ML18079A248

From kanterella
Jump to navigation Jump to search
Forwards Rept of Subsurface Water Diversion & Chloride Analysis of Well Water for Quarter Ending 790331
ML18079A248
Person / Time
Site: Salem  
Issue date: 04/16/1979
From: Midura H
Public Service Enterprise Group
To: Webster R
ENVIRONMENTAL PROTECTION AGENCY
References
26-10-12-R1-1-S, NUDOCS 7905080489
Download: ML18079A248 (3)


Text

..

. p e

Public Service Electric and Gas Company P.O. Box 168 Hancocks Bridge, New Jersey 08038 Salem Nuclear Generating Station April 16, 1979 Depa::::tment of Environmental Protection Division of Water Resources Bureau of Water Control P. O. Box 2809 Trenton, New Jersey 08625.

Attention:

Mr. Raymond A. Webster Chief -

Bureau of Water Control SALEM NUCLEAR GENERATING STATION DIVE~SION OF SUBSURFACE WATER AUTHORIZATION A-267 CF... MDEN This letter refers to our Permit No. P-743 for Salem Generating Station covering the diversion of water from wells.

Enclosed are forms, in duplicate f reporting the total ar:1ount of water diverted.

each month and chloride analysis of water from wells No. 1, 2, 3 and 5 for the quarter ending March 31, 1979.

LKM: jcm Enc.

26-10-12-Rl-l-SP Very truly yours, H. J. Midura Manager -

Salem Generating Station

~

17~

Ii'\\STRUCTIONS NEW JEiaY DEPARTMENT OF ENVIRONMENTAL PITECTION W

DIVISION OF WATER RESOURCES BUREAU OF WATER SUPPLY PLA1'\\'NING & MANAGEMENT P.O. Box CN-029, Trenton, New Jersey 08625 PUBLIC POTABLE AND PRIVATE INDUSTRIAL WATER DIVERSION REPORT*

1. Reports must be filed promptly following the close of each quarter. *
2. Report all quantities in units of 1,000 gallons.
3. Use reverse side of this form to report diversion from individual wells, when required, and to report water from and/or to other systems.
4. Obtain the correct name, address and permit number of the permittee from the mailing label of the envelope sent to you.
5. The sums of Items 1 and 2 should equal the sums of Items 3 and 4.

Name of Permittee b

Quarterly Report Permit Number Public Service Electric & Gas Co ** Electric Generation De t.

P-743 Street Address City State Zip P. o. Box 168 Han cocks Bridqe N. J.

08038 For the quarter ending:

For the year:

Summary of Diversion in units of 1,000

~ March 31 D

Sept. 30 1979 D

June 30 D

Dec. 31 1st Month 2nd Month 3rd Month

1. Diversion from own sources Surface 48,322 39,514 34,630 Wells 48,322 39,514 34,630 Total
2. Received from other systems (see 6) l3. Delivered to other systems (see 7)
4. Net diversion for territory served (see 8) 48,322 39,514 34,630
5. How is diversion determined? If estimated, give basis of estimate Meter readinq Well #1 and #5, estimate Well_s * #2 and #3 as percents of Wel 1 :In.*
6. Systems from which water is received
7. Systems to which water is delivered.
8. Municipalities supplied in territory served*
9. Population supplied in territory served
10. Number of service connections in territory served
11. Number of service meters in territory served

~:!i.~1,17?

. ~¥9~~

Date S~e and Official Title The following quotation is from Revised Statutes:

A3: 1-16. Report to commission of amount of water used; examination of meters, records and works. The officers in control of municipal Ta other water works shall keep accurate records by meters or other approved methods, of the amount of water used and shall report the same quarterly to the Commission. The Commission may make such irn-estigation of the meters and records as may be necessary to deter-mine all matters pertinent to its duties, and may examine the plants and works of all public or quasi-public water supplies to ascertain the sources of supply and determine_ the taking and diversion effected, and the charge, if any,_author~zed by law to be made for excess diversion."

  • Tommission" in :1hove quot:1tio11 now means "Division of Water Resources."

Presently we are operating Well Nos. 1, 2, 3 and 5 at.Salem Nuclear Generating Station.

They are metered.

We use no water from an outside source.

The chloride analysis of Nos.

1, 2, 3 and 5.wells are listed below as ppm chloride.

Well #1 January, 1979 65.6 February, 1979 58.7 March, 1979 80.0 26-10-12-Rl-3-SP Well #2 199 212 257 Well #3 46.9 60.5 72.9 L. K. Miller Well #5

. 16.0 16.2 17.9 Station Performance Engineer