ML18059A581

From kanterella
Jump to navigation Jump to search
Forwards Insp Rept 50-255/93-23 on 930920-1127.No Violations Noted.Util Consideration of Generic Aspect of PWSCC Failure Considered Weak
ML18059A581
Person / Time
Site: Palisades Entergy icon.png
Issue date: 12/23/1993
From: Wright G
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
To: Slade G
CONSUMERS ENERGY CO. (FORMERLY CONSUMERS POWER CO.)
Shared Package
ML18059A582 List:
References
NUDOCS 9312300078
Download: ML18059A581 (2)


See also: IR 05000255/1993023

Text

  • ,

v

. ~.* .

UNITED STATES

NUCLEAR REGULATORY COMMISSION

REGION Ill

801 WARRENVILLE ROAD

LISLE. ILLINOIS 60532-4351 .

Docket No. 50-255

Consumers Power Company

ATTN:

Mr. Gerald 8. Slade

Genera T Manager

Palisades Nuclear Generating Plant

27780 Blue Star Memorial Highway

Covert, MI

49043-9530

Dear Mr. Slade:

() <: *a93*

DEC :.., "' 1_

This refers to the inspection conducted* by Mr. J. F. Smith and others of this

office on Se.ptember 20 through November 27, 1993.

The inspection included a

review of activities for your Palisades Nucle~r Power Plant:

At the

conclusion of the inspection, the findings were discussed with thos~ members

of your staff identified in the enclosed report.

The areas examined during the inspection are identified in the report. ' These

areas consisted primarily o.f activities related to the cracks found inthe

pressurizer power operated relief yalve piping.

Within this area, the

inspect-ion consisted of a selective examination of procedures and

reptesentative records, observations, and intervie~s with personnel.

No violations of NRC requirements were identified during the course of this

.inspection.

An appar~nt lack of management involvement was noted early in the repair

effort as evidenced by a slow response in providing a comprehensi~e

inspection/repair plan. Also, your consideration of the generic aspect of

  • this PWSCC failure was considered weak~-

In accordance with-10 CFR 2.790 of'the Commission's tegulations, a copy df

this letter and the enclosed irispection report will be placed in the NRC

Public Document Room.

We will gladly discuss *any questions you have concerning this inspection.

0 80~ 1 '"i

~

~* **- '

Enclosure:

Inspection Report

No. 50-255/93023(DRS)

See Attached Distribution

9312300078 931223

PDR

ADOCK 05000255 .

0

PDR

Sincerely,

~\\t\\v~~

G. c. Wright, Chief

Engineering Branch

. ~ ., '" ;~**)< ~.

  • .*.

Consumers Power Company

Distribution*

cc w/enclosure:

David P. ttoffman, Vice

President, Nuclear Operations

David W. Rogers, Safety and

Licensing Director

OC/LFDCB

Resident Inspector, Riii

James R; Padgett, Michigan

Public Service Commission

Michigan Department of

Public Health

Palisades LPM, NRR

Big Rock Point SRI

G. E. Grant, Riii

2