Text
.,
consumers Power*
l'OWERINli MICHlliAN'S l'ROliRESS Palisades Nuclear Plant: 27780 Blue Star Memorial Highway, Covert, Ml 49043 c-february 5, 1996 US Nuclear Regulatory Commission Document Control Desk Washington, DC 20555 DOCKET 50-255 - LICENSE DPR PALISADES PLANT WITHDRAWAL OF REQUEST FOR RELIEF FROM APPENDIX J PRESSURE TESTING ON THE ESCAPE AIR LOCK.
Consumers Power Company hereby withdraws* our letter dated February 10, 1995 entitled "Request for Relief From Appendix J Pressure Testing on the Escape Air Lock".
The Request for Relief was determined to be the incorrect format to resolve this issue. A Request for Exemption - 1 OCFR50, Appendix J, Pressure Testing on the Emergency Escape Airlock Doors and a Technical Specifications Change Request - Local Leak Rate Testing of the Emergency Escape Airlock was submitted on January 10, 1996. The January 10, 1996 submittal supersedes the previous request.
SUMMARY
OF COMMITMENTS This letter contains no new commitments and no revisions to existing commitments.
9602120391 960205 PDR ADOCK 05000255 P
~*
c:>~
Richard W Smedley Manager, Licensing cc Administrator, Region Ill, USNRC Project Manager, NRR, USNRC NRG Resident Inspector - Palisades
- ' *:) ""\\
.Ji.0U019 A GI/IS ENERGY COMPANY