Text

April 12, 1995 Mr. Kurt M. Haas Plant Safety and Licensing Director Palisades Plant 27780 Blue Star Memorial Highway Covert, MI 49043

SUBJECT:

PALISADES PLANT - PRESSURIZED THERMAL SHOCK SAFETY EVALUATION (TAC NO. M83227)

Dear Mr. Haas:

We have reviewed your submittals for the Palisades Plant provided in response to the pressurized thermal shock (PTS) rule, 10 CFR 50.61.

Results of our review are provided in the enclosed safety evaluation.

As a result of the evaluation, the staff has determined that the Palisades reactor pressure vessel can be operated in compliance with the requirements of 10 CFR 50.61 through the plant's 14th refueling outage.

In accordance with 10 CFR 50.61, 3 years prior to exceeding the PTS screening criteria, Consumers Power Company shall submit a plant-specific analysis to determine if operation beyond the screening criteria is acceptable. Submission of information on annealing will obviate the need for a plant-specific analysis.

If you have any questions regarding the enclosed safety evaluation or our review, please contact Marsha Gamberoni of my staff at (301) 415-3024.

Sincerely, ORIGINAL SIGNED BY Elinor G. Adensam, Acting Director Division of Reactor Projects - III/IV Office of Nuclear Reactor Regulation Docket No. 50-255

Enclosure:

Safety Evaluation cc w/encl:

See next page DISTRIBUTION

~l~te:.G1~'t""~~£l~e~s.'

B. Sheron R. C. Jones, Jr.

PUBLIC G. Lainas K. Wichman PDIII-1 Reading G. Holahan B. Elliot W. Russell E. Adensam (e-mail)

S. Sheng R. Zimmerman J. Hannon E. Hackett A. Thadani J. Strosnider C. Jamerson DOCUMENT NAME:

G:\\WPDOCS\\PALISADE\\PAL83227.SE M. Gamberoni L. Lois OGC-WF ACRS (4)

W. Kropp, Riii SEDB To receive a copy of this document, indicate in the box: "C" = Copy without attachment/enclosure* "E" = Copy with attachment/enclosure "N" =No copy OFFICE LA:PD31 NAME DATE 9504140254 950412 PDR ADOCK 05000255 P

PDR

~ PM: PD31 MGambero OFFICIAL RECORD COPY

... r Mr. Kurt M. Haas Consumers Power Company cc:

Mr. Thomas J. Palmisano Plant General Manager Palisades Plant 27780 Blue Star Memorial Highway Covert, Michigan 49043 Mr. Robert A. Fenech Vice President, Nuclear Operations Palisades Plant 27780 Blue Star Memorial Highway Covert, Michigan 49043 M. 1. Miller, Esquire Sidley & Austin 54th Floor One First National Plaza Chicago, Illinois 60603 Mr. Thomas A. McNish, Secretary Consumers Power Company 212 West Michigan Avenue Jackson, Michigan 49201 Judd L. Bacon, Esquire Consumers Power Company 212 West Michigan Avenue Jackson, Michigan 49201 Regional Administrator, Region III U.S. Nuclear Regulatory Commission 801 Warrenville Road lisle, Illinois 60532-4351 Jerry Sarno Township Supervisor Covert Township 36197 M-140 Highway Covert, Michigan 49043 Office of the Governor Room 1 - Capitol Building Lansing, Michigan 48913 U.S. Nuclear Regulatory Commission Resident Inspector's Office Palisades Plant 27782 Blue Star Memorial Highway Covert, Michigan 49043 Palisades Plant Nuclear Facilities and Environmental Monitoring Section Office Division of Radiological Health Department of Public Health 3423 N. Logan Street P. O. Box 30195 Lansing, Michigan 48909 Gerald Charnoff, Esquire Shaw, Pittman, Potts and Trowbridge 2300 N Street, N. W.

Washington DC 20037 Michigan Department of Attorney General Special Litigation Division 630 Law Building P.O. Box 30212 Lansing, Michigan 48909 Febnuuy 1995