Advises That Palisades Completed Insp of SG Tubes on 950719. Insp Identified No Pluggable Defects
ML18064A850
Person / Time
Site: Palisades 
Issue date: 07/26/1995
From: Haas K
CONSUMERS ENERGY CO. (FORMERLY CONSUMERS POWER CO.)
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
NUDOCS 9508010169
Download: ML18064A850 (1)


Text

KurtM.Haas Plant Safety and Licensing Director POWERING lllllClll&AN"S l'IUl&llESS Palisades Nuclear Plant: 27780 Blue Star Memorial Highway, Covert, Ml 49043 July 26, 1995 U S Nuclear Regulatory Commission Document Control Desk Washington, DC 20555 DOCKET 50-255 - LICENSE DPR PALISADES PLANT COMPLETION OF THE INSERVICE INSPECTION OF THE STEAM GENERATOR TUBES Palisades Technical Specification 4.14.6a requires that the number of tubes plugged in each steam generator shall be reported to the NRC within fifteen days following the completion of the inservice inspection of steam generator tubes.

On July 19, 1995, the inservice inspection of the Palisades steam generators was completed. Approximately 20% of the tubes in each steam generator, along with tubes showing previous indications, were tested using the bobbin coil test method.

This same 20% sample was then tested at the hot leg top-of-tubesheet transition region using a motorized rotating pancake coil (MRPC).

Additionally, approximately 320 tubes were inspected at the hot leg top-of-tubesheet transition region using the Zetech plus-point probe.

The inservice tnspection identified no pluggable defects.

In accordance with Palisades Technical Specification 4.14.6b, a complete steam generator inservice inspection report will be provided within 12 months.

SUMMARY

OF COMMITMENTS Th-is letter contains no new commitments and no revisions to existing commitments.

~,A lQlQ_~ r Kurt M. Haas Plant Safety and Licensing Director CC Administrator, Region III, USNRC Project Manager, NRR, USNRC NRC Resident Inspector - Palisades