ML18065A872

From kanterella
Jump to navigation Jump to search
Forwards LER 96-010 Re Trip of High Pressure Safety Injection Pump While Filling Safety Injection Tank. New Commitments Contained in LER Listed
ML18065A872
Person / Time
Site: Palisades Entergy icon.png
Issue date: 08/16/1996
From: Bordine T
CONSUMERS ENERGY CO. (FORMERLY CONSUMERS POWER CO.)
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
Shared Package
ML18065A873 List:
References
NUDOCS 9608230141
Download: ML18065A872 (2)


Text

consumers Power l'OWERIN&

MICHl&AN"S PRO&RESS Palisades Nuclear Plant: 27780 Blue Star Memorial Highway, Covert, Ml 49043 August16, 1996 U.S. Nuclear Regulatory Commission Document Control Desk Washington, DC 20555 DOCKET 50-255 - LICENSE DPR PALISADES PLANT LICENSEE EVENT REPORT 96-010 -TRIP OF HIGH PRESSURE SAFETY INJECTION PUMP WHILE FILLING SAFETY INJECTION TANK Licensee Event Report 96-01 O.is attached. This condition is reportable to the NRC in accordance with 10 CFR 50.73(a)(2)(i)(B) as a condition prohibited by the plant's Technical Specifications.

SUMMARY

OF COMMITMENTS This letter contains two new commitments and no revisions to existing commitments.

The two new commitments are:

1. Review the stock balance of spare motor protection relays for all safety-related motors. Procure necessary spare relays as considered appropriate by System Engineering. ~

s**J0Q025 9608230141 960816 PDR ADOC.K 05000255 S PDR A CMS' ENERGY COMPANY

2

2. Revise Standard Operating Procedure (SOP) 3 to permit the use of High Pressure Safety Injection (HPSI) Pump P-668 to fill Safety Injection Tanks at full Primary Coolant System pressure, if justified by engineering analysis.

Thomas C. Berdine Manager, Licensing CC Administrator, Region Ill, USNRC Project Manager, NRR, USNRC NRC Resident Inspector - Palisades Attachment