/is ullll 5 J'Cur.r.) OFFICER OR AUTHORIZED AGENT COMMENT AND EXPLANATION OF ANY VIOLATIONS (il~*/'1e111.*" 111/ <1/111c/1111c11l.s lier<') DIS H9A IS 41191\\ (Rl'PLACES EPA !'ORM T-olO WlllCll MAY NOT BE USED.) 365-7000 79 '24 NUMBER YEAi:. PAG_E ___ OF--}}