ML18078B229

From kanterella
Jump to navigation Jump to search
Forwards LER 79-024/03L-0
Date released: 11/29/2018 Download: ML18078B229


LER 79-024/03L-0 on 790313:air Particulate Monitor Was Declared Inoperable.Caused by Failing Motor Bearings Which Led Filter Paper Drive to Slow & Activate Failed Filter Alarm.Motor Was Cleaned & Bearing Replaced
ML18078B231
Person / Time
Site: Salem 
Issue date: 04/12/1979
From: Kapple A
Public Service Enterprise Group
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
References
Download: ML18078B231 (3)
Forwards LER 79-024/03L-0
ML18078B228
Person / Time
Site: Salem 
Issue date: 04/12/1979
From: Librizzi F
Public Service Enterprise Group
To: GRIER B H
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
References
Download: ML18078B228 (1)