f.

Mr. Thomas C. Berdine Manager, Licensing Palisades Plant 27780 Blue Star Memorial Highway Covert, MI 49043 December 5, 1997

SUBJECT:

PALISADES PLANT-REQUEST FOR ADDITIONAL INFORMATION RELATED TO CONSUMERS ENERGY COMPANY'S PRIMARY COOLANT PUMP FLYWHEEL INSPECTION TECHNICAL SPECIFICATION CHANGE REQUEST (TAC NO. M94567)

Dear Mr. Berdine:

The staff requires additional information in order to complete our review of your primary coolant pump flywheel inspection technical specification change request submitted January 18, 1996, and supplemented on October 1, 1997. The enclosed questions were discussed with members of your staff by telephone on November 18, 1997. Please provide a response to the enclosed questions within 30 days of the date of this letter. If you have any questions regarding this request, please contact me at 415-1312.

Docket No. 50-255 Sincerely, ORIGINAL SIGNED BY Robert G. Schaaf, Project Manager Project Directorate 111-1 Division of Reactor Projects - 111/IV Office of Nuclear Reactor Regulation

Enclosure:

Request for Additional Information cc w/encl: See next page DISTRIBUTION: See attached list

\\

DOCUMENT NAME: G:\\WPDOCS\\PALISADE\\WP61\\PAL94567.RAI To receive a copy of this document, indicate in the box C=Copy w/o attachment/enclosure E=Copy with attachme.nt/enclosure N = No copy OFFICE PM:PD31 E

LA:PD31 NAME RSchaaf CJamerson

' /

---~~

12/ ')" /97 9712150342 971205 I llllll lllll lllll lllll llllll llll llll llll

  • 12/ '-/ /97

',OFFICIAL RECORD COPY PDR ADOCK 05000255 P

PDR I

i 2

3 c

4 0

Mr. Thomas C. Berdine Consumers Energy Company cc:

Mr. Thomas J. Palmisano Site Vice President Palisades Plant 27780 Blue Star Memorial Highway Covert, Michigan 49043 Mr. Robert A. Fenech, Sr Vice Pres Nuclear, Fossil, and Hydro Operations Consumers Energy Company 212 West Michigan Avenue Jackson, Michigan 49201 M. I. Miller, Esquire Sidley & Austin 54th Floor One First National Plaza Chicago, Illinois 60603 Mr. Thomas A. McNish Vice President & Secretary Consumers Energy Company 212 West Michigan Avenue Jackson, Michigan 49201 Judd L. Bacon, Esquire Consumers Energy Company 212 West Michigan Avenue Jackson, Michigan 49201 Regional Administrator, Region Ill U.S. Nuclear Regulatory Commission 801 Warrenville Road Lisle, Illinois 60532-4351 Jerry Sarno Township Supervisor Covert Township 36197 M-140 Highway Covert, Michigan 49043 Office of the Governor Room 1 - Capitol Building Lansing, Michigan 48913 Palisades Plant U.S. Nuclear Regulatory Commission Resident Inspector's Office Palisades Plant 27782 Blue Star Memorial Highway Covert, Michigan 49043 Drinking Water and Radiological Protection Division Michigan Department of Environmental Quality 3423 N. Martin Luther King Jr Blvd P. 0. Box 30630 CPH Mailroom Lansing, Michigan 48909-8130 Gerald Charnoff, Esquire Shaw, Pittman, Potts and Trowbridge 2300 N Street, N. W.

Washington DC 20037 Michigan Department of Attorney General Special Litigation Division 630 Law Building P.O. Box 30212 Lansing, Michigan 48909 July 1997

REQUEST FOR ADDITIONAL INFORMATION RELATED TO CONSUMERS ENERGY COMPANY'S PRIMARY COOLANT PUMP FLYWHEEL INSPECTION TECHNICAL SPECIFICATION CHANGE REQUEST This request for additional information refers to Consumers Energy Company's technical specification change request submittals dated January 18, 1996, and October 1, 1997.

The application of topical report SIR-94-080-A, "Relaxation of Reactor Coolant Pump Flywheel Inspection Requirements," to Palisades requires that the licensee (1) verify the reference temperature, RT NOT* for the flywheel material (ASTM A-108 (1017) low carbon steel), and (2) justify the use of the K,0 vs. (T-RTNoT) curve in Appendix A of Section XI of the ASME Code.

It does not appear as if these requirements have been adequately addressed in the licensee's submittals. Please provide:

(1)

Plant-specific test data or data from other sources to demonstrate that the NOT is 40 °F and the RTNoT is also 40 °F.

(2)

Plant-specific test data or data from other* sources to demonstrate that the K,0 vs.

(T-RTNoT) curve for ASTM A-108 (1017) low carbon steel is similar to the K,0 vs.

(T-RT NoT) curve in Appendix A of Section XI of the ASME Code derived from test data for SA 5338 and SA 508 materials. The cited 100 ksi-in1'2 was estimated from the ASME curve; however, the applicability of the ASME curve to the Palisades flywheel material has not been established.

Enclosure