ML18067A774

From kanterella
Jump to navigation Jump to search
Forwards LER 97-011-00 Re Start of Primary Coolant Pump W/Sg Temp Greater than Cold Leg Temp.Commitment Made within Ltr,Listed
Date released: 10/31/2018 Download: ML18067A774


LER 97-011-00:on 971012,primary Coolant Pump Was Started W/Sg Temperatures Greater than Cold Leg Temperature.Caused by Inadequate Procedures & Operator Decision Making.Critique of Event Conducted W/Operators Involved
ML18067A775
Person / Time
Site: Palisades Entergy icon.png
Issue date: 11/11/1997
From: Roberts W
CONSUMERS ENERGY CO. (FORMERLY CONSUMERS POWER CO.)
To:
References
Download: ML18067A775 (4)
Forwards LER 97-011-00 Re Start of Primary Coolant Pump W/Sg Temp Greater than Cold Leg Temp.Commitment Made within Ltr,Listed
ML18067A773
Person / Time
Site: Palisades Entergy icon.png
Issue date: 11/11/1997
From: Thomas J. Palmisano
CONSUMERS ENERGY CO. (FORMERLY CONSUMERS POWER CO.)
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
Download: ML18067A773 (1)