MONTHYEARML18066A6871999-10-19019 October 1999 Forwards Response to NRC 990908 RAI Re Inservice Insp Program Relief Request 14.Ltr Contains No New Commitments & No Revs to Existing Commitments ML18066A6881999-10-19019 October 1999 Forwards Rev 5 to Palisades Nuclear Plant COLR, Per Requirements of TS 6.6.5.Ltr Contains No New Commitments & No Revs to Existing Commitments ML18066A6841999-10-13013 October 1999 Forwards Insp Rept 50-255/99-10 on 990812-0921.One Violation Noted Re Adherence to Radiological Protection Procedure Requirements.Violation Being Treated as Ncv,Consistent with App C of Enforcement Policy ML18066A6781999-10-0707 October 1999 Summarizes 991005 Meeting at Region III to Discuss Radiation Protection Program at Palisades.Topics Discussed Included Management Changes in Radiation Protection Program & Actions Taken to Correct Deficiencies Identified During 1998 Outage ML18066A6651999-10-0505 October 1999 Informs of Completion of Review of Palisades Plant 25-year Tendon Surveillance Rept & Associated post-surveillance Regression Analysis Submitted by Ltrs Dtd 971218,980223 & 980925.Forwards SE Supporting Performance of Surveillance ML18066A6721999-10-0404 October 1999 Forwards Operator Licensing Exam Rept 50-255/99-301(OL) for Initial Operator Licensing Exams at Palisades NPP Completed on 990614.Two RO Applicants & Two SRO Applicants Failed One or More Portions of Respective Exams & Were Denied Licenses ML18066A6741999-10-0202 October 1999 Forwards MOR for Sept 1999 for Palisades Nuclear Plant & Operating Data Rept Sheet for Month of Aug 1999.MOR for Aug 1999 Inadvertently Had Copy of Ref Data Sheet for Apr 1999 Data ML18066A6791999-10-0101 October 1999 Provides Response to RAI Re Draft Rept, Study of Air- Operated Valves in Us Nuclear Power Plants ML18066A6691999-09-30030 September 1999 Advises of Plans for Future Insp Activities at Facility for Opportunity to Prepare for Insps & to Provide Feedback on Any Planned Insps Which May Conflict with Plant Activities ML18066A6621999-09-30030 September 1999 Notifies NRC That Util Will Implement ITS at Plant on or Before Oct 31,2000 & Attachments 1 & 2 Contains Request for License Condition Which Relates First Performance of New or Revised Surveillance Requirements to Implementation of ITS ML18066A6601999-09-29029 September 1999 Forwards NRC Form 536,in Response to NRC Administrative Ltr 99-03, Preparation & Scheduling of Operator Licensing Examinations ML18066A6561999-09-28028 September 1999 Discusses Closeout of GL 97-04, Assurance of Sufficient Net Positive Suction Head for ECC & Containment Heat Removal Pumps. Understands That Util Will Address Concerns Raised by Insp Team at Future Date ML18066A6531999-09-23023 September 1999 Forwards Insp Rept 50-255/99-14 on 990831-0901.No Violations Noted.Insp Results Indicated with Crsd on-line (Non Outage) Planning & Scheduling Program Provided Effective Coordination & Established Appropriate Radiological Control ML18066A6471999-09-17017 September 1999 Forwards Final Clean Copies of ITS & Bases Pages Which Incorporate All Changes Proposed in Listed Ltrs.Clean Copies Also Incorporate Some Editorial Changes & Bases Clarifications as Result of Ongoing Reviews to LCOs ML18066A6441999-09-15015 September 1999 Informs That as Result of 980908 Response to RAI Re GL 92-01,Rev 1,Suppl,staff Revised Info in Rvid & Released Info as Rvid Version 2 ML18066A6431999-09-0808 September 1999 Informs That NRC Tentatively Scheduled Initial Licensing Exam for Operator License Applicants During Wk of 000522,in Response to Nl Haskell ML18066A6381999-09-0808 September 1999 Forwards Request for Addl Info Re ISI Program Relief Request 14 for Palisades Plant ML18066A6391999-09-0303 September 1999 Forwards Insp Rept 50-255/99-09 on 990522-0811.No Violations or Deviations Noted ML18066A6331999-09-0202 September 1999 Forwards Monthly Operating Rept for Aug 1999 & Revised Monthly Operating Rept for Apr 1999 for Palisades Nuclear Plant ML18066A6261999-08-26026 August 1999 Forwards Addl New Valve Relief Request as Alternative to Code Requirements That Will Provide Acceptable Level of Quality & Safety.Request Would Allow Use of App II, Check Valve Condition Monitoring Program, of ASME OM Code-1995 ML18066A6231999-08-26026 August 1999 Forwards SE Related to ISI Program Request for Relief ML18066A6091999-08-19019 August 1999 Provides Licensee with Individual Exam Results for Licensee Applicants Who Took June 1999 Initial License Exam.Without Encls ML20211D5661999-08-17017 August 1999 Forwards semi-annual Fitness for Duty Program Performance Rept for 990101-990630,IAW 10CFR26.71(d).Attachments 1 & 2 Summarize Test Results at Palisades Plant,Big Rock Point Plant & Corporate Ofc ML18066A6111999-08-13013 August 1999 Requests Exemption from Certain Requirements of 10CFR50,App R, Fire Protection Program for Nuclear Power Facilities Operating Prior to 790101. Request Concerns Oil Collection Sys Requirements for PCP Motors ML18066A6031999-08-0909 August 1999 Forwards SE Accepting Licensee Response to GL 96-05, Periodic Verification of Design-Basis Capability of Safety Related Movs, for Plant ML18066A5921999-07-30030 July 1999 Forwards Results of Review by Consumers Energy of Two NRC Draft Repts Entitled, Evaluation of Air-Operated Valves at Light-Water Reactors & Study of Air-Operated Valves in Us Nuclear Power Plants ML18066A5881999-07-30030 July 1999 Provides Rev to Instrument Channel Drift Measurement Submitted on 990611,in Response to NRC Comments on Util RAI Response for Sections 3.3,3.5 & 3.6 & Editorial Changes Revs Necessary for Consistency within ITS ML18066A5971999-07-30030 July 1999 Forwards Markup of Draft NRC SE Re Util Proposal to Convert to Its.Ltr Contains No New Commitments & No Revs to Existing Commitments ML20210G8351999-07-29029 July 1999 Final Response to FOIA Request for Documents.Records in App a Encl & Will Be Available in PDR ML18066A5801999-07-26026 July 1999 Discusses Evaluation of Relief Requests for ISI Re ASME Section Xi,Subsections IWE & Iwl.Staff Partially Denied Relief Request 1 on Basis That General Visual Exam in Lieu of VT-3 Exam.Relief Requests 4 & 6 Denied as Listed ML17191B4031999-07-23023 July 1999 Informs That NRC Plans to Administer GFE Section of Written Operator Licensing Exam on 991006.Ltr Should Be Submitted to Appropriate Regional Administrator at Listed Address to Register Personnel to Take GFE ML18066A5651999-07-19019 July 1999 Forwards Corrections to Previously Submitted TS Section 3.7, Plant Systems, Converting to Its,Per NUREG-1432.Licensee Realized That Certain Provisions of CTS Had Been Inappropriately Replaced with Provisions from STS ML18066A5481999-07-13013 July 1999 Forwards Draft SE Re Proposed Conversion to Its.Se Based on Review of Consumers Energy Co 980126 Application & as Supplemented by 980430,0914,1012,1109,990301,22,30,0407, 0503,0604,11 & 17 Ltrs ML18066A5381999-07-0808 July 1999 Forwards Insp Rept 50-255/99-08 on 990522-0630.No Violations Noted.Determined That Emergent Repairs to EDG Were Completed in Timely & Skillful Manner to Prevent Challenge to Plant Operation ML18066A5361999-07-0606 July 1999 Discusses 990629 Meeting with PRA Staff Re Initiatives in Risk Area & to Be Establish Dialog Between SRAs & PSAs Staff ML18066A5111999-06-29029 June 1999 Provides Voluntary Confirmation of Facility Readiness as Outlined in GL 98-01,Suppl 1, Y2K Readiness of Computer Sys at Npps. Disclosure & Response Encl ML20209B2081999-06-29029 June 1999 Discusses Closure of Response to RAI Re GL 92-01,Rev 1,Suppl 1, Reactor Vessel Structural Integrity. Rvid,Version 2 Issued as Result of Review of Responses.Info Should Be Reviewed & Comments Submitted by 990901 ML20210G8791999-06-23023 June 1999 FOIA Request for All Document Communications Between NRC & Region III Involving R Landsman,B Jorgensen & R Caniano & NRC Staff Under Their Supervision & All Communications in Their Possession to & from Consumers Power Re Plant ML18066A5061999-06-17017 June 1999 Forwards Responses to NRC Questions for ITS LCOs 3.6.3 & 3.6.6 of 990126 Submittal.One Editorial Change in Addition to Those Made in Response to NRC Comments & Conforming Changes Made to Associated Bases,Encl ML18066A4991999-06-11011 June 1999 Forwards Responses to NRC Comments Re ITS Section 3.3 & Associated Revs to ITS Sections 1.0,3.3,3.4 & 3.9 of 990126 ITS Conversion Submittal.One Technical Change & Several Editorial Changes Unrelated to NRC Comments,Also Provided ML18066A4921999-06-0909 June 1999 Discusses Response of 980226 Violation Re Insp Rept 50-255/97-18 Re Failure to Take Adequate Corrective Action. Ltr Contains New Commitments & No Rev ML18068A6011999-06-0808 June 1999 Forwards Description of Recent Changes Made to Palisades Site Emergency Plan,Excluding Minor & Editorial Changes Not Requiring Further Explanation ML18066A4851999-06-0404 June 1999 Forwards Insp Rept 50-255/99-04 on 990410-0521.No Violations Noted.Radiation Dose Received During Outage Was Significantly Less than Projected Because of Radiological Personnel Efforts to Create Heightened Awareness ML18066A4881999-06-0404 June 1999 Provides Responses to NRC Questions & Associated Editorial Revs for ITS LCOs 3.6.1,3.6.2,3.6.4,3.6.5 & 3.6.7 of 980126 Submittal.Responses to Comments on Remaining Section 3.6 LCOs Will Be Submitted Separately ML18066A4811999-06-0303 June 1999 Forwards Insp Rept 50-255/99-06 on 990506-12.Three Violations of NRC Requirements Occurred & Being Treated as non-cited Violations,Consistent with App C of Enforcement Policy ML18066A4731999-05-24024 May 1999 Informs That Region III Received Fema,Region V Ltr Transmitting FEMA Final Exercise Rept for 981201 Plume Exposure Pathway Exercise.No Deficiencies Identified, However,Seven Areas Requiring Corrective Actions Identified ML18066A4801999-05-24024 May 1999 Forwards Copy of Rev to NPDES Permit Number MI0001457 Renewal Application as Submitted to Mi Dept of Environ Quality on 990513 ML18066A4681999-05-19019 May 1999 Forwards Insp Rept 50-255/99-05 on 990503-06.Determined That Violation Occurred & Being Treated as Non-Cited Violation. Insp Focused on Whether Activities Associated with GL 96-05 Were Sufficient to Ensure Continued Capability of MOVs ML18066A4721999-05-18018 May 1999 Informs That During Period from 981101-990430,there Were No NPDES Permit Violations & No Repts of Oil,Salt or Polluting Matl Losses Were Made to Govt Agencies ML18066A4651999-05-17017 May 1999 Forwards ISI Program Relief Request 14 for NRC Approval in Accordance with 10CFR50.55(a)(3) as Requirement for Which Proposed Alternative Provide Acceptable Level of Quality & Safety.Rev 0 to SIR-99-032 Rept Also Encl 1999-09-08
[Table view] Category:INCOMING CORRESPONDENCE
MONTHYEARML18066A6881999-10-19019 October 1999 Forwards Rev 5 to Palisades Nuclear Plant COLR, Per Requirements of TS 6.6.5.Ltr Contains No New Commitments & No Revs to Existing Commitments ML18066A6871999-10-19019 October 1999 Forwards Response to NRC 990908 RAI Re Inservice Insp Program Relief Request 14.Ltr Contains No New Commitments & No Revs to Existing Commitments ML18066A6741999-10-0202 October 1999 Forwards MOR for Sept 1999 for Palisades Nuclear Plant & Operating Data Rept Sheet for Month of Aug 1999.MOR for Aug 1999 Inadvertently Had Copy of Ref Data Sheet for Apr 1999 Data ML18066A6791999-10-0101 October 1999 Provides Response to RAI Re Draft Rept, Study of Air- Operated Valves in Us Nuclear Power Plants ML18066A6621999-09-30030 September 1999 Notifies NRC That Util Will Implement ITS at Plant on or Before Oct 31,2000 & Attachments 1 & 2 Contains Request for License Condition Which Relates First Performance of New or Revised Surveillance Requirements to Implementation of ITS ML18066A6601999-09-29029 September 1999 Forwards NRC Form 536,in Response to NRC Administrative Ltr 99-03, Preparation & Scheduling of Operator Licensing Examinations ML18066A6471999-09-17017 September 1999 Forwards Final Clean Copies of ITS & Bases Pages Which Incorporate All Changes Proposed in Listed Ltrs.Clean Copies Also Incorporate Some Editorial Changes & Bases Clarifications as Result of Ongoing Reviews to LCOs ML18066A6331999-09-0202 September 1999 Forwards Monthly Operating Rept for Aug 1999 & Revised Monthly Operating Rept for Apr 1999 for Palisades Nuclear Plant ML18066A6261999-08-26026 August 1999 Forwards Addl New Valve Relief Request as Alternative to Code Requirements That Will Provide Acceptable Level of Quality & Safety.Request Would Allow Use of App II, Check Valve Condition Monitoring Program, of ASME OM Code-1995 ML20211D5661999-08-17017 August 1999 Forwards semi-annual Fitness for Duty Program Performance Rept for 990101-990630,IAW 10CFR26.71(d).Attachments 1 & 2 Summarize Test Results at Palisades Plant,Big Rock Point Plant & Corporate Ofc ML18066A6111999-08-13013 August 1999 Requests Exemption from Certain Requirements of 10CFR50,App R, Fire Protection Program for Nuclear Power Facilities Operating Prior to 790101. Request Concerns Oil Collection Sys Requirements for PCP Motors ML18066A5971999-07-30030 July 1999 Forwards Markup of Draft NRC SE Re Util Proposal to Convert to Its.Ltr Contains No New Commitments & No Revs to Existing Commitments ML18066A5881999-07-30030 July 1999 Provides Rev to Instrument Channel Drift Measurement Submitted on 990611,in Response to NRC Comments on Util RAI Response for Sections 3.3,3.5 & 3.6 & Editorial Changes Revs Necessary for Consistency within ITS ML18066A5921999-07-30030 July 1999 Forwards Results of Review by Consumers Energy of Two NRC Draft Repts Entitled, Evaluation of Air-Operated Valves at Light-Water Reactors & Study of Air-Operated Valves in Us Nuclear Power Plants ML18066A5651999-07-19019 July 1999 Forwards Corrections to Previously Submitted TS Section 3.7, Plant Systems, Converting to Its,Per NUREG-1432.Licensee Realized That Certain Provisions of CTS Had Been Inappropriately Replaced with Provisions from STS ML18066A5111999-06-29029 June 1999 Provides Voluntary Confirmation of Facility Readiness as Outlined in GL 98-01,Suppl 1, Y2K Readiness of Computer Sys at Npps. Disclosure & Response Encl ML20210G8791999-06-23023 June 1999 FOIA Request for All Document Communications Between NRC & Region III Involving R Landsman,B Jorgensen & R Caniano & NRC Staff Under Their Supervision & All Communications in Their Possession to & from Consumers Power Re Plant ML18066A5061999-06-17017 June 1999 Forwards Responses to NRC Questions for ITS LCOs 3.6.3 & 3.6.6 of 990126 Submittal.One Editorial Change in Addition to Those Made in Response to NRC Comments & Conforming Changes Made to Associated Bases,Encl ML18066A4991999-06-11011 June 1999 Forwards Responses to NRC Comments Re ITS Section 3.3 & Associated Revs to ITS Sections 1.0,3.3,3.4 & 3.9 of 990126 ITS Conversion Submittal.One Technical Change & Several Editorial Changes Unrelated to NRC Comments,Also Provided ML18066A4921999-06-0909 June 1999 Discusses Response of 980226 Violation Re Insp Rept 50-255/97-18 Re Failure to Take Adequate Corrective Action. Ltr Contains New Commitments & No Rev ML18068A6011999-06-0808 June 1999 Forwards Description of Recent Changes Made to Palisades Site Emergency Plan,Excluding Minor & Editorial Changes Not Requiring Further Explanation ML18066A4881999-06-0404 June 1999 Provides Responses to NRC Questions & Associated Editorial Revs for ITS LCOs 3.6.1,3.6.2,3.6.4,3.6.5 & 3.6.7 of 980126 Submittal.Responses to Comments on Remaining Section 3.6 LCOs Will Be Submitted Separately ML18066A4801999-05-24024 May 1999 Forwards Copy of Rev to NPDES Permit Number MI0001457 Renewal Application as Submitted to Mi Dept of Environ Quality on 990513 ML18066A4721999-05-18018 May 1999 Informs That During Period from 981101-990430,there Were No NPDES Permit Violations & No Repts of Oil,Salt or Polluting Matl Losses Were Made to Govt Agencies ML18066A4651999-05-17017 May 1999 Forwards ISI Program Relief Request 14 for NRC Approval in Accordance with 10CFR50.55(a)(3) as Requirement for Which Proposed Alternative Provide Acceptable Level of Quality & Safety.Rev 0 to SIR-99-032 Rept Also Encl ML18066A4611999-05-14014 May 1999 Requests Approval to Use Alternative Requirements IAW 10CFR50.55a(a)(3)(i),proposing to Follow Requirements of ASME Boiler & Pressure Vessel Code Case N-566-1.IST Program Relief Request 6 for NRC Approval Encl ML18068A5831999-05-0303 May 1999 Forwards Proposed TS Section 3.5,in Response to NRC 990317 RAI Re Util 980126 TS Change Request Re Conversion to Improved Ts,Per NUREG-1432 ML20206J2411999-04-30030 April 1999 Submits Corrected Copy of Ltr Forwarding 1998 Consumers Energy Co Annual Rept. Ltr Contains Corrected Docket & License Number for Big Rock Point.With One Oversize Encl ML20217A8191999-04-29029 April 1999 Forwards Listed Matls Related to Palisades Plant June 1999 Initial License Exam ML20206E8271999-04-28028 April 1999 Forwards Palisades Plant Annual Radiological Environ Operating Rept for 1998. There Were No Reportable Events During This Period ML20207B4661999-04-23023 April 1999 Forwards Copy of Final Exercise Rept for Biennial Radiological Emergency Preparedness Exercise Conducted on 981201 for Palisades Npp.No Deficiencies Noted.Seven New Arcas Identified ML18066A4531999-04-0707 April 1999 Forwards ITS Pages 3.1.4-2 & 3.1.4-8,revising Completion Time for Action D.1,as Requested by NRC 990406 Telcon,Per TS Change Request Submitted 980126.Change Submitted Does Not Alter Conclusions of No Signficant Hazards Considerations ML18066A4481999-04-0202 April 1999 Responds to Violations Noted in Insp Rept 50-255/98-06. Corrective Actions:Nuclear Performance Assessment Dept Has Reviewed Observations & Agrees That Field Observations by Qualified Personnel Are Important Aspect of Program ML18066A4471999-03-30030 March 1999 Confirms Completion of Util Review of Design Engineering Contractor Cable Ampacity Evaluation.Evaluation Available at Plant for NRC Review ML18066A4411999-03-30030 March 1999 Forwards Response to NRC 990126 RAI Re TS Section 3.7 of Util 980126 LAR Request for Conversion to Its.Licensee Received Permission to Delay TS Section 3.6 Response to Allow for Addl Time for Preparation & Internal Review ML18066A4441999-03-26026 March 1999 Submits Certification of Financial Assurance for Decommissioning of Palisades Nuclear Plant.Certified Rept of Status of Consumers Energy Co Decommissioning Funding & Trust Agreement Encl as Attachments 1 & 2 ML18066A4401999-03-25025 March 1999 Forwards Revised Best Estimate Fluence Evaluation Using Industry Data, Providing Justification for Using Industry Data to Determine Best Estimate Fluence.Review of Info & SE Requested ML18066A4191999-03-23023 March 1999 Forwards 1998 Annual Radioactive Effluent Release & Disposal Rept, for Palisades Plant,Providing Summary of Quantities of Radioactive Liquid & Gaseous Effluent Releases & Solid Radioactive Waste Processed During 1998 ML18066A4231999-03-22022 March 1999 Forwards Answers to 990311 Telcon Request for Addl Clarification & Revs Re ITS Section 3.4.Markups of Previously Submitted TS Pages & Revised Pages for Section 3.4 Also Encl ML20204F2091999-03-18018 March 1999 Requests That Listed TS Change Requests (Tscrs) Be Issued with Allowance That Tscrs Be Fully Implemented within Sixty Days of Issuance.Request Will Allow Time for Completion of Final Training & Procedure Changes Associated with Amend ML18066A4141999-03-18018 March 1999 Forwards Rev 4 to COLR, Containing Limits for Fuel Cycle 14 & Future Cycles ML18066A4121999-03-18018 March 1999 Concludes That Mod to Provide Automatic Switchover of Control Room Heating,Ventilation & Air Conditioning (CRHVAC) Sys to Emergency Mode Is Not Needed to Meet Regulatory Requirements.Mod Commitment Cancelled ML20204E5861999-03-16016 March 1999 Submits Current Limits of Property Insurance Maintained at Consumers Energy Co Operating Nuclear Power Plants ML18066A4131999-03-11011 March 1999 Responds to NRC Re Violations Noted in Insp Rept 50-255/98-22.Corrective Actions:Analytical Evaluation, EA-C-PAL-98-1067-01, P-50A Case to Cover Stud Evaluation, Was Submitted to NRC on 981220 ML18068A5241999-02-12012 February 1999 Resubmits Relief Request 12,with Addl Info That Includes Specific Locations Where Relief Request Would Be Applied,Per 10CFR50.55a(g)(5)(iii) ML18068A5211999-02-11011 February 1999 Informs NRC That Implementation of Formal Industry Position on Severe Accident Mgt at Palisades Plant Was Completed on 981217 ML18066A4051999-02-10010 February 1999 Requests Copy of Consumers Energy (Palisades) Formal Response to RAI (USI A-46) ML18066A3921999-01-29029 January 1999 Forwards Licensee Interpretation of TS Requirements for Performance of SRs as Applied to Instrumentation Channel Calibr.Ltr Established No New Commitments ML18066A3891999-01-28028 January 1999 Submits Response to Concern Expressed in Insp Rept 50-255/98-06 Re Whether Palisades ISI Program Was Being Conducted IAW Applicable Requirements ML18066A3721999-01-14014 January 1999 Forwards Rev 1 to EA-C-PAL-98-1939-01, Evaluation of Corrosion on Studs Between Casing & Cover of Pump P-50A, Reference C-PAL-98-1939, in Support of Urgent Request for Relief from Provisions of ASME Section Xi,Article IWA-5250 1999-09-30
[Table view] |
Text
t
~
1_
f-
/.
A CMS Energy eompany Palisades Nuclear Plant Tel: 616 764 2276 27780 Blue Star Memorial Highway Fax: 616 764 2490 September 25, 1998 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555 Covert, Ml 49043 DOCKET 50-255 - LICENSE DPR PALISADES PLANT Nathan L. HBBkflll Director, Licensing RESPONSE TO REQUEST FOR ADDITIONAL INFORMATION REGARDING PALISADES 25-YEAR CONTAINMENT INTEGRITY SURVEILLANCE REPORT Consumers Energy submitted the Palisades' 25-Year Containment Integrity Report and the associated post surveillance regression analysis on December 18, 1997, and February 23, 1998. These submittals were made to meet the requirements of Technical Specification 6.6.8. On July 27, 1998, the NRC issued a request for additional information (RAI) related to this report. The attachment to this letter provides that information.
SUMMARY
OF COMMITMENTS This letter contains no new commitments and no revisions to existing commitments.
~l\\lQ.J-~
Nathan L. Haskell Director, Licensing CC Administrator, Region Ill, USNRC Project Manager, NRR, USNRC NRC Resident Inspector*- Palisades Attachment
ATTACHMENT CONSUMERS ENERGY COMPANY PALISADES PLANT DOCKET 50-255 RESPONSE TO REQUEST FOR ADDITIONAL INFORMATION REGARDING PALISADES 25-YEAR CONTAINMENT INTEGRITY SURVEILLANCE REPORT 2 Pages
RESPONSE TO REQUEST FOR ADDITIONAL INFORMATION REGARDING PALISADES 25-YEAR CONTAINMENT INTEGRITY SURVEILLANCE REPORT NRC REQUESTED INFORMATION
- 1.
Table VIII, Attachment I (February 23, 1998 submittal): The predicted forces shown for sampled vertical, hoop and dome tendons indicate that the elastic shortening losses in all the tendons for each group (vertical, hoop and dome) are the same.
This is possible only if all the tendons in that group were tensioned at the same time. For the comparison of individual tendon lift-off forces with the respective predicted forces, this distinction is important. Provide justification for using the same value of predicted forces. Also, provide information about how the time-dependent prestrf;Jssing force losses (due to creep and shrinkage of concrete, and relaxation of prestressing steel) are incorporated in the predicted forces.
CONSUMERS ENERGY RESPONSE
- 1.
Review of prestressing records indicates each of the selected tendons was stressed during the period of time between May 16 and September 22, 1969. Based on the short period of time between the first and last tendon stressing date versus the 25 years of service, it was not necessary to individually calculate predicted stress levels for each tendon. The only exception is tendon V-126 which was removed and reinstalled during the Palisades Steam Generator Replacement Project in 1991.
Tendon V-126 is discussed in our response to Question 2. To minimize the impact of subsequent tensioning of other tendons on the already tensioned tendons, normalization of jacking forces was performed. This normalization resulted in equal prestress loss for all tendons in each group (vertical, hoop and dome).
The effects of elastic shortening, creep and shrinkage of concrete and relaxation of prestressing steel are described in FSAR, Section 5.8.5.3. In accordance with ACI 318-63, elastic shortening, creep, shrinkage and tendon relaxation were considered in the design of the prestressing tendons. The required tendon prestressing forces for all the tendons were calculated to account for all the postulated losses.
1
~
RESPONSE TO REQUEST FOR ADDITIONAL INFORMATION REGARDING PALISADES 25-YEAR CONTAINMENT INTEGRITY SURVEILLANCE REPORT NRC REQUESTED INFORMATION
- 2.
Table VIII, Attachment I: The stresses in the wires of Tendon V-126 are above 70 percent of the guaranteed ultimate tensile strength of the wires at the 25-year surveillance. Factors such as improper lift-off, improper jack calibration, or high initial installation force could be responsible for such measured data. Provide an explanation for such high stresses in the tendon wires, including any history of prior measurements and initial installation data. It appears that the negative regression analysis line for the vertical tendons (Figure 5 of the February 23, 1998, submittal) is due to the high lift-off force of this tendon. Please verify the reliability of the lift-off reading, and explain the anomalous behavior of the vertical tendons.
CONSUMERS ENERGY RESPONSE
- 2.
Per FSAR 5.8.9.2, during the 1990 steam generator replacement project, vertical tendons from approximately azimuth 49° to azimuth 189° were detensioned prior to removing the existing concrete from the temporary construction opening. Those tendons intersecting the construction opening were detensioned and removed. The retensioning forces were established to account for the projected tendon losses over the remaining plant life.
In accordance with FSAR Figure 5.8-30, vertical tendon.V-126 was removed during the steam generator replacement project in 1990. Following replacement of the tendon, the required minimum lock-off force was 725 Kips. The Prestress Report for Steam Generator Replacement, Palisades Nuclear Plant, dated February 1991, Table 4-5 indicates V-126 lock-off force was 748.96 Kips. Based on this information, the 25-Year surveillance results indicated a 4 ksi loss in prestress for this tendon. The effect of this higher than expected lift-off value is a regression curve with positive slope.
A similar situation occurred with the 20-year surveillance results which included tendon V-128, also removed during the Steam Generator Replacement. The lift-off force of 680 Kips was greater than the predicted force by 7.01 %. This tendon force skewed the average results for the 20-Year surveillance,' also. Since the test scope for the 5th and 10th year surveillances selected tendons with lower lift-off averages, a regression curve with a positive slope is expected.
2