Discusses Licensee Response to GL 89-10,Supp 5, Inaccuracy of MOV Diagnostic Equipment
ML18059A657
Person / Time
Site: Palisades 
Issue date: 01/31/1994
From: Hsia A
Office of Nuclear Reactor Regulation
To: Slade G
CONSUMERS ENERGY CO. (FORMERLY CONSUMERS POWER CO.)
References
GL-89-10, TAC-M87980, NUDOCS 9402100062
Download: ML18059A657 (3)


Text

.. *'

  • O)

UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON. D.C. 20666-0001 January 31, 1994 Docket No. 50-255 Mr. Gerald B. Slade Plant General Manager Palisades Plant Consumers Power Company 27780 Blue Star Memorial Highway Covert, Michigan 49043

Dear Mr. Slade:

SUBJECT:

PALISADES PLANT - GENERIC LETTER 89-10, SUPPLEMENT.5, "INACCURACY OF MOTOR..:OPERATED VALVE DIAGNOSTIC EQUIPMENT" (TAC M87980)

On June 28, 1993, the NRC staff issued Supplement 5, "Inaccuracy of Motor-.

Operated Valve Diagnostic Equ~pment," to Generic Letter (GL) 89-10, "Safety-Related Motor-Operated Valve Testing and Surveillance," requesting nuclear power plant licensees and construction permit holders (1) to re-examine their MDV programs and to identify.measures taken to account for uncertainties in properly setting valve operating thrust to ensure operability, and (2) to evaluate the schedule necessary to consider the.new information on MDV diagnostic equipment inaccuracy and to take appropriate action in response to that information. Within 90 days of receipt. of Supplement 5 to GL 89-10, licensees were required (1) to notify the NRC staff of the diagnostic equipment used to confirm the proper size, or to establish settings, for safety-related MOVs, and (2) to report whether they had taken actions or

  • planned to take actions (including schedule) t~ address the new information on the accuracy of MDV diagnostic equipment.

The staff has reviewed the responses, and has found that, for the most part, licensees and permit holders have be.en actively addressing the uncertainties regarding the accuracy of MDV diagnostic equipment.

The increased inaccuracy of MDV diagnostic equipment can raise questions regarding (1) the adequacy of torque switch settings to provide sufficient thrust while not exceeding thrust or torque structural limits and (2) the capability of actuator motors at current settings.

In their responses, licensees and permit holders indicated that many MOVs had the potential for underthrusting or overthrusting as a result of the higher than expected inaccuracy of MOV diagnostic equipment.

Consequently, some licensees reported that MOVs have been retested, adjusted, or modified to resolve the concerns regarding the accuracy of MDV diagnostic equipment.

In your response dated September 30, 1993, you stated that Consumers Power Company (CPCo) uses Liberty Technologies' VOTES equipment f.~r MDV diagnostic testing.

You also stated that CPCo currently uses the VOT~S 2.3 software and that all MOVs set up with VOTES equipment prior to receiving the 2.3 software had been evaluated and all were found to be operable.

During a future inspection, the NRC staff will discuss CPCo's resolution of the MDV diagnostic equipment accuracy issue.

9402100062 9401 31,.

  • I 'j*

PDR" ADOCK 050002$5 I p

PDR..

...~.

  • ,J*.

l*,

r...

e Mr. Gerald January 31, 1994 This completes all efforts on TAC M87980. If you have any questions regarding this issue, please call me at (301) 504-3028.

cc:

See next page DISTRIBUTION cDo.~~et~F.;-i::l!t;)

NRC & LPDRs JZwoliriski LMarsh ARBlough AHHsi a.

CJamerson OGC ACRS(lO)

BJorg.en sen, RI I I AHsnsen TScarbrough 7/E/23 OFFICE LA: PD3 l NAME CJamerson DATE OFFICIAL RECORD COPY l

Sincerely, Original signed by Anthony H. Hsia, Project Manager * -

Project Directorate 111-1 Division of Reactor Project's - 111/IV/V'

  • Office of Nuclear Reactor Regulation A D:PD31 ARBlou h I st: 94 FILENAME:

G~\\WPDOCS\\PALISADE\\PAL87980.GL

-<(*

Mr. Gerald B. Slade Consumers Power Company cc:

M. I. Miller, Esquire Sidley & Austin 54th Floor One First National Plaza Chicago, Illinois 60603

~

Mr. Thomas A. McNish, Secretary.

Consumers Power Company 212 West Michigan Avenue Jackson, Michigan 49201 Judd L. Bacon, Esquire Consumers Power Company 212 West Michigan Avenue Jackson, Michigan 49201 Regional Administrator, Region III U.S. Nuclear Regulatory Commission 801 Warrenville Road Lisle, Illinois 60532-4351 Jerry Sarno Township Supervisor Covert Township 36197 M-140 Highway Covert, Michigan 49043 Office of the Governor Room 1 - Capitol Building Lansing, Michigan 48913 Mr. David W. Rogers Safety and Licensing Director Palisades Plant 27780 Blue Star Memorial Highway Covert, Michigan 49043 U.S. Nuclear Regulatory Commission Resident Inspector Office Palisades Plant 27782 Blue Star Memorial Highway Covert, Michigan 49043 Palisades Plant Nuclear Facilities and Environmental Monitoring Section Office Division of Radiological Health Department of Public Health 3423 N. Logan Street P. 0. Box 30195 Lansing, Michigan 48909 Gerald Charnoff, Esquire Shaw, Pittman, Potts and Trowbridge 2300 N Street, N. W.

Washington DC 20037 Alora Davis Commitment Tracking System Coordinator Palisades Plant Consumers Power Company 27780 Blue Star Memorial Hwy.

Covert, Michigan 49043-9530 December 1993