a1FW-ff.EA'£4./l/PCZ.£4.R COA'/?

April 17, 1998 Mr. Timothy Kobetz M/S06-G-22 U.S. Nuclear Regulatory Commission 11555 Rockville Pike Rockville, MD 20852 7;2... f007 SNC 98-011

Subject:

Transmittal of Calculation Package CPC-06Q-301Revision2; Attachment to response to Question 4 of Request for Additional Information concerning Corrective Action Letter 97-7-001

Reference:

Corrective Action Letter(CAL) 97'."'7-001 issued May 16, 1997

Request for Additional Information concerning CAL 97-7-001 (TAC No.
L21140) issued August 26, 1997

Dear Mr. Kobetz,

As an update to the response to Question 4 of the Request for Additional Information concern-ing CAL 97-7-001, Sierra Nuclear Corporation(SNC) submits the attached Revision 2 of calculation package CPC-06Q-301, titled: Allowable Flaw Size Definition for VSC-24 Dry Storage Cask Structural Lid to Shell Weld.

The calculation has been* revised and now includes structural analysis based on Charpy impact and fracture toughness material test results obtained from coupons welded by Arkansas Nuclear One, Palisades and Point Beach

  • Nuclear Plant. The coupon material was welded using plant specific weld materials and procedures..

Shocld you h3ve any questions* or comments regarding this transmittal, please* feel free to contact me at Sierra Nuclear Corporation; 408-438-6444.

Respectfully, l-.'"'anager, Licensing

~~~42~g5g~ 6~8~a~55 V

PDR cc:

G.Dixon; lie file; f:\\admin\\ltr\\snc\\98001 J.Broschak, CE; M.Holzmann, WEPCo; R.Kellar, Entergy; 1 Victor Square*

  • Scotts Valley, California 95066 (408) 438-6444 Fax (408) 438-5206