consumers Power POW ERi Nii MICHlliAN"S PROliRESS Palisades Nuclear Plant: 27780 Blue Star Memorial Highway, Covert, Ml 49043 November 17, 1995 Nuclear Regulatory Commission Document Control Desk Washington, DC 20555 DOCKET 50-255 - LICENSE DPR PALISADES PLANT RESPONSE TO NRC GENERIC LETTER 92-01, REVISION 1, SUPPLEMENT 1:

REACTOR VESSEL STRUCTURAL INTEGRITY Generic Letter 92-01, Revision 1, Supplement 1 requested additional information concerning weld chemistry and its impact on the structural integrity of the Palisades reactor vessel. This request was divided into four parts. The response to part ( 1) was requested within 90 days and the response to parts (2), (3), and (4) was requested within six months. This letter provides the six-month response to Generic Letter 92-01, Revision 1, Supplement 1 for the Palisades reactor vessel.

Consumers Power Company submitted the available information on the Palisades reactor vessel beltline materials in our response to Generic Letter 92-01, Revision 1 dated July 3, 1992 and in our Pressurized Thermal Shock submittals of December 28, 1994 and January 16, 1995. Our 90-day response to Generic Letter 92-01, Revision 1, Supplement 1 was dated August 17, 1995 and contained our response to part (1 ). The following is the CPCo response to parts (2), (3), and (4).

(2)

An assessment o( any change in best-estimate chemistry based on consideration of all relevant data CPCo performed a review of all relevant data and reassessed our best estimate chemistry based on new data available to us. CPCo communicated and shared available data with other utilities that have reactor vessel welds fabricated from the same weld wire heat numbers as the Palisades reactor vessel beltline welds. CPCo 9511270010 951117 1

  • PDR ADOCK 05000255
  • P

. PQR...

A CMS' ENERGY COMPANY no,,".

tt '\\'

2 will continue to assume that all Palisades reactor vessel beltline axial welds are represented by the best estimate values of welds fabricated with weld wire heat number W5214.

  • CPCo believes weld wire heat number W5214. provides the most conservative values for RT Nor for welds because the.copper and nickel concentrations are higher than those fabricated with*: weld wire heat 348009.

The information on welds fabricated using weld wire heat number W5214 was shared with the utilities known to have welds fabricated with this weld wire. The only chemistry not included in the Palisades submittal of December 28, 1994. is that obtained from the microprobe measurements performed on the Palisades steam generator welds, which were performed to aid in the selection of material for the supplemental surveillance capsules installed during the 1995 refueling outage.

These copper and nickel measurements and the measurements reported in Table 1 of the NRC April 12, 1995 Safety Evaluation Report' (SER) are detailed in '

  • . Including that additional chemistry data and using the same weighting procedure as used in the SER results in slightly lower copper and nickel concentrations for the Palisades steam generator welds. Attachment 1. shows the effect of this additional information on the best estimate values. for reactor vessel welds fabricated with weld wire heat W5214 detailed in Tables 4 and 5 of the SER..

Information on welds fabricated using weld wire heat n'umber 348009 was shared with the utilities known to have welds fabricated with this weld wire. The only chemistry not included in the Palisades submittal of December 28, 1994 is that obtained from the microprobe measurements on the Palisades steam generator welds, which were performed to aid in the selection of material for the supplemental surveillance capsules installed during the 1995 refueling outage.

These copper and nickel measurements and the measurements supplied in Table 2 of the SER are detailed in Attachment 5. Using the same weighting procedure as used in the SER results in best estimate values for reactor vessel welds fabricated with 348009 shown in Attachment 2.

Information on welds fabricated with weld wire heat 27204 was reviewed to determine if any changes in the best estimate chemistry were warranted.

Additional information was available on the surveillance weld in Capsule Y of the Diablo Canyon 1 surveillance program (WCAP-13570) and on a Fort Calhoun nozzle cutout included in a CEOG weld chemical variability study (CE NPSD-944-P). A~8 has performed a review of the fabrication details of the weld wire heat 27204 welds for CPCo.. U_sing the same weighting process as used in the SER results in copper and nickel concentrations shown in Attachment 3.

(3)

A determination of the need for use of the ratio procedure in accordance with the established Position 2. 1 of Regulatory Guide 1. 99, Revision 2, for those licensees that use surveillance data to provide a basis for the RPV integrity evaluation 3

CPCo intends to use the ratio procedure when evaluating the results of the supplemental surveillance capsules installed during the 1995 refueling outage. As described in our October 12, 1995 submittal, "Preliminary Thermal Annealing Report Section 3", weld material was selected that is expected to* exhibit material property test results that after being exposed to operating and annealing conditions will produce physical test results that will bound the predicted physical properties of the weld material in the post-annealed reactor vessel. Test results from these materials will be adjusted in accorda.nce with the established Position 2._ 1 of Regulatory Guide 1.99, Revision 2, to reflect the expected properties of the reactor vessel beltline materials. CPCo currently has no credible surveillance data for its belt line welds and therefore has no need to use the ratio procedure. until the results of the supplemental surveillance capsules are available.

(4)

A written report providing newly acquired data as specified above and (1) the results of any necessary revisions *to the evaluation of any RPV integrity in accordance with the requirements of 10 CFR 50. 60, 10 CFR 50. 61, Appendices G and H to 10 CFR Part 50, and any potential impact on the L TOP or P-T limits in the technical specifications or (2) a certification that previously submitted evaluations remain valid. Revised evaluations and certifications should include consideration of Position 2. 1 of Regulatory*

Guide 1. 99, revision 2, as applicable, and any new data.

This letter serves as the written report providing the new chemistry information.

The newly acquired information for weld wire heat numbers W5214 and 348009 is limited to the additional chemistry performed on the_ Palisades steam generator welds and is provided in Attachments 4 and 5. The newly acquired information for

  • weld wire heat number 27204 is limited to the results from testing the weld from Capsule Y of the Diablo. Canyon 1 surveillance program, and the results of testing the Fort Calhoun nozzle cutout. This newly acquired chemistry information does not substantially alter the best estimate copper and nickel concentrations previously reported in the SER. Where changes occurred, the previous chemistry values were conservative.

Based on the minor changes in the conservative direction of the best estimate chemistry weight percentages, this letter hereby certifies that the conclusions reached previously in NRG letters dated 6/5/92 and 4/12/95 remain valid. No revisions to any reactor vessel integrity evaluations are planned.

SUMMARY

OF COMMITMENTS There are no new commitments in this submittal.

\\=)::s* s;:> ~

Richard W, Smedley Licensing Manager CC Administrator, Region Ill, USNRC NRC Resident Inspector - Palisades Project Manager, NRR, USNRC 4

CONSUMERS POWER COMPANY To the best of my knowledge, the contents of this response to Generic Letter 92-01, Revision 1, Supplement 1, are truthful and complete.

B~Ul:S..£?*

Richard W Smedley Manager, Licensing

~

Y?

Sworn and subscribed to before me this

  • 17 - day _of ~

1995.

~'W)*.\\0~

Alora M. Davis, Notary Public Berrien County, Michigan (Acting in Van Buren County, Michigan)

My commission expires August 26, 1999

[SEAL]

ATTACHMENT 1 CONSUMERS POWER COMPANY PALISADES PLANT DOCKET 50-255 BEST ESTIMATE CHEMISTRY REACTOR VESSEL WELDS HEAT W5214 1 Page

Weight Percent Copper in Heat W5214 Welds SER New Sample Description Cu%

Cu% '

11 Weight (Cu%) x Weight IP3 nozzle cutout 0.15 0.15 2

0.3 IP3 nozzle cutout 0.15 0.15 2

0.3 IP3 surv.

0.158 0.158 2

0.316 HBR2 torus-flange 0.159 0.159 2

0.318.

I P3 nozzle cutout 0.16 0.16 2

0.32 iP2 surv., region 3 0.19 0.19

.2 0.38 IP2 surv., region 1 0.20 0.20 2

0.40

.1P2 surv., region 2 0.215 0.215 2

0.43 PAL SG, region 3 0.226 0.225#

2 0.45 PAL SG, region 2 0.277 0.268#

2 0.536 Oyster Creek 1 surv.

0.285

.0.285 1

0.285 PAL SG, region 1 0.348 0.311#

2 0.622 HBR2 surv.

0.335 0.335 1

0.335 Sum.

24 4.992 Mean Value 0.212 0.208#

Weight Percent Nickel in Heat W5214 Welds Sample Description SER Ni%

New Ni.% '11 04494 IP2 1-042 0.94 0.94 04541 1.20 1.20 04577 IP2 1.00 1.00 04673 Millstone seam C 1.05 1.05 04674 IP2 3-0428 weld 1.12

1. 12

. 04686. ML 1 2-072A 0.97 0.97 04687 IP2 1-042A weld 0.92 0.92 04688 PAL SG 5-943 0.99 0.99 04690

1. 13 1.13 HBR2 torus-flange weld 0.99 0.99 IP2 surv. weld 1.03
  • 1.03 IP3 surv. weld 1.12 1.12 IP3 nozzle cutout 1.09 1.09 HBR2 surv. weld 0.66 0.66 Palisades SG 1.10 0.99#
  • Mean Value 1.02 1.01 #

NOTES

1) # - indicates revised weight %

ATTACHMENT 2 CONSUMERS POWER COMPANY

. PALISADES PLANT.

DOCKET 50-255 BEST ESTIMATE CHEMISTRY REACTOR VESSEL WELDS HEAT 348009

. 1 Page

Weight Percent Copper in Heat 348009 Welds Sample Description Cu%

Weight (Cu %) x Weight ML 1 surv.

0.184 1

0.184 PAL SG, region 3 0.185 2

0.37 HBR2 torus-dome 0.187 1

0.187 PAL SG, region 2 0.190 2

0.38 PAL SG, region 1 0.190 2

'0.38 Sum 8

1.688 Mean Value 0.188 Weight Percent Nickel in Heat 348009 Welds Sample Description AverageNi %

ML 1 surv. weld 1.05 HBR2 torus-dome weld 0.80 Palisades SG 1.09 Mean Value 0.98

ATTACHMENT 3

. CONSUMERS POWER COMPANY PALISADES PLANT DOCKET 50-255 BEST ESTIMATE CHEMISTRY REACTOR VESSEL WELDS HEAT 27204 1 Page

  • Attachment 3 Weight Percent Copper in Heat 27204 Welds Sample Description Cu%

Weight. (Cu%} x Weight Mihama 6-1 52 0.18 1

0.18 FC 1-41 OB 0.194 8

0.552 05805 & 05927 0.195 1

0.195 DC 1 surv. weld 0.198 1

0.198 Salem 6-0468 0.223 1

0.223 PAL 1-982 0.23 1

0.23 Sum 13 2.578

.Mean Value 0.198 Weight Percent Nickel in Heat 27204 Welds Sample Description Average Ni%

Mihama 6-1 52 0.96 DC1 surv. weld 1.00 05805 & 05927 1.01 PAL 1-982 1.05

  • FC 1-4108 1.07 Mean Value 1.02

ATTACHMENT 4 CONSUMERS POWER COMPANY PALISADES PLANT DOCKET 50.-255 TOTAL CHEMISTRY RESULTS PALISADES STEAM GENERATOR WELDS HEAT W5214 2 Pages

Region 1 Ave:

0.311 SER AR1 AAA AX 0.341 0.32 0.24 0.33 0.328 0.31 0.28 0.32 0.345 0.3 0.34 0.31 0.33 0.33 0.32 0.32 0.367 0.33 0.32 0.31 0.365 0.32 0.28 0.27 0.35 0.26 0.27 0.27 0.37 0,26. 0.27 0.27 0.37 0.39 0.36 0.36 0.353 0.35 0.37 0.4 0.359 0.34 0.33 0.31 0.322 0.33 0.33 0.31 0.34 0.31 0.33 0.3 0.35 0.29 0.3 0.28 0.26 0.27 0.27 0.28 0.27 0.27 0.36 0.3 0.31 0.33 0.37 0.39 0.31 0.33 0.37 0.3 0.33 0.3 0.3 0.3 0.32 0.25 0.31 0.27 0.26 0.24 0.27 0.26 0.26 0.28 Region 2 Ave:

0.268 SER AR1 AR1

.0.3l 0.21-0.26 0.31 0.28. 0.3 0.256 0.23 0.36 0.3 0.26 0.34 0.266 0.22 0.23 0.266 0.23 0.26 0.26 0.24 0.26 0.25 0.26 0.24 0.291 0.26 0.22 0.292 0.32 *0.26 0.31 0.32 0.26 0.29 0.32 0.28 0.278 0.23 0.26 0.281 0.23 0.28 0.206 0.26 0.32 0.27 0.22 0.34 0.22 0.26 0.24 0.24 Total Chemistry Results Palisades Steam Generator - W5214 Copper Weight %

2AB 2AM A-A A-8 A-C A-D 2A-A 2A-B 2A-C 0.39 0.34 0.27 0.32 0.33 0.3.

0.31 0.32 0.32 0.39 0.37 0.26 0.3 0.3 0.33

0.3 0.34 0.33 0.36 0.32 0.28 0.33 0.3 0.32 0.3

. 0.32. 0.31 0.31 0.3 0.32 0.33 0.34 0.31 0.32 0.32 0.32 0.31 0.34 0.27 0.3 0.31 0.33 0.3 0.32 0.32 0.31 0.32 0.28 0.31 0.32 0:31 0.28 0.3 0.31 0.28 0.26 0.28 0.3 0.31 0.31 0.27 0.31 0.31 0.27 0.24 0.28 0.31 0.31 0.3 0.31 0.28 0.31 0.39 0.36 0.27 0.31 0.32 0.33 0.25 0.3 0.33 0.36. 0.34 0.27 0.32 0.31 0.3 0.3 0.3 0.32 0.34 0.34 0.28 0.33 0.33 0.33. 0.31 0.31 0:32 0.38 *0.33 0.28 0.32 0.32 0.32 0.28 0.31 0.32 0.32 0.34 0.28 0.32 0.32 0.33 0.27 0.32 0.32 0.3 0.3 0.27 0.31 0.32 0.33 0.28 0.32 0.31 0.28 0.27 0.26 0.3 d.31 0.32 0.27 0.31 0.32 0.. 28 0.26 0.27 0.34. 0.32 0.33 0.28 0.3 0.31 0.26 0.33 0.27 0.32 0.33 0.32 0.28 0.3 0.31 0.33 0.38 0.3 0.33 0.33 0.31 0.3 0.28 0.31 0.36 0.32 0.28 0.32 0.33 0.33 0.28 0.31 0.32 0.32 0.32 0.3 0.33 0.33. 0.3 0.28 0.31 0.33 0.32 0.32 0.31 0.32 0.32 0.33 0.32 0.32 0.27 0.3 0.33 0.32 0.27 0.28 0.28 0.3 0.31 0.32 0.26 0.26 0.28. 0.3 0.26 0.32 Region 3 Ave:

0.225 SER 0.233 0.239 0.202 0.22 0.237 0.228 0.22~

0.22 0.22 2A-D 0.31 0.32 0.33 0.32 0.32 0.32 0.32 0.31 0.31 0.33 0.31 0.33 0.3 0.31 0.3 0.28 0.28 0.3 0.31 0.33 Page 1 of 2

-~-

Ave:

0.989 SER AR1 AR1 AAA AX 1.093 0.96 0.54 0.47 0.46 1.116 1.2 0.57 0.51 0.26 0.831 1.18 0.45 0.46 o.. 28 1.09 1.15 0.92 0.88 0.36 1.003 0.62 1.06 0.99 0.97 1.006 1.12 1.17 1. 1 1. 11 1.101. 1.08 1.03 1. 11 1. 1 1.05 0.97 1.13 1.18 1.12 1.09 1

0.79 0.51 0.51 1.104 6.87 0.54 0.42 1.093 0.65 0.75 0.63 1. 1 0.68 0.72 0.83 1.154 0.55 1.2 0.91 1.193 0.53 1.24 1.04 1.232 0.52 1.12 1.13 1.23 1.06 1.27 1.34 1.29 1.14 0.49 0.51 1.156 1.2 0.54 0.51 1.. 127 1.09 0.44. 0.33 0.983 1.15 0.85 0.53 1.18 1.03 1.04 0.94 1.059 1.13 1.09 1. 1

. 1.066 1.13 1.06 1. 11 1.031 0.99 1.12 1.31 1.16 1.3 1.203 1.23 1.204 1. 11 1.04 0.99 1.15 1.02 1.29 0.76 1.149 0.54 0.96 0.53 1.051 0.49 1.22 0.79 1.024 0.8 1.107 1.14 1.002 1.2 1.18 1.16 1. 11 1.38 1.4 1.05 1.05 1.08 1.14 1.17 1. 1 1.18 1.03 1.03 0.99 0.5.

Total Chemistry Results Palisades Steam Generator - W5214 Nickel Weight %

2AB 2AM A-A A-B

. A-C A-D 2A-A 0.48 0.5 1.2 1.08 1.06 0.99 1. 11 0.6 0.6 1. 1 1

1.06 1.03 1.08 0.42 0.43 1.12 1.08 1. 1 1.05 1.07 0.83 0.78 1.17 1.05 1.12 1.15 1.19 1.09 1.04 1.12 1.15 1.08 1. 1 1.08 1.1.3 1.15 1.18 1.18 1.12 1.06 1. 1 1. 11 1.08 1. 1 1.08 1.06 1.06 1.08 1.16 1.13 1.14 1.01 1. 1 0.97 1.28 0.6 0.46 1. 1 1

1.06 1.07 0.98 0.79 0.91 1.07 1.04 1.05 1.03 1.1 0.88 0.83

.1.01 1

0.98 0.97 1.15 0.78 0.74 1.15 0.99 1.01 0.99. 1.28 1. 1 1.12 1.05 0.94 1.1 0.79 1.06 1.15 1.16 1.05. 0.9 0.76' 0.73 1.12 1.18 i.16 1.03 0.86 0.94 0.77 1.08 1.25 1.26 1.07 0.98 0.93 0.77 1.2 0.47 0.53 1. 1 0.92 0.9 0.9 1.13 0.5 0.51

1. 11 0.87 0.92 0.. 89 1.13 0.46 0.41 1.13 0.87 0.87 0.78 1.04 0.84 0.85 1.08 0.91 0.89 0.75 1. 1 1.03 1.38 1.07 1.08 0.87 0.92 1.09 1.51 1.01 1.17 0.89 0.91 0.25 1.48 1

1.04 0.94 0.9 1.17 1.08 1.13 1.12 0.82 1.04 2A-B 2A-C 1. 1 1.12 1.15 1.2 1.04 1.12 1.08 1.05 1.08 1. 11 1.13 1.08 1. 1 1.08 1. 1 1. 1 1.05 1. 1 1.01 1.08 1.07 0.99 1.05 1. 1 1. 1 1. 11 1.12 1.13 1.07 1. 1 1. 1 1. 1 1. 1 1. 11 1.07 1.08 0.94 i.07 1. 1 1.08 Page 2 of 2 2A-D 1.17 1.03 0.94 0.96 0.99 1.47 0.97 1.14 1.05 0.97.

1 0.98 1.46 1.01 0.99 1.03 0.92 1.12 1.03

~* -

ATTACHMENT 5 CONSUMERS POWER COMPANY PALISADES PLANT DOCKET 50-255 TOTAL CHEMISTRY RESULTS PALISADES STEAM GENERATOR WELDS HEAT 348009 2 Pages

Region X Ave:

0.185 SER BR1 BAA 0.235 0.18 0.2 0.198 0.18 0.17 0.167 0.21 0.17 0.21 0.18 0.17 0.195 0.21 0.19 0.191 0.2 0.2 0.185 0.2 0.19 0.18 0.18 0.18 0.162 0.17 0.18

.0.165 0.21 0.17 0.146 0.21 0.2 0.15 0.21 0.. 17 0.2 0.18 0.2.

0.19 0.17 0.18 0.16 0.15 0.18 0.17 0.19 0.19 0.19 0.15 0.21 0.15 0.18 Region V Ave:

0.190 SER BR1 0.189 0.18 0.198 0.19 0.193 0.2 0.18 0.18 0.195 0.17 0.192 0.18 0.19 0.17 0.18 0.21 0.208 0.2 0.203 0.21 0.211 0.21 0.2 0.2 0.17 0.16 0.2 0.2 0.18 0.2 0.18 0.2 0.13 Total Chemistry Results Palisades Steam Generator - 348009 Copper Weight %

BX 2BB 2BM B-A B-B B-C B-D..

2B-A 2B-B 0.19 0.17 0.19 0.19 0.19 0.19 0.17. 0.2 0.2 0.2 0.18 0.18 0.17 0.15 0.18 0.17 0.21 0.2 0.18 0.19 0.15 0.2 0.19 0.17 0.2.

0.17 0.19 0.2 0.19 0.18 0.2 0.2 0.19 0.19 0.2 0.19 0.19 0.2 0.19 0.19 0.2 0.19 0.2 0.19 0.17 0.17 0.21 0.20 0.2 0.2 0.19 0.22 0.18 0.19 0.18. 0.22 0.19 0.2 0.19 0.2 0.18 0.19 0.18 0.18 0.18 0.18 0.2 0.19 0.2 0.18 0.2 0.18 0.15 0.15 0.17 0.18 0.19 0.18 0.15 0.2 0.18 0.17 0.19 0.19 0.18 0.18 0.19 0.17 0.2 0.2 0.17 0.19 0.19 0.19 0.19 0.17 0.18 0.18 0.19 0.18 0.21 0.18 0.19 0.19 0.18 0.17 0.19 0.18 0.2 0.21 0.18 0.19 0.19 0.19 0.19 0.19 0.18 0.19 0.2 0.21 0.18 0.19 0.19 0.2 0.18 0.18 0.18 0.14 0.17 0.18 0.18 0.19 0.15 0.2 0.18 0.17 0.17 0.18 0.17 0.15.

0.18 0.18 0.19 0.18 0.19 0.19 0.18 0~8 0.18 0.18 0.18 0.19 0.18 0.19 0.2 0.17 o.. 19 0.18 0.17 0.18 0.17 0.18 0.19 0.2 0.19 0.2 0.18 0.2 0.19 0.19 0.17 0.18 0.19 0.19 0.2 0.19 0.18 0.18 0.14. 0.17 0.19 Region Z Ave:

0.19 SER 0.2 0.18 0.18 0.18 0.2 0.2 0.18 0.17 0.2 0.2 0.2 0.19

.0.2 0.2 0.18 0.2 0.19 0.18 0.19 0.2 0.17 2B-C 0.19 0.19 0.18 0.19 0.2 0.18 0.19 0.2 0.19 0.18 0.2 0.17 0.18 0.17 0.18 0.17 0.17 0.19 0.18 0.18 2B-D 0.2 0.2 0.19 0.19 0.2 0.19 0.19 0.18 0.18 0.17 0.18 0.17 0.18 0.19 0.18 0.18 0.18 0.18 0.17 0.19 Page 1 of 2

Ave:

1.090 SER BR1 BR1 BAA BX 1.215 0.91 1.01 0.81 0.72 1.092 1.36 1.2 0.78 0.99 1.106 1.18 0.89 1.01 0.91 1.18 1.13 0.73 1.12 0.97 1.01 0.73 0.66 1.02 1.02 0.906 1.19 0.5 1.15 1.13 1.218 1.25 0.81 1.24 1.15 o.94 1.12 1.06 0.7 0.41 1.098 0.8 1.05 1.06 0.88 1.057 1 1.09 1.2 0.56 1.148 1.06 1.09 1.26 1.12 1.05 1.01 1.28 1.04 1.13 1.272 0.89 1.16 1.18 1.256 0.68 1.12 1.46 1.234 1. 1 0.74 0.84 1.29 1.33 0.79 1.05 1.331 1.04 1.04 1.26 1.292 0.97 1. 11 1. 11 1.18 1.16 1. 1 1.04 1.33 1.08 1.05 1.17 1.138 1.19 1.2 1.18 0.998 1.13 1.15 1.56 1.14 1.34 1.126 0.96 1.117 1.23 1.119 1.2 1.21

. 1.18 1.136 1. 11 1.088 0.95 0.981 0.91 1.14

. 1.04 1.307 1 1.292 0.69 1.2 0.57 1.38 0.36 0.97 0.56 l.34 1.24 1.17 1.3 1.02 1.01 1.23 0.97 1. 11 1.2 0.12 0.99 1.06 Total Chemistry Results Palisades Steam Generator - 348009 Nickel Weight %

2BB 2BM B-A 8-B B-C B-D 0.98 0.67 1.12 1. 1 1.14 1.15 1.09 0.89 0.99 1.01.

1.06 1.17 1.36 1.09 1.03 1.13 1.17 1.26 1.08. 1.09 1.24 1.15 1. 11 <

1. 1 1.17 1.25 1.15 1.15 1.13 1.19 1.12 1.38 1. 11 1.13 1.08 1.12 1.13 1.12 1.06 1.07 1.15 1.03 1.46 0.58 1. 11 1.07 1.34 1.03 0.85 1.01 1.13 1.03 1.01 0.96 1.12 1.13 1.13 1.05 1. 1 1.32 1. 1 1.18 1.12 1.07 1.08 1.05 1.2 1.16 1.18 1.24 1.04 1.05 1.17 1.13 1.28 1.15 1.06 1.17 1.13 1.2 1.15 1.28 1. 1 <.I 1.28 0.49 0.71 1.42 1.19 1.07. 1.07 1.02 1. 1 1.21 1. 1 1.12 1. 1 1.15 1.13 1.19.

1.22 1.08 1.07 1.17 1.15 1.18 1.24 1. 11 1.07 1.75 1.13 1.15 1.08 1. 11 1.05 1.06 1.23 1.35 1.13 1.06 1.06 2B-A 1.21 1. 1 1.04 1.06 1.08 1.17 1.15 1.15 1.08 1.08 1.06 1.12 1.08 0.93 1.08 0.98 1.18 0.98 1.07 1.04 2B-B 2B-C 1.14 1.05 1.18 1.08 1.04 1.1 1.01 1. 11 1.03 1.12 1.06 1.05 1.08 1.13 1.08 1.22 1.13 1. 1 1.13 1. 1 1. 1 1.04 0.97 1.14 1.03 1.21 1.01 1.12 1. 11 1.13 1. 11 1. 1 1.07 1.14 1.29 1.14 1.13 1.17 1.12 1.24 Page 2 of 2 2B-D 1.14 1.07 1.08 1.03 1. 11 1.22.

1.15 1. 11 1.27 1.01

. 1.25 0.99 1.15 1.19 1.18 1.14 1.12 1.22 1.2 1.18