RO 78-70/01P:on 781021, 13 Reactor Coolant Pump Shaft Seals Failed,Resulting in Excessive Leakage of Primary Coolant Into Container.Detailed RO Rept Will Be Submitted
ML18078A376
Person / Time
Site: Salem PSEG icon.png
Issue date: 10/23/1978
From: Midura H
Public Service Enterprise Group
To:
References
NUDOCS 7811130266
Download: ML18078A376 (1)


Text

    • ----*.

PStiG e-*--

Pubtic Setvke Etectric and Gas Compatay P_Q_ &. 168 Hancocks Bridge. New Jersey 08038 S.tem Nuclear Generating Station October 23, 1978 Mr. Boyce B-Grier Director of USNRC

-,,()f'£ice of Inspections anc! Enforcements Region 1 631. Park Avenue

King of Prussia. Pennsylvania 19406

Dear Mr. Grier:

p REPORTABLE OCCURRENCE 78-70/01~

FAILURE OF NO. 13 REACTOR C00LABT POMP SEALS This letter serves to conf.i:rm our telephone report on Saturday,.

October 21. 1g79, 1347 hours0.0156 days <br />0.374 hours <br />0.00223 weeks <br />5.125335e-4 months <br />, advisinq of a. reportable Occurrence.

in accordance with Technical. Specification 6.9.1.8.c.

Fail.ure of

-the sbaf't sea1s o~ No. 13 Reactor Coo1ant Pump resulted in exces-sive leakage of primary cool.ant int:o icont:a:inment.

The extent of the sha~t seal. ~ailure wi11 be determined during p;mp disassembly.

A detailed report:abl.e occurrence report will be sul:ai:t:ted. in the time period speeif ied by Technical Specifications.

Very truly yours.

B. J. Midura* *-

- Manager - Sal-Generating: Station CC; General Manaqer -