ML18064A683

From kanterella
Jump to navigation Jump to search
Degraded Sealing Capability of Inner Door of Personnel Air Lock
ML18064A683
Person / Time
Site: Palisades 
Issue date: 04/06/1995
From: Haas K
CONSUMERS ENERGY CO. (FORMERLY CONSUMERS POWER CO.)
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
Shared Package
ML18064A684 List:
References
NUDOCS 9504120168
Download: ML18064A683 (1)


Text

r.onsumers Jlower POWEIUll&

MIUll&All-S l'IUllillE5S Palisades Nuclear Plant: 27780 Blue Star Memorial Highway, Covert, Ml 49043 April 6, 1995 Nuclear Regulatory Conunission ATTN:

Document Control Desk Washington, DC 20555 DOCKET 50-255 - LICENSE DPR PALISADES PLANT KurtM. Haas Plant Safery and Ucensing Director "LICENSEE EVENT REPORT 95-002 - DEGRADED SEALING CAPABILITY OF INNER DOOR OF PERSONNEL AIR LOCK Licensee Event Report (LER)95-002 is attached. This event is reportable to the NRC per 10CFR50.73(a)(2)(i)(B) as operation of the plant in a condition prohibited by the plant's Technical Specifications.

SUMMARY

OF COMMITMENTS This letter contains one new commitment identified below.

Evaluate the airlock door seal preparation activities of Maintenance Procedure CLP-M-.4 to determine why the personnel air lock inner door did not successfully pass the between-the-seals local leak rate test, DW0-13.

Kurt M. Haas Plant Safety and Licensing Director CC Administrator, Region Ill, USNRC NRC Resident Inspector - Palisades Attachment 110156 9504120168 950406 PDR ADOCK 05000255 S

PDR A CM5 ENERGY COMPANY