Text

I JUL 0 B 1993 Docket No. 50-255 Consumers Power Company ATTN:* Gerald B. Slade General Manager Palisades Nuclear Generating Plant 27780 Blue Star Memorial Highway Covert, MI. 49043-9530

Dear Mr. Slade:

This letter confi rm*s our pl ans as discussed between Mr. B. McCabe of this

. office and Mr. T. Palmisano of your staff to hold a* meeting at 12:30 p.m'.

(CDT) on Monday, July 19, 1993, at the NRC. Region III office, 799 Roosevelt Road, Glen Ellyn~ Illinois.

Thismeet.ing is an Enforcement Conforence to discuss the apparent violations pertaining to failure to follow procedures or to establish adequate procedures for disconnecting control rods from the~r drive mechanisms.

At the Enforcement Conference yo~ should be prepared to address the issues identified in Inspection Reprirt No. 50-255/93016.

We appreciate your cooperati~n in this matter.

If you have any questions regarding this meeting, please contact Mr. Brian McCabe of my staff at (708) 790-5689.

cc:

David P. Hoffman, Vice Pre~ident Nuclear Operations David W. Rogers, Safety and Licensing Director OC/LFDCB Resident Inspector, RIII Jam~s R. Padgett, Michigan Public Service Commission Michigan Department of Sincerely,

. Orfgfnar signed by W.*. I; *. l@ffi~,f Edward G. Greenman, Di~ector Division of Reactor Proje~ts Pub 1 i c Hea 1th

___________ -~------- -**------- ______ -- - -

Pa 1 i sadgs_, __ U~M, __ NRR-------- --------- ------------------


- -.--------sRr;-Big Rock Point 9307140028 930708 PDR ADOCK 05000255 G