ML18065A361

From kanterella
Jump to navigation Jump to search
Provides Correction of Typographical Errors Re 951117 Response to GL 92-01,rev 1,suppl 1, Reactor Vessel Structural Integrity
ML18065A361
Person / Time
Site: Palisades 
Issue date: 12/20/1995
From: Smedley R
CONSUMERS ENERGY CO. (FORMERLY CONSUMERS POWER CO.)
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
GL-92-01, GL-92-1, NUDOCS 9512260291
Download: ML18065A361 (4)


Text

~......

consumers Power POW ERi Nii MICHlliAN'S PROGRESS Palisades Nuclear Plant: 27780 Blue Star Memorial Highway, Covert, Ml 49043 December 20, 1995 U S Nuclear Regulatory Commission Document Control Desk Washington, DC 20555 DOCKET 50-255 - LICENSE DPR PALISADES PLANT RESPONSE TO NRC GENERIC LETTER 92-01, REVISION 1, SUPPLEMENT 1:

REACTOR VESSEL STRUCTURAL INTEGRITY - CORRECTION OF TYPOGRAPHICAL ERRORS Consumers Power Company submitted our six-month response to Generic Letter 92-01, Revision 1, Supplement 1 on November 17, 1995. However, Attachments 2 and 3 each contained a typographical error. The errors were in the intermediate calculations for weight percent copper and because c;>f their typographical nature, they did not affect the final best estimate values for weight percent copper.

Enclosed are corrected Attachments 2 and 3.

SUMMARY

OF COMMITMENTS This letter contains no new commitments and no revisions to existing commitments.

Richard W Smedley Manager, Licensing CC Administrator, Region Ill, USNRC Project Manager, NRR, USNRC NRC Resident Inspector - Palisades Attachment 960072 r-

0 ~-,...~~~.....,,..,....,Mrr.-:-.:;,J '

. 9512260291 951220 l I,

l PDR ADOCK 05000255 i I

... ~....f-.~-**~--~~-.....

PDR A CMS'ENER6YCOMPANY

ATTACHMENT 1 CONSUMERS POWER COMPANY PALISADES PLANT DOCKET 50-255 CORRECTED ATTACHMENTS 2 AND 3 2 Pages

Weight Percent Copper in Heat 348009 Welds Sample Description Cu%

Weight (Cu %) x Weight ML 1 surv.

0.184 1

0.184 PAL SG, region 3 0.185 2

0.37 HBR2 torus-dome 0.187 1

0.187 PAL SG, region 2 0.190 2

0.38 PAL SG, region 1

  • 0.190 2

0.38 Sum 8

1.501 Mean Value 0.188 Weight Percent Nickel in Heat 348009 Welds Sample Description Average Ni%

ML 1 surv. weld 1.05 HBR2 torus-dome weld 0.80 Palisades SG 1.09 Mean Value 0.98

Weight Percent Copper in Heat 27204 Welds Sample Description Cu%

Weight (Cu%) x Weight Mihama 6-1 52 0.180 1

0.180 FC 1-41 OB 0.194 8

1.552 05805 & 05927 0.195

  • 1 0.195 OC1 surv. weld 0.198 1

0.198 Salem 6-0468

. 0.223 1

0.223.

PAL 1-982.

0.230 1

0.230 Sum 13 2.578 Mean Value 0.198 Weight Percent Nickel in Heat 27204 Welds Sample Description Average Ni %

Mihama 6-1 52

  • 0.96 OC1 surv. weld 1.00.

05805 & 05927 1.01 PAL 1-982 1.05 FC 1-4108 1.07 Mean Value 1.02