Text

.

PS~G

  • Public Service Electric and Gas Company 80 Park Place Newark, N.J. 07101 Phone 201 /430-7000 February 15, 1979 Director of Nuclear Reactor Regulation U.S. Nuclear Regulatory Commission Washington, DC 20555 Attention:

Mr. Albert Schwencer, Chief Operating Reactors Branch #1 Division of Operating Reactors Gentlemen:

ECCS REANALYSIS FACILITY OPERATING LICENSE DPR-70 UNIT NO. 1 SALEM GENERATING STATION DOCKET NO. 50-272 Public Service Electric and Gas Company hereby submits the results of the reevaluation of ECCS cooling performance cal-culated in accordance with the February 1978 version of the Westinghouse Evaluation Model corrected for the errors iden-tified as related to the Zirc-water reaction heat generation.

This submittal was originally made for Unit No. 2 and is in accordance with your Order for Modification of License dated April 27, 1978.

This submittal includes three signed originals and 40 copies.

7 9 0 2 2 2 Oti9.21~

The Energy People Very truly yours,

~

Frank P. L~;;i General Manager -

Electric Production 95-2001 (400M) 9-77