Frederick W. Schneiaer Vice President Public Service Electric and Gas Company 80 Park Place Newark, N.J. 07101 201/430-7373 Production Mr. Victor Stello, Jr., Director U.S. Nuclear Regulatory Commission Division of Operating Reactors*

Off ice of Nuclear Reactor Regulation Washington, D.C*

20555

Dear Mr. Stello:

NRR INFORMATION REQUEST DATED MAY 25, 1979 PWR FEEDWATER LINES NO. 1 UNIT SALEM GENERATING STATION June 14, 1979 In response to your letter of May 25, 1979 transmitting the subject request which was received on May 29, 1979, we offer the following pursuant to items 1 and 2 with respect to design and fabrication history:

Design

1.

Isometric drawings of each steam generator feedwater*

pipe line from the containment wall to the steam generator nozzles shows the design, dimensions, pipe schedules, support types, location and pipe restraints.

There are no in-line valves in this section of the feedwater piping.

The steam generator sparger is internal with no* weld attachment to the steam gener-.

ator nozzle.

The Sparger has J tubes attached to the sparger header for flow distribution.

2.

A S1,lmm*ary of thermal and seismic stress analysis results performed for this system.indicates the stresses at the 9team generator nozzle and the location of other stress points including the maximum. *

  • 9 o s z 2 o s<or.

7

Mr. Victor Stello, Jr. 6/14/79 Fabrication History

1.

The steam generator sparger material is carbon steel.

The steam generator nozzle material is SA508 Grade 2 and the feedwater piping materials are shown in the tabulation attached to each isometric drawing.

The O.D. of the attachment to the steam generator nozzle is 16~" to provide for the difference in the material match to the steam generator nozzles.

2.

Welding details for nozzle to pipe and piping welds are shown in the attached tabulation entitled, Salem Nuclear Generating Station, Steam Generator Feed Pipe Field and Shop Weld Fabrication History."

There is no weld attachment at the nozzle for the steam generator sparger which is an internal slip joint.

This is the information requested within 20 days.

The additional information requested within 60 days is being accumulated and will be supplied subsequently.

Sincerely, Attachment CC Mr. B. H. Grier NRC, King of Prussia, Pa.

Mr. L. J. Norrholm NRC, Hancocks Bridge, N.J.

REV

. ~

NO. CAT A~

3f.sf7,

~11.T

  • l

. Y CUP>

!:WIE*

1.

ALL DIMENSIONS ARE IN FEET UNLESS OTHERWISE NOTED.

?..

  • 6li.A~C'.4 C.0\\-1\\.1.
. 41.L 12E.STl2b.l~i~* Lil.Ali siOPS 5110\\IJ~ 0>11.i FOR rl4el
!i.AA\\.

OSR.ECTIO~

DESIGN DIVISION ENGINEERING STRESS ANAL.

DESCRIPTION COMMENTS OWN CHK VER COMMENTS CALC VER IDAT Ti?ICAL \\40ME\\..lC.\\..lffU(2E

  • <'p, II He. p 4.D *r.

s G5

z. = 6LEMCl-1T ~o.

l--0---L.. ST~eS> "O* \\)OIWT I

s @

'Z.

. 5T!ZESS No. f'Ol\\..IT.

5

( f..Ab."-iS.l?.)

+

SUl"i'O!Z.T 01t IU!~TU1~1

\\.OC. "O, s

~ :. ~\\~E R.uW TC~Mll.IAT101.J fo1~T

. - (A )-*;I;: MATEIZ.J.At.

-~ --?rz.e *... ~_ ------*-

I 055\\G\\JAilON 11-SGF-I : CE:i~OO\\.. PIEC.E 1-AA\\"Z~

(FW* i;£KF'*.):: ~lELt>WELO MA\\:Z"-

0

SHOPWe\\.'O Vi~~~

~

-~-

ft~

PIPDYN 7!,

THERMAL Yi~,

.PIPDYN SEISMIC I REFERENCE DRAWINGS ARRGT.~

DIAGRAM. __________

~

HGR.LOC. __.. --------

HGR.DET._

LG. SP. LOC. ________

LG. SP. DE T. _______ _.,,,..,,..-

SM.SP.LOC. _______

SM.SP. DET.*

INSULATION _.

CONST. ISO. ________

E.C.N.' S _________ _

NO.'LUNIT CALC.-------

SALEM NUCLEAR GEN.STA. NO. 1. UNIT eeACTOla C,O\\.IT~1>1MEt-.1T B1.oi"z.

STE.ii.\\ GEN. FEeOWATE2

~....._ A\\.lC:llOR e CO\\..IT41\\o..IME~i WAI.I. SLI/,

  • 5 TO CONIJ, ~ 6 II STEAh'. G51.1E~TOR.

2G7171 Sil. I "i' 4

i i

I J

j i,

J r(UP) 1.~.r-

. --:~...... --**'-"

I- $G'f*47

(!=') #

.ooo o.o*.

)

~

I' *

.,..,, I..... ~*

I.

      • '*?~ ~"'*

267171

~*-- ------

" )

I

i.

)

I


~

CONTD. ON CALC~

ZS7171A

~.. -:

1

.... ~. :.: :.*~,...

~ '.

~ ;.-*

  • ~

I 267171 s~. 3 °" 4

...... ~

~* '.

(F)

II

/4.000 o.o.

. 750" N'..

(.J)

)

-- r-----..... ***--*-*-*--* ***-** -***... **-**

~........ -

y

- :*")*

.* j.-.

.. ~*-;.

l. ;*.

I.

/o' 3 H.R. /NSUL.

SEMI* £/'JCAP.

(c)

(E) y 16.SCOO*P. 1<;;.000 o.D (A).,

1&.000 d.Q

.5... '.)21°' w

.ST>( t;EJJ.

JJDZ.ZLC

--r--

0 0 c 267171 s~. 4""" 4

    • ": '4

--~-,

I.

f**,. -~. '

I I'

..... f O.D.

W. TMK.

'2~.00~ "

)

~.02. I lA B)

(_ C.)

/(.,.t/.l5..

2.or,,,,3' (P)

/ f')

( E.)

(G)

(fl)

(J)

(K) tcP. Goo H

/{,p,()t)IJ.

/4.~t"C

I(,. IJoo "

'], '2 so

/, '315 14.000

. 927"

/, 5<;>3

. 750

.574

. £'2.G.

.'250 I*

.150

~ED. EC s /7 J;L.1.A I.

~9~'?>

/I

)~0 t!J t>

II

,j f'U1.lf O:.

II Fo~"o

'U.~ STOC.\\('.

160

-~,,

-So

/I IC.../'z 'IC 14 l?eO.

11 I

c EH TEMP

?op '27.1o7 I}

II

{l II

//

fl II II Jr

. )*

H ri~Ut:],t~

TEMP P.~.t-470° /£!;70 JI

. II II II II

  • I I I l

I I

MATE.RIAL THERMl\\L EXP. COEFF.

S~(P.S.t.)

l/ 508 CL.ff lbe~1,{J~.o?J!rl-1 /rr.

.oo'1.78 (,I/

3~ 000 A*/1)6 c;P.C

~

I h

2012~

JE~'"'f.

JI II A*

12 :,4 WP C...

A* IO~ (Y(Z. C.

~t=J.i1-L II A* 105 Gr(?. TI II II A* I O(Q G-12. c..

IJ

/J A- 'l3't WPC I/

A- 'Z934

~IPC..

2b717 (

SI-\\. 3 or: 5

~

' I,

e I

,I

.~

'SAL~M NUl-LEAR r-:~r-J. C,TATJn rJ UN IT I

~.

S'iS1EM S-rcAM G-EN. !-EEDWATER F1PJN6-CA L.c; ::l\\=l s-r~e:ss

'2blt*lJ MA'i.l MuM 5TR~s.s.(es1)

W01z. L£" 5 "f g f:SS E:.S kll_g Loc.AT10N oF

,";"\\

{)BE C:/\\ Rnt&UA~e:

.CD i I ;

12:'

":'2)

\\,._)

s*n~tsc; -

~

-/"'

y J

x.'--r~'- h+L.z.

0onl14f ~~~\\tJef \\~El6HT !H~~~I *X 2

\\

R.\\;~Yt

'2 "?7 4-b97 3E>3

~21S 7..68 7..bCf fbo

go

"~'

IBbB 4-Z}a8. 'B' I

I I

. s

¥CJ1** '253. 3 t;Sb hol 817 (02. 7 l4-f'2.

I?;.§}

l4q18

~21 188

.. ;sf 1,

_,~

4bql fl.1S

~B~

S:;3 14 51 4-~1 tS-B *202

?.1.

tqg 2lBo

!080 S~Z-b l4 *74' 3

4tl~/

lbo

~/4'i 9~7. cogl, 11;0 15B2-M-5313

~~188 f-6 1#1-1.~ +0 5~ t-e7 4~S 460 bbb l4-7 li.7 BCJ. ~Ot>O

  • 2~'

ef~<"~~R~ -I-QEAlH~~ElGdI :f: 1HE:KHak + ltter~R Of J X~i'*o~

...'*© ff1:,*7,.~

G;)

S:n+/-~~ As Af2l!l..£S.'*~~

lN >ALE~ F~~**. t4.c;.3.l

  • " -y D~NOTC::S ND'Z-£LE:

.STf?E:SSE:S AND t'eE"ssuee srQ.E:ss tS Bf\\~C:D DN,_l\\95 ~~-' Af{Q.

  • 51_4-__ ~_~LJ~ Tf{;c~t,J£:-:-?_~

Peeruc:p Bi Tu?

Dh1e

(;.17;.17 Cttecl(e,p B'f ~,J.

DArc:

6/l~h' l

I

\\fE:J?,tf 'E.I> Bf l24K DATE". t,/;3/zr

SALEM NUCLEAR GENERATING STATION S'l'RZ\\M GENERATOR FEED PIPE FIELD Al\\TD SHOP WELD FABRICATION HISTORY (l}

JOINT ID (WELD TYPE)

( 2 )

WELD PHOCESS{ES)

(OF)

PREHEAT (OF)

POSTHEA.T FINISHED WELD STEA..'11 GEiii.. NO.

SPOOL NO.

(3)

(4)

J.T.

NDE 11 l-SGF-45 11 l-SGF-45 11 Field Weld 11 l-SGF-46 11 11 11 11 11 11 11 11 11 ll l-SGF-46 l-SGF-46 l-SGF-46 Field Weld l-SGF-47 Field Weld Field Weld.

l-SGF-48A RW l-SGF-48A RW l-SGF-48A RW A (ATTACH)

B (ATTACH)

SGF-45-24B (BWI)

A (BW)

B (BW)

C (BW)

SMAW sw..w GTAW-Root; SNAW-Bal.

GTAW-Root; SAW and SMAW Bal;.

Ditto Ditto D (WBU)

SMAW*, SAW SGF~46-25B (BWI)

GTAW-Root; SMAW-Bal.

A (BW)

GTAW-Root; SAW and SMAW Bal.

SGF-47-26B (BWI)

GTAW-Root; SMAW-Bal.

SGF~48A-52B (BWI) GTAW-Root; SMAW-Bal.

C (BW)

B (WBU)

E (BWI)

GTAW-Root; SAW and S.MAW-Bal.

SAW GTAW-Root i sz;.w and SMAW Bal.

60 60 175 Root 400 Bal.

200 60 60 175 175 60 175 175 200 175 50 1150-1200 1100-1250 1100-1250 1100-1250 1100-1250 1100-1250 1100-1250 1100-1250 1100-1250 NOTES: -(1)

Reference NRC request for info on PWR Feedwater Lines dated. 5/25/79.

MT MT RT and MT RT and MT RT and MT RT and MT RT and MT RT and MT RT and MT RT and MT RT and MT RT and MT RT and MT RT and MT (2 ) (ATTACH) =Attachment Weld; (B.W.) = Circ. Single Butt Weld No Backing* Ring; (B.W.I) =

Circ. Single Butt Weld with Cons. Insert; (W.B.U.) =Weld Build-Up (3 )Shop Weld Filler Materials: GTAW-E70S-2; SMAW-E7018; SAW~F72-EM12K.

<4 >Field Weld Filler ~taterials: GTAW-EB,Insert M$l; SMAW-E7018 (Except as noted).

  • e

STEAM GENERATOR FEED PIPE FIELD AND SHOP WELD FABRICA'l.'ION HISTORY (I)

!WELD PROCESS{ES)

~

FIN IS HED WELD STF~

..... 'lwl. GEN. NO.

SPOOL NO.

JOii~T ID (2 )

(WELD TYPE}

(3)

(4)

(OF)

PREHEAT

{OF)

POSTHEAT J.T.

NDE 11 11 11 11 11 11 13 13 13 13 13 13 13 l-SGF-48A RW l-SGF-48A RW l-SGF-48A RW l-SGF-48A RW l-SGF-48A RW Field WeJ.d l-SGF-62 l-SGF-62 Field weld l"'-SGF-63 l-SGF-63 Field Weld l-SGF-64 F (BWI)

G {BWI)

H (BWI)

K (BWI)

J (WBU)

GTAW-Root; SAW and SM2\\W Bal.

GTAW Root; S.Mi"\\W Bal.

G'I'AW Root i SMAW Bal.

GTAW I

SMl~W SAW Root; Bal.

50 1100-1250 50 1100-1250 50 1100-1250 200 1100-1250 175 1100-1250 SGF-48A~27B (BWI) GTAW Root;*

175 Root 1100-1150 SMF-.W Bal. {E8018C3 I 250 ~l.

A (ATTACH) s:r.mw B {ATTACH)

S:t-1AW SGF-62~34B. (BWI)

GTAW-Root; A {BW)

B (WBU)

SGF-63-35B-A...:l (BWI)

A (BW)

Sl.i!AW-Bal.

GTAW-Root; SAW

  • and SNAW-Bal.

Slw".iA, SAW GTAW-Root; SMAW-Bal.

GTAW-Root i SAW and SMAW-Bal.

60 60 175 200 175 175 Root 400 Bal.

60 1100-1250 1100-1250 1150-1200 1100-1250 RT and MT RT and MT RT and MT RT and MT RT and PT ~n MT RT and MT MT MT RT and MT RT and MT RT and MT RT and MT RT and MT NOTES: (!)Reference NRC request for info on PWR Feedwater Lines dated 5/25/79.

<2 > (ATTACH) ~Attachment Weld; (B.W.) = Circ. Single Butt Weld No Backing Ring; (B.W.I) =

Circ. Single Butt Weld with Cons. Insert; (W.B.U.) =Weld Build-Up

{3 )Shop Weld Filler Materials: GTAW-E70S-2; S~lAW-E7018; SAW-F72-EM12K.

C4 >FieldWeld Filler Materials: GTAW-Ei3 Insert MSl; SMAW-E7018 (Except as noted).

t'-f11J:..~LJ'I U~

... ~J;J\\.1.-i'.

~,t;.~t,li!JA'.l.' L~G ~:.t-:..'£J!,)J:.i STEAM GEl.~ERATOR FEED PIPE FIELD AND SHOP WELD FABRICATION HISTORY (lJ JOIN'l1 ID WELD PROCESS(ES)

FINISHED WELD STEAM GEN. NOo SPOOL NO..

(2)

(WELD TYPE) c~'

-* J (4)

(OF)

PREHEAT (OF)

POSTHEAT J.T.

NOE 13 13 13 13 13 13 13 13 13 13 13 13 13 13 l-SGF-64 l-SGF-64 Field Weld l-SGF-66RW Field Weld l-SGF-66RW l-SGF-66RW l-SGF-66RW l-SGF-66RW l-SGF-66RW l-SGF-66RW l-SGF-66RW l-SGF-66RW l-SGF-66RW B {BW) c (WBU)

SGF-64-36B (BWI)

A (WBU)

SGF-65-37B (BWI)

A (BW)

G (WBU}

s (WBU) w (WBU}

Q (BW)

I\\ (BW)

T (BW)

R (BW) p (BWI)

GTAW--Root; SAW 60 1100-1250 RT and MT and SMAW-Bal.

SAW 175 1100-1250

.RT and MT G'I'AW-Root i 175 RT and MT SMAW-Bal.

SAW 175 1100-1250 RT and MT GTAW-Root; 175 RT and MT SMAW-Bal.

GTAW-Root; SAW 200 1100-1250 RT and MT and SMAW-Bal.

SAW 175 1100-1250 RT and MT SMAW, SAW 175 1100-1250 RT and MT S.f:l.!.AW, SAW 175 1100-1250 RT and MT GTAW-Root; SAW 200 1100-1250 RT and MT and SMAW-Bal.

GTAW-Root; SAW 200 1100-1250 RT and MT and SMAW-Bal.

GTAW-Root;

. 200 1100-1250 RT and MT SMAW-Bal.

GTAW-Root; 200 1100-1250 RT and MT SMAW-:;.Bal.

GTAW-Root; I

SMAW-Bal.

175 1100-1250 RT and MT NOTES: (1) Reference NRC request for info on PWR Feedwater Lines dated 5/25/79.

<2 > (ATTACH) =Attachment Weld;. (B.W.) = Circ. Single Butt Weld No Backing Ring; (B.W.I) =

Circ. Single Butt Weld with Cons. Insert; (W.B.U.) =Weld Build-Up (3 ) Shop Weld Filler Mate~ials: GTAW-E70S-2; SMAW-E70_18;. SAW-F72-EM12K.

<4 >*Field Weld Filler Materials: GTAW-EB. Insert MSl; SMAW-E7018 (Except as noted)*

e

~;.,

>>1

  • 1
  • I

~ i

~:

  • I ii I

.!1 h1

.;I e ii H

d

j
  • i

!I I

1 f
I
  • I
I
1 I **I
  • 1

ST!:XIVJ. G:i.lliERA'l'OR FEED PIPE FIELD AND SHOP WELD FABRICATION HISTORY (l)

JOINT ID I

WELD PROCESS (ES)

(°F)

(°F)

FINISHED WELD"'

~S~T~*EAM::.:..:=--=G~EN=-=-*-=.:N~O~*-+--=-S~PO~O~L=-=!~~O.;;....:_*~~WELD TYP~E~')t....-_(

2_)~~-~-(~3~) __ _..i...:4=-'-------~P~R~E~H~EA:::.:..::T=--~P~O~S~T~I=IEA::.::..:T=--1--~J~.~T~.-----=N~D~E~~

13 l-SGP-66RW D (WBU)

SAW 175 1100-1250 I 13 Field Weld SGF-66-38B (BWI)

GTAW-Root; 175 Root 1100-1150 12 l-SGF-30 A (11.TTACH) 12 1-SGF-30 B (ATTP.CH) 12 Field Weld SGF-30-16B (BWI) 12 l-SGF-31 A (BW) 12 l-SGF-31 B (BW) 12 l-SGF-31 c (BW}

12 l-SGF-31 D (WBU}

12 Field Weld SGF-31-17B (BWI) 12 l-SGF-32 A (BW) 12 l-SGF-32 B (BW) 12 Field Weld SGF-32-18B-A (BWI)

SMAW-Bal.

250 Bal.

(E8018C3)

S!-1..AW SMl\\.W GTAW-Root; S!vlAW-Bal.

GTAW-Root; SAW and SM.Z\\W-Bal.

GTAW-Root; SAW and SMAW -Bal.

GTAW-Root; SAW and SM..l\\W-Bal.

SAW G'rAW-Root; SMAW-Bal.

GTAW-Root; SAW and SMAW-Bal.

GTAW-Root; SAW and SMAW-Bal.

GTAW-RQot; SMAW-Bal.

175 Root 400 Bal.

200 60 60 175 175 60 60 175 1150-1200 1100-1250 1100-1250 1100-1250 1100-1250 1100-1250 1100-1250 NOTES: (l) Reference NRC request for info on PWR Feedwate.r Lines dated 5/25/79.

RT and MT RT and MT MT MT RT and MT RT and MT RT and MT RT and MT RT and MT

.RT and MT RT and MT RT and MT RT and MT (2 ) (ATI'ACH) =Attachment Weld; (B.W.) = Circ. Single Butt Weld No Backing Ring: (B.W.I} =

Circ *. Single Butt Weld with Cons. Insert; {W.B.U.) =Weld Build-Up

{3 )Shop Weld Filler Materials: GTAW-E70S-21 Si~\\W-E7018; SAW-F72-EM12K.

C4 >Field Weld Filler Materials: G'.l'AW-E~ Insert MSl; S.MAW-E7018 (Except as noted)*

e e

I i.

~

i i

f II -f j

I

~ ;.

j

~

I

STE.t-1.1\\1 GE.NEAATOR Fl.E:D PIPE FIELD AND SHOP WELD FABRIC..~TION HISTORY (l)

WELD PROCESS(ES)

STEAM GEN. NO.

SPOOL NOo JOINT ID (WELD TYPE)

( 2 )

(3)

(4)

(OF)

PREHEAT (OF)

POSTHEAT 12 Field Weld SGF-33A-51B (BWI) GTAW-Root; S.MAW-Bal.

175 12 12 12 12 12 12 12 12 12 12 14 14 NOTES:

l-SGF-33A C (BW)

RW l-SGF-33A -

B (WBU)

RW l-SGF-33A RW l.:..SGF-33A RW l-SGF-33A RW l-SGF-33A RW l-SGF-33A RW l-SGF-33A RW l-SGF-33A RW E (BW)

F (BWI)

G (BWI)

H (BW}

K (BW)

J (WBU)

AA (WBU)

GTAW-Root; SAW and SMAW-Bal.

SAW GTAW-Root; SAW and S.Ml\\.W-Bal.

GTAW-Root i SAW and Sl~W-Bal.

GTJl.W-Root i SMAW-Bal.

GTAW-Root; SMAW-Bal.

GTAW-Root; SAW and SMAW-Bal.

SAW SMAW 200 1100-1250 175 1100-1250 50 1100-1250 50 1100-1250 50 1100-1250 so 1100-1250 200 1100-1250 175 1100-1250 60 1100-1250 Field Weld SGF-33A-19B (BWI)

G*TAW-Root i 17 5 Root 1100-1150 SMAW-Bal. (E8018C,l 250 Bal.

l-SGF-14 A (ATTACH)

Sl'-lAW 60 I l-SGF-14 B (ATTACH)

SMAW 60

{!)Reference NRC request for info on PWR Feedwater Lines dated-5/25/79.

<2 > (ATTACH) = /i.ttachment Weld; (B.W.) = Circ. Single Butt Weld No Ba-eking Ring; Circ.. Single Butt Weld with Cons. Insert; (W.B.U.) =Weld Build-Up (J)Shop Weld Filler Materials: GTAW-E70S-2; S~AW-E7018; SAW-F72-EM12K.

~,INISHED WELD NDE RT and MT RT and MT RT and MT RT and PT RT and PT RT and PT RT and PT RT and PT RT and PT and MT RT and MT RT and MT MT MT (B.W.I) =

<4 >Field Weld Filler ~terials: GTAW-E~ Insert ~.LS!; SMAW-E7018 (EX:cept as noted).

L

~..:d;r.l'J.l l.~ Ul.,.. L1&;;.'\\J;j, k~'J.t;..,t\\j\\'.J.'..J.J.'/Y-!~~

STEAM GENERATOR FEED PIPE; FIELD AND SHOP WELD FABRICATION HISTORY (1)

JOINT ID (2)

WELD PROCESS(ES)

(OF)

(OF)

FINISHED WELD STEA..~ GEN. NO.

SPOOL NO.

(WELD TYPE)

(3}

(4)

PREHFAT Posr.rHEAT J.. T.

14 Field Weld SGF-14-7B (BWI)

GTAW-Root; 175 RT and MT SMAW-Bal.

14 l-SGF-15 A (BW)

GTAW-Root; SAW 200 1100-1250 RT and MT and S.MAW-Bal.

14 l-SGF-15 B (WBU)

SP..W 175 1100-1250 RT and MT 14 Field Weld SGF-15-8B{BWI)

GTAW-Root; 175 Root 1150-1200 RT and MT SMAW-Bal.

250 Bal.

14 l-SGF-16 A (BW)

GTAW-Root; SAW 60 1100-1150 RT and MT and SMAW-Bal.

14 l-SGF-16 B (BW)

GTAW-Root; SAW 60 1100-1150 RT and MT and SMAW-Bal.

14 l-SGF-16 c (WBU}

SMA, SAW 175 1100-1250 RT and MT 14 Field Weld SGF-16-9B (BwI)

GTAW-Root; 175 RT and MT SMAW-Bal.

14 Field Weld SGF-17-lOB(BWI)

GTAW-Root; 175 RT and MT SMAW-Bal.

14 l-SGF-18RW A {BW)

GTAW-Root; SAW 200 1100-1250 RT and MT and SMAW-Bal.

14 l-SGF-18RW c (WBU}

SAW 175 1100-1250 RT and MT 14 l-SGF-l8RW E (BWI)

GTAW-Root; SAW 50 1100-1250 RT and MT and S?l..AW-Bal.

14 l-SGF-18RW F (BWI)

GTAW-Root; *SAW 50 1100-1250 RT and MT and SMAW-Bal.

NOTES: (!)Reference NRC request for info on PWR Feedwater Lines dated 5/25/79.

<2 > (Nl'TACH) = Attachment Weld; (B.W.) = Circ. Single Butt Weld No Backing Ring; (B.W.I) =

Circ. Single Butt Weld with Cons. Insert; (W.B.U.) =Weld Build-Up

{J)Shop Weld Filler Materials: GTAW-E70S-2; SMAW-E7018; SAW-F72-EM12K.

<4 >Field Weld Filler Materials: GTAW-EB Insert MSl; SMAW-E7018 (Except as noted).

NDE e

e

1l 11

!1 I

j

-~~..J~*~s.~~~~*,:<<..__,..~

STEAM GENERATOR FEED PIPE FIELD AND SHOP WELD FABRICA'rION HISTORY\\Tf

~

(OF)

(OF)

JOIN'!. ID (2)

WELD PROCESS{ES)

FINISHED WELD -

STEAM GEN. NO.

SPOOL NO.

(WELD TYPE)

(3)

(4)

PREHEAT POSTHEAT J.T.

14 14 14 14 14 NOTES:

l-SGF-18RW K (BWI)

GTAW-Root; SAW 200 ll00-1250 RT and MT and SMAW-Bal.

l-SGF-18RW J

(WBU)

~

SAW 175 1100-1250 RT and PT l-SGF-18RW H {BWI)

GTAW-Root; SAW and SMAW-Bal.

50 1100-1250 RT and MT l-SGF-18RW G {BWI)

GTAW-Root; 50 1100-1250 RT and MT SMAW-Bal.

1-SGF-lSRW AA (WBU)

SMAW 60 1100-1250 RT and MT Field Weld SGF-18-llB(BWI)

GTAW-Root; 175 Root 1100-1150 RT and MT SMAW-Bal.. (Ea01BC3) 250 Bal.

(l)Reference NRC request for info on PWR Feedwater Lines dated 5/25/79.

(2) (A'I'I'ACH) =Attachment Weld; (B.W.) = Circ. Single. Butt Weld No Backing Ring; (B.W.I) =

Circ. Single Butt Weld with Cons. Insert; (W.B.U.)==Weld Build-Up (J)Shop Weld Filler Materials: GTAW-E70S-2: SMAW-E7018; SAW-F72-EM12K.

<4>Field Weld Filler Materials: GTAW-EB Insert MSl; SMAW-E7018 (Except as noted).

NDE and MT e

REV NO.'bATE

~-:.

'!.~

"""-T 7(,

I I

I I

I I

. y <UP>

l:l..Ql.L ALL DIMENSlONS ARE IN FEET UNLESS OTHERWISE NOTED.

z. @ = B\\Uif.IC.14 coi..iw.
3. ALL \\Z.E')"[\\2lil\\..ff5- \\..\\MIT SIO?':i Sl-\\0-!IJ Cl..IL'i FOZ 1\\.\\EZJv\\AL CE\\:LECTIOIJS DESIGN DIVISION ENGINEERING STRESS ANAL.

DESCRIPTION COMMENTS DWNCHK VEP.

COMMENTS CALC VER 0.0..TE T)'Plc..6.L 140\\..Ae\\..lCLl:li'U<Z.E

~

E:C.l-l.. 7'23<'.;,

I s

l. -:: EL-EMEi-iT l-.10.

i I

I i

T---o=----t. :

STIZ.E c;.S NO. P01\\.:il I

I 1

i

~:

S.11ZESS f..iO. pol~T-f4

(\\..At:.<;TE'Z)

I r,-.~ -: 5uf'f'O~T 011:. \\ZBTt?A11Ji 1...oc. \\..10.

)

£: f \\VE \\U..I ~ i'E:tzl.A1..U. ~

c l'01\\4T

-. -* J..A) --* 1

'"J. "Ml\\Te!ZI AL Ii: S\\'Z.E I

... _ ---*-~ ---

\\>ESIG\\.J~TIO\\.J 11-SGI=* I : $'?00.... l"'IECE MAl?K (FW* SGI= * ) : l=\\6LDWELD MA~I<

0

'5\\.\\0f>WS.O MA!?K I

(j)

PIPOYN

  • Z~

.~;

THERMAL

'h!.1 PiPOYN 17$

SEISMIC r. _1 REFERENCE DRAWINGS s=r-*r:rrmr===

n:iET4~

ARRGT.,....

DIAGRAM __________

~

HGR.LOC._

HGR.DET._

LG. SP. LOC. _________ _

LG. SP.DET. ________ _

SM.SP.Loe._

SM.SP. DET._

INSULATION_

CONST. ISO. _________ _

E.C.N.' S -----------

NO.'l UNIT CALC. ______ _

  • --5?EC. 1$* l~A 5EISl.AIC. t f.lUCl.E6'2 '[

SALEM NUCLEAR GEN.STA. NO. l UNIT!

'i!Et.C.TOIZ c.mmw-IMEl-lT a1.0Cr.

STEt.>-.\\ GEl-lc.u>10\\C'. ;:et:owtiTE:Z.

I i='l.ON'I 6:~C.l.IOC. @_ CO\\.JT!i.11.JME\\.[i l'Jt.tl Si."'" "'

EL.')'=;. 1 ~;i 10" ro ~i-li.l..a & 1'2 sT1.1

~E'..lt::U70't I el I

267/72 S<-l. I., 4

y

( _,p I

  • -~--.

267172

)

)

~\\

l A5 13U\\Li~

I \\

tJ)

'(

t

... ~- -~-

.,_,*~,

207172 Sl-l,3<>F 4 j

-,-1 Y(uP)

FW-SC.F-33A* ICJB

)

267172 I

{A)

8)

{C)

.£)

(G-)

~4)~

lJ)

(\\-()

I -

o.o.

21,,,.000 11

/~. 0'25

.5oo I&,. O/Jt),.
14. o~D
&.ot~

'2.'2SO 1.315 14.coo

!J\\'"1&if5* g

~Wt~.~

W. T~K.

s.021

'2. oc..J

  • ".Jc7

/.t;93 7~0

. ~ 74

. 8'2.0 p

. '250 II

.150 I

~HE'D. -EC

.5,P~I~{

I 19-9 It

\\ I I 1 I,/

l&d)

/I bD i,,

j;~c,,-fJt i=oQG E.0

\\

Bll e. s Teo.:::

i,,

I

_\\GO J '*

Bo II IC.. 'h 'i: !Or II

- IZE:D *


~--------------------------------:-1 c

EH I

\\>4TEMP r/~[.S:S MATE.RIAL TNERM~l ~XP. COEf=f-!'.

SA()).~.'I.)

TEM~

r.~.1,)

70*

1. ~ t,,-1 I* ;,.1 -

~

'*.* /0 1'350

/1508 CL JI,.c;

..£4 //./tf. o.o~ 41;;.. J, oo'.2 7 !5 ~tJ-3 0) aoo

/I II l 11

/I

/1 -10,::, r;rc:.. 5~r-J;..(,

~

//

2b;25<1 I I

,/

I II If I I If

/I II II A- '234 WPC N

11 (l

I I

11 j/

A* l©~ r.e.c I

I S GAl-4.

11 I/

11 I

l It

/J.-105 G\\2. II l

l

/(

11 I*

A* 1oc; 6R-C.

II

/I I

I A*'l..34 WPC.

II 11 I/

/I If L__

I 11 I

A-7.'34 WPC I II 11 I*

I/

.e 2b7l72 STRESS C,l\\LC. NO. LIST "2. ~

ITEM NO TA8Lf:-


.,---~=======~--=-=-=-===------*~~~~

UN IT WJ_cF.__ ___ r-__,_~ 1::_r.J. s *uT.~~-----l

.

  • I /

1 Sic: AM

\\

&e:f k&G"P Bi -Di>

P,\\re fo -tl- ~1 ~

1 B'! ~frJ

  • l28I£:

6 Ll"J> h~

c. {-i C: c;__I.J' e,p

~

~'-

l

(

\\/t:R!f \\ED B~~

DATE:

t~2/.7$.

I e

. e

jRE vJ I NO.D4TE

  • S

}le,h-.:

"l~ILT I

I Y <UPJ J:illli.;_

1.

ALL DIMENSIONS ARE l~J FEET UNLESS C:HERWISE NOTED.

'2.

  • GQAl-KH C0~~-
  • Lh

~45' a~

0 hs

-~-----~

PIPDYN THERMAL PIPOYN SEISMIC I

3. !.\\.\\_ 1?.EST1Ul1\\.HS - UV.IT <;,TOP~ <;HQWIJ O"-IL'i FOR. T'.\\ERWll_

DEFl..ECTIO~:,

DESIGN DI VISION DESCRIPTION COMMENTS r-rric'-'>L-i...ioJ..AENC.lt.Tu<zc c, (])

'l. = ELE.M51-4T NO.

~=

STIZ.ESS NO* \\'01\\.JT r-@:-c. = STfl.ESS NO. 1'01'!--lT 5

(.\\.Vo.C.Tt;I<.)

~=

s1..1 ?~otLT o;c. P-EST(Ui.1}1T LOC.. NO.

s t~ f'll'E ~\\J~ i'C~N\\1'1.Umoi-11

\\>01'f-l,T I ~~

.. $~**~-*-=E--.

I t:>S';>IG:\\.lATION 11-SGF* I = SPOOL ?IEC.t::

<-Ill\\;{~

Gw* SC:\\='* ) -:: !=ll:LDWc\\X> Mb.'?..'t.

0

S\\.lO?WElD

~~llt.::K I

,f OWN CHK VER I I i I I !

ENGINEERING SlRESS ANAL.

COMMENTS CALC \\/ER DATE REFERENCE DRAWINGS

~,...=m-=.......,*==-

c::sc:ma:m:;c-ARRGT *~-

DIAGRAM __________

~

HGR.LOC._. _

HGR.OET. __

LG. SP. LOC. _________ _

LG. SP.DET. _________ _

SM.SP.LOC. __ _

SM.SP. DET._

INSULATION _

CONST. ISO. _________ _

E.C.N.' S -----------

NO.'l UNIT CALC. ______ _

  • -* SPEC. 15* l-:OA SEISMIC-! NUCLE.i!Z iJ.

SALEM NUCLEAR GEN.STA. NO. i UNIT!

Rl':llCTOI<

CO~T41\\.JME:NT BUX:r.

STE.t>M &c\\.lE'2t.TOl<. ;:e~o*Nc.T~e FlZOM t.\\.lC\\.lOR 2 C.()\\.ff~l\\..lMEf.lT W<llL S\\.\\J d, 7 I

@EL.")((,*- 8/'4. TO COt-.1i:J @

  • 1'3 STM GE\\.JEl?~TOP-.

267173 S'r-\\. I*>= 4

~~

. -~,~:t~ **ffl~~~~-~"9l:*1~:i~'g(l;;~~:i::Jr.~s;.~:cn~';:t :~:::::r::;:::~::.:*:.::~:2:~:::::,;:~:.. :2~~%,."~:~~=";J

)

~*........ fr./;.******.;:,... '*

~

267173 S!-\\.'Z<>F4-

I \\*?Gil=* <Os I

)

267173 t)

....J.

i I

~ !

~j

~

~....._. * ***A~I

y(u_P)

' )

FWJJR. -104 PIP!:-

'2..\\JPT\\JR.E. I<. 5TR.A.1t-.:r WGi T. I ZO L ?.

y

<::).

--, o*

&-' ~

0" 00 ~

I.Ji° VJ

x. -/'

~-=*--**

/-fort!#E.V/ 6',a- ~3.57-£/?n' ~c~ro.e.

-lc" r0u. L~Ao

"*--* )/o h~o

<,,,c:::.-c -;;;:tt",e;~AJ'- ae Ovt.r) 267173 Si.I. 4-or4

~

l-rI

'1 1

I J

A 13 c..

0

£

f.

I G.

I (.J)

(I<)

o.o.

W. THK. OCHED.

EC c

EH 14 iEM~

TEMP 2(;.ooo "

5.oz1" 6P~*

V~-CJ 70° 2 7, (:, 7 470" J(.,.CP2'5"'

'2. o!P3

I(

II 1 r..,., ooo

/, 5 CJ 3,.

/~O II II

,~74 5,.oc;c.

1(,. () ()0

14. CC'tf
  • 7,;o go FOfU.SO

'2.'250

. 8"2.G.

~12 ':>ToC.K

\\. :i l 5

. 'l. 50

\\~O I

14.oao

.lS'O 80 II 0 I f.593..

\\Ci,. 000

\\ G:,O q 0 JI

(

$~= \\7.~00 PSI ( Pl?E:)

~ (F1TTl~\\C"-,,.')

J P.R~S~)~

~f\\~TE.Rl~L TiiERM~\\.. 'i:J\\P. COEJ:Fo

( f', ~. r., L.

iti 70 IAsoa a.JI /Ve41A.Jt;

.()C2.7/ii"/,N

  • 0334-1 /r,;

I' I

~

A1ol t;,e c.* 5EArt

  • II

/(

A* 'L?; Lt W?C If A. I 0 ~/{ G \\2. c. S&/\\H I I It y

ii A* 105 GR.. IT

!::.. toi:; GR.. C..

/I Q I A* '2.34 WPC..

A I Ob GR' C.. 58\\H 2G7\\73 Sl\\(?.S.!,)

3o1 ooo

~b, 250-ti

/(

I

-l

  • l

.~~*~~-~so

.......,,., * -.-*~--------*-------------------)

e.

t' *

'" 2ALE:l"1 N\\L.C(-,.<':1 R &£f\\f. STATIQ N Uf\\JIT

.. \\ l SjSTE'M \\ s-n:AM GEN-FEEDWATER f'w1NG-1 Srr-i::ss Ciu.. c. ::lf\\

2 b 7 ! 7 3

~~~----~WT

-Z

""""""-~---=---~--~-----*

~--

  • . - ti~~t-~-

s1--R($sE:"s f.\\-i\\IP Locl\\TUJN *Q,E MAJ\\.! MuM 5TRE"s:s(fs1)

~~~:::oa;;oz

..... w

'a-=~~....:::fl~~

.... ~~=-==

('**'

w J

-A-t"0

(;"'\\

\\J {2) ! *:v

.~K-~<JJ\\icJ9Ei~LxJ y_ L~.:..-~: ~~,

~~*~~~~~.~

.fu,!

121*10 I J S"fbl t-==l====

I yti'.1Ll21..J.. :l~J~~~L~!~6~

1~04-1?J4i,1iB' *2'14

  • f 1s i~L~~ ~=t~.:J12£~J~~ 25'~212-t~~'/55 to""~l~

. L~~~.J~=r=--~~~-

. __J_~. ~~L=~i~L==1=~[

__ ~L~

I

  • cp ~~~t lfis£MAL i* Ll'rtrft'R. of J x'+/of\\ Ji':i--z..,_

$,,.~.+ <;~s._g,r.i1.d;.il-;~;-~n n,{ SA~~:J ~s-~

  • di. t;.]2.,.__ _____ _

1

_ ~ u-Q.r;;f'.itJ""fG..S ND7--ZLE°: *-.S."fG?ESSES ANP L. -

fei:;~suQe;.s-rRe::ss A.S BA;-':'20 oj\\r, 095 ?~_UillD.,,,,:..~J!L..~lALL Tc\\1c1<~J£.:-:? __

  • -.pg?f£<&~._B~~

Dru-_~. fo:JL.:-1.<J~

r u c:

  • 1"".
  • Bd r~~ ~
  • 11...-*r\\c.-C..t1.... ~D

".;/ rv

- --------. - _-Jt

~fil r; ~ 13,,7q_:_

\\~f;_~~.D n.._ u £1/1 J.J.

P'f~

]) f\\ T {;;__

,(,..:::_!3_::_2 '!}__

\\

REV NO. DATE t.~

"31...

a.,,11.T r~h!--

~. -.~-..

  • Y CUP>

~OIE=

ALL DIMENSIONS ARE IN FEET UNLESS OTHERWISE NOTED.

2. @) =

13cz.1:1\\.lo~ c.ot.1*1..1.

.. t.Ll CZ.e51lZAl\\.lT5. LIM IT '.>TOPS

'o>l-101.<Jh.I O>-IL'f \\'.Oil TUEeMt.L OERl:CTIOf,J DESIGN DIVISION ENGINEERING STRESS ANAL.

DESCRIPTION COMMENTS OWN CHK VER COMMENTS CALC VER !MT T'l'?\\c.AL t.IOME!--1.C.\\.AiU t2E

~

G5

'2. = fLEME\\..ll NO.

7---0---(: <;Tll.ESS 1-10. POl\\..ff

(,

~:

STecss ~o. ?01~1 C.MbffE~)

+*~

Sul'POZT DI< \\l..f:ST!Zt.l\\..lT Loe. \\..lo.

s rg ~ PIPE (ZU\\..\\ T'E!ZM\\\\..lATI0\\-.1

\\'011-lT

~~

IJ>,b;ffi(ZIAI. a.f.>\\"'Z.G O'WS\\Gr\\..1.1>.ilOhl lt-S<JF-I = ~POOL ?ICCE MARK (FW-SGF- ) : \\:IELOWEL\\) Mb.12\\::'.

0

S~OPWEL\\) MARK

~

'hs.

PIPOYN THERMAL

'~ 51 PIPOYN h>

SEISMIC

~-

REFERENCE DRAWINGS OZ:COTiF'Mr:"TOZTtf ARRGT*,.-----

DIAGRAM __________ _

HGR.LOC._

HGR.OET. ___ _

LG. SP. LOC. _____ _

LG.SP.DET. _________

SM.SP.LOC. ________ _,$._

SM.SP. DET._

INSULATION-'- ___.------

CONST. ISO. ________

E.C.N.' S ----------*

N0.1 UNIT CALC. _______ _

        • SPEC. 1S* l'OA SEISMIC I i.iuCLC:tiZ..[

SALEM NUCLEAR GEN.STA. NO. 1 UNIT li.'.'.Et:.CTOQ CO\\.JTtil\\.Jlv'IEl-.IT e1.oc:;..

STE~M ~'::>l

EEO*.tl~TEIZ fli
OM

.!,i..!C.1\\0~ @.

CO~T61\\JMEIJT "-'.I.LL ~LV ~ 8

.s S\\..,'"** so/e" TO C.Olo.llJ ~ *14 ST~ ~E\\JEU.iO~

267174 S!-1. I o;o 4

Y f11r-;

)

)

I I

.. *.. ~.. _,. ; i >+>: :.

. l S?~/N& #$~.

K=/26<[. '11'1'.

... ( rw.fl-14-.24-J I

u lJ.J 0

' 0 ~

0

.d :;!

0 0 0 l!)

0 I'

~

I-SC,F-17 257174

YfvP)

\\

\\ \\

)_

  • Cf.. _ _[ ::_-*. *- t:*---

I

./

\\

1-sGr~J 5

~'..

. ---/

/

) --

)

I

  • l

.Yf.

_....c-..J-- SGF-171 A?<..-----r--- /?£.ST IPA/NT

//+r'"Wlf'-4 ) -

267174

______.r-_

y(up)

)

~ *

(A}

(D~

(B)..

26.000"0.9. IC..000 O.D. IG.5000.

5.0Zl"W.574-"W.0J'c.7"'.{/

/(;.JlOO<Y I /G?. coo" W. lt~K.

5. 021 I/

. ;:;a 1'"

I ;,..r 9 __;

(c)

(R)

(E)

I /.:5. ?'vo 'I

~~~oo* I I

.574-IJ

~ 7517

/C)

/~&25" I/

~.'250

~G)

I

~

L 3\\5

'\\14.ooo'*

Uf)

(J)

(j()

l)W~J. e c~~.:

'I 2.oG3

. £'2C

.'250'

.1;0

  • ~t'.:~HED.

5?,,!!.:::.

/(?t:J

5?£~.

80

~?EC.

f.' O("(C, Ef)

"'-i1' 00.::: 1::.t-"-> R 100 80 l&'h '\\{ lt1*

l'l,.~\\).

EC c

E~~

1*t~'P 2!. 1 70 0

27~7

'1 II I

//

II

//

I/

//

II II I/

II I

II

//

II 1 "

I I

II

/I II II I/

I I

I I

K

!,';lflfE:~~

MATE.RYAL 1*\\E:r,~~p r~ """ 1,

\\~

11.,.;.*..

~-

~70"' 1 /87o In, 508 CL.iI !V.et,1J.J4 I

II A IOl 9.e C

.5c.AJ1-I.

II II A 134 \\"<} p c II

//

Al O(p GIB. C SEJ\\µ,

ii

//

II I I II

//

//

II A* 105 GtZ.

ii II A. 106 6-~. c.

\\I II

,4 '2 34 WPG

/1 A 2 34 w~c

'Y"HERM~L EXP. COEF~.

  • 0334; /i:'T..,00278 ;;.lN.

ti I/

I/

/I JI I/

II I/

I I

/I II

/I I

..J' SA(P.S:L) 261 2.So

?tJ:? 59

//

I;

-~

II 11 ti I; e 25717~

74*D*43'2.5

SjSTEM I S!C/H'l G-EN-FEEDWATER fiPING-1~.*

S13F-2s~f~L~~~~01*{1t~~~-~~~-=-----=-

... - ~lf!itJ[ SIR~ss6'5___Aj/D Loc.ATU2.N DF Ml\\i,,i MuM 5TRE:s;(Ps1) c- :J

  • -Pf?Ef A-bf:D Bi Jig

~-

Tlre.

.b*~i?..~77 B'f-Wl b(L">j~

DATE:

CHe:e-Ke.p

\\f e:gt F h E-1? Bf bl!_

DAT~e.

Gjl_~/-zi-

'