{{#Wiki_filter:---------------------------------------------- ATTACHMENT Consumers Power Company Pali sades Pl ant Docket 50-255 1992 RADIOLOGICAL ENVIRONMENTAL MONITORING REPORT 9305050179 930428 PDR ADOCK 05000255 R PDR April 28, 1993
I. Introduction The 1992 Palisades Nuclear Plant Annual Radiological Environmental Operating Report provides a summary and data interpretation of the Palisades Radiological Environmental Monitoring Program as conducted during the 1992 reporting period. Reporting requirements are detailed in Palisades Offsite Dose Calculation Manual, Appendix A, sections III.J and IV.B, tables E-1 thru E-3, and table F-1. Palisades was off-line February 7 to April 19 for reactor refueling. The plant was off-line July 1 to July 4 and July 24 to July 29 due to Turbine Control System problems. The plant was off-line August 14 to August 17 due to a failed air line to a feedwater regulating valve and problems with the Turbine Control System. The plant was taken back off-line August 17 to August 18 due to a turbine hydraulic fluid leak. The plant was off-line August 25 to August 27 due to a failed solenoid in the preferred AC bus powering enineering safeguards system electrical loads coupled with an undetected blown fuse. The plant was taken off-line September 19 to September 28 for the investigation of a personnel injury accident. The plant was off-line again October 30 to November 8 due to Turbine Control System problems. There are no remaining 1992 laboratory sample analyses pending completion for inclusion into this report. The results of all environmental samples collected are evaluated as follows: A. Air iodine and particulates, TLDs (monthly and quarterly), and milk data were statistically evaluated at the 95% confidence level (using SAS program) by the methodology detailed in Palisades Procedure HP 10.4. The data was compared against two criteria: the first criterion is the statistical difference which determines if sample results from near sites are significantly greater than those from control sites. The second criterion is the evaluation level (twice the statistical difference) which is the minimum detectable difference that exceeds zero at the 95% confidence level. If the evaluation level is exceeded, then correlation of the results with effluent releases is done. B. Well water, lake water, sediment, fish and other aquatic biota samples were evaluated using data means comparisons against an appropriate control location (if available) and Palisades Technical Specification limtts. II. Reportable Event None III. Discussion and Interpretation of Results A. Air Sample Comparison of the gross beta airborne particulate sample data between near-site and control locations did not exceed the statistical difference. In many instances, control location sample values were greater. There was no I-131 activity reported above LLD. A total of 625 air samples were collected and analyzed during 1992. Five sample results were not included in the statistical evaluation. Refer to Enclosure A for specific reasons for sample rejection. The samples deleted constitute 0.8 percent
of the Iodine-131 and air particulate gross beta total. Palisades ODCM, Appendix A, sensitivities were met on all samples other than those noted. Air iodine/particulate samples are collected on a weekly basis from twelve (12) air sampling locations. Air is metered into the sampling unit at a continuous 1 cfm flow rate through a Gelman 47mm air filter (air particulate) and a Scott air iodine cartridge. Both filters are in-line with each other and housed within the same filter holder. The 1992 air sampler results are consistent with actual effluent releases and site-specific meteorology. B. Lake Water A total of 36 individual monthly lake water composite samples were collected from three (3) locations during 1992. Lake water samples from the Palisades Lake-in (intake), the South Haven Municipal Water system intake (raw water), and Ludington Lake-in (intake) are collected daily and composited into monthly samples. Evaluation of the monthly lake water analytical results was based on a data means comparison between the Palisades Lake-in (indicator), the South Haven Municipal raw water (indicator) and Ludington Lake-in (control) locations. The lake water results were also evaluated against the Palisades Technical Specification reporting limits. Gross beta analyses are required for all lake water samples. The Palisades Lake-in, South Haven Municipal raw water, and Ludington Lake-in samples were below the required LLDs for gross beta. Monthly gross alpha and tritium analyses were also performed on the Palisades Lake-in and Ludington samples for comparison data against the Lake-out (discharge) sample results. Results of the gross alpha and tritium analyses were below LLD. No Palisades ODCM reporting limits were exceeded. Although the lake-out (discharge) sample is not used as an indicator in the Radiological Environmental Monitoring Program it is monitored for activity. Four times during 1992 the tritium activity for the discharge was above the ODCM action level of 1000 pCi/L. These elevated levels were all correlated to liquid effluent discharges and were confirmed by comparison to calculated effluent tritium concentrations. Palisades Lake-in, South Haven Municipal and Ludington Lake-in water samples are collected daily for composite into a monthly sample. One-gallon of Palisades Lake-in water and two gallons each of South Haven Municipal water and Ludington Lake-in water are sent to Teledyne Isotopes for analysis. No treatment of the water samples with preservative is required. C. Drinking water A total of 36 individual monthly drinking water samples were collected from the South Haven Municipal Water System and Ludington Pump Storage Water System during 1992. The South Haven samples are obtained from two collection points: South Haven Municipal Water System intake (raw water) and South Haven
Municipal Water System treated water. The Ludington samples were collected from one collection point, the tap from well water. Samples are collected daily for composite into a monthly sample, for the South Haven raw and treated water samples, and a monthly grab sample is obtained for the Ludington well water sample. The South Haven samples are used as indicating locations and the Ludington samples serve as controls. Evaluation of the drinking water analytical results was based on historical data and a data means comparison between raw water and treated water, as well as a comparison to the Palisades ODCM reporting limits. The evaluated data was also trend plotted against the Palisades Lake-in gross beta results. The indicator and control drinking water samples require both gross beta and tritium analysis except for the South Haven Municipal raw water sample, which only requires a gross beta analysis. For all samples, including Ludington, the analytical results were below LLD for gross beta and tritium. No special or supplemental analyses were required during 1992. A two-gallon quantity of each sample is sent to Teledyne Isotopes for analysis. No treatment of the water samples with a preservative is required. D. Well Water A total of 96 monthly well water samples were collected from eight (8) locations during 1992. The Palisades site well (indicator) is collected daily and composited into a monthly sample. The State Park and Covert Township Park well water samples (controls) are collected as monthly grab samples only. From five other site area wells (indicators), one (1) sample is collected from the warehouse building (WH), one (1) sample is collected from the outage building (OB) and one (1) sample each is collected from the monitoring wells #14, #15 and #16 which were installed to monitor the groundwater around the Steam Generator Storage Facility. The twelve drinking water samples from the Ludington site well (32-LP) also serve as controls. These six (6) sample points (WH, OB, #14, #15, #16 and 32-LP) are sampled once a month by grab sample. Evaluation of the well water analytical results was based on a data means comparison between the six (6) indicator locations and the three control locations as well as with the Palisades ODCM reporting limits. Tritium and gross beta analyses are required for the well water samples. Analytical results were below LLD for tritium at all locations and below LLD for gross beta at the Palisades site, the State Park, Covert Township Park, the Outage Building and Ludington Pump Storage which are drinking water wells. The Warehouse well had a mean of 5.3 pCi/L gross beta, and monitoring wells #14, #15, and #16 had means of 4.8 pCi/L, 5.4 pCi/L and 4.7 pCi/L, respectively. The means for these four wells are slightly above* the 4.0 pCi/L gross beta LLD and are consistent with the mean data for 1991. It should be noted that the Warehouse well and monitoring wells #14, #15, and #16 are not used for drinking.
'1 No Palisades ODCM reporting limits were exceeded for the 1992 well samples. The December site well #14 sample exceeded the gross beta ODCM action level of 10 pCi/L. The December result was 11.2 pCi/L. The result was verified by re-analysis and the necessary supplementary analysis were completed except for an I-131 analysis. The supplementary analyses were all less than LLD. An I-131 analysis is a HP 10.1 procedural requirement not a Palisades ODCM requirement. This deviation was documented by Palisades corrective action system Deviation Report D-PAL-93-026. Site well
- 14 typically trends around 4 to 8 pCi/L and it is not unusuaal for it to exceed the 10 pCi/L action level. A similar trend in the gross beta activity level for site well #14 was observed at about the same time last year.
One (I) one-gallon quantity from the on-site well and two (2) one-gallon quantities of sample for each of the other wells are sent to Teledyne isotopes for analysis. No treatment of the water samples with a preservative is necessary. A total of 48 individual monthly milk samples were collected from 4 different dairy farms (stations 26-FC, 27-KK, 28-GH and 29-WS) during 1992. The milk samples are obtained as grab samples (from dairy milk holding tanks). With the exception of Sr-90, all isotopic results listed in Table 10.4-2 were less than LLD. SAS evaluation of the Sr-90 activity between indicator (26-FC, 27-KK, and 28-GH) and control (29-WS) locations revealed a statistical difference between the indicators and controls, but the difference did not exceed the evaluation level. The indicator. loc~tion (26-FC) had the highest annual Sr-90 mean for 1992 of 3.7 pCi/L. The control location (29-WS) had an annual mean of 2.3 pCi/L. These results are relatively unchanged from 1990 and 1991 results. The difference is not considered significant at these very low values. No special or supplemental analyse~ were required, nor were any Palisades ODCM reporting limits exceeded. Milk samples are required monthly (usually collected the 1st week of the month) from each designated location (4 total). Two one-gallon quantities of raw milk (grab sample) are obtained per sample location in order to meet analytical requirements. Each sample quantity is treated with a sodium bisulfite (40 grams per gallon ) preservative prior to being sent to Teledyne Isotopes. F. TLDs - Gamma Dose There were a total _of 344 monthly, 114 quarterly and 26 annual TLDs collected and analyzed during 1992. Four (4) monthly TLDs, two (2) quarterly TLDs, and three (3) annual TLD were reported missing. Refer to Enclosure A for further details. The Palisades gamma assessment program consists of 30 locations: I directly on-site, 9 inner ring and 6 Steam Generator Storage Facility TLDs for a total of 15 site boundary, 10 outer ring (1.0 to 5.5 miles out), 3 control (30 to 55 miles out) and I TLD control placed in a lead storage cave. For 1992, the average monthly gamma readings were: 3.8 mR for the inner ring TLD's (site boundary) 4.7 mR for the outer ring TLD's (1.0 to 5.5 miles
out), and 4.5 mR for the control TLD locations. The results are consistent with actual effluent releases. The one (1) on-site TLD location (ST-1) serves as an individual reference TLD, however it was evaluated along with the inner ring (site boundary) TLD's in the SAS program. The monthly and quarterly SAS statistical TLD data evaluation were accomplished by comparing the inner ring TLDs (site boundary locations ST-01, ST 13-21 and ST 33-38) and the outer ring TLDs (locations St-02 thru ST-09, ST-23 and ST-24) against the control TLD locations (ST-10 thru ST-12). The annual TLD data evaluation was done by direct comparison of data points only. No monthly or quarterly statistical differences were exceeded. In comparing the inner ring TLDs to the control TLDs ST-11 (Kalamazoo, 34mi SSE) had the greatest monthly mean of 4.8 mR. ST-35 (ENE Site Boundary) had the greatest quarterly and annual exposure of 13.6 mR and 59.0 mR, respectively. When the same comparison was made between the outer ring and control location TLDs, ST-02 {Tower Hill, 5 mi. S) had the greatest monthly, quarterly and annual data mean for any indicator location of 5.6 mR, 17.2 mR and 69.9 mR, respectively. Environmental gamma doses are measured monthly, quarterly and annually by placement of 3 TLD badges per designated location. Each Teledyne TLD badge contains a 4-zone CaS04 wafer (the wafer also includes an additional backup/reserve readout zone). Sensitivity for the multi-zone TLDs are 0.5 mR with a linear response of 0.1 mR to 1000 R. G. Crops The collection of food crops and vegetation samples (when available and in season) is a requirement of the Palisades Radiological Environmental Monitoring Program. Two principal area crops, apples and blueberries, are regularly collected as specified in the ODCM. While there are no designated locations where food crops are collected, samples are generally obtained from the same areas where the air monitoring stations are located within the ESE, SE or SSE sectors. The collection of food crops assists in verifying stack effluent deposition patterns. During 1992, 10 crop samples were collected from two stations (6 samples from station ST-04, 3.5 mi SE and 4 samples from station 5-PR, 3.5 mi ESE). Evaluation of sample analytical results was direct. There was no control location used. Of the isotopic analyses listed on Table HP 10.4-2, only the gross beta resulted in any specific activity {slightly above LLD). All other analyses were less than LLD. The crop samples at station ST-04 had the greatest individual means for gross beta activity of all 10 samples taken. No Palisades ODCM action or reporting levels were exceeded, nor were any special/supplemental analyses required during 1992.
Food crop samples are required to be collected when available and in season. When collected, approximately I Kg of sample is placed in a sealable plastic bag for shipment to Teledyne Isotopes. No special treatment of the samples with a preservative is necessary. H. Sediment
- A total of II individual sediment samples were collected from 5 locations during I992.
Eight (8) sediment samples were obtained from Palisades (discharge, % mi South of discharge, % mi North of discharge and South Haven Beach locations) and three (3) samples from the Ludington*Control Station. Evaluation of the sediment analytical results was based on a data means comparison between Palisades and the Ludington control samples as well as the Palisades Technical Specification reporting limits. The individual Palisades sample locations were combined into one indicator (site) location for comparison purposes; however if any one individual sample location had a greater specific isotopic annual mean than the other location(s), then that location is identified on Table HP 10.4-2. Of the isotopic analyses listed on Table HP I0.4-2, only gross beta activity was detected at levels above the required LLD level. Location 25-SH (South Haven Beach) had the greatest mean for gross beta. No Palisades ODCM action or reporting levels were exceeded, nor were any special/supplemental analyses required during I992. Sediment samples are collected semi-annually from each designated location. A one (I) liter quantity grab sample usually is obtained off-shore. No treatment of the samples with a preservative is necessary prior to shipment to Teledyne Isotopes. I. Aquatic Biota - Algae No algae was collected for analysis during I992. Algae was not available in sufficient sample quantities during I992 to warrant collection and analysis. The Palisades Radiological Environmental Monitoring Program does not require alage to be collected, althouth it has been collected in the past when available. One (I) liter quantities of algae (if available) are prepared for shipment to Teledyne isotopes by treating each sample with IO ml of a IO% formaldehyde solution for preservation. J. Fi sh A total of 2I individual fish samples were collected from two (2) locations during two (2) separate sample collections in I992. Eleven (II) fish samples were obtained from Palisades (discharge) and.ten (IO) samples from the Ludington Control Station. Evaluation of the fish analytical results was based on a data means comparison between the Palisades and Ludington Control Samples as well as with the Palisades ODCM reporting limits. Of the isotopic analyses listed on Table HP I0.4-2, only gross beta activity was greater than LLD. No Palisades ODCM action levels or reporting levels were exceeded nor were any special analyses requested for I992.
K. As a minimum, at least two (2) different fish species (ie, forage, sport fish, etc) per designated location per year are collected. When caught, a one (1) liter quantity of fish sample is prepared for shipment to Teledyne Isotopes. Each sample is treated with 10 ml of a 10% formaldehyde solution for preservation. Broad Lead Vegetation No broad leaf vegetation samples were collected from the surrounding Palisades environs during 1992. The collection of broad leaf vegetation samples serves as a backup and/or alternative sampling media in case any milk sampling location(s) become(s) unavailable. There were no problems associated with the quantity or quality of milk samples for the 1992 reporting year. L. Non-Routine Samples None M. Gaseous and Liquid Radwaste Effluent Composite Samples Although not a direct reporting component in the Palisades Annual Radiological Environmental Monitoring Report, results of the gaseous and liquid monthly radwaste effluent composite samples are evaluated against overall environmental trending data. This evaluation is the basis for determining isotopic dispersion and deposition patterns within the surrounding environs of Palisades. All results are compared against Palisades ODCM radioactive effluent LLDs. All isotopic LLDs were met. Both the gaseous and liquid radwaste effluent composite samples are collected monthly and sent to Teledyne Isotopes for analysis. The liquid effluent composite sample is based on a specific ratioed volume amount of sample collected per total batch volume release. The gaseous radwaste effluent composite sample results are based on analyzing four (4) or five (5) weekly stack gas filters. No special sample treatment with a preservative is required prior to laboratory analysis. III. Assessment of Palisades Operation Environmental Impact In reviewing the 1992 Palisades radiological environmental monitoring data and comparing it to previous operational and pre-operational data, all trending parameters continue to indicate that the operation of Palisades has minimal environmental impact. Most isotopic activity is at environmental background levels. Since the Chinese stopped open atmospheric testing of nuclear devices in late 1981-82, environmental background radiation levels continue to decrease. The effect of the Chernobyl fallout (April 1986) on milk, aquatic biota and fish also appears to have had no lasting results. Evidence of an overall environmental isotopic buildup (attrjbutable to Plant effluents) remains negligible as well. In most instances, sample analytical results were below previously established environment background levels.
Medium Air Lake Water Drinking Water Well Water Milk TLD Crops Sediment Aquatic Biota Description Continuous at Approx 1 CFM 1 Gallon Composite 1 Gall on Composite/Grab 1 Gall on Grab 2 Gall on Grab Continuous Grab Grab Grab Palisades Nuclear Plant, Va n County, Mi. Docket 50-255 Annual Radiological En nmental Operating Report January 1 to December 31, 1992 Table HP 10.4-1 Sampling and Analysis Summary Location All: Stations 1-st thru 12-DG Intake, South Haven Raw & Ludington South Haven Municipal Treated and Raw, & Ludington Site, TP, SP, OB, WH, Ludington, MV#14, #15, #16 WS, FC, GH, KK All: Stations ST-01 thru ST-24 and ST-33 thru ST-38 JS, PR Discharge, 0.5 mi N & S Site Boundary South Haven Beach Ludington Control Discharge, 0.5 mi South of Discharge, Ludington Control Number of Samples Collected 625 36 36 96 48 344 114 26 10 11 0 Type of Analysis Gross Beta, 1-131 Gross Beta, *Gross Alpha,
- Trit*i um Gross Beta, *Tritium Gross Beta, Tritium 1-131, Sr-89 and Sr-90, Cs-137, Other Gamma Gamma Gross Beta, Sr-89 and Sr-90, Cs-137, Other Gamma Gross Beta, Sr-89 and Sr-90, Cs-137, Other Gamma Gross beta, Sr-89, Sr-90 Other Gamma Fish Grab Discharge, South, 21 Gross Beta, Sr-89, Sr-90 Other Gamma Ludington Control
- NOTE:
Not required for South Haven Municipal raw water. Frequency of Analysis Weekly Monthly Monthly Monthly Monthly Monthly Quarterly Annual In Season Semi-Annual As re-quested Semi -Annua 1
Medium or Analyses Evaluated/ Pathway Sam11led Analyses Performed Unit of Measurement Air (pCi/m3 ) I-131 620/625 Gross Beta 620/625 Lake Water (pCi/L) Gross Alpha(f) 24/24 Gross Beta 36/36 Tritium(f) 24/24 Drinking Water Gross Beta 36/36 (pCi/L) Tritium(f) 24/24 Well Water Gross Beta 96/96 (pCi/L) Tritium 96/96 Milk (pCi/L) l-131 48/48 Sr-89 48/48 Sr-90 48/48 Cs-137 48/48 Other Gamma 48/48 Palisades Nuclear Plant, Van Buren County, Mi. Docket 50-255 Annual Radiological Environmental Operating Report January 1 to December 31, 1992 Table HP 10.4-2 Sample Data Summary Lower Limit All of Indicator Location With Greatest Detection{a} Locations Annual Mean LLD Mean(b) Name Mean(b) Range(b) Distance and Direction Range(b) 0.07 465/468 LLD LLD 0.01 465/468 0.019 ST-12 (Control-Dowagiac 0.025 (0.004-0.039) 30 mi SSE) (0.016-0.052) 1.0 12/12 LLD LLD 4.0 24/24 LLD LLD 500.0 12/12 LLD LLD 4.0 24/24 LLD LLD 500.0 12/12 LLD LLD 4.0 72/72 LLD ST-42 (Site Monitoring 5.4 Well #15) (3.3-7.6) 500.0 72/72 LLD LLD 1.0 36/36 LLD LLD 5.0 36/36 LLD LLD 1.0 36/36 3.2 ST-26 (F. Crnkovich, 3.7 (2.0-6.3) 7.5 mi NE) (2.2-6.3) 18.0 36/36 LLD LLD 15.0 36/36 LLD LLD (1) 12 of these control samples were from the drinking water media control locations. All
- Control Nonroutine Locations Re11orts{cl Mean(b)
Range(b) 155/157 LLD None 0.021 None (0.006-0.052) 12/12 LLD None 12/12 LLD None 12/12 LLD None 12/12 LLD None 12/12 LLD None 36/36(1) LLD None 36/36(1) LLD None 12/12 LLD None 12/12 LLD None 12/12 2.3 None (1.5-3.1) 12/12 LLD None 12/12 LLO None
Medium or Pathway Sampled TLD (gamma mR) Inner Ring (Site Boundary) TLD (gamma mR) Outer Ring Crops (pCi/g wet) Palisades Nuclear Plant, Van Buren County, Mi. Docket 50-255 Annual Radiological Environmental Operating Report January 1 to December 31, 1992 Table HP 10.4-2 Sample Data Summary Lower Limit All Analyses Evaluated/ of Indicator Location With Greatest Analyses Performed Detection Cal Locations Annual Mean TLD (monthly) (e) 225/225 10.0 191/191 3.8 ST-11 (Control-Kalamazoo 4.8 TLD (quarterly) (e) 75/75 10.0 (1.9-5.6) 64/64 11.3 35 mi SSE) (3.2-5.5) ST-35 (ENE Site 13.6 TLD (annual) 17/17 10.0 (9.4-14.2) 15/15 48.1 Boundary) (13.l-14.2) ST-35 (ENE Site 59.0 (42.0-59.0) Boundary) TLD (monthly)(e) 119/119 10.0 119/119 4.7 ST-02 (Tower Hill 5.6 (2.7-7.0) Farm, 5 mi S) (4.3-7.0) TLD (quarterly)(e) 39/39 10.0 39/39 13.7 ST-02 (Tower Hill 17.2 (10.0-19.2) Farm, 5 mi S) (15.4-19.2) TLD (annual) 9/9 10.0 9/9 57.7 ST-02 (Tower Hill 69.9 (47.9-69.9) Farm, 5 mi S) Gross Beta 10/10 1.0 10/10 1.06 ST-04 (Jerry Sarno, 1.18 Sr-89 10/10 0.025 10/10 (0.35-1. 77) LLD 3.5 mi. SE) (0.62-1.77) Sr-90 10/10 0.005 10/10 LLD I-131 10/10 0.06 10/10 LLD Other Gamma 10/10 0.05-0.10 10/10 LLD (2) Same control TLDs as Inner Ring. All Control Nonroutine 'Locations Reriorts(cl 34/34 4.5 None (3.2-5.6) 11/11 12.7 None 2/2 (10.4-15.5) 54.6 None (52.8-56.4) 34/34(2) 4.5 None 11/11 (2) (3.2-5.6) 12.7 None 2/2(2) (10.4-15.5) 54.6 None (52.8-56.4) N/A None N/A None N/A None N/A None N/A None
Medium or Analyses Evaluated/ Pathway Saml!led Analyses Performed Sediment Gross Beta 11/11 (pCi/g dry) Sr-89 11/11 Sr-90 11/11 Cs-137 11/11 Other Gamma 11/11 Algae (pCi/g wet) Gross Beta Sr-89 Sr-90 Cs-137 Other Gamma Fish (pCi/g wet) Gross Beta 21/21 Sr-89 21/21 Sr-90 21/21 Other Gamma 21/21 Broadleaf Gross Beta Vegetation(d) 1-131 (pCi/g wet) Sr-89 Sr-90 Cs-137 Other Gamma Palisades Nuclear Plant, Van Buren County, Mi. Docket 50-255 Annual Radiological Environmental Operating Report January 1 to December 31, 1992 Table HP 10.4-2 Sample Data Summary Lower Limit All of Detection(a} Indicator Locations Location With Greatest Annual Mean 1.0 0.025 0.005 0.18 0.05-0.15 1.0 0.025 0.005 0.15 0.10-0.26 1.0 0.025 0.005 0.10-0.26 1.0 0.06 0.025 0.005 0.08 0.05-0.10 8/8 6.13 (3.8-8.49) 8/8 LLD 8/8 LLD 8/8 LLD 8/8 LLD No Samples Collected 11/11 2.23 (0.93-2.90) 11/11 LLD 11/11 LLD 11/11 LLD No Samples Collected ST-25 LLD LLD LLD LLD ST-01 LLD LLD LLD (South Haven, 5.5 mi. NNE) (Palisades Plant Site) 8.14 (7.78-8.49) 2.23 (0.93-2.90) All Control Locations 3/3 9.51 (4.64-12.06) 3/3 LLD 3/3 LLD
- 3/3 LLD 3/3 LLD 10/10 2.84 (1.57-3.81) 10/10 LLD 10/10 LLD 10/10 LLD Nonroutine Re!!orts (c}
None None None None None None None None None {a) Nominal Lower Limit of Detection (LLD) as defined in MASL-300 (Rev 0/73), pages D-06-01, 02 and 03; Palisades ODCM, Appendix A, Table E-3 and vendor analytical capabilities. (b) Mean and range based upon detectable measurements and/or vendor laboratory LLDs. (c) Nonroutine reported measurements are defined in the Palisades ODCM, Appendix A, Section IV.C. (d) Supplemental sample when milk is unavailable. ("e) Monthly TLD results are normalized for 30 days net; Quarterly TLD results are normalized for 91 days net. (f) Analysis not required for South Haven Municipal raw water.
Medium Air (pCi/m3) Lake Water (pCi/L) Drinking Water (pCi/L) Well Water (pCi/L) Milk (pCi/L) TLD (Gamma-mR) Inner Ring (site boundary) TLD (Gamma-mR) Outer Ring Palisades Nuclear Plant, Van Buren County, Mi. Docket 50-255 Annual Radiological Environmental Operating Report January 1 to December 31, 1992 Table HP 10.4-3 Greatest Mean Sampling Location Type of Analysis Location -1:!.i.9.h_ 0.052 Gross Beta ST-12 (Control-Dowagiac, 30 mi SSE) 0.016 1-131 Gross Alpha LLD Gross Beta LLD Tritium LLD Gross Beta LLD Tritium LLD Gross Beta ST-42 (Site Monitoring Well#l5) 7.6 3.3 Tritium LLD 1-131 LLD Sr-89 LLD Sr-90 ST-26 (F. Crnkovich, 7.5 mi NE) 6.3 2.2 Cs-137 LLD Other Gamma LLD TLD (Monthly) ST-11 (Control-Kalamazoo, 35 mi SSE) TLD (Quarterly) ST-35 (ENE Site Boundary) 5.5 3.2 14.2 13.1. TLD (Annual) ST-35 (ENE Site Boundary) TLD (Monthly) ST-02 (Tower Hi 11 Farm, 5 mi S) 7.0 4.3 TLD (Quarterly) ST-02 (Tower Hil 1 Farm, 5 mi S) 19.2 15.4 TLD (Annual) ST-02 (Tower Hi 11 Farm, 5 mi S) Mean 0.025 <0.07 <1.0 <4.0 <500.0 <4.0 <500.0 5.4 <500.0 <1.0 <5.0 3.7 <18.0 <15.0 4.8 13.6 59.0 5.6 17.2 69.9
Medium Crops (pCi/g wet) Sediment (pCi/g dry) Algae (pCi/g wet) Fish (pCi/g wet) Broad Leaf Veg (pCi/g wet) Palisades Nuclear Plant, Van Buren County, Mi. Docket 50-255 Annual Radiological Environmental Operating Report January 1 to December 31, 1992 Table HP 10.4-3 Greatest Mean Sampling Location Ty(,!e of Analysis Location -1li9h... --1.IDL Gross Beta ST-04 (Jerry Sarno, 3.5 mi SE)
- 1. 77 0.62 Sr-89 LLD Sr-90 LLD Cs-137 LLD I-131 LLD Other Gamma LLD Gross Beta ST-25 (South Haven, 5.5 mi NNE) 8.49 7.78 Sr-89 LLD Sr-90 LLD Other Gamma LLD Gross Beta No Samples Collected Sr-89 Sr-90 Co-60 Cs-137 Other Gamma Gross Beta ST-01 (Palisades Plant Site) 2.90 0.93 Sr-89 LLD Sr-90 LLD Other Gamma LLD Gross Beta No Samples Collected I-131 Sr-89 Sr-90 Other Gamma Mean 1.18
<0.025 <0.005 <0.08 <0.06 <0.05-0.10 8.14 <0.025 0.005 <0.05-0.15 2.23 <0.025 <0.005 <0.10-0.26
Enclosures A. Sample Collection Anomalies B. Palisades 1992 Land use Census C. Health Physics Procedure HP 10.10, "Palisades Radiological Environmental Program S~mple Collection and Shipment Procedure" {with sample locations, maps, etc). D. Palisades 1992 (Annual) Radiological Environmental Monitoring Program Data as provided by Teledyne Isotopes Midwest Laboratory, Northbrook, IL. E. Teledyne Isotopes Midwest Laboratory EPA Interlaboratory Comparison Program Results F. Data Graphs
- 1.
Palisades Air Particulate (gross beta) 1992 Trending and Palisades Air*Particulate (gross beta) Operational Comparison Graphs, 1968-1969 (pre-op) and 1987-1992.
- 2.
Palisades Lake Water/Drinking Water (gross beta) 1992 Trending and Palisades (gross beta) Operations Comparison Graphs, 1987-1992.
- 3.
Palisades Well Water (gross beta) 1992 Trending and Palisades Operational Comparison Graphs 1968-1969 {pre-op) and 1987-1992.
- 4.
Palisades Milk (Sr-90) 1992 Trending and Palisades Operational Comparison Graphs (Sr-90 and Cs-137); 1968-1969 (pre-op) and 1987-1992.
- 5.
Palisades TLD (gamma) 1992 Trending and Palisades Operational Comparison graphs (monthly, quarterly and annual); 1968-1969 (pre-op monthly) and 1987-1992.
- 6.
Palisades Sediment (gross beta) 1987-1992 Trending and Palisades Operational Comparison Graphs; 1987-1992.
- 7.
Palisades Fish (gross beta and Sr-90) Trending and Palisades Operational Comparison Graphs (gross beta, Sr-90 and Cs-137); 1968-1969 (pre-op, Sr-90 and Cs-137) and 1987-1992.
Enclosure A Sample Collection Anomalies Sample Type Affected Location Date Problem. Evaluation AP/I-131 2TH 12-27-92 Weelky air sample Loss of power to volume low - values pump location not included in statistical analysis AP/I-131 4JS 3-08-92 Filter paper very Filter not light - results not properly installed included in into filter holder statistical analysis AP/I-131 7SD 1-19-92 Filter paper very Filter not 1 i ght - results not
- properly installed included in into filter holder statistical.analysis AP/I-131 llKZ 8-19-92 Filter paper very Filter not 1 i ght -
results not properly installed included in into filter holder statistical analysis P/I-131 12DG 1-08-92 Weelky air sample Filter changed out volume low - values pre-matually not not included in enough sample statistical analysis volume TLD STll 5-30-92 May TLD missing May monthly TLD at time of collection lost - no TLD data available for month TLD ST33 6-28-92 June monthly TLD TLDs lost possibly and annual TLD due to high winds
- missing at time of no monthly TLD data
-co 11 ect ion available - annual TLD replaced TLD STIO 10-04-92 September monthly, TLDs vandalized, no ST24 quarterly, and annual monthly, quarterly TLD missing at time or annual TLD data of collection available. TLD ST33 1-03-93 Annual TLD missing Annual TLD lost - at time of collection no TLD data
- To KMHaas, Palisades From TLPopp, Palisades--rt-f='~
CONSUMERS POWER Date October 5, 1992 COMPANY Subject PALISADES PLANT - Internal 1992 LAND USE CENSUS Correspondence cc GASturm, Palisades TPNeal, Palisades TLP92*011 DCC:950/72*10*03/LP The attached tables and map are the results of the Palisades Land Use Census conducted by TLPopp and LDDine on August 27, 1992. Table 10.11-1 references the distance from Palisades to the nearest residence, garden (greater than 500 square feet}, beef/dairy cattle, and goat per meteorological sector. Table 10.11-2 identifies the locations of the nearest residence and garden; and of all beef/dairy cattle and goats within a five (5) mile radius of. Palisades per meteorological sector. Table 10.11-3 lists the critical receptor locations µsed in calculation of the offsite doses by the GASPAR computer program. An accompanying map illustrates Table 10.11-2. Both the Van Buren County Agricultural Extension Office and Consumers Power Company Southern Region - District Manager's Office (Kalamazoo} were contacted as required in Procedure HP 10.11. The Critical Receptor for goats changed from 3.80 miles to 2.50 miles in the ENE sector. The X/Q (sec/m3} subsequently changed from 6.9E-08 to l.3E-07 for this item. The Critical Receptor for a garden changed from the South sector at 0.50 miles to the NE sector at 0.90 miles. The X/Q subsequently changed from l.OE-06 to 7.3E-07 for this item. Tables 10.11-l and 10.11-3 are required to be up.dated in the ODCM as Tables 1.4 and l.4a respectively. Attached to this* report are the new revisions of Tables 1.4 and l.4a. If you have any questions, please contact me. Revised and Authorized _..;....W...;;.. 1~
- \\J_.~... "-
0................ --' .......s-_rs:......,..!.....__ __________ l a_* _--_G_-_'1_'-_ MDM~nnucci, HP Technical Supervisor Date
1992 PALISADES LAND USE CENSUS TABLE 10.11-1 Distance to the nearest residence, garden, dairy/beef cattle and goat in each sector. SECTOR RESIDENCE GARDEN BEEF CATTLE DAIRY COW GOAT N >5 mi >5 mi >5 mi >5 mi >5 mi NNE 1.1 mi 1.6 mi >5 mi >5 mi >5 mi NE .9 mi .9 mi >5 mi >5 mi >5 mi ENE
- 1. 3 mi 1.5 mi 4.0 mi 4.0 mi 2.5 mi E
1.0 mi
- 1. O mi 3.5 mi
>5 mi >5 mi ESE 1.0 mi 1.1 mi 3.1 mi
- 4. O mi
>5 mi SE 1.0 mi 1.0 mi 3.8 mi 4.3 mi >5 mi SSE .75 mi 1.5 mi >5 mi >5 mi >5 mi s .5 mi 1.5 mi >5 mi >5 mi >5 mi SSW . 75 mi
- 1. 5 mi
>5 mi >5 mi >5 mi
Sector NNE Ruggles Road NNE NE Blue Star Hwy ENE 24th Avenue, dead end 1992 PALISADES LAND USE CENSUS TABLE 10.11-2 Verification of Items Location Description L. Kern-State Park Manager 20th & Fire Lane 0, intersection (West side of road). L. Swetay, Route 3, Box 133, South Haven-(East side of hwy). Trailer-West 24th Avenue, dead end at sand dune. Item Residence Garden Residence Garden Residence ENE 76776 - 24th Avenue, NW on Garden 24th & 76th Ave intersection of 24th & 76th Ave ENE 72nd Street E 77th Street dead end ENE Cecil Hodge, 16971 72nd St 3/8 mile South of 16th Ave and 72nd St intersection (West side of 72nd St). 77th St - I mile North of 77th St and 28th Avenue intersection. 24th & M-140 intersection West side Cattle Residence Garden Goats Number/Comment I I I I 1 I 2-Dairy Cow 7-Dairy Cow I I 2
E 72nd Street ESE 77 I/2 Street. ESE ESE 34th Ave ESE 30th Ave ESE 69th Street SE 28th Ave. SE 34th Avenue SE 36th Avenue I992 PALISADES LAND USE CENSUS TABLE 10.Il-2 (Cont'd) C. Mims, 26200 72nd St intersection of 72nd St and 26th Ave {Northwest corner of intersection).
- 0. Ashley - Northwest corner of 77 I/2th St and 28th Ave intersection {28008)..
77th & 28th intersection {I/IO, mi West of) Herchy House, 72753 34th Ave Newell, 73419 30th Avenue Dairy Farm, 69th St, I/2 mile North of 69th St and 34th Avenue intersection (approximately I/2 mile outside of 5 mile limit zone). 77550 28th Ave. L. Burrows - I/2 mile East of 34th Ave and M-I40 intersection (South side of 34th Ave). G. Miller, Route I, Box 20, Covert - I/2 mile West of 36th Ave and 72nd St intersection (South side of 36th St). Cattle Residence Garden Cattle Cattle Cattle Residence Garden Cattle Cattle 2-Beef I I 25-Dairy Cow 3-Beef I5-Dairy Cows IO-Beef I I I5-Beef I-Dairy Cow
SSE 29th Avenue SSE 77 1/2 St SSE CR 376 s 29th Avenue s 32nd Avenue SSW 20th Avenue dead end SSW 32nd Avenue 1992 PALISADES LAND USE CENSUS TABLE 10.11-2 {Cont'd L. Burrows - Route 1, Box 167, Covert - Southwest corner of 29th Ave and Blue Star Hwy intersection. Charles Dunson residence half way between 30th and 32nd Ave (West side on 77 I/2th St). Marshall - Southwest corner of CR 376 and M-140 intersection (owner of cattle is J. Donald . leasing Marshall property - at edge of 5 mile limit zone). Residence - _Palisades Park; 3/4 mile West of 29th Ave. and Blue Star Hwy intersection (North side of 29th Ave). Northwest corner of 32nd Ave and Blue Star Hwy. R. James - 29th Ave, dead end, Palisades Park. Dead end of dirt road, 1/2 mile West from 32nd Ave and Blue Star Hwy intersection. Residence Garden Cattle Residence Garden Residence Garden I I 8-Beef 4-Goats I I I I
Sector SSE s NE ESE ENE ENE Note:
- Based on Distance Mil es 0.48 a.so
- 0. 90.
3.10 4.00 2.50 1992 PALISADES LAND USE CENSUS TABLE 10.11-3 Critical Receptor Items Location/Description Item Site Boundary N/A Residence, Palisades Park; Residence 3/4 mile West of 29th Avenue and Blue Star. intersection. L.Swetway, Rt 3, Box 133 Garden Blue Star Hwy, East side Newell, 73419 30th Ave Beef Covert *(South side of road) Cattle Cecil Hodge, 16971 72nd Dairy Street, 3/8 mile South of Cow 16th Avenue and 72nd Street intersection (West side of 72nd Street). 24th & M-140 intersection, Goat West side
- X/O ( sec/m3).
l.4E-06 l.OE-06 7.3E-07 7.4E-08 6.4E-08 l.3E-07 Palisades 5 year composite meteorological data, 1983-1987.
TABLE 1. 4 1992 PALISADES LAND USE CENSUS TABLE 10.11-1 Distance to the nearest residence, garden, dairy/beef cattle and goat in each sector. SECTOR RESIDENCE GARDEN N >5 mi >5 mi NNE 1.1 mi I. 6 mi NE .9 mi .9 mi ENE 1.3 mi 1.5 mi E
- 1. 0 mi I.O mi ESE I.O mi I. I mi SE I.O mi I.O mi SSE
.75 mi I.5 mi s .5 mi 1.5 mi SSW .75 mi 1.5 mi BEEF CATTLE >5 mi >5 mi >5 mi 4.0 mi
- 3. 5.mi 3.1 mi 3.8 mi
>5 mi >5 mi >5 mi 37 DAIRY COW >5 mi >5 mi >5 mi 4.0 mi >5 mi 4.0 mi 4.3 mi >5 mi >5 mi >5 mi GOAT >5 mi >5 mi >5 mi 2.5 mi >5 mi >5 mi >5 mi >5 mi >5 mi >5 mi Rev 7 10/05/92
Sector SSE s NE ESE ENE ENE Note:
- Based on Distance Mil es 0.48 0.50 0.90 3.10 4.00 2.50 TABLE l.4a 1992 PALISADES LAND USE CENSUS TABLE 10.11-3 Critical Receptor Items Location/Description Item Site Boundary N/A Residence, Palisades Park; Residence 3/4 mile West of 29th Avenue and Blue Star intersection.
L.Swetway, Rt 3, Box 133 Garden Blue St_ar Hwy, East side Newell, 73419 30th Ave Beef Covert (South side of road) Cattle Cecil Hodge, 16971 72nd Dairy Street, 3/8 mile South of Cow 16th Avenue and 72nd Street .intersection (West side o~ 72nd Street). 24th & M-140 intersection, Goat West side
- X/O ( sec/m3).
- 1. 4E-06 1.0E-06 7.3E-07 7.4E-08 6.4E-08 l.3E-07 Palisades 5 year composite meteorological data, 1983-1987.
38 Rev 7 10/05/92
FINAL MONTHLY PROGRESS REPORT ro CONSUMERS POWER COMPANY JACKSON, MICHIGAN ~TELEDYNE ISOTOPES MIDWEST LABORATOKY 700 LANDWEHR ROAD NORTHBROOIC. IUJNOlS 60062-2310 (700) 564-aTOO PAX C700l564-4517 RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM (REMP) FOR PALISADES NUCLEA.~ GENERATING PLANT PREPARED AND SUBMITTED BY TELEDYNE ISOTOPES MIDWEST LABORATORY PROJECT NO. 8022 Reporting Period: January-December, 1992 Reviewed and * ~/) I/ /J Approvedby: ._CL.!tu.~ L. G. u er General Manager Distribution: M: Mennucd (1 copy) I I ,,,.-------9305050189 930428 1 PDR ADOCK 05000255 R .PDR Date ,,2*,22 - 9 3
PALISADES TABLE OF CONTENTS Section List of Tables............................................................................................................. iii 1.0 IN"I'RODUCTION...................................................................................................... 1 20 LISTING OF MISSED SAMPLES............................................................................. 2 Appendices A Interlaboratory Comparison Program Results................................................ A-1 B Data Reporting Conventions............................................................................... B-1 ii
PALISADES LIST OF TABLES No. Page 1 Airborne Particulates and Iodine-131 Location 1ST................................................................................................................ 4 Location 2TH............................................................................................................... 5 Location 3HS............................................................................................................... 6 Location 4JS.................................................................................................................. 7 Location 5PR................................................................................................................ 8 Location 6RB............................................................................................................... 9 Location 750.............................................................................................................. 10 Location SSP............................................................................................................... 11 Location 9TP.............................................................................................................. 12 Location 10GR........................................................................................................... 13 Location 11¥..2............................................................................................................ 14 Location 12DG........................................................................................................... 15 2 Gamma Radiation, as Measured by TLDs, Monthly Exposure................................ 16 3 Gamma Radiation, as Measured by TLDs, Quarterly Exposure............................... 20 4 Gamma Radiation, as Measured by TLDs, Annual Exposure............................ :..... 21 5 Lake Water, Intake and Discharge.................................................................................. 22 6 Drinking Lake Water......................................................................................................... 24 7 Well Water.......................................................................................................................... 25 8 In-Plant Water.................................................................................................................... 37 9 Milk....................................................................................................................................... 41 10 Food Crops........................................................................................................................... 45 11 Fish........................................................................................................................................ 48 12 Algae...................................................................................................................................... 51 13 Bottom Sediments............................................................................................................. 52 14 Special Samples 14.1 Liquid Radwaste................................................................................................. 55 14.2 Stack Filters......................................................................................................... 59 14.3 NRC Split Samples............................................................................................ 60 14.4 Reactor Water..................................................................................................... 60 14.5 Steam Generator Slowdown........................................................................... 60 iii
PALISADES 1.0 INfRODUCTION The following constitutes the final Monthly Progress Report for the Radiological Environmental Monitoring Program conducted at the Palisades Nuclear Generating Plant, Covert, Michigan. Results of completed analyses are presented in the attached tables. Data obtained in the program are well within the ranges previously encountered in the program and to be expected in the environmental media sampled. For all gamma isotopic analyses, the spectrum is computer scanned from 80 to 2048 KeV. Specifically included are Mn-54, Fe-59, Co-58, Co-60, Zn-65, Zr-95, Nb-95, 1-131, Ba-La-140, Cs-134, and Cs-137. Naturally occurring gamma-emitters, such as K-40 and Ra daughters, are frequently detected but not listed here. Data listed as"<" are at the 4.66 sigma level, others are 2 sigma. Unless noted otherwise, the less than value ("<") reported under "Other Gammas" is for Co-60 and may be higher or lower for other radionuclides. All concentrations, except gross beta, are decay corrected to the time of collection. All samples were collected within the scheduled period unless noted otherwise in the Listing of Missed Samples. 1
PALISADES 20 LISTING OF MISSED SAMPLES Expected Collection Sample Type Location Date Reason Liquid Radwaste Palisades January Sample not collected. Liquid Radwaste Palisades February Sample not collected. TLD ST-11 May TLD not received. TLD Control-1 May TLD lost in the field. Liquid Radwaste Palisades May Sample not collected. Liquid Radwaste Palisades July Sample not collected. Liquid Radwaste Palisades August Sample not collected. Liquid Radwaste Palisades September Sample not collected. TLD ST-10 September TLD lost in the field. TLD ST-24 September TLD lost in the field. TLD ST-10 3rdQtr. TLD lost in the field. TLD ST-24 3rdQtr. TLD lost in the field. Liquid Radwaste Palisades October Sample not collected. TLD ST-10 Annual TLD lost in the field. TLD ST-24 Annual TLD lost in the field. TLD ST-33 Annual TLD lost in the field. NOfE: Page 3 is intentionally left out. 2
PALISADES Table 1. Airborne particulates and iodine-131 Collection: Weekly Units: pCi/m3 Location: lST-Palisades Date Volume Date Volume Collected (m3) Gross Beta 1-131 Collected (m3) Gross Beta 1-131 01-05-92 295 0.023+/-0.004 <0.028 07-05-92 275 0.016+/-0.003 <0.010 01-12-92 300 0.021+/-0.004 <0.037 07-12-92 278 0.019+/-0.004 <0.009 01-19-92 314 0.021+/-0.003 <0.025 07-19-92 280 0.014+/-0.003 <0.011 01-26-92 306 0.032+/-0.004 <0.034 07-26-92 283 0.013+/-0.003 <0.010 02-02-92 314 0.026+/-0.003 <0.033 08-02-92 278 0.015+/-0.003 <0.011 02-09-92 300 0.024+/-0.003 <0.033 08-09-92 278 0.014+/-0.002 <0.010 02-16-92 309 0.021+/-0.003 <0.035 08-16-92 278 0.013+/-0.003 <0.017 02-23-92 303 0.024+/-0.002 <0.035 08-23-92 280 0.019+/-0.003 <0.012 03-01-92 306 0.019+/-0.003 <0.035 08-30-92 295 0.014+/-0.003 <0.007 03-08-92 289 0.029+/-0.004 <0.039 09-06-92 278 0.021+/-0.003 <0.010 03-15-92 306 0.026+/-0.004 <0.030 09-13-92 280 0.015+/-0.003 <0.008 03-22-92 309 0.021+/-0.003 <0.031 09-20-92 283 . 0.025+/-0.004 <0.011 03-29-92 306 0.016+/-0.003 <0.027 09-27-92 286 0.017+/-0.004 <0.011 1st Qtr. mean +/- s.d. 0.023+/-0.004 <0.039 3rd Qtr. mean+/- s.d. 0.016+/-0.004 <0.017 04-05-92 295 0.014+/-0.003 <0.035 10-04-92 286 0.021+/-0.004 <0.021 04-12-92 297 0.017+/-0.002 <0.022 10-11-92 283 0.016+/-0.003 <0.011 04-19-92 300 0.013+/-0.003 <0.026 10-18-92 286 0.012+/-0.003 <0.013 04-26-92 297 0.013+/-0.003 <0.025 10-26-92 331 0.035+/-0.004 <0.008 05-03-92 297 0.023+/-0.004 <0.020 11-01-92 246 0.018+/-0.004 <0.011 05-10-92 292 0.018+/-0.003 <0.030 11-08-92 275 0.010+/-0.003 <0.023 05-17-92 289 0.024+/-0.003 <0.019 11-15-92 280 0.020+/-0.003 <0.010 05-24-92 292 0.014+/-0.003 <0.009 11-22-92 292 0.018+/-0.003 <0.016 05-31-92 300 0.012+/-0.003 <0.010 11-29-92 292 0.013+/-0.003 <0.015 06-07-92 283 0.017+/-0.004 <0.011 12-06-92 289 0.025+/-0.004 <0.011 06-14-92 278 0.012+/-0.003 <0.009 12-13-92 295 0.018+/-0.003 <0.015 06-21-92 286 0.012+/-0.003 <0.019 12-20-92 295 0.019+/-0.003 <0.011 06-28-92 286 0.014+/-0.002 <0.011 12-27-92 289 0.033+/-0.004 <0.010 2nd Qtr. mean+/- s.d. 0.016+/-0.004 <0.035 4th Qtr. mean +/- s.d. 0.020+/-0.007 <0.023 4
PALISADES Table 1. Airborne particulates and iodine-131 Collection: Weekly Units: pCi/m3 Location: 2TII - Coloma (5 miles SSE) Date Volume Date Volume Collected (m3) Gross Beta 1-131 Collected (m3) Gross Beta 1-131 01--05-92 272 0.027+/-0.004 <0.031 07--05-92 269 0.015+/-0.004 <0.011 01-12-92 286 0.025+/-0.004 <0.038 07-12-92 266 0.017+/-0.004 <0.010 01-19-92 136 0.022+/-0.006 <0.058 07-19-92 269 0.018+/-0.003 <0.012: 01-26-92 289 0.030+/-0.004 <0.036 07-26-92 Z78 0.010+/-0.003 <0.011 02--02-92 300 0.024+/-0.003 <0.035 08--02-92 272 0.014+/-0.003 <0.012 02--09-92 286 0.025+/-0.004 <0.035 08--09-92 269 0.015+/-0.002 <0.011 02-16-92 295 0.020+/-0.003 <0.037 08-16-92 266 0.010+/-0.003 <0.018. 02-23-92 289 0.024+/-0.003 <0.036 08-23-92 266 0.018+/-0.003 <0.013 03--01-92 295 0.019+/-0.003 <0.036 08-30-92 283 0.014+/-0.003 <0.007 03--08-92 283 0.030+/-0.004 <0.040 09--06-92 258 0.021+/-0.004 <0.011 03-15-92 292 0.023+/-0.004 <0.031 09-13-92 266 0.013+/-0.003 <0.009 03-22-92 295 0.023+/-0.004 <0.032 09-20-92 269 0.027+/-0.004 <0.012 03-29-92 286 0.016+/-0.003 <0.029 09-27-92 Z75 0.008+/-0.003 <0.012 1st Qtr. mean+/- s.d. 0.024+/-0.004 <0.058 3rd Qtr. mean +/- s.d. 0.015+/-0.005 <0.018 04--05-92 289 0.014+/-0.003 <0.035 10-04-92 272 0.024+/-0.004 <0.022 04-12-92 289 0.018+/-0.002 <0.023 10-11-92 280 0.017+/-0.003 <0.011 04-19-92 283 0.014+/-0.003 <0.027 10-18-92 283 0.016+/-0.003 <0.013 04-26-92 286 0.010+/-0.003 <0.026 10-26-92 329 0.034+/-0.004 <0.008 05--03-92 286 0.019+/-0.004 <0.020 11--01-92 238 0.013+/-0.004 <0.011 05-10-92 280 0.018+/-0.003 <0.031 11--08-92 283 0.007+/-0.002 <0.022 05-17-92 280 0.023+/-0.003 <0.020 11-15-92 289 0.013+/-0.003 <0.009 05-24-92 Z78 0.017+/-0.003 <0.009 11-22-92 292 0.014+/-0.003 <0.016 05-31-92 283 0.022+/-0.003 <0.010 11-29-92 289 0.014+/-0.002 <0.015 06--07-92 Z78 0.016+/-0.004 <0.012 12--06-92 297 0.027+/-0.004 <0.011 06-14-92 266 0.014+/-0.003 <0.009 12-13-92 295 0.015+/-0.003 <0.015 06-21-92 258 0.010+/-0.003 <0.021 12-20-92 292 0.017+/-0.003 <0.011 06-28-92 269 0.012+/-0.002 <0.012 12-27-92 31a 0.035+/-0.024 <0.09Qb 2nd Qtr.. mean +/- s.d. 0.016+/-0.004 <0.035 4th Qtr. mean +/- s.d. 0.019+/-0.009 <0.022 a Low volume due to no electricity at pump. b LLD for 1-131 not met due to low volume; result not uncluded in mean +/- s.d. calculation. 5
PALISADES Table 1. Airborne particulates and fodine-131 Collection: Weekly Units: pCi/m3 Location: 3HS-Covert (5 miles SE) Date Volume Date Volume Collected (m3) Gross Beta 1-131 Collected (m3) Gross Beta 1-131 01-05-92 295 0.024+/-0.004 <0.028 07-05-92 275 0.015+/-0.003 <0.010 01-12-92 303 0.018+/-0.003 <0.036 07-12-92 275 0.012+/-0.003 <0.010 01-19-92 314 0.022+/-0.003 <0.025 07-19-92 275 0.010+/--0.003 <0.012 01-26-92 312 0.028+/-0.004 <0.033 07-26-92 278 0.010+/--0.003 <0.011 02-02-92 317 0.025+/-0.003 <0.033 08-02-92 27'2 0.014+/-0.003 <0.012 02-09-92 306 0.025+/-0.003 <0.032 08-09-92 275 0.020+/--0.003 <0.010 02-16-92 283 0.019+/-0.003 <0.039 08-16-92 275 0.013+/-0.003 <0.017 02-23-92 309 0.021+/-0.002 <0.034 08-23-92 275 0.020+/--0.003 <0.012 03-01-92 314 0.019+/-0.003 <0.034 08-30-92 289 0.016+/-0.003 <0.007 03-08-92 300 0.026+/-0.003 <0.038 09-06-92 266 0.026+/-0.004 <0.010 03-15-92 312 0.021+/-0.003 <0.029 09-13-92 275 0.015+/-0.003 <0.008 03-22-92 314 0.016+/-0.003 <0.03 09-20-92 278 0.023+/-0.004 <0.011 03-29-92 303 0.016+/-0.003 <0.028 09-27-92 2.80 0.010+/--0.003 <0.012 1st Qtr. mean +/- s.d. 0.022+/-0.004 <0.039 3rd Qtr. mean +/- s.d. 0.016+/-0.005 <0.017 04-05-92 306 0.016+/-0.003 <0.033 10-04-92 278 0.025+/-0.004 <0.022 04-12-92 303 0.016+/-0.002 <0.022 10-11-92 286 0.017+/-0.003 <0.011 04-19-92 300 0.017+/-0.003 <0.026 10-18-92 283 0.015+/-0.003 <0.013 04-26-92 300 0.010+/--0.003 <0.025 10-26-92 331 0.035+/-0.004 <0.008 05-03-92 300 0.020+/--0.004 <0.019 11-01-92 241 0.019+/-0.004 <0.011 05-10-92 295 0.019+/-0.003 <0.029 11-08-92 286 0.010+/--0.003 <0.002 05-17-92 295 0.023+/-0.003 <0.019 11-15-92 286 0.022+/-{).003 <0.009 05-24-92 292 0.014+/-0.003 <0.009 11-22-92 289 0.018+/-0.003 <0.016 05-31-92 300 0.016+/-0.003 <0.010 11-29-92 292 0.012+/-0.003 <0.015 06-07-92 283 0.016+/-0.003 <0.011 12-06-92 297 0.029+/-0.004 <0.011 06-14-92 269 0.015+/-0.003 <0.009 12-13-92 297 0.016+/-0.003 <0.015 06-21-92 275 0.010+/--0.003 <0.020 12-20-92 295 0.019+/-0.003 <0.011 06-28-92 Z75 0.014+/-0.002 <0.012 12-27-92 297 0.038+/-0.004 <0.009 2nd Qtr. mean+/- s.d. 0.016+/-0.004 <0.033 4th Qtr. mean +/- s.4. 0.021+/-0.008 <0.022 6
Table 1. PALISADES Airborne particulates and iodine-131 Collection: Weekly Units: pCi/m3 Location: 4JS - Covert (3.5 miles ESE) Date Volume Date Volume Collected (m 3) Gross Beta I-131 Collected (m3) Gross Beta 01-05-92 'Z12 0.026+/-0.004 <0.031 07-05-92 263 0.019+/-0.004 01-12-92 280 0.027+/-0.004 <0.039 07-12-92 266 0.018+/-0.004 01-19-92 286 0.020+/--0.003 <0.028 07-19-92 272 0.004+/-0.003 01-26-92 280 0.022+/--0.003 <0.037 07-26-92 272 0.012+/-0.003 02-02-92 '197 0.025+/-0.004 <0.035 08-02-92 263 0.016+/--0.004 02-09-92 283 0.030+/-0.004 <0.035 08-09-92 269 0.016+/--0.002 02-16-92 292 0.019+/--0.003 <0.038 08-16-92 263 0.014+/--0.003 02-23-92 286 0.024+/--0.003 <0.037 08-23-92 266 0.018+/-0.003 03-01-92 295 0.021+/-0.003 <0.036 08-30-92 278 0.016+/--0.003 03-08-92 280 0.006+/-0.002a <0.040 09-06-92 249 0.027+/-0.004 03-15-92 289 0.024+/-0.004 <0.032 09-13-92 263 0.011+/-0.003 03-22-92 292 0.022+/--0.004 <0.032 09-20-92 272 0.027+/-0.004 03-29-92 286 0.018+/-0.003 <0.029 09-27-92 269 0.014+/--0.004 1st Qtr. mean +/- s.d. 0.022+/-0.006 <0.040 3rd Qtr. mean +/- s.d. 0.016+/--0.006 04-05-92 283 0.012+/-0.003 <0.036 10-04-92 272 0.019+/-0.004 04-12-92 283 0.021+/-0.002 <0.023 10-11-921 269 0.018+/-0.003 04-19-92 283 0.016+/-0.003 <0.027 10-18-92 272 0.019+/-0.003 04-26-92 283 0.011+/-0.003 <0.026 10-26-92 320 0.039+/-0.004 05-03-92 278 0.023+/-0.004 <0.021 11-01-92 232 0.021+/-0.004 05-10-92 283 0.016+/-0.003 <0.030 11-08-92 269 0.009+/-0.003 05-17-92 275 0.020+/--0.003 <0.020 11-15-92 272 0.022+/-0.003 05-24-92 275 0.014+/-0.003 <0.009 11-22-92 272 0.018+/-0.004 05-31-92 283 0.018+/-0.003 <0.010 11-29-92 275 0.014+/-0.002 06-07-92 269 0.019+/--0.004 <0.012 12-06-92 269 0.029+/-0.004 06-14-92 272 0.022+/-0.004 <0.009 12-13-92 278 0.021+/-0.003 06-21-92 252 0.011+/-0.003 <0.021 12-20-92 278 0.019+/-0.003 06-28-92 'Z12 0.014+/-0.002 <0.012 12-27-92 275 0.038+/-0.004 2nd Qtr. mean +/- s.d. 0.017+/-0.004 <0.036 4th Qtr. mean +/- s.d. 0.022+/-0.009 a Filter light. 7 1-131 <0.011 <0.010 <0.012 <0.011 <0.012 <0.0fl <0.018 <0.013 <0.007 <0.011 <0.009 <0.012 <0.012 <0.018 <0.022 <0.012 <0.014 <0.008 <0.011 <0.023 <0.010 <0.017 <0.016 <0.012 <0.016 <0.011 <0.010 <0.023
PALISADES Table 1. Airborne particulates and iodine-131 Collection: Weekly Units: pCi/m3 Location: SPR - Covert (3 miles E) Date Volume Date Volume Collected (m3) Gross Beta 1-131 Collected (m3) Gross Beta I-131 01-05-92 280 0.028+/-0.004 <0.030 07-05-92 261 0.015+/-0.003 <0.011 01-12-92 289 0.025+/-0.004 <0.038 07-12-92 263 0.021+/-0.004 <0.010 01-19-92 '297 0.021+/-0.003 <0.027 07-19-92 266 0.012+/-0.003 <0.012 01-26-92 295 0.032+/-0.004 <0.035 07-26-92 269 0.016+/-0.004 <0.011 02-02-92 303 0.025+/-0.003 <0.035 08-02-92 263 0.017+/-0.004 <0.012 02-09-92 292 0.028+/-0.004 <0.034 08-09-92 261 0.017+/-0.003 <0.011 02-16-92 '297 0.018+/-0.003 <0.037 08-16-92 263 0.014+/-0.003 <0.018 02-23-92 280 0.018+/-0.002 <0.037 08-23-92 263 0.019+/-0.004 <0.013 03-01-92 300 0.020+/-0.003 <0.035 08-30-92 283 0.015+/-0.003 <0.009 03-08-92 Z75 0.024+/-0.004 <0.041 09-06-92 249 0.024+/-0.004 <0.011 03-15-92 295 0.025+/-0.004 <0.031 09-13-92 261 0.012+/-0.003 <0.009 03-22-92 '297 0.021+/-0.004 <0.032 09-20-92 266 0.022+/-0.004 <0.012 03-29-92 292 0.018+/-0.003 <0.029 09-27-92 266 0.014+/-0.004 <0.022 1st Qtr. mean+/- s.d. 0.023+/-0.004 <0.041 3rd Qtr. mean +/- s.d. 0.017+/-0.004 <0.022 04-05-92 289 0.011+/-0.003 <0.035 10-04-92 266 0.024+/-0.004 <0.023 04-12-92 286 0.018+/-0.002 <0.023 10-11-92 266 0.015+/-0.003 <0.012. 04-19-92 286 0.015+/-0.003 <0.027 10-18-92 269 0.015+/-0.003 <0.014 04-26-92 286 0.011+/-0.003 <0.026 10-26-92 314 0.033+/-0.004 <0.008 05-03-92 283 0.022+/-0.004 <0.021 11-01-92 229 0.018+/-0.004 <0.011 05-10-92 286 0.017+/-0.003 <0.030 11-08-92 263 0.010+/-0.003 <0.024 05-17-92 280 0.023+/-0.003 <0.020 11-15-92 266 0.018+/-0.003 <0.010 05-24-92 278 0.015+/-0.003 <0.009 11-22-92 278 0.016+/-0.003 <0.017 05-31-92 286 0.017+/-0.003 <0.010 11-29-92 278 0.012+/-0.002 <0.016 06-07-92 272. 0.017+/-0.004 <0.012 12-06-92 275 0.031+/-0.004 <0.012 06-14-92 269 0.018+/-0.003 <0.009 12-13-92 280 0.018+/-0.003 <0.016 06-21-92 249 0.009+/-0.003 <0.022 12-20-92 283 0.017+/-0.003 <0.011 06-28-92 272. 0.014+/-0.002 <0.012 12-27-92 278 0.036+/-0.004 <0.010 2nd Qtr. mean +/- s.d. 0.016+/-0.004 <0.035 4th Qtr. mean +/- s.d. 0.020+/-0.008 <0.024 8
- PALISADES Table 1.
Airborne particulates and iodine-131 Collection: Weekly Units: pCi/m3 Location: 6RB - South Haven (4.75 mi NE) Date Volume Date Volume Collected (m3) Gross Beta 1-131 Collected (m3) Gross Beta 1-131 01--05-92 283 0.026+/-0.004 <0.030 07--05-92 263 0.015+/-0.004 <0.011 01-12-92 286 0.021+/-0.004 <0.038 07-12-92 269 0.014+/-0.003 <0.018 01-19-92 295 0.021+/-0.003 <0.027 07-19-92 272 0.016+/-0.003 <0.012* 01-26-92 297 0.031+/-0.004 <0.035 07-26-92 272 0.013+/-0.003 <0.018 02-02-92 303 0.023+/-0.003 <0.035 08-02-92 269 0.013+/-0.003 <0.012 02--09-92 289 0.020+/-0.003 <0.034 08-09-92 269 0.014+/-0.002 <0.012 02-16-92 295 0.022+/-0.003 <0.037 08-16-92 269 0.014+/-0.003 <0.018 02-23-92 283 0.025+/-0.003 <0.037 08-23-92 275 0.018+/-0.003 <0.012 03--01-92 289 0.021+/-0.004 <0.037 08-30-92 289 0.017+/-0.003 <0.009 03--08-92 269 0.029+/-0.004 <0.042 09-06-92 255 0.022+/-0.004 <0.022 03-15-92 280 0.027+/-0.004 <0.033 09-13-92 278 0.006+/-0.003 <0.019 03-22-92 283 0.021+/-0.004 <0.033 09-20-92 275 0.027+/-0.004 <0.011 03-29-92 278 0.015+/-0.003 <0.030 09-27-92 278 0.014+/-0.004 <0.021
- 1st Qtr. mean +/- s.d.
0.023+/-0.004 <0.042 3rd Qtr; mean +/- s.d. 0.016+/-0.005 <0.022 04-05-92 269 0.012+/-0.004 <0.038 10-04-92 7@ 0.015+/-0.010 <0.049 04-12-92 272 0.017+/-0.002 <0.024 10-11-92 229 0.022+/-0.004 <0.014 04-19-92 283 0.016+/-0.003 <0.027 10-18-92 286 0.018+/-0.003 <0.013 04-26-92 286 0.010+/-0.003 <0.026 10-26-92 3.31 0.034+/-0.004 <0.008 05--03-92 283 0.022+/-0.004 <0.021 11--01-92 244 0.016+/-0.004 <0.011 05-10-92 283 0.017+/-0.003 <0.030 11--08-92 269 0.009+/-0.003 <0.025 05-17-92 286 0.019+/-0.003 <0.019 11-15-92 286 0.016+/-0.003 <0.009 05-24-92 283 0.015+/-0.003 <0.009 11-22-92 289 0.021+/-0.004 <0.016 05-31-92 289 0.018+/-0.003 <0.010 11-29-92 295 0.012+/-0.002 <0.015 06--07-92 272 0.012+/-0.003 <0.012 12--06-92 289 0.025+/-0.004 <0.012 06-14-92 275 0.019+/-0.003 <0.009 12-13-92 295 0.018+/-0.003 <0.010 06-21-92 244 0.009+/-0.003 <0.022 12-20-92 292 0.020+/-0.003 <0.011 06-28-92 275 0.012+/-0.002 <0.012 12-27-92 278 0.036+/-0.004 <0.010 2nd Qtr. mean +/- s.d. 0.015+/-0.004 <0.038 4th Qtr. mean +/- s.d. 0.020+/-0.008 <0.049 a Low volume due to sample pump failure. 9
PALISADES Table 1. Airborne particulates and iodine-131 Collection: Weekly Units: pCi/m3 Location: 750 - South Haven (7.5 miles NNE) Date Volume Date Volume Collected (m3) Gross Beta 1-131 Collected (m3) Gross Beta 1-131 01-05-92 178 0.028+/--0.005 <0.047 07-05-92 261 0.01 li-0.003 <0.009 01-12-92 255 0.027+/--0.004 <0.043 07-12-92 263 0.020+/-0.004 <0.018 01-19-92 278 <O.oo4a <0.028 07-19-92 261 0.01 li-0.003 <0.012 01-26-92 266 0.031+/--0.004 <0.039 07-26-92 269 0.014+/-0.003 <0.018 02-02-92 269 0.026+/--0.004 <0.039 0~2-92 263 0.012+/--0.003 <0.012 02-09-92 255 0.027+/--0.004 <0.039 0~-92 263 0.012+/--0.002 <0.012 02-16-92 249 0.017+/-0.004 <0.044 08-16-92 263 0.014+/-0.003 <0.005 02-23-92 269 0.024+/-0.003 <0.039 08-23-92 263 0.015+/--0.003 <0.023 03-01-92 286 0.023+/--0.004 <0.037 08-30-92 283 0.014+/-0.003 <0.009 03-08-92 263 0.029+/-0.004 <0.043 09-06-92 249 0.023+/--0.004 <0.023 03-15-92 278 0.024+/-0.004 <0.033 09-13-92 266 0.015+/--0.003 <0.020 03-22-92 278 0.018+/--0.004 <0.034 09-20-92 269 0.023+/--0.004 <0.012 03-29-92 278 0.017+/--0.003 <0.030 09-27-92 269 0.014+/-0.004 <0.022 1st Qtr. mean +/- s.d. 0.024+/-0.005 <0.047 3rd Qtr. mean +/- s.d. 0.015+/--0.004 <0.023 04-05-92 278 0.013+/--0.004 <0.037 10-04-92 275 0.020+/-0.004 <0.014 04-12-92 283 0.018+/--0.002 <0.023 10-11-92 272 0.017+/--0.003 <0.012 04-19-92 275 0.017+/--0.004 <0.028 10-18-92 280 0.016+/--0.003 <0.013 04-26-92 278 0.01 li-0.003 <0.027 10-26-92 323 0.031+/--0.004 <0.008 05-03-92 278 0.021+/--0.004 <0.021 11-01-92 235 0.020+/-0.004 <0.011 05-10-92 278 0.017+/--0.003 <0.031 11-08-92 275 0.007+/--0.003 <0.024 05-17-92 275 0.023+/--0.003 <0.020 11-15-92 283 0.020+/-0.003 <0.017 05-24-92 278 0.018+/--0.003 <0.009 11-22-92 289 0.016+/--0.003 <0.007 05-31-92 286 0.014+/-0.003 <0.010 11-29-92 283 0.013+/--0.002 <0.009 06-07-92 272 0.016+/--0.004 <0.012 12-06-92 283 0.026+/--0.004 <0.012 06-14-92 269 0.020+/-0.003 <0.009 12-13-92 283 0.019+/-0.003 <0.010 06-21-92 258 0.013+/--0.003 <0.021 12-20-92 289 0.016+/--0.003 <0.011 06-28-92 272 0.013+/--0.002 <0.012 12-27-92 283 0.037+/--0.004 <0.010 2nd Qtr. mean+/- s.d. 0.016+/--0.004 <0.037 4th Qtr. mean +/- s.d. 0.020+/-0.008 <0.024 a Filter improperly installed. 10
PALISADES Table 1. Airborne particulates and iodine-131 Collection: Weekly Units: pCi/m3 Location: 8SP - State Park (1 mile N) Date Volume Date Volume Collected (m3) Gross Beta I-131 Collected (m3) Gross Beta I-131 01-05-92 286 0.022+/-0.CXl4 <0.029 07-05-92 263 0.020+/-0.004 <0.009 01-12-92 289 0.023+/-0.004 <0.038 07-12-92 263 0.020+/-0.004 <0.018 01-19-92 306 0.017+/-0.003 <0.026 07-19-92 266 0.012+/-0.003 <0.012 *. 01-26-92 300 0.030+/-0.004 <0.035 07-26-92 272 0.012+/-0.003 <0.018 02-02-92 309 0.026+/-0.003 <0.034 o~.:.92 263 0.014+/-0.004 <0.012 02-09-92 295 0.026+/-0.004 <0.034 08-09-92 263 0.016+/-0.002 <0.012 02-16-92 303 0.018+/-0.003 <0.036 08-16-92 263 0.017+/-0.004 <0.005 02-23-92 297 0.024+/-0.002 <0.035 08-23-92 266 0.020+/-0.004 <0.023 03-01-92 309 0.024+/-0.003 <0.034 08-30-92 283 0.016+/-0.003 <0.009 03-08-92 283 0.026+/-0.004 <0.040 09-06-92 252 0.026+/-0.004 <0.023 03-15-92 303 0.025+/-0.004 <0.030 09-13-92 275 0.014+/-0.003 <0.019 03-22-92 303 0.020+/-0.003 <0.031 09-20-92 258 0.025+/-0.004 <0.012 03-29-92 300 0.017+/-0.003 <0.028 09-27-92 269 0.011+/-0.004 <0.022 1st Qtr. mean +/- s.d. 0.023+/-0.004 <0.040 3rd Qtr. mean +/- s.d. 0.017+/-0.005 <0.023 04-05-92 292 0.011+/-0.003 <0.035 10-04-92 269 0.027+/-0.004 <0.014 04-12-92 295 0.017+/-0.002 <0.022 10-11-92 266 0.016+/-0.003 <0.012 04-19-92 297 0.014+/-0.003 <0.026 10-18-92 343 0.012+/-0.003 <0.011 04-26-92 292 0.012+/-0.003 <0.026 10-26-92 326a 0.039+/-0.004 <0.008 05-03-92 292 0.023+/-0.004 <0.020 11-01-92 238 0.018+/-0.004 <0.011 05-10-92 289 0.016+/-0.003 <0.030 11-08-92 272 0.009+/-0.003 <0.025 05-17-92 275 0.021+/-0.003 <0.020 11-15-92 283 0.020+/-0.003 . <0.017 05-24-92 278 0.017+/-0.003 <0.009 11-22-92 286 0.020+/-0.004 <0.007 05-31-92 286 0.018+/-0.003 <0.010 11-29-92 289 0.013+/-0.002 <0.009 06-07-92 269 0.016+/-0.004 <0.012 12-06-92 286 0.027+/-0.004 <0.012 06-14-92 272 0.017+/-0.003 <0.009 12-13-92 289 0.015+/-0.003 <0.010 06-21-92 241 0.009+/-0.003 <0.022 12-20-92 295 0.017+/-0.003 <0.011 06-28-92 269 0.014+/-0.002 <0.012 12-27-92 289 0.038+/-0.004 <0.010 2nd Qtr. mean +/- s.d. 0.016+/-0.004 <0.035 4th Qtr. mean +/- s.d. 0.021+/-0.009 <0.025 a Collection sheet data in error; corrected meter reading. 11
PALISADES Table 1. Airborne particulates and iodine-131 Collection: Weekly Units: pCi/m3 Location: 9TP-Covert Township Park (1.5 miles S) Date Volume Date Volume Collected (m3) Gross Beta I-131 Collected (m3) Gross Beta I-131 01-05-92 286 0.030+/-0.004 <0.029 07-05-92 278 0.017+/-0.004 <0.008 01-12-92 295 0.023+/-0.004 <0.037 07-12-92 280 0.018+/-0.003 <0.017 01-19-92. 303 0.020+/-0.003 <0.026 07-19-92 280b 0.015+/-0.003 <0.011 01-26-92 300 0.031+/-0.004 <0.035 07-26-92 283 0.012+/-0.003 <0.017 02-02-92 312 0.028+/-0.004 <0.034 08-02-92 278 0.017+/-0.004 <0.011 02-09-92 297 0.024+/-0.003 <0.033 08-09-92 275 0.014+/-0.002 <0.011 02-16-92 303 0.022+/-0.003 <0.036 08-16-92 278 0.013+/-0.003 <0.005 02-23-92 300 0.024+/-0.002 <0.035 08-23-92 280 0.020+/-0.003 <0.022 03-01-92 312 0.020+/-0.003 <0.034 08-30-92 295 0.015+/-0.003 <0.008 03-08-92 286 0.027+/-0.004 <0.040 09-06-92 266 0.027+/-0.004 <0.022 03-15-92 297 0.016+/-0.003 <0.031 09-13-92 280 0.012+/-0.003 <0.019 03-22-92 306 0.020+/-0.003 <0.031 09-20-92 283 0.027+/-0.004 <0.011 03-29-92 306 0.015+/-0.003 <0.027 09-27-92 286 0.012+/-0.003 <0.021 1st Qtr. mean +/- s.d. 0.023+/-0.005 <0.040 3rd Qtr. mean +/- s.d. 0.017+/-0.005 <0.022 04-05-92 292 0.011+/-0.003 <0.035 10-04-92 289 0.024+/-0.004 <0.013 04-12-92 300 0.016+/-0.002 <0.022 10-11-92 283 0.018+/-0.003 <0.011 04-19-92 300 0.015+/-0.003 <0.026 10-18-92 286 0.015+/-0.003 <0.013 04-26-92 297 0.010+/-0.003 <0.025 10-26-92 337 0.034+/-0.004 <0.008 05-03-92 '197 0.022+/-0.004 <0.020 11-01-92 246 0.015+/-0.004 <0.011 05-10-92 292 0.019+/-0.003 <0.030 11-08-92 280 0.008+/-0.003 <0.024 05-17-92 292 0.022+/-0.003 <0.019 11-09-92 292 0.024+/-0.003 <0.016 05-24-92 292 0.019+/-0.003 <0.009 11-22-92 292 0.021+/-0.004 <0.007 05-31-92 303 0.014+/-0.003 <0.009 11-29-92 300 0.011+/-0.002 <0.008 06-07-92 283 0.014+/-0.003 <0.011 12-06-92 289 0.025+/-0.004 <0.012 06-14-92 278 0.015+/-0.003 <0.009 12-13-92 300 0.016+/-0.003 <0.009 06-21-92 17oa 0.010+/-0.005 <0.032 12-20-92 297 0.022+/-0.003 <0.011 06-28-92 289 0.013+/-0.002 <0.011 12-27-92 ~ 0.005+/-0.002 <0.009 2nd Qtr. mean +/- s.d. 0.015+/-0.004 <0.035 4th Qtr. mean +/- s.d. 0.018+/-0.008 <<0.024 a 5 day collection; power out for two days. 12
PALISADES Table 1. Airborne particulates and iodine-131 Collection: Weekly Units: pCi/m3 Location: lOGR-Grand Rapids (55 mi NNE) Date Volume Date Volume Collected (m3) Gross Beta 1-131 Collected (m3) Gross Beta 1-131 01-08-92 246 0.023+/-0.004 <0.010 07-08-92 280 0.012+/-0.003 <0.012 01-15-92 289 0.024+/-0.003 <0.054 07-15-92 283 0.010+/-0.003 <0.015 01-22-92 295 0.025+/-0.004 <0.045 07-22-92 278 0.016+/-0.003 <0.0ll 01-29-92 292 0.018+/-0.003 <0.049 07-29-92 272 0.018+/-0.003 <0.016 02-05-92 289 0.024+/-0.003 <0.047 08-05-92 278 0.014+/-0.004 <0.014. 02-12-92 295 0.017+/-0.003 <0.051 08-12-92 283 0.016+/-0.004 <0.006 02-19-92 289 0.022+/-0.003 <0.046 08-19-92 283 0.017+/-0.003 <0.029 02-26-92 286 0.014+/-0.003 <0.033 08-26-92 272 0.020+/-0.004 <0.026 03-04-92 286 0.020+/-0.003 <0.047 09-02-92 275 0.015+/-0.003 <0.013 03-11-92 286 0.015+/-0.003 <0.044 09-09-92 272 0.012+/-0.004 <0.015 03-18-92 289 0.019+/-0.003 <0.034 09-16-92 272 0.022+/-0.004 <0.011 03-25-92 289 0.018+/-0.004 <0.038 09-23-92 269 0.016+/-0.004 <0.011 04-01-92 280 0.014+/-0.003 <0.053 09-30-92 280 0.016+/-0.003 <0.022 1st Qtr. mean +/- s.d. 0.019+/-0.004 <0.053 3rd Qtr. mean +/- s.d. 0.016+/-0.003 <0.029 04-08-92 280 0.016+/-0.003 <0.043 10-07-92 275 0.020+/-0.004 <0.017 04-15-92 201 0.023+/-0.004 <0.062 10-14-92 283 0.017+/-0.003 <0.017 04-22-92 280 0.006+/-0.003 <0.034 10-21-92 275 0.017+/-0.003 <0.015 04-29-92 289 0.010+/-0.003 <0.028 10-28-92 278 0.025+/-0.004 <0.031 05-06-92 283 0.016+/-0.003 <0.042 11-04-92 280 0.009+/-0.003 <0.014 05-13-92 286 0.017+/-0.003 <0.028 11-11-92 280 0.014+/-0.003 <0.024 05-20-92 286 0.017+/-0.003 <0.012 11-18-92 289 0.017+/-0.003 <0.009 05-27-92 289 0.020+/-0.003 <0.013 11-25-92 283 0.010+/-0.003 <0.013 06-04-92 323 0.018+/-0.003 <0.022 12-02-92 286 0.028+/-0.004 <0.019 06-10-92 238 0.016+/-0.004 <0.014 12-09-92 '197 0.023+/-0.003 <0.013 06-17-92 269 0.023+/-0.004 <0.015 12-16-92 286 0.012+/-0.003 <0.011 06-24-92 280 0.016+/-0.003 <0.011 12-23-92 283 0.035+/-0.004 <0.014 07-01-92 278 0.018+/-0.004 <0.011 12-30-92 283 0.018+/-0.003 <0.015 2nd Qtr. mean +/- s.d. 0.017+/-0.005 <0.062 4th Qtr. mean +/- s.d. 0.019+/-0.007 <0.024 13
PALISADES Table 1. Airborne particulates and iodine-131 Collection: Weekly Units: pCi/m3 Location: 11 I<Z - Kalamazoo (35 miles E) Date Volume Date Volume Collected (m3) Gross Beta I-131 Collected (m3) Gross Beta I-131 '01-08-92 255 0.031+/-0.004 <0.010 07-08-92 278 0.018+/-0.003 <0.012 01-16-92 337 0.024+/-0.003 <0.047 07-15-92 278 0.016+/-0.004 <0.015 01-22-92 266 0.031+/-0.004 <0.050 07-22-92 275 0.018+/-0.003 <0.011 01-29-92 292 0.029+/-0.004 <0.049 07-29-92 289 0.016+/-0.003 <0.015 02-05-92 . 300 0.026+/-0.003 <0.046 08-06-92 306 0.013+/-0.003 <0.013 02-12-92 309 0.019+/-0.003 <0.049 08-12-92 241 0.019+/-0.004 <0.008 02-19-92 295 0.020+/-0.003 <0.045 08-19-92 343 0.005+/-0.002a <0.024 02-26-92 300 0.021+/-0.003 <0.032 08-26-92 218 0.028+/-0.005 <d).033 03-04-92 295 0.025+/-0.004 <0.045 o9-02-92 278 0.018+/-0.003 . <0.013 t-" 03-11-92 278 0.015+/-0.003 <0.046 09-09-92 280 0.015+/-0.004 <0.014 03-20-92 399 0.023+/-0.003 <0.006 09-18-92 346 0.017+/-0.003 <0.008 "*I 03-25-92 221 0.024+/-0.004 <0.050 09-23-92 204 0.017+/-0.004 <0.015 04-01-92 286 0.015+/-0.003 <0.052 10-01-92 331 0.016+/-0.003 <0.019 1st Qtr. mean +/- s.d. 0.023+/-0.005 <0.052 3rd Qtr. mean +/- s.d. 0.017+/-0.005 <0.033 04-09-92 340 0.016+/-0.003 <0.035 10-07-92 252 0.026+/-0.004 <0.018 04-15-92 258 0.022+/-0.004 <0.048 10-14-92 292 0.021+/-0.002 <0.017 04-22-92 286 0.011+/-0.003 <0.033 10-21-92 303 0.021+/-0.003 <0.014 04-29-92 297 0.017+/-0.003 <0.028 10-28-92 286 0.039+/-0.004 <0.030 05-06-92 286 0.017+/-0.003 <0.042 11-04-92 300 0.018+/-0.003 <0.013 05-14-92 323 0.014+/-0.003 <0.025 11-11-92 348 0.014+/-0.003 <0.019 05-21-92 289 0.021+/-0.003 <0.012 11-18-92 252 0.019+/-0.004 <0.011 05-27-92 238 0.017+/-0.004 <0.016 11-25-92 303 0.014+/-0.003 <0.012 06-08-92 479 . 0.007+/-0.002 <0.006 12-02:.92 295 0.009+/-0.002 <0.018 06-10-92 79 0.028+/-0.009 <0.042 12-09-92 323 0.020+/-0.003 <0.012 06-17-92 278 0.025+/-0.004 <0.014 12-16-92 295 0.016+/-0.003. <0.011 06-23-92 246 0.017+/-0.004 <0.012 12-23-92 300 0.036+/-0.004 <0.013 07-01-92 320 0.021+/-0.003 <0.010 12-30-92 312 0.025+/-0.003 <0.014 2nd Qtr. mean+/- s.d. 0.018+/-0.006 <0.048 4th Qtr. mean +/- s.d. 0.021+/-0.009 <0.030 . a Disk placed off-center in filter holder. 14
PALISADES Table 1. Airborne particulates and iodine-131 Collection: Weekly Units: pCi/m3 Location: 12DG - Dowagiac (30 miles SSE) Date Volume Date Volume Collected (m3) Gross Beta I-131 Collected (m3) Gross Beta I-131 01--06-92 413 0.034+/-0.003 <0.006 07--08-92 229 0.018+/-0.004 <0.015 01--08-92 71 0.045+/-0.012 <0.030 07-15-92 235 0.019+/-0.004 <0.016 01-15-92 246 0.029+/-0.004 <0.064 07-22-92 246 0.016+/-0.003 <0.012 . 01-22-92 255 0.037+/-0.005 <0.052 07-29-92 204 0.024+/-0.005 <0.021 01-29-92 249 0.027+/-0.004 <0.058 08--05-92 229 0.016+/-0.004 <0.017 02--05-92 249 0.028+/-0.004 <0.055 08-12-92 229 0.024+/-0.005 <0.008 02-12-92 252 0.022+/-0.004 <0.060 08-19-92 232 0.017+/-0.004 <0.035 02-19-92 244 0.024+/-0.004 <0.054 08-26-92 232 0.030+/-0.005 <0.031 02-26-92 244 0.020+/-0.004 <0.039 09-02-92 224 0.026+/-0.004 <0.016 03--04-92 244 0.028+/-0.004 <0.055 09-09-92 235 0.020+/-0.004 <0.017 03-11-92 244 0.024+/-0.004 <0.052 09-16-92 '2ZJ 0.024+/-0.005 <0.013 03-18-92 246 0.023+/-0.004 <0.040 09-23-92 235 0.030+/-0.005 <0.013 03-25-92 249 0.026+/-0.004 <0.044 09-30-92 232 0.024+/-0.004 <0.027
- 04-01-92 241 0.016+/-0.004
<0.062 1st Qtr. mean +/- s.d. 0.027+/-0.007 <0.064 3rd Qtr. mean +/- s.d. 0.022+/-0.005 <0.035 04-08-92 244 0.019+/-0.004 <0.049 10-07-92 232 0.032+/-0.005 <0.020 04-15-92 244 0.022+/-0.004 <0.051 10-14-92 235 0.026+/-0.004 <0.021 04-22-92 238 0.020+/-0.004 <0.040 10-21-92 241 0.029+/-0.004 <0.017 04-29-92 241 0.022+/-0.004 <0.034 10-28-92 232 0.048+/-0.005 <0.037 05--06-92 238 0.021+/-0.004 <0.050 11-04-92 232 0.018+/-0.004 <0.017 05-13-92 178 0.027+/-0.005 <0.045 11-11-92 238 0.017+/-0.004 <0.028 05-20-92 235 0.024+/-0.004 <0.015 11-19-92 2CY1 0.028+/-0.004 <0.013 05-27-92 224 0.024+/-0.004 <0.017 11-25-92 224 0.021+/-0.004 <0.016 06--04-92 263 0.019+/-0.004 <0.027 12-02-92 224 0.032+/-0.004 <0.024 06-10-92 195 0.018+/-0.004 <0.017 12-09-92 229 0.031+/-0.004 <0.017 06-17-92 224 0.026+/-0.004 <0.018 12-16-92 224 0.023+/-0.004 <0.014 06-24-92 235 0.021+/-0.004 <0.013 12-23-92 249 0.052+/-0.005 <0.016 07--01-92 '127 0.027+/-0.004 <0.014 12-30-92 269 0.033+/-0.004 <0.016 2nd Qtr. mean +/- s.d. 0.022+/-0.003 <0.051 4th Qtr. mean +/- s.d. 0.030+/-0.010 <0.037 15
~* PALISADES Table2. Gamma Radiation, as measured by TLDs Exposure: Monthly Units: mR/30 days neta January Date Placed 12-29-91 Date Removed 02-02-92 In-Transit (mR) 3.8::t:D.2 Location ST-01 3.2+/-0.3 ST-02 4.3::t:D.4 ST-03 3.9::t:D.3 ST-04 4.2+/-0.4 ST-05 3.9::t:D.4 ST-06 5.1+/-0.5 ST-07A 3.7+/-0.3 ST-08 3.7::t:D.4 ST-09 3.2+/-0.3 ST-10 5.6+/-0.sb ST-11 5.4+/-Q.6b ST-12 3.8+/-0.5 ST-13 3.1+/-0.3 ST-14 2.3::t:D.2 ST-15 29::t:D.3 ST-16 2.0+/-0.3 ST-17 3.S::t:D.3 ST-18 3.0+/-0.3 ST-19 3.9::t:D.3 ST-20 3.S::t:D.2 ST-21 3.4+/-0.2 ST-22 2.2+/-0.2 ST-23 3.9::t:D.3 ST-24 3.4+/-0.3 ST-33 2.S::t:D.2 ST-34 2.7+/-0.3 ST-35 3.4+/-0.2 ST-36 2.6+/-0.2 ST-37 2.9::t:D.2 ST-38 2.4+/-0.3 Mean+/-s.d. 3.4+/-0.9 Control,1 2.0+/-0.2 Control 2 1.9::t:D.2 a In-transit exposure has been subtracted from total exposure. b Placed 01-02-92; removed 01-31-92. c Placed 01-31-92; removed 02-26-92. d Placed 01-31-92; removed 02-27-92. 16 February March 02-02-92 03-01-92 03-01-92 03-29-92 20::t:D.2 4.4+/-0.3 4.6+/-0.2 3.8+/-0.5 5.2+/-0.2 6.7+/-0.4 4.4+/-0.3 5.2+/-0.8 6.2+/-0.3 6.7+/-0.3 4.5+/-0.3 5.6+/-0.6 4.7+/-0.2 6.3::t:D.4 4.8+/-0.2 5.7::t:D.6 4.4+/-0.2 2.9::t:D.3e 3.9::t:D.3 4.4+/-0.4 5.0::t:D.2 c 4.0+/-0.7f 4.5+/-0.3d 4.S::t:D.2g 5.0::t:D.2 5.0+/-0.6 4.7+/-0.2 4.l::t:D.6 3.6+/-0.2 3.4+/-0.5 3.6+/-0.2 3.7::t:D.5 4.0::t:D.2 2.7+/-0.3 4.0::t:D.2 4.2+/-0.4 4.4+/-0.2 4.3::t:D.7 4.0::t:D.4 5.6+/-0.5 4.0::t:D.2 5.0+/-0.9 3.9+/-0.2 4.9::t:D.8 21+/-0.2 3.0+/-0.Jh 4.3+/-0.2 5.S::t:D.7 3.5+/-0.2 4.l::t:D.4 3.4+/-0.2 3.6+/-0.3 3.5+/-0.2 3.2+/-0.S 4.7+/-0.2 4.S::t:D.3 3.6+/-0.2 5.2+/-0.3 4.0::t:D.2 4.0+/-0.4 3.7+/-0.2 3.4+/-0.4 4.2+/-0.7 4.~1.1 21+/-0.2
- 1. 9::t:D.3 h 22+/-0.2
- 1. 9::t:D.3 h e Placed 0~1-92; removed 04-15-92.
f Placed 02-26-92; removed 04--01-92. g Placed 02-27-92; removed 04-15-92. _ h Removed 04-01-92.
PALISADES Table 2. Gamma Radiation, as measured by TLDs (continued) Exposure: Monthly Units: mR/30 days neta April May LYM Date Placed 03-29-92 05-03-92 05-30-92 Date Removed 05-03-92 05-30-92 06-28-92 In-Transit (mR) 3.8+/-0.2 4.3+/-0.2 4.1+/-0.2 Location ST-01 3.4+/-0.3 3.6+/-0.3 4.1+/-0.7 ST-02 4.8+/-0.2 5.5+/-1.0 5.9+/-0.4 ST-03 4.3+/-0.3 4.5+/-0.4 5.5+/-0.3 ST-04 4.5+/-0.3 5.2+/-0.3 5.1+/-0.3 ST-05 4.2+/-0.2 4.6+/-0.4 5.1+/-0.3 ST-06 4.9+/-0.2 5.3+/-0.6 5.4+/-0.3 ST-07A 3.8+/-0.2 4.0+/-0.4 5.3+/-0.2 ST-08 4.0+/-0.2 4.1+/-0.5 4.4+/-0.4 ST-09 3.4+/-0.2 3.6+/-0.3 4.0+/-0.5 ST-10 3.7+/-0.Jb 3.7+/-0.5e 3.7f0.4h ST-11 4.7+/-Q.4C Nof 4.6f0.3h ST-12 3.7+/-0.3 4.2+/-0.4 4.3+/-0.3 ST-13 3.6+/-0.3 3.3+/-0.4 3.9+/-0.5 ST-14 2.9+/-0.2 25+/-0.2 3.4+/-0.2 ST-15 3.0+/-0.2 3.1+/-0.3 . 3.9+/-0.3 ST-16 3.8+/-0.2 1.9+/-0.3 4.1+/-0.3 ST-17 3.8+/-0.5 3.0+/-0.3 4.0+/-0.2 ST-18 3.5+/-0.2 3.5+/-0.5 4.2+/-0.3 ST-19 3.7+/-0.3 4.0+/-0.3 4.7+/-0.3 ST-20 3.6+/-0.3 4.8+/-0.3 4.2+/-0.4 ST-21 3.6+/-0.3 3.3+/-0.3 4.2+/-0.4 ST-22 4.3+/-0.5 21+/-0.3 2.7+/-0.3 ST-23 4.0+/-0.2 . 4.4+/-0.3 4.5+/-0.3 ST-24 2.7+/-0.2 4.2+/-0.3 4.0+/-0.2 ST-33 3.3+/-0.2 3.0+/-0.3 ND8 ST-34 3.3+/-0.3 22+/-0.3 3.6+/-0.3 ST-35 4.4+/-0.3 4.0+/-0.3 4.4+/-0.3 ST-36 3.6+/-0.3 2.5+/-0.2 3.5+/-0.2 ST-37 3.2+/-0.2 3.2+/-0.3 4.0+/-0.5 ST-38 3.5+/-0.2 2.4+/-0.3 3.6+/-0.3 Mean+/-s.d. 3.8+/-0.6 3.6+/-1.0 4.3+/-0.7 Control 1 2.3+/-0.2d Nl)g 2.1+/-0.2 Control 2 2.2+/-0.Jd 2.4+/-0.3 2.1+/-0.2 a In-transit exposure has been subtracted from total exposure. e Placed 04-29-92; removed 05-28-92. b Placed 04-02-92; removed 04-29-92.. f ND = no data; wrong TLD collected. c Placed 04-01-92; removed 05-04-92. g ND = no data; TLD lost in the field. d Placed 04-01-92; removed ~92. hND =placed 05-~92; removed 07-1-92 17
PALISADES Table 2. Gamma Radiation, as measured by TLDs (continued) Exposure: Monthly Units: mR/30 days neta Date Placed Date Removed In-Transit (mR) Location ST-01 ST-02 ST-03 ST-04 ST-OS ST-06 ST-07A ST-08 ST-09 ST-10 ST-11 ST-12 ST-13 ST-14 ST-15 ST-16 ST-17 ST-18 ST-19 ST-20 ST-21 ST-22 ST-23 ST-24 ST-33 ST-34 ST-35 ST-36 ST-37 ST-38 Mean+/-s.d. Control 1 Control 2 ~ 06-28-92 08-02-92 1.8::!:0.2 4.3::!:0.2 6.6+/-0.3 5.0+/-0.3 5.3+/-0.2 5.3+/-0.3 5.6+/-0.3 4.9+/-0.2 5.3+/-0.3 4.5+/-0.2 S.3+/-0.3b 3.2+/-0.lc,g 5.2+/-0.3 4.1+/-0.2 3.9+/-0.2 4.0+/-0.3 3.7+/-0.3 4.3+/-0.3 4.5+/-0.2 5.2+/-0.2 5.2+/-0.3 4.7+/-0.3 3.0+/-0.3 5.4+/-0.3 4.9+/-0.2 4.9+/-0.3 4.0+/-0.3 5.3+/-0.2 4.1+/-0.2 4.1+/-0.2 3.8+/-0.2 4.7+/-0.7 1.3+/-0.2 2.2+/-0.2 August 08-02-92 08-30-92 4.0::l:0.2 4.S::l:0.4 S.B::l:0.4 4.9::!:0.3 5.3::!:0.2 S.O::l:0.3 5.9::!:0.3 S.l::l:0.4 4.8+/-0.4 3.9::!:0.2 4.6+/-0.3d S.2+/-0.2e 4.9::!:0.S 4.2+/-0.3 3.9::!:0.4 4.4+/-0.4 4.5+/-0.3 4.6+/-0.3 4.5+/-0.3 4.8+/-0.3 4.6+/-0.3 4.7+/-0.3 2.9::!:0.2 5.4+/-0.2 4.6+/-0.3 4.2+/-0.2 4.2+/-0.2. 5.2+/-0.4 4.1+/-0.3 3.7+/-0.3 4.2+/-0.3 4.6+/-0.6 2.0::l:0.2 2.1+/-0.2 September 08-30-92 1~92 4.0+/-D.3 3.5+/-0.3 7.0+/-0.4 4.7+/-0.4 4.6+/-0.4 S.O+/-D.6 5.6+/-0.3 4.3+/-0.4 4.1+/-0.3 4.6+/-0.4 NJ)C S.2+/-0.sf 5.3+/-0.6 3.6+/-0.3 3.5+/-0.3 . 3.7+/-0.4 3.4+/-0.3 3.9+/-0.3 3.7+/-0.3 4.3+/-0.3 4.3+/-0.6 4.4+/-0.3 2.3+/-0.3 5.3+/-0.5 NJ)C 3.4+/-0.3 3.0+/-0.2 4.3+/-0.4 4.0+/-0.3 3.9+/-0.4 3.7+/-Q.3 4.2+/-0.9 0.9+/-0.3 2.1+/-{).3 a In-transit exposure has been subtracted from total exposure.£ Placed 09-02-92; removed 10 b Placed 07-01-92; removed 07-31-92. g TLD found. Placed 07-01-92; removed 10-05-92; c ND= No Data, TLD lost in the field. 96 days in the field; result prorated for 30 days. d Placed 7-31-92; removed 9-2-92. e Placed 7-28-92; removed 9-2-92. 18
PALISADES Table 2. Gamma Radiation, as measured by TLDs (continued) Exposure: Monthly Units: mR/30 days net'! October NQv~m:Q~r D~~mQ~r Date Placed 10-04-92 11-01-92 11-29-92 Date Removed 11-01-92 11-29-92 01-03-93 In-Transit (mR) 3.6+/-0.2 4.2+/-0:2 5.2+/-0.2 Location ST-01 3.9+/-0.7 3.8+/-0.2 3.1+/-0.3 ST-02 4.4+/-0.3 5.5+/-0.3 4.9+/-0.2 ST-03 4.4+/-0.5 4.6+/-0.3 4.6+/-0.2 ST-04 4.0+/-0.3 5.2+/-0.3 4.9+/-0.2 ST-05 4.1+/-0.5 5.1+/-0.4 4.8+/-0.4 ST-06 4.5+/-0.3 5.4+/-0.2 4.6+/-0.3 ST-07A 4.1+/-0.4 4.0+/-0.2 4.6+/-0.2 ST-08 5.9+/-0.4 4.2+/-0.2 4.6+/-0.4 ST-09 4.4+/-0.4 3.7+/-0.2 3.9+/-0.2 ST-10 3.8+/-0.3b 3.3::t0.2d 4.8+/-0.3g ST-11 4.7+/-0.4C 4.7::t:0.3e 5.5+/-0.4g ST-12 4.0+/-0.6 4.0+/-0.3 4.6+/-0.3 ST-13 3.3+/-0.3 4.4+/-0.3 3.8+/-0.2 ST-14 3.0+/-0.3 2.7+/-0.3 3.3+/-0.2 ST-15 3.1+/-0.3 3.9+/-0.3 3.7+/-0.2
- ST-16 3.3+/-0.3 4.7+/-0.4 4.0+/-0.2 ST-17 2.9+/-0.2 4.1+/-0.2 3.3+/-0.3 ST-18 3.2+/-0.3 3.6+/-0.2 4.1+/-0.2 ST-19 3.5+/-0.3 5.0+/-0.3 4.3+/-0.4 ST-20 3.3+/-0.3 4.4+/-0.3 4.1+/-0.3 ST-21 3.5+/-0.3 4.2+/-0.2 4.2+/-0.3 ST-22 1.6+/-0.3 3.4+/-0.4 2.5+/-0.4 ST-23 4.4+/-0.4 4.9+/-0.4 3.4+/-0.3 ST-24 3.5+/-0.2 3.5+/-0.2 4.4+/-0.3 ST-33 4.2+/-0.4 3.9+/-0.3 4.7+/-0.3 ST-34 4.0+/-0.5 3.9+/-0.3 4.1+/-0.2 ST-35 3.9+/-0.2 4.4+/-0.3£ 4.3+/-0.2 ST-36 2.7+/-0.2 3.9+/-0.2 3.4+/-0.2 ST-37 4.2+/-0.4 4.4+/-0.4 3.4+/-0.2 ST-38 3.0+/-0.2 4.0+/-0.3 3.7+/-0.2 Mean+/-s.d.
3.8+/-0.8 4.2+/-0.7f 4.1+/-0.7 Control 1 1.8+/-0.3 2.5+/-0.3 2.1+/-0.3 Control 2 1.8+/-0.3 2.1+/-0.3 2.1+/-0.3 a In-transit exposure has been subtracted from total exposure. b Placed 09-30-92; removed 10-~92. g Placed 11-~92; removed 12-31-92. c Placed 10-05-92; removed 10-29-92. d Placed 10-30-92; removed 11-~92. e Placed 10-29-92; removed 11-~92. f Corrected data. 19
PALISADES Table3. Gamma Radiation, as measured by TLDs Exposure: Quarterly Units: mR/91 days neta 1st Otr. 2nd Otr. 3rd0tr. 4th Otr. Date Placed 12-29-91 03-29-92 06-28-92 10-04-92 Date Removed 03-29-92 06-28-92 10-04-92 01-03-93 In-Transit (mR) 4.9+/-0.6 3.6+/-0.6 4.8+/-0.7 5.1+/-0.6 Location ST-01 12.6+/-0.8 11.9+/-0.6 12.9+/-0.7 10.9+/-0.7 ST-02 17.5+/-0.9 16.8+/-0.7 19.2+/-0.7 15.4+/-0.6 ST-03 13.6+/-0.7 13.3+/-0.6 15.3+/-0.6 12.9+/-0.7 ST-04 15.4+/-0.6 13.7+/-0.6 16.4+/-0.9 13.4+/-0.7 ST-05 15.0+/-0.6 13.6+/-0.6 16.2+/-0.8 12.9+/-0.7 ST-06 17.0+/-0.8 16.1+/-0.7 17.9+/-0.7 14.7+/-0.7 ST-07A 13.8+/-1.0 11.5+/-0.6 13.9+/-0.7 11.0+/-0.6 ST-08 10.7+/-0.6b 11.5+/-0.7 13.2+/-0.8 11.4+/-0.6 ST-09 13.3+/-1.1 10.9+/-0.7 13.4+/-0.8 10.0+/-0.7 ST-10 126+/-1.lb 11.1+/-0.6d,e NDg 10.8+/-0.7i ST-11 14.1+/-0.6b 10.4+/-1.of 15.5+/-0.7h 13.3+/-0.l'i ST-12 13.0+/-0.7 12.7+/-0.6 14.0+/-0.7 12.1+/-0.7 ST-13 9.4+/-0.8 11.5+/-0.7 9.6+/-0.7 11.0+/-0.7 ST-14 10.7+/-0.7 10.5+/-0.6 11.3+/-0.6 10.0+/-0.6 ST-15 10.4+/-0.7 10.4+/-0.6 10.9+/-0.7 9.8+/-0.7 ST-16 10.1+/-0.8 10.8+/-0.6 11.0+/-0.6 10.9+/-0.6 ST-17 11.9+/-0.7 11.0+/-0.6 122+/-0.8 10.2+/-0.7 ST-18 12.0+/-0.7 10.6+/-0.7 12.6+/-0.7 10.0+/-0.7 ST-19 12.9+/-1.2 127+/-0.7 13.8+/-0.7 11.7+/-0.7 ST-20 12.2+/-0.7 12.1+/-0.6 13.2+/-0.7 11.3+/-0.6 ST-21 12.1+/-0.7 11.4+/-0.6 129+/-0.7 10.8+/-0.7 ST-22 6.7+/-0.7 6.2+/-0.6 6.2+/-0.8 5.7+/-0.7 ST-23 12.9+/-1.2 128+/-0.6 125+/-0.7 11.1+/-0.7 ST-24 12.1+/-0.7 11.2+/-0.7 ~ 11.1+/-0.7 ST-33 9.9+/-0.6 11.1+/-0.8 11.0+/-0.6 10.9+/-0.7 ST-34 10.0+/-0.6 10.7+/-0.7 10.6+/-0.7 10.9+/-0.6 ST-35 13.2+/-0.7 14.2+/-0.7 13.7+/-0.6 13.1+/-0.7 ST-36 9.6+/-0.7 11.4+/-0.7 9.9+/-0.7 10.8+/-0.7 ST-37 11.8+/-0.7 11.8+/-0.6 122+/-0.7 11.4+/-0.7 ST-38 10.1+/-0.8 11.0+/-0.7 10.3+/-0.8 10.1+/-0.7 Mean+/-s.d. 12.2+/-2.3 11.8+/-1.9 12.9+/-2.7 11.3+/-1.8 Control 1 6.2+/-0.6 6.S+/-0.6d 6.7-j;JJ.7 5.9+/-0.7 Control 2 3.6+/-0.7C 6.S+/-0.7d 4.0+/-0.7 5.8+/-0.7 a In-transit exposure has been subtracted from total exposure. f Placed 04-01-92; removed 05-28-92. b Placed 01-<>2-92; removed 04-01-92. g ND = No Data; TLD lost in the *field. c Unreliable reading; card appears to have been damaged. h Pla<:ed 07-01-92; removed 10-05-92. d Placed 04-01-92. i Placed 09-30-92; removed 12-31-92. e Removed 07-01-92. j Pla<:ed 1~92; removed 01-16-92. 20
PALISADES Table4. Gamma Radiation, as measured by TLDs Exposure: Yearly Units: mR/365 days net'! Date Placed 12-29-91 Date Removed 01-03-93 In-Transit (mR) 23+/-2.5 Location ST-01 50.0+/-2.4 ST-02 69.9+/-2.6 ST-03 56.7+/-2.5 ST-04 58.1+/-2.4 ST-05 60.3+/-2.6 ST-06 66.4+/-2.6 ST-07A 52.6+/-2.5 ST-08 51.2+/-2.6 ST-09 47.9+/-2.6 ST-10 Noa ST-11 56.4+/-2.6 ST-12 528+/-2.5 ST-13 ~.8+/-2.5 ST-14 420+/-2.4 ST-15 426+/-2.7 ST-16 47.1+/-2.5 ST-17 44.3+/-2.5 ST-18 47.1+/-2.5 ST-19 51.4+/-2.5 ST-20 47.2+/-2.6 ST-21 525+/-2.5 ST-22 25.1+/-2.5 ST-23 56.4+/-2.4 ST-24 Nob ST-33 Nob ST-34 48.8+/-2.4 ST-35 59.0+/-2.4 ST-36 47.1+/-2.6 ST-37 48.8+/-2.6 ST-38 46.8+/-2.6 Mean+/-s.d. 50.9+/-8.5 Control 1 24.6+/-2.4 Control 2 24.8+/-2.4 a In-transite exposure has been subtracted from total exposure. b ND-TLD missing c Placed 01-02-92; removed 01-06-93. 21
PALISADES Table 5. Lake Water, Intake and Discharge Collection: Monthly Composites of daily collections Units: pCi/L 1992 Compositing Gross Period Lab Code Alpha Required LLD 1.0 Intake January PALW-4454 <1.0 February 4770 <0.4 March 5265 <0.3 April 5621 <0.9 May 6015 <0.5 June 6482 <0.S July 6931 <0.3 August 7275 <1.0 September 7630 <0.4 October 8165 0.8+/-0.3 November 8344 <0.1 December 8778 0.4+/-0.3 Discharge January PALW-4455 <0.9 February 4771 <0.4 March 5266 <0.4 April 5622 <0.9 May 6016 <0.5 June 6483 <0.2 July 6932 <0.4. August 7276 0.6+/-0.3 September 7631 <0.4 October 8166 0.6+/-0.3 November 8345 <0.4 December 8779 <0.4 a Analysis was repeated; result of reanalysis 5028+/-147 pCi/L b Corrected data. 22 Gross Beta 4.0 1.8+/-0.5 2.6+/-0.3 2.2+/-0.3 1.7+/-0.5 2.3+/-0.3 2.4+/-0.5 1.9+/-0.3 2.1+/-0.5 2.0+/-0.3 2.6+/-0.3 2.0+/-0.6 22+/-0.3 24+/-0.6 2.2+/-0.3 2.1+/-0.3 22+/-0.6 22+/-0.3 26+/-0.5 3.2+/-0.3 23+/-0.3 21+/-0.3 27+/-03 2.2+/-0.3 2.0+/-0.3 Tritium 500 169+/-92 <180 <165 96+/-93 <170 155+/-88 <188 <185 <168 103+/-91 183+/-91b <164 144+/-91 <180 4701+/-199a 132+/-67 148+/-90 2148+/-148 <188 <185 3152+/-175 <175 <176 3203+/-171
PALISADES Tables.
- Lake Water (continued)
Collection: Monthly Units: pCi/L Location: Ludington Intake (Control) Required Sample Description and Concentration UD !'!I.,,.,;,. Date Collected 01-31-92 02-29-92 03-31-92 04-30-92 Lab Code PALW-4527 PALW-4822 PALW-5370 PALW-5670 Gross Alpha <1.0 <0.7 <0.4 <0.5 1.0 Gross Beta 2.1+/-0.5 1.4:ifl.6 1.9+/-0.3 2.0+/-0.3 4.0 Sr-89 <0.8 <0.7 <0.7 <1.0 5.0 Sr-90 <0.5 <0.5 <0.6 <0.6 1.0 H-3 188+/-93 96+/-93 103+/-88 <170 500 Date Collected 05-31-92 07-01-92 07-31-92 08-31-92 Lab Code PALW-6010 PALW-6467 PALW-6828 PALW-7428 Gross Alpha <0.3 <0.6 <0.5 <0.4 1.0 Gross Beta l,4+/-Qj 1.9+/-0.5 1.6+/-03 2.2+/-0.3 4.0 Sr-89 <0.9 <0.9 <0.9 <0.7 5.0 Sr-90 <0.4 0.9iD.4 0.9+/-0.4 <0.5 1.0 H-3 <170 155+/-89 114+/-94 105+/-95 500 Date Collected 09-30-92 10-31-92 11-30-92 01-04-93 Lab Code PALW-7636 PALW-8115 PALW-8468 PALW-8981 Gross Alpha * <0.5 0.8+/-0.4 <0.5 <0.4 1.0 Gross Beta 1.9+/-0.3 3.5+/-0.4 21+/-0.3 2.1+/-03 4.0 Sr-89 <0.9 <l.3 <0.8 <0.7 5.0 Sr-90 0.9+/-0.3 0.6+/-0.4 <0.5 . <0.6 1.0 H-3 <178 <175 <176 <171 500 23
PALISADES Table 6. Lake Water, Drinking Collection: Monthly Composites of daily collections Units: pCi/L 1992 South Haven Munici12al Sxstem Compositing Treated Raw Period Lab Code Gross Beta H-3 Lab Code Gross Beta Required LLD 4.0 500 4.0 January PALW-4460 23+/-0.6 158+/-91 PALW-4461 21+/-0.6 February 4773 1.3+/-0.6 <183 4774 1.6+/-0.6 March 5263 1.3+/-0.6 <165 5264 1.9+/-0.3 April 5619 22+/-0.6 125+/-94 5620 22+/-0.6 May 6012 1.7+/-0.5 <170 6013,4 21+/-0.4 June 6479,80 21+/-0.4 147+/-66 6481 22+/-0.5 July 6929 20+/-0.3 <188 6930 1.8+/-0.3 August 7127 20+/-0.5 174+/-95 7128 20+/-0.5 September 7831 26+/-0.5 <171 7832 20+/-0.5 October 8123 23+/-0.3 96+/--91 8124 1.8+/-0.6 November 8357 26+/-0.6 <168 8356 1.8+/-0.6 December 8874 24+/-0.4 <170 8873 24+/-0.4 24
Table7. 1992 Collection Period Reauired LLD January February March April May June July August September October November December January February March April May June July August September October November December PALISADES Well Water Collection: Monthly Units: pCi/L Lab Code Gross Beta H-3 4.0 Site Wells No. 2 and 3 IDomestic) PAWW-4456 0.9+/-0.5 158+/-91 4772 <0.9 <183 5267,8 0.8+/-0.4 148+/-65 5623 1.6+/-0.6 110+/-94 6017 1.0+/-0.5 260+/-95 6484 1.2+/-0.5 340+/-101 6933 1.1+/-03 <185 7273 20+/-0.6 <185 7632,3 1.2+/-0.3 163+/-64 8167 1.2+/-0.6 <175 8347,8 1.2+/-1.0 <176 8780 1.1+/-0.3 <164 Township Park PAWW-4188 23+/-0.3 <180 4459 23+/-0.6 146+/-90 4777 3.4+/-0.3 111+/-96 5256,7 22+/-0.5 <165 5627 21+/-0.5 <170 6021 1.8+/-0.5 <171 6473 1.6+/-0.5 <167 6923 1.8+/-0.3 <181 7125 24+/-0.3 <185 7830 1.7+/-0.5 <174 8125 1.5+/-0.7 <168 8350 25+/-0.6 <179 25 Lab Code Gross Beta -H..:3-*,,-,.. -,,--.. * *
- 4.0
'500 State Park PAWW-4186,7 4457,8 4775,6 5255 5625,6 6020 6472 6922 7272 7829 ~126 8349 0.9+/-0.2 1.2+/-0.4 0.8+/-0.2 1.1+/-0.7 0.8+/-0.3 3.5+/-0.5 3.9+/-0.5 3.4+/-0.3 2.3+/-0.3 3.5+/-0.5 <1.3 <1.0 <180 181+/-64 83:1:66 <165 113+/-66 <171 <167 <181 <185 <174 <176 178+/-89
PALISADES Table 7. Well Water (continued) Collection: Monthly Units: pCi/L Location: Ludington (Control) Required Sample Description and Concentration LID Date Collected 01-31-92 02-29-92 03-31-92 04-30-92 Lab Code PAWW-4528 PAWW-4823 PAWW-5371 PAWW-5671 Gross Alpha <0.5 <0.9 <0.5 <0.5 1.0 Gross Beta <0.8 <0.9 <0.4 <0.4 4.0 Sr-89 <1.2 <0.8 <0.8 <1.0 5.0 Sr-90 <0.9 <0.6 <0.5 <0.6 1.0 H-3 160+/-92 <179 <170 <170 500 Date Collected 05-31-92 07-01-92 07-31-92 08-31-92 Lab Code PAWW-6011 PAWW-6468 PAWW-6829 PAWW-7429 Gross Alpha <0.5 0.6fil.3 <0.5 <0.6 Gross Beta <0.4 <1.0 <0.4 <0.4 Sr-89 <1.2 <0.9 <0.8 <0.8 Sr-90 <0.8 <0.6 <0.5 <0.4 H-3 <170 <166 <180 <184 Date Collected 09-30-92 10-31-92 11-30-92 01-04-93 Lab Code PAWW-7637 PAWW-8116 PAWW-8469 PAWW-8982 Gross Alpha <0.6 <0.6 <0.6 <0.6 1.0 Gross Beta <0.4 0.8+/-0.3 <0.4 0.4+/-0.3 4.0 Sr-89 <1.1 <2.4 <0.9 <0.9 5.0 Sr-90 <0.5 <0.7 <0.5 <0.5 1.0 H-3 <168 <175 <176 <171 500 26
PALISADES Table 7. Well Water (continued) Collection: Monthly Units: pCi/L Location: Warehouse (Site Well #7) Required Sample Description and Concentration LID Date Collected 01-14-92 02-10-92 03-04-92 Lab Code PAWW-4184 PAWW-4526 PAWW-4781 Gross Beta 6.2+/-0.5b 6.6+/-0.6b 6.5+/-0.8b 4.0 Sr-89 <0.9 <0.6 <0.5 5.0 Sr-90 1.3+/-0.5 1.6+/-0.5 1.5+/-0.4 1.0 H-3 <180 <168 <174 500 1-131 <0.3 <0.3 <0.3 1.0 Cs-134 <7.8 <4.1 <5.0 15.0 Cs-137 <6.9 <4.1 <4.1 18.0 Other Gammasa <7.5 <5.4 <4.0 -15.0 Date Collected 04-06-92 05-05-92 06-08-92 Lab Code PAWW-5261 PAWW-5631 PAWW-6025 Gross Beta 6.2+/-1.ob 5.4+/-1.ob -6.4+/-0.9b 4.0 Sr-89 <0.6 <0.7 <0.9 5.0 Sr-90 1.8+/-0.4 1.7+/-0.4 1.2+/-0.4 1.0 H~3 <165 <170 <171 500 1-131 <0.4 <0.4 <0.2 1.0 Cs-134 <4.5 <5.3 <5.1 15.0 Cs-137 <4.5 <5.2 <5.3 18.0 Other Gammasa <4.8 <5.5 <5.0 15.0 a See Introduction. b Analysis was repeated at request of Palisades: results of reanalysis PA WW-4184 6.1+/-0.9 P AWW-6025 6.9+/-0.9 4526 4.9+/-0.8 4781 7.4+/-1.0 5261 5.9+/-0.5 5631 6.0+/-0.6 27
Table 7. Well Water (continued) Collection: Monthly Units: pCi/L PALISADES Location: Warehouse (Site Well #7) Sample Description and Concentration Date Collected 07-07-92 08-11-92 09:-01-92 Lab Code PAWW-6477 PAWW-6927 PAWW-7126 Gross Beta 5.5+/-0.8b 5.7+/-0.8b 8.5+/-0.5b Sr-89 <1.3 <1.0 <0.9 Sr-90 2.1+/-0.5 1.9+/-0.5 1.5+/-0.4 H-3 <167 115+/-94 132+/-94 I-131 <0.3 <0.4 <0.5 Cs-134 <6.0 <2.2 <3.1 Cs-137 <6.5 <2.1 <5.2 Other Gammasa <6.3 <2.2 <5.1 Date Collected 10-06-92 11-21-92 12-02-92 Lab Code PAWW-7627 PAWW-8121 PAWW-8352 Gross Beta 5.s+/-0.8b 5.4+/-0.sb 0.9+/-0.6b Sr-89 <0.8 <0.9 <0.9 Sr-90 1.3+/-0.4 1.6+/-0.4 <0.5 H-3 <178 <180 <179 I-131 <J.7C <0.2 <0.3 Cs-134 <4.8 <5.2 <4.6 Cs-137 <4.1 <4.9 <4.8 Other Gammasa <4.1 <5.3 <4.8 a See Introduction.. b Analysis was repeated; result of reanalysis: PAWW-6477 7.1+/-1.0 c LLD not reached due to delay in sample analysis. -6927 6.6+/-1.0 -7126 6.6+/-0.9 28 Required UD 4.0 5.0 1.0 500 1.0 15.0 18.0 15.0 4.0 5.0 1.0 500 1.0 15.0 18.0 15.0 -7627 7.4+/-0.9 -8121 6.2+/-0.9 -8352 0.9+/-0.3
PALISADES Table 7. Well Water (continued) Collection: Monthly Units: pCi/L Location: Outage Building (Site Wells# 11, 12 and 13) Required Sample Description and Concentration LID Date Collected 01-14-92 02-05-92 03-04-92 lab Code PAWW-4185 PAWW-4451 PAWW-4782 Gross Beta 1.0+/--0.3 <1.2 1.1+/-{).5 4.0 Sr-89 <0.7 <0.6 <0.5 5.0 Sr-90 <0.4 <0.5 <0.4 1.0 H-3 <180 240+/-93 <174 500 1-131 <0.3 <0.4 <0.3 1.0 Cs-134 <5.4 <3.3 <7.0 15.0 Cs-137 <4.5 <4.1 <6.4 18.0 Other Gammasa <4.0 <3.8 <6.3 15.0 Date Collected 04-06-92 05-05-92 06-08-92 I.ab Code PAWW-5262 PAWW-5632 PAWW-6026 Gross Beta 1.0+/--0.5 1.3+/-{).7 <0.9 4.0 Sr-89 <0.7 <0.9 <0.8 5.0 Sr-90 <0.4 <0.5 <0.6 1.0 H-3 <165 110+/-94 <171 500 1-131 <0.3 <0.4 <0.2 1.0 Cs-134 <4.0 <6.3 <5.9 15.0 Cs-137 <3.7 <5.3 <5.3 18.0 Other Gamrnasa <4.3 <7.9 <6.4 15.0 a See Introduction. 29
Table7. Well Water (continued) Collection: Monthly Units: pCi/L PALISADES Location: Outage Building (Site Wells# 11, 12 and 13) Sample Description and Concentration Date Collected 07-07-92 08-11-92 09-09-92 Lab Code PAWW-6478 PAWW-6928 PAWW-7271 Gross Beta <0.9 <0.9 <0.9 Sr-89 <1.5 <0.9 <1.5 Sr-90 <0.6 <0.4 <0.6 H-3 263+/-98 127+/-95 124+/-94 1-131 <0.3 <0.3 <0.4 Cs-134 <4.1 <1.8 <5.9 Cs-137 <4.2 <1.6 <5.0 Other Gammasa <6.1 <1.6 <6.0 Date Collected 10-06-92 11-18-92 12-02-92 Lab Code PAWW-7826,7 PAWW-8122 PAWW-8351 Gross Beta <1.2 0.70+/-0.5 6.1+/-0.8b Sr-89 <1.0 <1.6 <0.8 Sr-90 <0.6 <0.8 1.9+/-0.5 H-3 <176 <180 <179 1-131 <0.7 <0.2 <0.2 Cs-134 <4.0 <4.3 <3.8 Cs-137 <4.1 <4.5 <3.3 Other Gammasa <4.9 <4.2 <3.6 a See Introduction. b Analysis was repeated; result of reanalysis: PAWW-8351 6.7+/-0.9 30 Required LID 4.0 5.0 1.0 500 1.0 15.0 18.0 15.0 4.0 5.0 1.0 500 1.0 15.0 18.0 15.0
Table 7. Well Water (continued) Collection: Monthly Units: pCi/L Location: Site Well #14 PALISADES Sample Description and Concentration Date Collected 01-14-92 02-10-92 03-04-92 Lab Code PAWW-4181 PAWW-4525 PAWW-4778 Gross Beta 6.5+/-0.5b 4.1+/-0.8b 5.9+/-0.8b Sr-89 <0.8 <0.6 <1.0 Sr-90 <0.5 <0.5 <0.5 H-3 <181 178+/-91 <174 Cs-134 <5.4 <6.6 <6.7 Cs-137 <4.4 <4.8 <5.8 Other Gammasa <4.6 <4.0 <9.3 Date Collected 04-06-92 05-05-92 06-08-92 Lab Code PAWW-5258 PAWW-5628 PAWW-6022 Gross Beta 4.5+/-0.7b 3.9+/-0.9 3.3+/-0.7 Sr-89 <0.6 <0.9 <0.9 Sr-90 0.6+/-0.3 <0.5 <0.6 H-3 <165 <170 <171 Cs-134 <3.7 <4.6 <4.0 Cs-137 <3.8 <4.7 <4.0 Other Gammasa <4.2 <4.1 <5.5 a See Introduction. b Analysis was repeated at request of Palisades: results of reanalysis PAWW-4181 5.4+/-0.8 PAWW-5258 4525 3.6+/-0.9 4778 4.0+/-0.8 31 Required I.lD 4.0 5.0 1.0 500 15.0 18.0 15.0 4.0 5.0 1.0 500 15.0 18.0 15.0 4.2+/-0.4
Table7. Well Water (continued) Collection: Monthly Units: pCi/L Location: Site Well #14 PALISADES Sample Description and Concentration Date Collected 07-07-92 08-11-92 09-09-92 Lab Code PAWW-6474 PAWW-6924 PAWW-7268 Gross Beta 5.7+/-0.7b 6.9+/-0.8b 2.9+/-0.6 Sr-89 <0.8 <0.9 <1.7 Sr-90 <0.5 <0.4 <0.6 H-3 <167 178+/-95 185 Cs-134 <4.7 <4.7 <5.9 Cs-137 <4.4 <4.7 <6.0 Other Gammasa <4.0 <4.2 <6.4 Date Collected 10-06-92 11-18-92 12-02-92 Lab Code PAWW-7828 PAWW-8117 PAWW-8353 Gross Beta 1.6+/-0.7 1.3+/-0.9C 11.2+/-1.ob Sr-89 <1.4 <1.0 <1.4 Sr-90 <0.7 <0.5 <0.6 H-3 <174 <178 <178 Cs-134 <5.0 <3.8 <4.9 Cs-137 <4.4 <3.8 <4.6 Other Gammasa <4.8 <3.9 <5.3 a See Introduction. b Analysis wa8 repeated; result of reanalysis: PAWW-6474 3.6+/-0.8 c Average of two repeated analysis. -6924 6.7+/-0.9 -8353 11.6+/-0.9 32 Required LID 4.0 5.0 1.0 500 15.0 18.0 15.0 4.0 5.0 1.0 500 15.0 18.0 15.0
Table7. Well Water (continued) Collection: Monthly Units: pCi/L Location: Site Well #15 PALISADES Sample Description and Concentration Date Collected 01-14-92 02-05-92 ~92 Lab Code PAWW-4182 PAWW-4449 PAWW-4779 Gross Beta 3.8+/-0.4 5.0+/-0.9b 5.6+/-0.8b Sr-89 <0.8 <0.7 <0.6 Sr-90 <0.5 <0.5 0.8+/-0.3 H-3 <181 <169 <174 Cs-134 <8.0 <6.2 <6.6 Cs-137 <7.0 <5.2 <6.4 Other Gammasa <8.2 <4.9 <7.9 Date Collected 04-06-92 05-05-92 06-08-92 Lab Code PAWW-5259 PAWW-5629 PAWW-6023 Gross Beta 5.0+/-0.9b 3.3+/-0.8 5.1+/-0.8b Sr-89 <0.4 <0.9 <0.6 Sr-90 <0.4 0.9+/-0.4 <0.4 H-3 <165 <170 <171 Cs-134 <5.0 <4.2 <3.7 Cs-137 <4.8 <5.0 <3.9 Other Gammasa <4.3 <5.9 <4.7 a See Introduction. b Analysis was repeated at request of Palisades: results of reanalysis P AWW-4449 3.9+/-0.7 P AWW-6023 4.4+/-0.7 4779 4.8+/-0.8 5259 4.8+/-0.4 33 Required LID 4.0 5.0 1.0 500 15.0 18.0 15.0 4.0 5.0 1.0 500 15.0 18.0 15.0
Table7. Well Water (continued) Collection: Monthly Units: pCi/L Location: Site Well #15 PALISADES Sample Description and Concentration Date Collected 07-07-92 08-11-92 09-09-92 Lab Code PAWW-6475 PAWW-6925 PAWW-7269 Gross Beta 6.8+/-0.7b 4.0+/-0.7 5.6+/-0.7b Sr-89 <1.4 <0.9 <1.0 Sr-90 0.9+/-0.4 <0.4 <0.5 H-3 <167 <188 <185 Cs-134 <4.3 <4.3 <6.3 Cs-137 <4.1 <4.1 <6.3 Other Gammasa <4.3 <3.9 <7.4 Date Collected 10-06-92 11-18-92 12-02-92 Lab Code -PAWW-7628 PAWW-8118 PAWW-8354 Gross Beta 7.2+/-0.5b 6.2+/-1.3C 7.6+/-0.9b Sr-89 <1.2 <1.0 <1.1 Sr-90 0.8+/-0.4 <0.5 1.2+/-0.5 H-3 <178 <178 <179 Cs-134 <4.0 <5.9 <4.9 Cs-137 <4.2 <6.7 <5.1 Other Gammasa <3.9 <6.4 <5.0 a See Introduction. b Analysis was repeated; result of reanalysis: c Average of two repeated analysis. PAWW-6475 -7269 6.0+/-0.8 3.5+/-0.6 7.0+/-0.5 6.8+/-0.5 -7628 -8354 34 Required LID 4.0 5.0 1.0 500 15.0 18.0 15.0 4.0 5.0 1.0 500 15.0 18.0 15.0
Table7. Well Water (continued) Collection: Monthly Units: pCi/L Location: Site Well #16 PALISADES Sample Description and Concentration Date Collected 01-14-92 02-05-92 03-04-92 Lab Code PAWW-4183 PAWW-4450 PAWW-4780 Gross Beta b 5.3+/-0.4 4.2+/--0.8b 5.2+/-0.7b Sr-89 <0.7 <0.7 <0.8 Sr-90 <0.5 <0.6 <0.6 H-3 <181 <169 <174 Cs-134 <6.1 <6.1 <6.4 Cs-137 <7.1 <6.6 <6.4 Other Gammasa <7.8 <7.1 <7.8 Date Collected 04-06-92 05-05-92 06-08-92 Lab Code PAWW-5260 PAWW-5630 PAWW-6024 Gross Beta 4.8+/-0.8b 4.5+/-0.9b 4.7+/-0.7b Sr-89 <0.6 <0.9 <0.7 Sr-90 <0.5 . <0.6 <0.5 H-3 95+/-90 <170 <171 Cs-134 <3.5 <4.9 <3.9 Cs-137 <4.0 <4.0 <4.1 Other Gammasa <4.9 <4.7 <4.4 a See Introduction. b Analy~is was repeated at request of Palisades: results of reanalysis P AWW-4183 3.7+/-0.7 PA WW-5630 3.7+/-0.5 4450 4.0+/-0.9 6024 3.6+/-0.4 4780 5.3+/-1.0 5260 3.9+/-0.4 35 Required LID 4.0 5.0 1.0 15.0 18.0 15.0 4.0 5.0 1.0 -- 500 15.0 18.0 15.0
Table 7. Well Water (continued) Collection: Monthly Units: pCi/L Location: Site Well #16 PALISADES Sample Description and Concentration Date Collected 07417-92 08-11-92 09-09-92 Lab Code PAWW-6476 PAWW-6926 PAWW-7270 Gross Beta 5.1:f:0.7b 4.0:tD.7 3.9+/-0.7 Sr-89 <1.7 <1.1 <0.9 Sr-90 <0.7 <0.5 <0.5 H-3 <167 <188 <185 Cs-134 <5.6 <2.1 <4.7 Cs-137 <5.8 <2.1 <5.6 Other Gammasa <5.4 <2.2 <6.2 Date Collected 10416-92 11-21-92 12-02-92 Lab Code PAWW-7629 PAWW-8119,20 PAWW-8355 Gross Beta 4.5+/-0.7 5.3+/-1.ob 4.6+/-0.8 Sr-89 <1.0 <0.9 <1.0 Sr-90 0.6+/-0.3 0.3:W.4 <0.7 H-3 <178 <168 <177 Cs-134 <4.6 <5.9 <3.7 Cs-137 <4.4 <6.0 <4.7 Other Gammasa <4.4 <6.5 <3.8 a See Introduction. b Analysis was repeated; result of reanalysis: PAWW-6476 3.7+/-0.7 -8119,20 5.0+/-1.0 36 Required LID 4.0 5.0 1.0 500 15.0 18.0 15.0 4.0 5.0 1.0 500 15.0 18.0 15.0
Table 8. PALISADES In-Plant Water Collection: Monthly Composite Units: pCi/L Location: Turbine Sump Sample Description and Concentration Collection Period January February. March Lab Code PACW-4452 PACW-4768 PACW-5269 Gross Alpha <0.8 <0.3 <0.5 Gross Beta 20+/-0.5 25+/-0.3 3.6+/-0.3 Sr-89 <0.6 <0.8 <0.8 Sr-90 0.6+/-0.3 <0.6 <0.5 H-3 1466+/-134 1156+/-129 1505+/-133 Cs-137 <2.2 <2.6 <4.0 Other Gammasa <2.2 <3.3 <3.6 Collection Period April May June Lab Code PACW-5669 PACW-6019 PACW-6486 Gross Alpha <0.3 <0.4 1.0+/-0.4 Gross Beta 1.7+/-0.3 0.9+/-0.4 2.0+/-0.6 Sr-89 <1.0 <0.9 '<1.5 Sr-90 <0.6 <0.5 <0.7 H-3 30301+/-337b 9899+/-277 4782+/-204 Cs-137 <3.7 <2.2 <1.8 Other Gammasa <4.0 <2.1 <1.8 a See Introduction. b Analysis was repeated; result of reanalysis 33432+/-1961 pCi/L. 37 Required LID 1.0 1.0 5.0 1.0 500 10 10 1.0 1.0 5.0 1.0 500 10 10
Tables. PALISADES In-Plant Water Collection: Monthly Composite Units: pCi/L Location: Turbine Sump Sample Description and Concentration Collection Period July August September Lab Code PACW-6935 PACW-7277,8 PACW-7635 Gross Alpha 0.5:tD.2 <0.3 O.S:tD.2 Gross Beta 1.4:+/-0.3 1.9+/-0.2 2.6+/-0.3 Sr-89 <1.5 <0.6 <1.0 Sr-90 <0.6 <0.3 <0.5 H-3 3227+/-178 2226+/-110 2115+/-152 Cs-137 <1.3 <2.6 <4.5 Other Gammasa <1.4 <2.7 <4.4 Collection Period October November December Lab Code PACW-8169,70 PACW-8343 PACW-8782 Gross Alpha O.S:tD.1 <0.6 <0.2 Gross Beta 1.3:tD.2 3.7:tD.6 1.0+/-0.2 Sr-89 <1.8 <0.8 <0.9 Sr-90 <0.7 <0.5 <0.8 H-3 2436+/-111 2268+/-152 2375+/-153 Cs-137 <3.3 <4.2 <4.1 Other Gammasa <3.8 <4.4 <4.2 a See Introduction. 38 Required LID 1.0 1.0 5.0 1.0 500 10 10 1.0 1.0 5.0 1.0 500 10 10
Table 8. PALISADES In-Plant Water Collection: Monthly Composite Units: pCi/L Location: Service Water Sample Description and Concentration Collection Period January February March Lab Code PACW-4453 PACW-4769 PACW-5270 Gross Alpha <0.7 <0.5 <0.6 Gross Beta 0.9+/-0.4 21+/-0.3 0.9+/-0.3 Sr-89 <0.8 <0.6 <0.8 Sr-90 <0.6 0.6+/-0.3 <0.5 H-3 120+/-90 <183 97+/-90 Cs-137 <1.9 <2.6 <3.2 Other Gammasa <1.8 <2.6 <3.4 . Collection Period April . May June Lab Code PACW-5624 PACW-6018 PACW-6485 Gross Alpha <0.4 <1.0 <0.7 Gross Beta 25+/-0.3 22+/-0.5 2.9+/-0.6 Sr-89 <1.0 <0.6 <1.1 Sr-90 1.2+/-0.4 0.5+/-0.2 <0.5 H-3 <170 167+/-91 208+/-96 Cs-137 <2.3 <2.1 <2.8 Other Gammasa <2.6 <2.9 <2.6 a See Introduction. 39 Required LID 1.0 1.0 5.0 1.0 500 10 10 1.0 1.0 5.0 1.0 500 10 10
Table 8. PALISADES In-Plant Water Collection: Monthly Composite Units: pCi/L Location: Service Water Sample Description and Concentration Collection Period July August September Lab Code PACW-6934 PACW-7274 PACW-7634 Gross Alpha 0.7:l:0.3 <0.4 <0.4 Gross Beta 2.l:l:0.3 23:l:0.3 2.7:l:0.3 Sr-89 <1.0 <0.9 <0.9 Sr-90 1.0:l:0.4 <0.5 <0.5 H-3 <188 <185 <178 Cs-137 <1.7 <3.3 <2.9 Other Gammasa <2.1 <3.0 <3.0 Collection Period October November December Lab Code PACW-8168 PACW-8346 PACW-8781 Gross Alpha <0.4 <0.4 <0.4 Gross Beta 2.3:l:0.3 23:l:0.3 2.3:l:0.3 Sr-89 <1.8 <1.2 <0.8 Sr-90 .<0.6 <0.5 <0.7 H-3 <175 <166 <164 Cs-137 <4.5 <2.7 <3.7 Other Gammasa <3.7 <3.0 <3.7 a See Introduction. 40 Required LID 1.0 1.0 5.0 1.0 500 10 10 1.0 1.0 5.0 1.0 500 10 10
PALISADES Table9. Milk Collection: Monthly Units: pCi/L Location: GH - Glen Hessey Fann Required Sample Description and Concentration LID Date Collected 01-14-92 02-04-92 ~92 04--07-92 lab Code PAMI-7353 PAMI-7414 PAMI-7483 PAMI-7574 I-131 <0.2 <0.2 <0.2 <0.3 1.0 Sr-89 <0.5 <0.6 <0.5 <0.6 5.0 Sr-90 3.1+/-0.6 26+/-0.5 2.0+/-0.5 3.4+/-0.6 1.0 K-40 1320+/-140 1260+/-110 1220+/-150 1340+/-150 Cs-134 <4.3 <4.4 <6.2 <6.7 15.0 Cs-137 <3.9 <4.7 <8.1 <7.0 18.0 Ba-I.a-140 <4.5 <5.1 <6.0 <8.0 15.0 Date Collected 05-05-92 06-07-92 07-06-92 08-11-92 lab Code PAMI-7662 PAMI-7838 PAMI-8017 PAMI-8243 I-131 <0.3 <0.3 <0.2 <0.5 1.0 Sr-89 <0.5 <1.0 <0.9 <1.6 5.0 Sr-90 2.8+/-0.5 25+/-0.7 2.8+/-0.6 3.8+/-1.2 1.0 K-40 1260+/-130 1390+/-120 1190+/-150 1320+/-100 Cs-134 <5.5 <4.2 <6.8 <4.3 15.0 Cs-137 <5.6 <4.6 <7.2 <4.4 18.0 Ba-I.a-140 <10.8 <7.1 <12.7 <11.3 15.0 Date Collected 09-02-92 10-06-92 11-09-92 12-02-92 lab Code PAMI-8322 PAMI-8534 PAMI-8695 PAMI-8731 I-131 <0.4 <0.4 <0.2 <0.2 1.0 Sr-89 <1.7 <0.9 <0.8 <0.9 5.0 Sr-90 3.4+/-0.9 28+/-0.6 3.4+/-0.6 3.1+/-0.7 1.0 K-40 1290+/-150 1250+/-140 1396+/-120 1380+/-160 Cs-134 <4.4 <4.9 <4.4 <3.6 15.0 Cs-137 <5.2 <5.3 <4.9 <5.3 18.0 Ba-la-140 <7.7 <10.1 <7.7 <7.1 15.0 41
PALISADES Table9. Milk Collection: Monthly Units: pCi/L Location: KK - Kenneth Kemp Farm Required Sample Description and Concentration LID Date Collected 01-13-92 02-03-92 03-04-92 04-07-92 Lab Code PAMI-7355 PAMl-7412,3 P AMI-7479,80 PAMI-7575 1-131 <0.2 <0.2 <0.2 <0.3 1.0 Sr-89 <0.5 <0.6 <0.5 <0.6 5.o-Sr-90 4.8+/-0.7 3.2+/-0.4 2.5+/-0.3 2.9+/-0.7 1.0 K-40 1240+/-140 1300+/-100 1280+/-70 1240+/-150 Cs-134 <6.0 <7.1 <4.1 <6.7 15.0 Cs-137 <7.6 <7.5 <4.2 <8.1 18.0 Ba-La-140 <8.8 <8.2 <5.7 <8.9. 15.0 Date Collected 05-04-92 06-05-92 07-06-92 08-11-92 Lab Code PAMI-7665 PAMI-7835 PAMI-8014 PAMI-8246 I-131 <0.2 <0.3 <0.3 <0.5 1.0 Sr-89 <0.6 <0.8 <0.8 <1.1 5.0 Sr-90 2.8+/-0.6 20+/-0.7 3.0+/-0.6 2.9+/-0.6 1.0 K-40 1270+/-110 1130+/-140 1400+/-160 1170+/-110 Cs-134 <5.2 .<4.6 <6.2 <4.9 15.0 Cs-137 <5.6 <5.7 <7.3 <5.0 18.0 Ba-La-140 <9.8 <10.5 <8.9 <13.4 15.0 Date Collected 09-02-92 10-05-92 11-09-92 12-02-92 Lab Code PAMI-8320 PAMI-8531 PAMI-8693. PAMI-8729 I-131 <0.4 <0.3 <0.2 <0.2 1.0 Sr-89 <1.6 <0.8 <0.9 <0.8 5.0 Sr-90 2.4+/-1.1 23+/-0.6 4.0+/-0.7 2.7+/-0.6 1.0 K-40 1210+/-150 1330+/-130 1287+/-142 1380+/-130 Cs-134 <4.4 <8.4 <3.6 <5.9 15.0 Cs-137 <6.0 <6.1 <5.5 <6.9 18.0 Ba-La-140 <8.6 <9.5 <10.5 <9.7 15.0 42
PALISADES Table9. Milk Collection: Monthly Units: pCi/L Location: WS - William Shine Farm Required Sample Description and Concentration LLD Date Collected 01-14-92 02-04-92 03--04-92 04-07-92 lab Code PAMI-7352 PAMI-7415 PAMI-7482 PAMI-7572 1-131 <0.2 <0.2 <0.2 <0.3 1.0 Sr-89 <0.5 <0.8 <0.6 <0.5 5.0 Sr-90 2.4+/-0.5 20+/-0.5 24+/-0.5 1.5+/-0.5 1.0 K-40 1220+/-140 1300+/-160 1240+/-110 1390+/-140 Cs-134 <5.0 <5.3 <4.8 <4.9 15.0 Cs-137 <5.1 <5.2 <4.7 <6.0 18.0 Ba-La-140 <4.6 <6.0 <5.6 <4.7 15.0 Date Collected 05-05-92 06-07-92 07-06-92 08-11-92 lab Code PAMl-7663 PAMI-7837 PAMl-8016 PAMI-8244 I-131 <0.2 <0.3 <0.3 <0.4 1.0 Sr-89 <0.5 <0.9 <1.3 <0.9 5.0 Sr-90 1.5+/-0.4 23f0.8 2.0+/-0.8 25+/-0.7 1.0 K-40 1140+/-150 1360+/-110 1200+/-150 1380+/-120 Cs-134 <7.0 <5.0 <6.7 <5.3 15.0 Cs-137 <6.5 <4.8 <7.0 <6.4 18.0 Ba-La-140 <13.8 <7.8 <7.1 <14.0 15.0 Date Collected 09-02-92 1CH)6-92 11-09-92 12-02-92 lab Code PAMI-8321 PAMI-8533 PAMI-8694 PAMI-8730 1-131 <0.4 <0.4 <0.2 <0.2 1.0 Sr-89 <0.8 <0.9 <1.2 <0.8 5.0 Sr-90 3.1+/-0.7 1.8f0.5 2.9+/-0.6 27+/-0.6 1.0 K-40 1180+/-140 1190+/-140 1417+/-107 1420+/-160 Cs-134 <5.5 <4.2 <4.0 <4.2 15.0 Cs-137 <5.6 <5.5 <4.8 <5.6 18.0 Ba-La-140 <11.7 <8.1. <9.5 <7.0 15.0 43
PALISADES Table 9. Milk Collection: Monthly Units: pCi/L Location: FC - Frank Crnkovich Farm Required Sample Description and Concentration LID Date Collected 01-14-92 02-04-92 03-04-92 04-07-92 Lab Code PAMI-7354 PAMI-7416 PAMl-7481 PAMI-7573 1-131 <0.2 <0'.2 <0.3 <0.3 1.0 Sr-89 <0.5 <0.7 <0.8 <0.5 5.0 Sr-90 3.9+/-0.6 3.5+/-0.5 2.3+/-0.5 2.4+/-0.5 1.0 K-40 1280+/-100 1180+/-120 1120+/-130 1160+/-100 Cs-134 <3.4 <5.2 <4.5 <4.6 15.0 Cs-137 <4.6 <5.6 <5.4 <4.4 18.0 Ba-La-140 <4.0 <5.7 <4.9 <3.9 15.0 Date Collected 05-05-92 06-07-92 07-06-92 08-11-92 Lab Code PAMI-7664 PAMI-7836 PAMI-8015 PAMI-8245 1-131 <0.2 <0.3 <0.2 <0.5 1.0 Sr-89 <0.6 <0.8 <0.8 <1.0 5.0 Sr-90 2.2+/-0.5 3.5+/-1.0 4.0+/-0.6 2.9+/-0.7 1.0 K-40 1160+/-120 1300+/-110 1440+/-160 1340+/-50 Cs-134 <5.6 <3.8 <6.8 <1.6 15.0 Cs-137 <5.6 <4.4 <6.9 <1.8* 18.0 Ba-La-140 <8.6 <6.7 <10.7 <10.7 15.0 Date Collected 09-02-92 10-06-92 11-09-92 12-02-92 Lab Code PAMI-8323 PAMI-8532 PAMI-8696 PAMI-8732 1-131 <0.4 <0.3 <0.2 <0.2 1.0 Sr-89 <1.1 <0.9 <0.8 <0.6 5.0 Sr-90 3.8+/-1.1 3.4+/-0.8 6.3+/-0.8 5.6+/-0.8 1.0 K-40 1020+/-140 1410+/-160 1006+/-121 1560+/-130 Cs-134 <4.4 <6.4 <3.6 <3.8 15.0 Cs-137 <5.8 <6.9 <5.0 <5.1 18.0 Ba-La-140 <6.0 <11.0 <7.7 <4.3 15.0 44
PALISADES Table 10. Food Crops. Collection: Semiannually at time of harvest. Units: pCi/g wet Required Sample Description and Concentration UD Location Jerry Samo Jerry Samo Jerry Samo Jerry Samo Farm Farm Farm Farm Date Collected 08-24-92 08-24-92 08-24-92 08-24-92 Sample Collected Peaches Pears Apples Plums Lab Code PAVE-1422 PAVE-1423 PAVE-1424 PAVE-1425 Gross Beta 1.43+/-0.06 0.99+/-0.04 0.62+/-0.02 1.60+/-0.07 1.0 Sr-89 <0.002 <0.001 <0.001 <0.003 0.025 Sr-90 0.002+/-0.001 <0.001 0.002+/-0.001 <0.002 0.005 1-131 <0.031 <0.019 <0.028 <0.026 0.06 Mn-54 <0.016 <0.012 <0.019 <0.014 0.08 Co-58 <0.018 <0.013 <0.018 <0.014 0.08 Co-60 <0.015 <0.012 <0.021 <0.013 0.05 Fe-59 <0.038 <0.036 <0.041 <0.028 0.1 Zn-65 <0.043 <0.026 <0.042 <0.028 0.1 Zr-Nb-95 <0.030 <0.019 <0.026 <0.023 0.1 Cs-134 <0.018 <0.010 <0.013 <0.014 0.08 Cs-137 <0.017 <0.012 <0.015 <0.012 0.08 Ba-La-140 <0.022 <0.011 <0.028 <0.016 0.1 Location Jerry Samo Paul Rood Paul Rood Paul Rood Farm Farm Farm Farm Date Collected 08-26-92 09-09-92 09-15-92 09-15-92 Sample Collected Blueberries Blueberries Apples Plums Lab Code PAVE-1468 PAVE-1478 PAVE-1479 PAVE-1480 Gross Beta 0.68+/-0.02 0.67+/-0.03 0.35+/-0.02 1.57+/-0.06 1.0 Sr-89 <0.002 <0.003 <0.004 <0.002 0.025 Sr-90 0.003+/-0.001 0.004+/-0.001 <0.001 <0.001 0.005 1-131 <0.033 <0.059 <0.056 <0.039 0.06 Mn-54 <0.008 <0.008 <0.010 <0.012 0.08 Co-58 <0.009 <0.008 <0.012 <0.012 0.08 Co-60 <0.007 <0.007 <0.010 <0.017 0.05 Fe-59 <0.020 <0.022 <0.027 <0.030 0.1 Zn-65 <0.016 <0.016 <0.024 <0.032 0.1 Zr-Nb-95 <0.016 <0.015 <0.020 <0.024 0.1 Cs-134 <0.006 <0.005 <0.011 <0.011 0.08 Cs-137 <0.008 <0.007 <0.010 <0.012 0.08 Ba-La-140 <0.020 <0.015 <0.027 <0.039 0.1 45
PALISADES Table 10. Food Crops. Collection: Semiannually at time of harvest. Units: pCi/ g wet Sample Description and *concentration Location Date Collected Sample Collected Lab Code Gross Beta Sr-89
- Sr-90 1-131 Mn-54 Co-58 Co-60 Fe-59 Zn-65 Zr-Nb-95 Cs-134 Cs-137 Ba-La-140 Location Date Collected Sample Collected Lab Code Gross Beta Sr-89 Sr-90 1-131 Mn-54 Co-58 Co-60 Fe-59 Zn-65 Zr-Nb-95 Cs-134 Cs-137 Ba-La-140 Paul Rood Farm 09-15-92 Pears PAVE-1481,2 0.88+/-0.02
<0.003a 0.002+/-0.001 a <0.054 <0.008 <0.010 <0.008 <0.029 <0.018 <0.017 <0.006 <0.007 <0.034 NOTE: Page 47 is intentionally left out. Jerry Samo Farm 10-06-92 Grapes PAVE-1511 1.77+/-0.08 <0.002 0.003+/-0.001 <0.015 <0.014 <0.013 <0.016 <0.035 <0.039 <0.026 <0.012 <0.014 <0.021 a Result of single analysis; not enough sample to duplicate. 46 Req~ed. 1.0 0.025 0.005 0.06 0.08 0.08 0.05 0.1 0.1 0.1 0.08 0.08 0.1 1.0 0.025 0.005 0.06 0.08 0.08 0.05 0.1 0.1 0.1 0.08 0.08 0.1
- PALISADES FISh Collection: Semiannually Units: pCi/ g wet Sample Description and Concentration Required LLD Location Ludington Pumped Storage Plant (Control)
Date Collected 07-28-92 07-28-92 07-28-92 07-28-92 07-28-92 Sample Type Shiners Sucker Alewives Brown Trout Perch Lab Code PAF-1830 PAF-1831 PAF-1832 PAF-1833 PAF-1834 Gross Beta 217+/-0.12 2.99+/-0.11 2.41+/-0.12 3.00+/-0.09 1.57+/-0.13 1.0 Sr-89 <0.006 <0.008 <0.002 <0.007 <0.007 0.025 Sr-90 0.007+/-0.002 <0.004 <0.001 <0.003 0.007+/-0.002 0.005 Mn-54 <0.012 <0.016 <0.017 <0.014 <0.020 0.13 Co-58 <0.023 <0.030 <0.027 <0.026 <0.030 0.13 Co-60 <0.011 <0.016 <0.016 <0.009 <0.020 0.13 Fe-59 <0.072 <0.094 <0.094 <0.11 <0.12 0.26 Zn-65 <0.039 <0.049 <0.045 <0.037 <0.049 0.26
- -Nb-95
<0.050 <0.053 <0.054 <0.041 <0.062 0.1 -134 <0.012 <0.015 <0.018 <0.011 <0.015 0.13 Cs-137 <0.010 <0.014 <0.015 0.058+/-0.019 0.035+/-0.015 0.15 Ba-La-140 <0.012a <0.013a <0.013a <0.011a <0.016a 0.1 Location Ludington Pumped Storage Plant (Control) Date Collected 07-28-92 11-06-92 11-06-92 11-06-92 11-06-92 Sample Type Perch Rainbow Trout Rainbow Trout Sucker Brown Trout Lab Code PAF-1835,6 PAF-1958 PAF-1959 PAF-1960 PAF-1961,2 Gross Beta 3.13+/-0.10 2.83+/-0.10 3.81+/-0.12 2.71+/-0.10 3.77+/-0.11 1.0 Sr-89 <0.oosb <0.006 <0.004 <0.005 <O.oosh 0.025 Sr-90 0.008+/-0.003b <0.002 <0.002 <0.002 <0.002b 0.005 Mn-54 <0.019 <0.009 <0.025 <0.007 <0.006 0.13 Co-58 <0.026 <0.011 <0.030 <0.010 <0.007 0.13 Co-60 <0.015 <0.010 <0.023 <0.008 <0.007 0.13 Fe-59 <0.10 <0.035 <0.080 <0.028 <0.022 0.26 Zn-65 <0.037 <0.023 <0.054 <0.020 <0.016 0.26 Zr-Nb-95 <0.049 <0.022 <0.060 <0.017 <0.014 0.1 Cs-134 <0.013 <0.008 <0.020 <0.007 <0.006 0.13 Cs-137 0.070+/-0.013 0.040+/-0.006 <0.021 0.014+/-0.005 0.075+/-0.016 0.15 -La-140 <0.01oa <0.087 <0.1 <0.073 <0.052 0.1 a LLD at time of counting. b Result of single analysis; not enough sample to duplicate. 48
PALISADES Table 11. Fish (continued) Sample Description and Concentration Required LLD Location Palisades Discharge Date Collected 07-15-92 07-15-92 07-15-92 Sample Type Carp Steelhead Shad Lab Code PAF-1799 PAF-1800 PAF-1801 Gross Beta 2.05+/-0.07 1.82+/-0.08 2.08+/-0.10 1.0 Sr-89 <0.007 <0.008 <0.014 0.025 Sr-90 <0.003 <0.004 <0.005 0.005 Mn-54 <0.026 <0.020 <0.030 0.13 Co-58 <0.025 <0.030 <0.037 0.13 Co-60 <0.028 <0.028 <0.035 0.13 Fe-59 <0.087 <0.074 <0.095 0.26 Zn-65 <0.072 <0.064 <0.060 0.26 Zr-Nb-95 <0.050 <0.048 <0.032 Cs-134 <0.023 <0.020 <0.026 Cs-137 <0.031 0.052+/-0.018 <0.030 Ba-La-140 <0.067 <0.10 <0.049 Location Palisades Discharge Date Collected 07-15-92 07-15-92
- 07-15-92 Sample Type Sucker Freshwater Drum Shiners Lab Code PAF-1802 PAF-1803 PAF-1804 Gross Beta 2.40+/-0.09 231+/-0.09 1.92+/-0.10 1.0 Sr-89
<0.012 <0.006 <0.020 0.025 Sr-90 <0.005 <0.002 0.007+/-0.005 0.005 Mn-54 <0.028 <0.022 <0.023 0.13 Co-58 <0.033 <0~026 <0.029 0.13 Co-60
- ~0.040
<0.028 <0.023 0.13 Fe-59 <0.083 <0.083 <0.062 0.26 Zn-65 <0.065 <0.056 <0.053 0.26 Zr-Nb-95 <0.060 <0.041 <0.047 0.1 Cs-134 <0.028 <0.021 <0.020 0.13 Cs-137 <0.027 <0.027 <0.020 0.15 Ba-La-140 <0.053 <0.10 <0.098 It NOTE: Page 50 is intentionally left out. 49
PALISADES ble 11. Fish (continued) Sample Description and Concentration Required LLD Location Palisades Discharge Date Collected 10-28-92 10-28-92 10-28-92 10-28-92 Sample Type Lake Trout White Sucker Steelhead Coho Salmon Lab Code PAF-1947 PAF-1948 PAF-1949 PAF-1950 Gross Beta 2.86+/-{).10 2.52+/-0.09 2.90+/-0.13 2.79+/-0.09 1.0 Sr-89 <0.012 <0.003 <0.004 <0.004 0.025 Sr-90 0.007+/-0.004 <0.004 <0.003 <0.002 0.005 Mn-54 <0.009 <0.010 <0.008 <0.007 0.13 Co-58 <0.011 <0.012 <0.010 <0.009 0.13 Co-60 <0.010 <0.010 <0.008 <0.007 0.13 Fe-59 <0.028 <0.029 <0.026 <0.022 0.26 Zn-65 <0.026 <0.028 <0.021 <0.020 0.26
- -Nb-95
<0.021 <0.020 <0.018 <0.016 0.1 ,-134 <0.009 <0.008 <0.008 <0.008 0.13 ~-137 0.082+/-0.009 <0.009 0.050+/-0;006 0.057+/-0.006 0.15 Ba-La-140 <0.029 <0.031 <0.027 <0.020 0.1 Date Collected 10-28-92 Sample Type Walleye Lab Code PAF-1951 Gross Beta 0.93+/-0.06 1.0 Sr-89 <0.006 0.025 Sr-90 0.004+/-0.002 0.005 Mn-54 <0.016 0.13 Co-58 <0.019 0.13 Co-60 <0.017 0.13 Fe-59 <0.043 0.26 Zn-65 <0.043 0.26 Zr-Nb-95 <0.033 0.1 Cs-134 <0.018 0.13 Cs-137 <0.016 0.15 aa-La-140 <0.048 0.1 50
Table 12. Algae Collection: Semiannually Units : pCi/ g wet PALISADES Sample Description and Concentration Location Date Collected Lab Code Gross Beta Sr-89 Sr-90 Mn-54. Co-58 Co-60 Fe-59 Zn-65 Zr-Nb-95 .Cs-134 Cs-137 Ba-La-140 Location Date Collected Lab Code Gross Beta Sr-89 Sr-90 Mn-54 Co-58 Co-60 Fe-59 Zn-65 Zr-Nb-95 Cs-134 Cs-137 Ba-La-140 a LLD at time of counting. 07-28-92 PASL-338 3.88+/-0.44 <0.018 <0.005 <0.021 <0.022 <0.020 <0.055 <0.050 <0.041 <0.018 <0.018 <0.058 Ludington (Control) 11-05-92 PASL-363 1.30+/-0.13 <0.008 0.0087+/-0.0024 Palisades Discharge 51 <0.031 <0.039 <0.034 <0.093 <0.071 <0.056 <0.028 <0.029 <0.032a Required LLD 1.0 0.025 0.005 0.13 . 0.13 0.13 0.26 0.26 0.1 0.13 0.15 0.1 1.0 0.025 0.005 0.13 0.13 0.13 0.26 0.26 0.1 0.13 0.15 0.1
PALISADES able 13. Bottom Sediments Collection: Semiannually Units: pCi/ g dry Sample Description and Concentration Required LLD Location Ludin&ton (Control) Date Collected 07-28-92 11-06-92 11-06-92 Lab Code PABS-1167 PABS-1245 PABS-1246 Gross Beta 4.64+/-271 12.06+/-1.38 11.84+/-1.46 1.0 Sr-89 <0.008 <0.011 <0.010 0.025 Sr-90 <0.004 <0.004 <0.005 0.005 ~vfa-54 <0.007 <0.014 <0.011 0.08 Co-58 <0.010 <0.018 <0.016 0.08 Co-60 <0.009 <0.018 <0.014 0.05 Fe-59 <0.029 <0.054 <0.045 0.1 Zn-65 <0.017 <0.033 <0.028 0.1 -Nb-95 <0.017 <0.033 <0.030 0.1 -134 <0.005 <0.011 <0.009 0.15 ~-137 0.12+/-0.008 0.025+/-0.012 0.029+/-0.009 0.18 Ba-La-140 <0.045 <0.099 <0.083 0.1 Location South Haven Date Collected 07-15-92 10-28-92 Lab Code PABS-1153 PAB5-1226 Gross Beta 7.78+/-1.43 8.49+/-1.77 1.0 Sr-89 <0.012 <0.012 0.025 Sr-90 <0.004 <0.004 0.005 Mn-54 <0.CXl6 <0.007 0.08 Co-58 <0.009 <0.008 0.08 Co-60 <0.008 <0.010 0.05 Fe-59 <0.032 <0.024 0.1 Zn-65 <0.018 <0.020 0.1 Zr-Nb-95 <0.018 <0.015 0.1 Cs-134 <0.005 <0.007 0.15 Cs-137 0.019+/-0.005 <0.006 0.18 Ba-La-140 <0.093 <0.051 0.1 52
PALISADFS Table 13. Bottom Sediments (continued) Sample Description and Concentration Required LLD Location South Property (0.8 ml) Date Collected 07-15-92 10-28-92 Lab Code PABS-1155 PABS-1228 Gross Beta 3.8+/-1.6 5.12+/-1.72 1.0 Sr-89 <O.OO'J <0.009 0.025 Sr-90 <0.004 <0.004 0.005 Mn-54 <0.016 <0.006 0.08 Co-58 <0.020 <0.007 0.08 Co-60 <0.018 <0.007 0.05 Fe-59 <0.056 <0.016 0.1 Zn-65 <0.032 <0.013 0.1 Zr-Nb-95 <0.036 <0.013 0.1 Cs-134 <0.012 <0.004 0.15 Cs-137 0.026+/-0.013 0.019+/-0.006 0.18 Ba-La-140 <0.10 <0.021 0.1 Location North Property (0.8 mi.) Date Collected 07-15-92 10-28-92 Lab Code PABS-1154 PABS-1227 Gross Beta 5.57+/-1.31 6.21+/-1.29 1.0 Sr-89 <0.013 <0.012 0.025 Sr-90 <0.004 <0.005 0.005 Mn-54 <0.004 <0.008 0.08 Co-58 <0.006 <0.010 0.08 Co-60 <0.005 <0.010 0.05 Fe-59 <0.021 <0.026 0.1 Zn-65 <0.010 <0.020 0.1 Zr-Nb-95 <0.011 <0.016 0.1 Cs-134 <0.003 <0.006 0.15 Cs-137 0.012+/-0.005 0.020+/-0.007 0.18 Ba-La-140 <0.081 <0.026 0.1 53
PALISADES .able13. Bottom Sediments (continued) Location Date Collected Lab Code Gross Beta Sr-89 Sr-90 Mn-54 Co-58 Co-60 Fe-59 Zn-65 Zr-Nb-95 Cs-134 -137 a-La-140 Location Date Collected Sample Type Lab Code Gross Beta Sr-89 Sr-90 Mn-54 Co-58 Co-60 Fe-59 Zn-65 Zr-Nb-95 Cs-134 Cs-137 Ba-La-140 Sample Descrtiption and Concentration Palisades Dischar~e 07-15-92 10-28-92 PABS-1156,7 PABS-1229 5.08+/-0.84. 6.96+/-0.87 <0.013 <0.014 <0.004 <0.005 <0.004 <0.005 <0.007 <0.006 <0.005 <0.007 <0.022 <0.015 <0.013 <0.015 <0.013 <0.011 <0.005 <0.007 0.014+/-0.003 0.017+/-0.003 <0.087 <0.036 54 Required LLD 1.0 0.025 0.005 0.08 0.08 0.05 0.1 0.1 0.1 0.15 0.18 0.1 1.0 0.025 0.005 0.08 0.08 0.05 0.1 0.1 0.1 0.15 0.18 0.1
PALISADES Table 14.1. Llquid Radwaste Collection: Monthly Composite Units: µCi/ml, except Pu-239 (pCi/L) Sample Description and Concentration Collection Period January February Lab Code Nsa NS Gross alpha Sr-89 Sr-90 H-3 Pu-239 Cr-51 Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-95 Nb-95 Ag-110m Sb-124 Cs-134 Cs-137 Ba-140 La-140 Ce-141 Ce-144 a NS = no sample;* sample not collected. 55 March PARW-444 <1.1 E-09 6.8+/-2.4 E-09 2.8+/-0.8 E--09 4.0 E-02 <0.2 <6.4 E--08 3.6+/-0.1 E-07 * <1.6 E--08 1.3+/-0.l E-07 4.6+/-0.1 E-07 <1.5 E-08 <1.3 E--08 <8.3 E-09 4.3+/-0.6 E--08 <7.3 E-09 1.1+/-0.6. E--08 3.2+/-0.1 E-07 <3.8 E--08 <5.8 E-09 <1.3 E--08 <4.6 E--08
PALISADES Table 14.1.. Liquid Radwaste (continued) Sample Description and Concentration Collection Period April May June Lab Code PARW-446 Nsa PARW-461 Gross alpha <0.6 E-09 <1.1 E-09 Sr-89 <3.1 E-09 <1.3 E-09 Sr-90 3.4+/-1.3 E-09 9.3+/-1.7 E-Q9 H-3 2.0+/-0.1 E--05 1.1+/-0.1 E--01 Pu-239 <0.1 <0.1 Cr-51 <6.3 E--08 <1.7 E--07 Mn-54 2.4+/-0.1 E--07 6.8+/-0.2 E--07 Fe-59 <1.5 E--08 <3.6 E--08 Co-58 <7.3 E-09 1.5+/-0.1 E--06 Co-60 2.2+/-0.1 E--07 1.2+/-0.1 E--06 Zn-65 <1.1 E--08 <25 E-08 Zr-95 <1.1 E--08 <24 E--08 Nb-95 <7.8 E-09 <1.7 E--08 Ag-110m <5.4 E-09 <3.2 E-08 Sb-124 <8.4 E-09 <1.7 E--08 Cs-134 <4.8 E-09 1.4+/-0.1 E--07 Cs-137 1.4+/-0.4 E--08 1.7+/-0.1 E--06 Ba-140 <4.6 E--08 <2.2 E--07 La-140 <7.6 E-09 <2.8 E-08 Ce-141 <1.3 E--08 <24 E--08 Ce-144 <4.1 E--08 <5.6 E-08 a NS = no 5ample; sample not collected. 56
PALISADES Table 14.1 Liquid Radwaste (continued) Sample Description and Concentration Collection Period Lab Code Gross alpha Sr-89 Sr-90 H-3 Pu-239 Cr-51 Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-95 Nb-95 Ag-110m Sb-124 Cs-134 Cs-137 Ba-140 La-140 Ce-141 Ce-144 July a NS= no sample; sample not collected. August 57 September
PALISADES Table 14.1 Liquid Radwaste (continued) Sample Description and Concentration Collection Period lab Code Gross alpha Sr-89 Sr-90 H-3 Pu-239 Cr-51 Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-95 Nb-95 Ag-110m Sb-124 Cs-134 Cs-137 Ba-140 la-140 Ce-141 Ce-144 October a NS= no sample; sample not collected. November 58 December PARW-485 <1.3 E-09 <1.7 E-09 1.3+/-0.2 E-09 1.5+/-0.1 E-01 <0.3 <8.4 E-08 3.2+/-1.0 E-08 <22 E-08 6.5+/-0.2 E-07 8.8+/-2.3 E-07 <2.2 E-08 <1.6 E-08 <1.0 E-08 1.6+/-0.9 E-08 <1.3 E-08 1.5+/-0.1 E-07 20+/-0.3 E-06 <5.9 E-08 <1.0 E-08 <1.2 E-08 <4.4 E-08
PALISADES Table 14.2 Stack Filters Collection: Monthly Composite Units: pCi/ composite 1992 Collection Gross Period Lab Code Alpha Sr-89 Sr-90 Pu-239 January PASP-436 10.7+/-1.1 3.2+/-2.4 <1.8 <0.5 February 439 23+/-0.6 <2.7 4.6+/-1.5 <0.2 March 445 7.9+/-1.2 <5.7 <3.8 <0.9 April 447 3.8+/-0.6 <4.5 7.0+/-2.1 <0.2 May 455 4.2+/-1.0 <6.0 <4.0 <0.1 June 460 1.9+/-0.5 <3.6 <3.6 <0.3 July 464 28+/-0.6 <4.0 5.6+/-1.8 <0.1 August 465 1.7+/-0.5 <2.9 <2.3 <0.1 September 470 25+/-0.6 9.3+/-5.5 <2.4 <0.3 October 477 22+/-0.5 3.4+/-2.9 <1.9 <0.3 November 479 1.5+/-0.5 18.0+/-4.9 5.9+/-1.8 <0.2 December 484 24:W.5 <2.2 <1.9 <0.2 59
Palisades Table 14.3. Special Samples - NRC Split Samples Units: Strontium - pCi/L Fe-55 - pCi/mL Tritium -pCi/mL Sample Description Collection Date Lab Code Sr-89 T-91 Table 14.4. Special Samples - Reactor Water Units: uCi/ mL Collection Description Date Lab Code Sr-89 E-BarPCS 05-28-92 456 <1.0 11-30-92 480 8.7+/-1.8 Table 14.5. Special Samples - Steam Generator Blowdown Units: pCi/L Sample Description Hot Well A SIG+ BS/G Hot Well A S/G + BS/G Collection Date Lab Code Gross Alpha 60 E-06 E-06 Sr-89 Sr-90 Sr-90 <7.0 E-07 3.6+/-0.7 E-07 Sr-90
APPENDIX A INTERLABORA TORY COMPARISON PROGRAM RESULTS NOTE: TIML participates in intercomparison studies administered by U.S. EPA Environmental Monitoring Systems Laboratory, Las Vegas, Nevada. The results are reported in Appendix A. Also reported are results of in-house spikes and blanks. Appendix A is updated twice a year; the complete Appendix is included in January and July monthly reports only. Please refer to January and July reports for information. January, 1993
Appendix A Interlaborator:y Comparison Program Results Teledyne Isotopes Midwest Laboratory (formerly Hazleton Environmental Sciences) has participated* in interlaboratory comparison (crosscheck) programs ~ince the formulation of its quality control program in December 1971. These programs are operated by agencies which supply environmental-type samples (e.g., milk or water) containing concentrations of radionuclides known to the issuing agency but not to participant laboratories. The purpose of such a program is to provide an independent check on the laboratory's analytical procedures and to alert it to any possible problems. Participant laboratories measure the concentration of specified radionuclides and report them to the issuing agency. Several months later, the agency reports the known values to the participant laboratories and specifies control limits. Results consistently higher or lower than the known values or outside the control limits indicate a need to check the instruments or procedures used. The results in Table A-1 were obtained through participation in the environmental sample crosscheck program for milk, water, air filters, and food samples during the period January 1988 through December 1992. This program has been conducted by the U.S. Environmental Protection Agency Intercomparison and Calibration Section, Quality Assurance Branch, Environmental Monitoring and Support Laboratory, Las Vegas, Nevada. I The results in Table A-2 were obtained for thermoluminescent dosimeters (TLDs) during the period 1976, 1977, 1979, 1980, 1984, and 1985-86 through participation in the Second, Third, Fourth, Fifth,, Seventh, and Eighth International Intercomparison of Environmental Dosimeters under the sponsorships listed in Table A-2. Also Teledyne testing results are listed. Table A-3 lists results of the analyses on in-house spiked samples. Table A-4 lists results of the analyses on in-house "blank" samples. Attachment B lists acceptance criteria for "spiked" samples. Addendum to Appendix A provides explanation for out-of-limit results. A-2
Table A-1. U.S. Environmental Protection Agency's crosscheck program, comparison of EPA and Teledyne Isotopes Midwest Laboratory results for milk, water, air filters, and food samples, 1988 through 1992.a Concentration in ~iLLb lab Sample Date TIML Result EPA Resultd Code Type Collected Analysis +/-2oC ls, N=l Control Limits STW-521 Water Jan 1988 Sr-89 27.3+/-5.0 30.0+/-5.0 21.3-38.7 Sr-90 15.3+/-1.2 15.0+/-1.5 12.4-17.6 STW-523 Water. Jan 1988 Gr. alpha 23+/-1.2 4.0+/-5.0 0.0-127 Gr. beta 7.7+/-1.2 8.0+/-5.0 0.0-16.7 STF-524 Food Jan 1988 Sr-89 44.0+/-4.0 46.0+/-5.0 37.3-54.7 Sr-90 53.0+/-2.0 55.0+/-2.8 50.2-59.8 I-131 102.3+/-4.2 102.0+/-10.2 84.3-119.7 Cs-137 95.7+/-6.4 91.0+/-5.0 82.3-99.7 K 1011+/-158 1230+/-62 1124-1336 STW-525 Water Feb 1988 Co-60 69.3+/-23 69.0+/-5.0 60.3-77.7 Zn-65 99.0+/-3.4 94.0+/-9.4 77.7-110.3 Ru-106 92.7+/-14.4 105.0+/-10.5 86.8-123.2 Cs-134 61.7+/-8.0 64.0+/-5.0 55.3-72.7 Cs-137 99.7+/-3.0 94.0+/-5.0 85.3-102.7 STW-526 Water Feb 1988 H-3 3453+/-103 3327+/-362 2700-3954 STW-527 Water Feb 1988 Uranium 3.0+/-0.0 3.0+/-6.0 0.0-13.4 STM-528 Milk Feb 1988 1-131 4.7+/-1.2 4.0+/-0.4 3.3-4.7 STW-529 Water Mar1988 Ra-226 7.1+/-0.6 7.6+/-1.1 5.6-9.6 Ra-228 NAe 7.7+/-1.2 5.7-9.7 STW-530 Water Mar 1988 Gr. alpha 4.3+/-1.2 6.0+/-5.0 0.0-14.7 Gr. beta 13.3+/-1.3 13.0+/-5.0 4.3-21.7 STAF-531 Air Filter Mar 1988 Gr. alpha 21.0+/-2.0 20.0+/-5.0 11.3-28.7 Gr. beta 48.0+/-0.0 50.0+/-5.0 41.3-58.7 . Sr-90 16.7+/-1.2 17.0+/-1.5 14.4-19.6 Cs-137 18.7+/-1.3 16.0+/-5.0 7.3-24.7 STW-532 Water Apr1988 1-131 9.0+/-2.0 7.5+/-0.8 6.2-8.8 A-3
Table A-1. (continued) Concentration in ~iLLb Lab Sample Date TIML Result EPA Resultd Code Type Collected Analysis +/-2oC ls, N=l Control Limits STW-533 Water Apr1988 534 (Blind) Sample A Gr. alpha MY .46.0+/-11.0 27.0-65.0 Ra-226 ND 6.4+/-1.0 4.7-8.1 Ra-228 ND 5.6+/-0.8 4.2-7.0 Uranium 6.0+/-6.0 6.0+/-6.0 0.0-16.4 Sample B Gr. beta ND 57.0+/-5.0 48.3-65.7 Sr-89 3.3+/-1.2 5.0+/-5.0 0.0-13.7 Sr-90 5.3+/-1.2 5.0+/-1.5 2.4-7.6 Co-60 63.3+/-1.3 50.0+/-5.0 41.3-58.7. Cs-134 7.7+/-1.2 7.0+/-5.0 0.0-15.7 Cs-137 8.3+/-1.2 7.0+/-5.0 0.0-15.7 STU-535 Urine Apr1988 H-3 6483+/-155 6202+/-620 5128-7276 STW-536 Water Apr1988 Sr-89 14.7+/-1.3 20.0+/-5.0 11.3-28.7 Sr-90 20.0+2.0 20.0+/-1.5 17.4-22.6 STW-538 Water Jun 1988 Cr-51 331.7+/-13.0 302.0+/-30.0 250.0-354.0 Co-60 16.0+/-2.0 15.0+/-5.0 6.3-23.7 Zn-65 107.7+/-11.4 101.0+/-10.0 . 83.7-118.3 Ru-106 191.3+/-11.0 195.0+/-20.0 60.4-229.6 Cs-134 18.3+/-4.6 20.0+/-5.0 11.3-28.7 Cs-137 26.3+/-1.2 25.0+/-5.0 16.3-33.7 STW-539 Water Jun 1988 H-3
- 5586+/-92 5565+/-557 4600-6530 STM-541 Milk Jun 1988 Sr-89 33.7+/-11.4 40.0+/-5.0 31.3-48.7 Sr-90 55.3+/-5.8 60.0+/-3.0 54.8-65.2 I-131 103.7+/-3.1 94.0+/-9.0.
78.4-109.6 Cs-137 527+/-3.1 51.0+/-5.0 42.3-59.7 K 1587+/-23 1600+/-80 1461-1739 STW-542 Water Jul 1988 Gr. alpha 8.7+/-4.2 15.0+/-5.0 6.3-23.7 Gr. beta 5.3+/-1.2 4.0+/-5.0 0.0-127 STF-543 Food Jul 1988 Sr-89 MY 33.0+/-5.0 24.3-41.7 Sr-90 ND 34.0+/-2.0 30.5-37.5 1-131 115.0+/-5.3 107.0+/-11.0 88.0-126.0 Cs-137 527+/-6.4 49.0+/-5.0 40.3-57.7 K 1190+/-66 1240+/-62 1133-1347 A-4
Table A-1. (continued) Concentration in ~iLLb Lab Sample Date TIML Result EPA Resultd Code Type Collected Analysis +/-2oC ls, N=l Control Limits STW-544
- Water Aug 1988 1-131 80.0+/--0.0 76.0+/-8.0 62.1-89.9 STW-545 Water Aug 1988 Pu-239 11.0+/-0.2 10.2+/-1.0 8.5-11.9 STW-546 Water Aug 1988 Uranium 6.0+/-0.0 6.0+/-6.0 0.0-16.4 STAF-547 Air Filter Aug 1988 Gr. alpha 8.0+/-0.0 8.0+/-5.0 0.0-16.7 Gr. beta 26.3+/-1.2 29.0+/-5.0 20.3-37.7 Sr-90 8.0+/-2.0 8.0+/-1.5 5.~10.6 Cs-137 13.0+/-2.0 120+/-5.0 3.3-20.7 STW-548 Water Sep 1988 Ra-226 9.3+/-0.5 8.4+/-26 6.2-10.6 F.a-228 5.8+/-0.4 5.4+/-1.6 4.0-6.8 STW-549 Water Sep 1988 Gr. alpha 7.0+/-2.0 8.0+/-5.0 0.0-16.7 Gr. beta 11.3+/-1.2 10.0+/-5.0 1.3-18.7 STW-550 Water Oct 1988 Cr-51 252.0+/-14.0 251.0+/-25.0 207.7-294.3 Co-60 26.0+/-2.0 25.0+/-5.0 16.3-33.7 Zn-65 158.3+/-10.2 151.0+/-15.0 125.0-177.0 Ru-106 153.0+/-9.2 152.0+/-15.0 126.0-178.0 Cs-134 28.7+/-5.0 25.0+/-5.0 16.3-33.7 Cs-137 16.3+/-1.2 15.0+/-5.0 6.3-23.7 STW-551 Water Oct 1988 H-3 2333+/-127 2316+/-350 1710-'1.927 STW-552 Water Oct 1988 553 (Blind)
Sample A Gr. alpha 38.3+/-8.0 41.0+/-10.0 23.7-58.3 Ra-226 4.5+/-0.5 5.0+/-0.8 3.6-6.4 Ra-228 4.4+/-0.6 5.2+/-0.8 3.6-6.4 Uranium 4.7+/-1.2 5.0+/-6.0 0.0-15.4 Sample B Gr. beta 51.3+/-3.0 54.0+/-5.0 45.3-62.7 Sr-89 3.7+/-1.2 11.0+/-5.0 2.3-19.7 Sr-90 10.7+/-1.2 10.0+/-1.5 7.4-12.6 Cs-134 15.3+/-2.3 15.0+/-5.0 6.3-23.7 Cs-137 16.7+/-1.2 15.0+/-5.0 6.3-23.7 A-5
Table A-1. (continued) Concentration in ~iLLb Lab Sample Date TIML Result EPA Resultd Code Type Collected Analysis +/-2oC ls, N=l Control Limits STM-554
- Milk Oct 1988 Sr-89 40.3+/-7.0 40.0+/-5.0 31.3-48.7 Sr-90 51.0+/-2.0 60.0+/-3.0 54.8-65.2 1-131 94.0+/-3.4 91.0+/-9.0 75.4-106.6 Cs-137 45.0+/-4.0 50.0+/-5.0 41.3-58.7 K
1500+/-45 1600+/-80 1461-1739 STU-555 Urine Nov 1988 H-3 3030+/-209 3025+/-359 2403-3647 STW-556 _Water Nov 1988 Gr. alpha 9.0+/-3.5 9.0+/-5.0 0.3-17.7 Gr. beta 9.7+/-1.2 9.0+/-5.0 0.3-17.7 STW-557 Water Dec 1988 1-131 108.7+/-3.0 115.0+/-12.0 94.2-135.8
- sTW-559 Water Jan 1989 Sr-89 40.0+/-8.7 40.0+/-5.0 31.3-48.7
- Sr-90 24.3+/-3.1 25.0+/-1.5 22.4-27.6 STW-560 Water Jan 1989 Pu-239 5.8+/-1.1 4.2+/-0.4 3.5-4.9 STW-561 Water Jan 1989 _ Gr. alpha 7.3+/-1.2 8.0+/-5.0 0.0-16.7 Gr. beta 5.3+/-1.2 4.0+/-5.0 0.0-127
- sTW-562 Water Feb 1989 Cr-51 245+/-46 235+/-24 193.4-276.6 c~
10.0+/-2.0 10.0+/-5.0 1.3-18.7 Zn-65 170+/-10 159+/-16 139.2-186.7 Ru-106 181+/-7.6 178+/-18 146.8-209.2 Cs-134 9.7+/-3.0 10.0+/-5.0 1.3-18.7 Cs-137 11.7+/-1.2 10.0+/-5.0 1.3-.18.7 STW-563 Water Feb 1989 1-131 109.0+/-4.0 06.0+/-11.0 86.9-125.1 STW-564 Water Feb 1989 H-3 2820+/-20 2754+/-356 2137-3371 STW-565 Water Mar1989 Ra-226 4.2+/-0.3 4.9+/-0.7 3.7-6.1 Ra-228 1.9+/-1.0 1.7+/-0.3 1.2-2.2 STW-566 Water Mar1989 u 5.0+/-0.0 5.0+/-6.0 0.0-15.4 STAF-567 Air Filter Mar1989 Gr. alpha 21.7+/-1.2 21.0+/-5.0 12.3-29,7 Gr. beta 68.3+/-4.2 62..0+/-5.0 53.3-70.7 Sr-90 20.0+/-2.0 20.0+/-1.5 17.~22.6 Cs-137 21.3+/-_1.2 20.0+/-5.0 11.3-28.7 A-: 6
Table A-1. (continued) Concentration in m;;;iLLb lab Sample Date TIML Result EPA Resultd Code Type Collected Analysis +/-2oC ls, N=l Control Limits STW-568
- water Apr1989 569 (Blind)
Sample A Gr. alpha 227+/-2.3 29.0+/-7.0 16.9-41.2 Ra-226 3.6+/-0.6 3.5+/-0.5 2.6-4.4 Ra-228 26+/-1.0 3.6+/-05 2.7-4.5 u 3.0+/-0.0 3.0+/-6.0 0.0-13.4 Sample B Gr. beta 523+/-6.1 57.0+/-5.0 43.3-65.7 Sr-89 9.3+/-5.4 8.0+/-5.0 0.0-16.7 Sr-90 7.0+/-0.0 8.0+/-1.5 5.4-10.6 Cs-134 21.0+/-5.2 20.0+/-5.0 11.3-28.7 Cs-137 23.0+/-2.0 20.0+/-5.0 11.3-28.7 STM-570 Milk Apr1989 Sr-89 26.0+/-10.0 39.0+/-5.0 30.3-47.7 Sr-90 45.7+/-4.2 55.0+/-3.0 49.8-60.2 Cs-137 54.0+/-6.9 50.0+/-5.0 41.3-58.7 K-40 1521+/-208 1600+/-80 1461-1739 STW-571g Water May1989 Sr-89 <0.7 6.0+/-5.0 0.0-14.7 Sr-90 5.0+/-1.0 6.0+/-1.5 3.4-8.6 STW-572 Water May1989 Gr. alpha 24.0+/-2.0 30.0+/-8.0 16.1-43.9 Gr. beta 49.3+/-15.6 50.0+/-5.0 41.3-58.7 STW-573 Water Jun 1989 Ba-133 50.7+/-1.2 49.0+/-5.0 40.3-57.7 Co-60 31.3+/-2.3 31.0+/-5.0 22.3-39.7 Zn-65 167+/-10 165+/-17. 135.6-194.4 Ru-106 123+/-9.2 128+/-13 105.5-150.5 Cs-134 40.3+/-1.2 39+/-5 30.3-47.7 Cs-137 223+/-1.2 20+/-5 11.3-28.7 STW-574 Water Jun 1989 H-3 4513+/-136 4503+/-450 3724-5282 STW-575 Water Jul 1989 Ra-226 16.8+/-3.1 17.7+/-2.7 13.0-22.4 Ra-228 13.8+/-3.7 18.3+/-27 13.6-23.0 STW-576 Water Jul 1989 u 40.3+/-1.2 41.0+/-6.0 30.6+/-51.4 STW-577 .Water Aug1989 1-131 84.7+/-5.8 83.0+/-8.0 69.1-96.9 STAF-579 Air Filter Aug1989 Gr. alpha 6.0+/-0.0 6.0+/-5.0 0.0-14.7 Cs-137 10.3+/-2.3 10.0+/-5.0 1.3-18.7 A-7
Table A-1. (continued) Concentration in ~iLLb
- Ulb Sample Date TIML Result EPA Resultd Code Type Collected Analysis
+/-2oC ls, N=l Control Limits STW-580 Water Sep 1989 Sr-89 14.7+/-1.2 14.0+/-5.0 5.3-227 Sr-90 9.7+/-1.2 10.0+/-1.5 7.4-126 STW-581 Water Sep 1989 Gr. alpha 5.0+/-0.0 4.0+/-5.0 0.0-127 Gr. beta 8.7+/-23 6.0+/-5.0 0.0-14.7 STW-583 Water Oct 1989 Ba-133 60.3+/-10.0 59.0+/-6.0 48.6-69.4 c~ 29.0+/-4.0 30.0+/-5.0 21.1-38.7 Zn-65 132.3+/-6.0 129.0+/-13.0 106.5-151.5 Ru-106 155.3+/-6.1 161.0+/-16.0 133.3-188.7 Cs-134 30.7+/-6.1 29.0+/-5.0 20.3-37.7 Cs-137 66.3+/-4.6 59.0+/-5.0 50.3-67.7 STW-584 Water Oct 1989 H-3 3407+/-150 3496+/-364 2866-126 STW-585 Water Oct 1989 586 (Blind) Sample A Gr. alpha 41.7+/-9.4 49.0+/-12.0 28.2-69.8
- Ra-226 7.9+/-0.4 8.4+/-1.3 6.2:..10.6 Ra-228 4.4+/-0.8 4.1+/-0.6 3.1-5.1 u
120+/-0.0 120+/-6.0 1.6-224 Sample B Gr. beta 31.7+/-23 320+/-5.0 23.3-40.7 Sr-89 13.3+/-4.2 15.0+/-5.0 6.3-23.7 Sr-90 7.0+/-20 7.0+/-3.0 4.4-9.6 Cs-134 5.0+/-0.0 5.0+/-5.0 0.0-13.7 Cs-137 7.0+/-0.0 5.0+/-5.0 0.0-13.7 STW-587 Water Nov 1989 Ra-226 7.9+/-0.4 8.7+/-1.3 6.4-11.0 Ra-228 8.9+/-1.2 9.3+/-1.2 6.9-11.7 STW-588. Water Nov 1989 u 15.0+/-0.0 15.0+/-6.0 4.6-25.4 STW-589 Water Jan 1990 Sr-89 227+/-5.0 25.0+/-5.0 16.3-33.7 Sr-90 17.3+/-1.2 20.0+/-1.5 17.4-22.6 STW-591 Water Jan 1990 Gr. alpha 10.3+/-3.0 120+/-5.0 3.3-20.7 Gr. beta 123+/-1.2 120+/-5.0 3.3-20.7 A-8
Table A-1. (continued) Concentration in ~iLLb um Sample Date TIML Result EPA Resultd Code Type Collected Analysis +/-2oC ls, N=l Control Limits STW-592 Water* Jan 1990 Co-60 14.7+/-2.3 15+/-5.0 6.3-23.7 Zn-65 135.0+/-6.9 139.0+/-14.0 114.8-163.2 Ru-106 133.3+/-13.4 139.0+/-14.0 114.8-163.2 Cs-134 17.3+/-12 18.0+/-5.0 9.3-26.7 Cs-137 19.3+/-12 18.0+/-5.0 9.3-26.7 Ba-133 78.0+/-0.0 74.0+/-7.0 61.9-86.1 STW-593 Water Feb 1990 H-3 4827+/-83 4976+/-498 4113-5839 STW-594 Water Mar1990 Ra-226 5.0+/-0.2 4.9+/-0.7 4.1-5.7 Ra-228 13.5+/-0.7 12.7+/-1.9 9.4-16.0 STW-595 Water Mar 1990 u 4.0+/-0.0 4.0+/-6.0 0.0-14.4 STAF-596 Air Filter Mar 1990 Gr. alpha 7.3+/-1.2 5.0+/-5.0 0.0-13.7 Gr. beta 34.0+/-0.0 31.0+/-5.0 22.3-39.7 Sr-90 10.0+/-0.0 10.0+/-1.5 7.4-12.6 Cs-137 9.3+/-1.2 10.0+/-5.0 1.3:-18.7 STW-597 Water Apr 1990 598 (Blind) Sample A Gr. alpha 81.0+/-3.5 90.0+/-23.0 50.1-129.9 Ra-226 4.9+/-0.4 5.0+/-0.8 3.6-6.4 Ra-228 10.6+/-0.3 10.2+/-1.5 7.6-12.8 u 18.7+/-3.0 20.0+/-6.0 9.6-30.4 Sample B Gr. beta 51.0+/-10.1 52.0+/-5.0 43.3-60.7 Sr-89 9.3+/-1.2 10.0+/-5.0 1.3-18.7 Sr-90 10.3+/-3.1 10.0+/-1.5 8.3-11.7 Cs-134 16.0+/-0.0 15.0+/-5.0 6.3-23.7 Cs-137 19.0+/-2.0 15.0+/-5.0 6.3-23.7 STM-599 Milk Apr1990 Sr-89 21.7+/-3.1 23.0+/-5.0 14.3-31.7 Sr-90 21.0+/-7.0 23.0+/-5.0 14.3-31.7 1-131 98.7+/-1.2 99.0+/-10.0 81.7-116.3 Cs-137 26.0+/-6.0 24.0+/-5.0 15.3-32.7 K 1300.0+/-69.2 1550.0+/-78.0 1414.7-1685.3 STW-600 Water May1990 Sr-89 6.0+/-2.0 7.0+/-5.0. 0.0-15.7 Sr-90 6.7+/-1.2 7.0+/-5.0 0.0-15.7 STW-601 Water May1990 Gr. alpha 11.0+/-2.0 22.0+/-6.0 11.6-32.4 Gr. beta 123+/-1.2 15.0+/-5.0 6.3-23.7 A-9
Table A-1. (continued) Concentration in ~iLLb
- um Sample Date TIML Result EPA Resultd Code Type Collected Analysis
+/-2oC ls, N=l Control Limits STW-602 Water Jun 1990 Co-60 25.3+/-2.3 24.0+/-5.0 15.3-32.7 Zn-65 155.0+/-10.6 148.0+/-15.0 130.6-165.4 Ru-106 2027+/-17.2 210.0+/-21.0 173.6-246.4 Cs-134 23.7+/-1.2 24.0+/-5.0 18.2-29.8 Cs-137 27.7+/-3.1 25.0+/-5.0 16.3-33.7 Ba-133 100.7+/-8.1 99.0+/-10.0 81.7-116.3 STW-603 Water Jun 1990 H-3 2927+/-306 2933+/-358 2312-3554 STW-604 Water Jul 1990 Ra-226 11.8+/-0.9 121+/-1.8 9.0-15.2 Ra-228 4.1+/-1.4 5.1+/-1.3 2.8-7.4 STW-605 Water Jul 1990 u 20.3+/-1.7 20.8+/-3.0 15.6-26.0 STW-606 Water Aug 1990 1-131 43.0+/-1.2 39.0+/-6.0. 28.6-49.4 STW-607 Water Aug1990 Pu-239 10.0+/-1.7 9.1+/-{).9 7.5-10.7 STAF-608 Air Filter Aug1990 Gr. alpha 14.0+/-0.0 10.0+/-5.0 1.3-18.7 Gr. beta 65.3+/-1.2 620+/-5.0 53.3-70.7 Sr-90 19.0+/-6.9 20.0+/-5.0 11.3-28.7 Cs-137 19.0+/-20 20.0+/-5.0 11.3-28.7 STW-609 Water Sep 1990 Sr-89 9.0+/-20 10.0+/-5.0' 1.3-18.7. Sr-90 9.0+/-20 9.0+/-5.0 0.3-17.7 STW-610 Water Sep 1990 Gr. alpha 83+/-1.2 10.0+/-5.0 1.3-18.7 Gr. beta 10.3+/-1.2 10.0+/-5.0 1.3-18.7 STM-611 Mille Sep 1990 Sr-89 11.7+/-3.1 16.0+/-5.0 7.3-24.7 Sr-90 15.0+/-0.0 20.0+/-5.0 11.3-28.7 1-131 63.0+/-6.0 58.0+/-6.0 47.6-68.4 Cs-137 20.0+/-20 20.0+/-5.0 11.3-28.7 K 1673.3+/-70.2 1700.0+/-85.0 15525-1847.5 STW:.612 Water Oct 1990 Co-60 20.3+/-3.1 20.0+/-5.0 11.3-28.7 Zn-65 115.3+/-12.2 115.0+/-120 94.2-135.8 Ru-106 152.0+/-8.0 151.0+/-15.0 125.0-177.0 Cs-134 11.0+/-0.0 120+/-5.0 3.3-20.7 Cs-137 14.0+/-20 120+/-5.0 3.3-20.7 Ba-133 116.7+/-9.9 110.0+/-11.0 90.9-129 STW-613 Water Oct 1990 H-3 7167+/-330. 7203+/-720 5954-8452
- A-10
~ Table A-1. (continued) Concentration in ~iLLb Lab Sample Date TIML Result EPA Resultd Code Type Collected Analysis +/-2oC ls, N=l Control Limits STW-614
- water Oct 1990 615 Sample A Gr. alpha 68.7+/-7.2 62.0+/-16.0 34.2-89.8 Ra-226 129+/-0.3 13.6+/-2.0 10.1-17.1 Ra-228 4.2+/-0.6 5.0+/-1.3 2.7-7.3 u
10.4+/-0.6 10.2+/-3.0 5.0-15.4 Sample B Gr. beta 55.0+/-8.7 53.0+/-5.0 44.3-61.7 Sr-89 15.7+/-2.9 20.0+/-5.0 11.3-28.7 Sr-90 120+/-2.0 15.0+/-5.0 6.3-23.7 Cs-134 9.0+/-1.7 7.0+/-5.0 0.0-15.7 Cs-137 7.7+/-1.2 5.0+/-5.0 0.0-13.7 STW-616 Water Nov 1990 Ra-226 6.8+/-1.0 7.4+/-1.1 5.5-9.3 Ra-228. 5.3+/-1.7 7.7+/-1.9 4.4-11.0 STW-617g Water Nov 1990 .u 35.0+/-0.4 35.5+/-3.6 29.3-41.7 STW-618 Water Jan 1991 Sr-89 4.3+/-1.2 5.0+/-5.0 0.0-13.7 Sr-90 4.7+/-1.2 5.0+/-5.0 0.0-13.7 STW-6l9 Water Jan 1991 Pu-239 3.6+/-0.2 3.3+/-0.3 2.8-3.8 STW-620 Water Jan 1991 Gr. alpha 6.7+/-3.0 5.0+/-5.0 0.0-13.7 Gr. beta 6.3+/-1.2 5.0+/-5.0 0.0-13.7 STW-621 Water Feb 1991 Co-60 41.3+/-8.4 40.0+/-5.0 31.3-48.7 Zn-65 166.7+/-19.7 149.0+/-15.0 123.0-175.0 Ru-106 209.7+/-18.6 186.0+/-19.0 153.0-219.0 Cs-134 9.0+/-2.0 8.0+/-5.0 0.0-16.7 Cs-137 9.7+/-1.2 8.0+/-5.0 0.0-16.7 Ba-133 85.7+/-9.2 75.0+/-8.0 61.. 1-88.9 STW-622 Water Feb 1991 1-131 81.3+/-6.1 75.0+/-8.0 61.1-88.9 STW-623 Water Feb 1991 H-3 4310.o+/-144.2 4418.0+/-4420 3651.2-5184.8 STW-624 Water Mar1991 Ra-226 31.4+/-3.2 31.8+/-4.8 23.5-40.1 Ra-228 Noh 21.1+/-5.3 11.9-30.3 STW-625 Water Mar1991 u 6.7+/-0.4 7.6+/-3.0 2.4-128. A-11
- i Table A-1. (continued)
Concentration in ~iLLh
- Lab Sample Date TIML Result EPA Resultd Code Type Collected Analysis
+/-2oC ls, N=l Control Limits STAF-626 Air Filter Mar 1991 Gr. alpha 38.7+/-1.2 25.0+/-6.0 14.6-35.4 Gr. beta 130.0+/-4.0 124.0+/-6.0. 113.6-134.4 Sr-90 35.7+/-1.2 40~0+/-5.0 31.3-48.7 Cs-137 33.7+/-4.2 40.0+/-5.0 31.3-48.7 STW-627 Water* Apr 1991 628 Sample A Gr. alpha 51.0+/-6.0 54.0+/-14.0 29.7-78.3 Ra-226 7.0+/-0.8 8.0+/-1.2 5.9-10.1 Ra-228 9.7+/-1.9 15.2+/-3.8 8.6-21.8 u 27.7+/-2.4 29.8+/-3.0. 24.6-35.0 Sample B Gr. beta 93.3+/-6.4 115.0+/-17.0 . 85.5-144.5 Sr-89 21.0+/-3.5 28.0+/-5.0 19.3-36.7 Sr-90 23.0+/-0.0 26.0+/-5.0 17.3-34.7 Cs-134. 27.3+/-1.2 24.0+/-5.0 15.3-327 Cs-137 29.0+/-2.0 25.0+/-5.0 16.3-33.7 STM-629 Milk Apr 1991 Sr-89 24.0+/-8.7 320+/-5.0 23.3-40.7 Sr-90 28.0+/-2.0 32.0+/-5.0 23.3-40.7 I-131 65.3+/-14.7 60.0+/-6.0 49.6-70.4 Cs-137 54.7+/-11.0 49.0+/-5.0 40.3-57.7 K 1591.7+/-180.1 1650.0+/-83.0 1506.0-1794.0 STW-630 Water May1991 Sr-89 40.7+/-2.3 39.0+/-5.0 30.3-47.7 Sr-90 23.7+/-1.2 24.0+/-5.0 15.3-327 STW-631 Water May1991 Gr. alpha 27.7+/-5.8 24.0+/-6.0 13.6-34.4 Gr. beta 46.0+/-0.0 46.0+/-5.0 37.3-54.7 STW-632 Water Jun 1991 Co-60 11.3+/-1.2 10.0+/-5.0 1.3-18.7 Zn-65 119;3+/-163 108.0+/-11.0 88.9-127.1 Ru-106 162.3+/-19.0 149.0+/-15.0 123.0-175.0 Cs-134 15.3+/-1.2 15.0+/-5.0 6.3-23.7 Cs-137 16.3+/-1.2 14.0+/-5.0 5.3-22.7 Ba-133 74.0+/-6.9 62.0+/-6.0 51.6-724 STW-633 Water Jun 1991 H-3 13470.0+/-385.8 12480.0+/-1248.0 10314.8-14645.2 STW-634 Water Jul 1991 Ra-226 14.9+/-0.4 15.9+/-2.4 11.7-20.1 Ra-228 17.6+/-1.8 16.7+/-4.2 9.4-24.0 A-12
~ Table A-1. (continued) Concentration in ~iLLb lab Sample Date TIML Result EPA Resultd Ccxie Type Collected Analysis +/-2oC ls, N=l Control Limits STW-635
- Water Jul 1991 u
128+/-0.1 14.2+/-3.0 9.0-19.4 STW-636 Water Aug 1991 1-131 19.3+/-1.2 20.0+/-6.0 9.6-30.4 STW-637 Water Aug1991 Pu-239 21.4+/-0.5 19.4+/-1.9 16.1-22.7 STAF-638 Air Filter Aug 1991 Gr. alpha 33.0+/-2.0 25.0+/-6.0 14.6-35.4 Gr. beta 88.7+/-1.2 92.0+/-10.0 80.4-103.6 Sr-90 27.0+/-4.0 30.0+/-5.0 21.3-38.7 Cs-137 26.3+/-1.2 30.0+/-5.0 21.3-38.7 STW-639 Water Sep 1991 Sr-89 47.0+/-10.4 49.0+/-5.0 40.3-57.7 Sr-90 24.0+/-2.0 25.0+/-5.0 16.3-33.7 STW-640 Water Sep 1991 Gr. alpha 120+/-4.0 10.0+/-5.0 1.3-18.7 Gr. beta 20.3+/-1.2 20.0+/-5.0 11.3-28.7 STM-641 Milk Sep 1991 Sr-89 20.3+/-5.0 25.0+/-5.0 16.3-33.7 Sr-90 19.7+/-3.1 25.0+/-5.0 16.3-33.7 1-131 130.7+/-16.8 108.0+/-11.0 88.9-127.1 Cs-137 33.7+/-3.2 30.0+/-5.0 21.3-38.7 K 1743.3+/-340.8 1740.0+/-87.0 1589.1-1890.9 STW-642 Water Oct 1991 Co-60 29.7+/-1.2 29.0+/-5.0 20.3-37.7 Zn-65 75.7+/-8.3 73.0+/-7.0 60.9-85.1 Ru-106 196.3+/-15.1 199.0+/-20.0 164.3-233.7 Cs-134 9.7+/-1.2 10.0+/-5.0 1.3-18.7 Cs-137 11.0+/-2.0 10.0+/-5.0 1.3-18.7 Ba-133 94.7+/-3.1 98.0+/-10.0 80.7-115.3 STW-643 Water Oct 1991 H-3 2640.0+/-156.2 2454.0+/-3520 1843.3-3064.7 STW-644 Water Oct 1991 645 Sample A Gr. alpha 73.0+/-13.1 82.0+/-21.0 45.6-118.4 Ra-226 20.9+/-2.0 220+/-3.3 16.3-27.7 Ra-228 19.6+/-2.3 222+/-5.6 12.5-31.9 u 13.5+/-0.6 13.5+/-3.0 8.3-18.7 Sample B Gr. beta 55.3+/-3.1 65.0+/-10.0 47.7-82.3 Sr-89 9.7+/-3.1 10.0+/-5.0 1.3-18.7 Sr-90 8.7+/-1.2 10.0+/-5.0 1.3-18.7 Co-60 20.3+/-1.2 20.o+/-s.o 11.3-28.7 Cs-134 9.0+/-5.3 10.0+/-5.0 1.3-18.7 Cs-137 14.7+/-5.0 11.0+/-5.0 2.3-19.7 A-13
Table A-1. (continued) Concentration in ~iLLb
- I.ab Sample Date TIML Result EPA Resultd Code Type Collected Analysis
+/-2oC ls, N=l Control Limits STW-646 Water Nov 1991 Ra-226 5.6+/-1.2 6.5+/-1.0 4.8-8.2 Ra-228 9.6+/-0.5 8.1+/-2.0 4.6-11.6 STW-647 Water Nov 1991 u 24.7+/-2.3 24.9+/-3.0 19.7-30.1 STW-648 Water Jan 1992 Sr-89 427+/-6.4 51.0+/-5.0 42.3-59.7 Sr-90 18.3+/-3.1 20.0+/-5.0 11.3-28.7 STW-649 Water Jan 1992 Pu-239 16.1+/-0.8 16.8+/-1.7 13.9-19.7 STW-650 Water Jan 1992 Gr. alpha 23.7+/-9.2 30.0+/-8.0 16.1-43.9 Gr. beta 27.7+/-4.2 30.0+/-5.0 21.3-38.7 STW-651 Water Feb 1992 I-131 60.3+/-4.2 59.0+/-6.0 48.6-69.4 STW-652 Water Feb 1992 Co-60 40.3+/-5.0 40.0+/-5.0 31.3-48.7 Zn-65 148.0+/-15.0 150.7+/-6.1 122.0-174.0 Ru-106 188.7+/-28.8 203.0+/-20.0 168.3-237.7 Cs-134 31.7+/-4.2 31.0+/-5.0 22.3-39.7 Cs-137 51.0+/-3.4 49.0+/-5.0 40.3-57.7 Ba-133 79.0+/-3.4 76.0+/-8.0 62.1-89.9 STW-653 Water Feb 1992 H-3 7714.0+/-119.6 7904.0+/-790.0 6533.4-9274.6 STW-654 Water Mar 1992 Ra-226 9.0+/-0.4 10.1+/-1.5 7.5-127 Ra-228 18.8+/-0.6 15.5+/-3.9 8.7-223 STW-655 Water Mar1992 Ru-222i STW-656 Water Mar 1992 u 25.1+/-1.9 25.3+/-3.0 20.1-30.5 STW-657 Water Mar1992 Ru-222i STAF-658 Air Filter Mar1992 Gr. alpha 7.0+/-0.0 7.0+/-5.0 0.0-15.7 Gr. beta 39.3+/-1.6 41.0+/-5.0 32.3-49.7 Sr-90 13.7+/-1.6 15.0+/-5.0 6.3-23.7 Cs-137 10.0+/-0.0 10.0+/-5.0 1.3-18.7 STW-659 Water Apr 1992 660 Sample A Gr. alpha 35.7+/-6.1 40.0+/-10.0 22.7-57.3 Ra-226 127+/-1.2 14.9+/-2.2 11.1-18.7 Ra-228 14.5+/-2.1 14.0+/-3.5 7.9-20.1 u 3.9+/-0.2 4.0+/-3.0 0.0-9.2
- A-14
Table A-1. (continued) Concentration in ~iLLb lab Sample Date TIML Result EPA Resultd Code Type Collected Analysis +/-2oC ls, N=l Control Limits STW-659 Water Apr 1992 660 Sample B Gr. beta 113.0+/-7.2 140.0+/-21.0 103.6-176.4 Sr-89 123+/-4.2 15.0+/-5.0 6.3-23.7 Sr-90 15.0+/-1.2 17.0+/-5.0 8.3-25.7 Co-60 61.0+/-4.0 56.0+/-5.0 47.3-64.7 Cs-134 24.3+/-1.2 24.0+/-5.0 15.3-327 Cs-137 24.0+/-2.0 220+/-5.0 13.3-30.7 STM-661 Milk Apr1992 Sr-89 25.3+/-7.6 38.0+/-5.0 29.3-46.7 Sr-90 24.3+/-3.1 29.0+/-5.0 20.3-37.7 I-131 78.7+/-9.5 78.0+/-8.0 64.1-91.9 Cs-137 39.3+/-2.3 39.0+/-5.0 30.3-47.7 K 1610.0+/-72.1 1710.0+/-86.0 1560.8-1859.2 STW-662 Water May1992 Sr-89 24.0+/-4.0 29.0+/-5.0 20.3-37.7 Sr-90 6.7+/-1.2 8.0+/-5.0 0.0-16.7 STM-663 Water May1992 Gr. alpha 123+/-21 15.0+/-5.0 6.3-23.7 Gr. beta 46.0+/-5.0 44.0+/-5.0 35.3-527 STW-664 Water Jun 1992 Co-60 20.3+/-1.2 20.0+/-5.0 11.3-28.7 Zn-65 103.3+/-10.6 99.0+/-10.0 81.7-1163 Ru-106 142.7+/-23.7 141.0+/-14.0 116.7-1653 Cs-134 14.3+/-2.3 15.0+/-5.0 6.3-23.7 Cs-137 15.0+/-2.0 15.0+/-5.0 6.3-23.7 Ba-133 92.7+/-11.0 98.0+/-10.0 80.7-115.3 STW-665 Water Jun 1992 H-3 2153.3+/-144.6 2125.0+/-347.0 1523.0-2727.0 STW-666 Water July 1992 Ra-226 223+/-2.2 24.9+/-3.7 18.S-313 Ra-228 16.7+/-3.1 16.7+/-4.2 9.4-24.0 STW-667 Water July 1992 u 3.6+/-0.3 4.0+/-3.0 0.0-9.2 STW-668 Water August 1992 I-131 47.0+/-3.5 45.0+/-6.0 34.6-55.4 STW-669 Water August 1992 Pu-239 8.5+/-0.9 9.0+/-0.9 7.4-10.6 STAF-670 Air Filter August 1992 Gr. alpha 25.7+/-1.2 30.0+/-8.0 16.1-43.9 Gr. beta 69.0+/-2.0 69.0+/-10.0 51.7-863 Sr-90 26.0+/-4.0 25.0+/-5.0 16.3-33.7 Cs-137 16.0+/-0.0 18.0+/-5.0 9.3-26.7 A-15
Table A-1. (continued) Concentration in ~iLLb I.ab Sample Date TIML Result EPA Resultd Code Type Collected Analysis +/-2oC ls, N=l Control Limits STW-671 . Water Sept. 1992 Sr-89 16.0+/-4.0 20.0+/-5.0 11.3-28.7 Sr-90 14.3+/-3.1 15.0+/-5.0 6.3-23.7 STW-672 Water Sept. 1992 Gr. alpha 43.0+/-13.1 45.0+/-11.0 25.9-64.1 Gr. beta 41.3+/-18.6 50.0+/-5.0 41.3-58.7 STM-673 Milk Sept.1992 Sr-89 11.0+/-3.5 15.0+/-5.0 6.3-23.7 Sr-90 127+/-1.2 15.0+/-5.0 6.3-23.7 1-131 109.7+/-19.4 100.0+/-10.0 827-117.3 Cs-137 14.0+/-3.5 15.0+/-5.0 6.3-23.7 K 1540.0+/-103.9 1750.0+/-88.0 1597.3-1902.7 STW-674 Water Oct. 1992 Co-60 11.3+/-2.3 10.0+/-5.0 1.3-18.7 Zn-65 169.7+/-25.0 148.0+/-15.0 122.0-174.0 Ru-106 170.1+/-2.3 175.0+/-18.0 143.8-206.2 Cs-134 9.7+/-2.3 8.0+/-5.0 0.0-16.7 Cs-137 9.7+/-1.2 8.0+/-5.0. 0.0-16.7 Ba-133 80.3+/-9.0 74.0+/-7.0 61.9-86.1 STW-675 Water Oct. 1992 H-3 5896.7+/-136.2 5962.0+/-596.0 4928.0-6996.0 STW-676 Water Oct. 1992 -677 Sample A Gr. alpha 24.7+/-5.0 29.0+/-7.0 16.9-41.1 Ra-226 7.1+/-0.4 7.4+/-1.1 5.5-9.3 Ra-228 11.5+/-1.0 10.0+/-2.5 5.7-14.3 u 9.7+/-0.5 10.2+/-3.0 5.0-15.4 Sample B Gr. beta 427+/-8.1 53.0+/-10.0 35.7-70.3 . Sr-89 6.7+/-1.2 8.0+/-5.0 0.0-16.7 Sr-90 10.0+/-2.0 10.0+/-5.0 1.3-18.7 Co-60 15.0+/-2.0 15.0+/-5.0 6.3-23.7 Cs-134 5.7+/-1.2. 5.0+/-5.0 0.0-13.7 Cs-137 8.0+/-2.0 8.0+/-5.0 0.0-16.7 A-16
Table A-1. (continued) Concentration in ~iLLb um Sample Date TIML Result EPA Resultd Code Type Collected Analysis +/-2oC ls, N=l Control LimitS STW-678
- Water Nov. 1992 Ra-226 7.5+/-0.8 7.5+/-1.1 5.6-9.4 Ra-228 5.8+/-0.7 5.. 0+/-1.3
. 2..7-7.3 STW-679 Water Nov. 1992 u 15.5+/-1.1 15.2+/-3.0 10.0-20.4 a Results obtained by Teledyne lsptopes Midwest Laboratory as a participant in the environmental sample crosscheck program operated by the Intercomparison and Calibration Section, Quality Assurance Branch, Environmental Monitoring and Support Laboratory, U.S. Environmental Protection Agency (EPA), Las Vegas, Nevada. b All results are in pCi/l, except for elemental potassium (K) data in milk, which are in mg/I; air filter samples, which are in pCi/filter; and food, which is in mg/kg. c Unless otherwise indicated, the TIML results are given as the mean+/- 2 standard deviations for three determinations. d USEPA results are presented as the known values and expected laboratory precision (ls, 1 determination) and control limits as defined by EPA. e NA = Not analyzed.. f ND= No data; not analyzed due to relocation of lab. g Sample was analyzed but the results not submitted to EPA because deadline was missed (all data on file). h ND = No data; sample lost during analyses. i ND = No data; special EPA testing. A-17
A-18
r / t Table A-2. Crosscheck program results, thermoluminescent dosimeters (TLDs). r' mR Teledyne Average +/-2 I.ab Result Known (All Participan~ Code TLDType Measurement +/-2aCl Value 115-78 .CaF2:Mn Field 71.5+/-2.6 75.8+/-6.0 75.1+/-29.8 Bulbs Lab (CcH,O) 84.8+/-6.4 79;9+/-4.0 77.9+/-27.6 Lab (Cs-137) 78.8+/-1.6 75.0+/-3.8 73.0+/-22.2 115-7C CaS04:Dy Field 76.8+/-2.7 75.8+/-6.0 75.1+/-29.8 Cards Lab (Co-60) 82.5+/-3.7 79.9+/-4.0 77.9+/-27.6 Lab (Cs-137) 79.0+/-3.2 75.0+/-3.8 73.0+/-22.2 8th International Intercomparisoni 115-8A LiF-100 Field Site 1 29.5+/-1.4 29.7+/-1.5 28.9+/-12.4 Chips Field Site 2 11.3+/-0.8 10.4+/-0.5 10.1+/-9.06 Lab (Cs-137) -13.7+/-0.9 17.2+/-0.9 16.2+/-6.8 115-88 CaF2:Mn Field Site 1 32.3+/-1.2 29,7+/-1.5 28.9+/-12.4 Bulbs Field Site 2 9.0+/-1.0 10.4+/-0.5 10.1+/-9.0 Lab (Cs-137) 15.8+/-0.9 17.2+/-0.9 16.2+/-6.8 115-BC CaS04:Dy Field Site 1 32.2+/-0.7 29.7+/-1.5 28.9+/-12.4 Cards Field Site 2 10.6+/-0.6 10.4+/-0.5 10.1+/-9.0 Lab (Cs-137) 18.1+/-0.8 17.2+/-0.9 16.2+/-6.8 Teledyne Testing 89-1 LiF-100 lab 21.0+/-0.4 22.4 ChipS 89-2 Teledyne lab 20.9+/-1.0 203 CaS04:Dy Cards A-19
Table A-2. (continued) mR Teledyne Average +/-2ad Lab Result Known (All Participants) Code TLDType Measurement +/-2aa Value Teledyne T~ting 90-1k Teledyne 20.6+/-1.4 .19.6 CaS04:Dy Cards 90-21 Teledyne 100.8+/-4.3 100.0 CaS04:Dy Cards 91-lm
- Teledyne 33.4+/-2.0 320 CaS04:Dy 55.2+/-4.7 58.8 Cards 87.8+/-6.2 85.5 92-ln LiF-100 11.1+/-0.2 10.7 Chips 25.6+/-0.5 25.4 46.4+/-0.5 46.3 92-20 Teledyne Lab (Reader #1) 20.1+/-0.1 20.1 CaS04:Dy 40.6+/-0.1 40.0 Cards 60.0+/-1.3 60.3 Lab (Reader #2) 20.3+/-0.3 20.1 39.2+/-0.3 40.0 60.7+/-0.4 60.3 a Lab result given is the mean +/-2 standard deviations of three determinations.
b Second International Intercomparison of Environmental Dosimeters conducted in April of 1976 by the Health and Safety Laboratory (HASL), New York, New York, and the School of Public Health of the University of Texas, Houston, Texas. c Value determined by sponsor of the intercomparison using continuously operated pressurized ion chamber. d Mean +/-2 standard deviations of results obtained by all laboratories participating in the program. e Third International Intercomparison of Environmental Dosimeters conducted in summer of 1977 by Oak Ridge National Laboratory and the School of Public Health of the University of Texas, Houston, Texas. f Fourth International Intercomparison of Environmental Dosimeters conducted in summer of 1979 by the School of Public Health of the University of Texas Houston, Texas. g Fifth International Intercomparison of Environmental Dosimeters conducted in fall of 1980 at Idaho Falls, Idaho and sponsored by the School of Public Health of the University of Texas, Houston, Texas and Environmental Measurements Laboratory, New York, New York, U.S. Department of Energy. A-20
Table A-2. (continued) mR 14b Code Teledyne Result Known Value Average +/-2ad (All Participants) TLDType Measurement +/-2oa Footnotes (continued) h Seventh International Intercomparison of Environmental Dosimeters' conducted in the spring and summer of1984 at Las Vegas, Nevada, and sponsored by the U.S. Department of Energy, The U.S. Nuclear Regulatory Commission, and the U.S. Environmental Protection Agency. i Eighth International Intercomparison of Environmental Dosimeters conducted in the fall and winter of 1985-1986.atNew York, New York, and sponsored by the U.S. Department of Energy. Chips were submitted in September 1989 and cards were submitted in November 1989 to Teledyne Isotopes, Inc., Westwood, NJ for irradiation. k Cards were irradiated by Teledyne Isotopes, Inc., Westwood, NJ on June 19, 1990. 1 Cards were irradiated by Dosimetry Associates, Inc., Northville, MI on October 30, 1990. m Irradiated cards were provided by Teledyne Isotopes, INC., Westwood, NJ. Irradiated on October 8, 1991. n Chips were irradiated by Teledyne Isotopes, Inc., Westwood, NJ on February 26, 1992. o Cards were irradiated by Teledyne Isotopes, Inc., Westwood, NJ on April 1, 1992. A-21
1 Table A-3. In-house spiked samples. Concentration in ~iLL um Sample Date TIML Expected Code Type Collected Analysis Result Known Precision 2s,n=3a Activity ls, n=3a QC-MI-16 Milk Feb 1988 Sr-89 31.8+/-4.7 31.7+/-6.0 8.7 Sr-90 25.5+/-27 27.8+/-3.5 5.2 1-131 26.4+/-0.5 23.2+/-5.0 10.4 Cs-134 23.8+/-23 24.2+/-6.0 8.7 Cs-137 26.5+/-0.8 25.1+/-6.0 8.7 QC-MI-17 Milk Feb 1988 1-131 10.6+/-1.2 14.3+/-1.6 10.4 QC-W-35 Water Feb 1988 1-131 9.7+/-1.1 11.6+/-1.1 10.4 QC-W-36 Water Mar 1988 1-131 10.5+/-1.3 11.6+/-1.0 10.4 QC-W-37 Water Mar 1988 Sr-89 17.1+/-2.0 19.8+/-8.0 8.7 Sr-90 18.7+/-0.9 173+/-5.0 5.2 QC-MI-18 Milk Mar 1988 1-131 33.2+/-2.3 26.7+/-5.0 10.4 Cs-134 31.3+/-21 30.2+/-5.0 8.7 Cs-137 29.9+/-1.4 26.2+/-5.0 8.7 QC-W-38 Water Apr1988 1-131 17.1+/-1.1 14.2+/-5.0 10.4 QC-W-39 Water Apr 1988 H-3 4439+/-31 . 4176+/-500 724 QC-W-40 Water Apr1988 Co-60 23.7+/-0.5 26.1+/-4.0 8.7 Cs-134 25.4+/-2.6 29.2+/-4.5 8.7 Cs-137 26.6+/-23 26.2+/-4.0 8.7 QC-W-41 Water Jun 1988 Gr. alpha 12.3+/-0.4 13.1+/-5.0 8.7 Gr. beta 22.6+/-1.0 20.1+/-5.0 8.7 QC-MI-19 Milk Jul 1988 Sr-89 15.1+/-1.6 16.4+/-5.0 8.7 Sr-90 18.0+/-0.6 183+/-5.0 5.2 1-131 88.4+/-4.9 86.6+/-8.0 10.4 Cs-137 22.7+/-0.8 20.8+/-6.0 8.7 QC-W-42 Water Sep 1988 Sr-89 48.5+/-3.3 50.8+/-8.0 8.7 Sr-90 10.9+/-1.0 11.4+/-3.5 5.2 QC-W-43 Water Oct 1988 Co-60 20.9+/-3.2 21.4+/-3.5 8.7 Cs-134 38.7+/-1.6 38.0+/-6.0 8.7 Cs-137 19.0+/-24 21.0+/-3.5 8.7 QC-W-44 Water Oct 1988 1-131 22..2+/-0.6 233+/-3.5 10.4 A-22
Table A-3. In-house spiked samples(continued) ~on~~ntration in ~iLL lab Sample Date TIML Expected Ccxie Type Collected Analysis Result Known Precision 2s, n=3a Activity ls, n=3a QC-W-45 Water Oct 1988 H-3 4109+/-43 4153+/-500 724 QC-MI-20 Milk Oct 1988 1-131 59.8+/-0.9 60.6+/-9.0 10.4 Cs-134 49.6+/-1.8 48.6+/-7.5 8.7 Cs-137 25.8+/-4.6 24.7+/-4.0 8.7 QC-W-46 Water Dec 1988 Gr. alpha 11.5+/-2.3 15.2+/-5.0 8.7 Gr. beta 26.5+/-2.0 25.7+/-5.0 8.7 Q:-MI-21 Milk Jan 1989 Sr-89 25.5+/-10.3 34.0+/-10.0 8.7
- Sr-90 28.3+/-3.2 27.1+/-3.0 52 1-131 540+/-13 550+/-20 10.4 Cs-134 24.5+/-2.6 22.6+/-5.5 8.7 Cs-137 24.0+/-0.6 20.5+/-5.0 8.7 QC-W-47 Water Mar 1989 Sr-89 1,5.2+/-3.8 16.1+/-5.0 8.7 Sr-90 16.4+/-1.7 16.9+/-3.0 52 QC-MI-22 Milk Apr1989 1-131 36.3+/-1.1 372+/-5.0 10.4 Cs-134 20.8+/-2.8 20.7+/-8.0 8.7 Cs-137 22.2+/-2.4 20.4+/-8.0 8.7 QC-W-48 Water Apr1989 Co-60 23.5+/-2.0 25.1+/-8.0 8.7 Cs-134 24.2+/-1.1 25.9+/-8.0 8.7 Cs-137 23.6+/-1.2 23.0+/-8.0 8.7 QC-W-49 Water Apr1989 1-131 37.2+/-3.7 37.2+/-5.0 10.4 QC-W-50 Water Apr1989 H-3 3011+/-59 3089+/-500 724 QC-W-51 Water Jun 1989 Gr. alpha 13.0+/-1.8 15.0+/-5.0 8.7 Gr. beta 26.0+/-1.2 25.5+/-8.0 8.7 QC-MI-23 Milk Jul 1989 Sr-89 19.4+/-6.5 22.0+/-10.0 8.7 Sr-90 27.6+/-3.5 28.6+/-3.0 52 I-131 46.8+/-3.2 43.4+/-5.0 10.4 Cs-134 27.4+/-1.8 28.3+/-6.0 8.7 Cs-137 24.1+/-1.8 20.8+/-6.0 8.7 QC-MI-24 Milk Aug 1989 Sr-89 25.4+/-2.7 27.2+/-10.0 8.7 Sr-90 46.0+/-1.1 47.8+/-9.6 52 QC-W-52 Water Sep 1989 I-131 9.6+/-03 9.7+/-1.9 10.4
- A-23
'*~I 1J Table A-3. In-house spiked samples (continued) Con~entration in ~iLL Lib Sample Date TIML Expected Ccxie Type Collected Analysis Result Known Precision 2s, n=3a Activity ls, n=3a QC-W-53 Water Sep 1989. 1-131 19.0+/-0.2 20.9+/-4.2 10.4 QC-W-54 Water Sep 1989 Sr-89 25.8+/-4.6 24.7+/-4.0 8.7 Sr-90 26.5+/-5.3 29.7+/-5.0 5.2 QC-MI-25 Milk Oct 1989 1-131 70.0+/-3.3 73.5+/-20.0 10.4 Cs-134 22.1+/-2.6 22.6+/-8.0 8.7 Cs-137 29.4+/-1.5 27.5+/-8.0 8.7 QC-W-55 Water Oct 1989 1-131 33.3+/-1.3 35.3+/-10.0 10.4 QC-W-56 Water Oct 1989 Co-60 15.2+/-0.9 17.4+/-5.0 8.7 Cs-134 22.1+/-4.4 18.9+/-8.0 87 Cs-137 27.2+/-1.2 229+/-8.0 8.7 QC-W-57 Water Oct 1989 H-3 3334+/-22 3379+/-500 724 QC-:W-58 Water Nov 1989 Sr-89 10.9+/-t.4d 11.1+/-1.od 8.7 Sr-90 10.4+/-UP 10.3+/-1.od 5.2 QC-W-59 Water Nov 1989 Sr-89 101.0+/-6.od 104.1+/-10.sd 18.0 Sr-90 98.0+/-3.od 95.0+/-10.od 16.4 QC-W-60 Water Dec 1989 Gr. alpha 10.8+/-1.1 10.6+/-4.0 87 Gr. beta 11.6+/-0.5 11.4+/-4.0 87 QC-MI-26 Mille Jan 1990 Cs-134 19.3+/-1.0 20.8+/-8.0 8.7 Cs-137 25.2+/-1.2 228+/-8.0 8.7 QC-MI-27 Mille Feb 1990 Sr-90 18.0+/-1.6 18.8+/-5.0 5.2 QC-MI-28 Mille Mar1990 1-131 63.8+/-2.2 62.6+/-6.0 10.8 QC-MI-61 Water Apr1990 Sr-89 17.9+/-5.5 23.1+/-8.7 8.7 Sr-90 19.4+/-2.5 23.5+/-5.2 5.2 QC-MI-29 Mille Apr1990 1-131 90.7+/-9.2 82.5+/-8.5 10.4 Cs-134 18.3+/-1.0 19.7+/-5.0 8.7 Cs-137 20.3+/-1.0 18.2+/-5.0 8.7 QC-W-62 Water Apr1990 Co-60 8.7+/-0.4 9.4+/-5.0 8.7 Cs-134 20.0+/-0.2 19.7+/-5.0 8.7 Cs-137 28.7+/-1.4 227+/-5.0 8.7 A-24
Table A-3. In-house spiked samples (continued.) Lab Sample Date Expected. Code Type Collected. Analysis Known Precision 2s, n=3a Activity ls, n=3a QC-W-63 Water Apr 1990. 1-131 63.5+/-8.0 66.~.7 11.4 QC-W-64 Water Apr1990 H-3 1941+/-130 1826.0+/-350.0. 724 QC-W-65 Water Jun 1990 Ra-226 6.4+/-0.2 6.9+/-1.0 1.8 QC-W-66 Water Jun 1990 u 6.2+/-0.2 6.~.o 10.4 QC-MI-30 Milk Jul 1990 Sr-89 12.8+/-0.4 18.4+/-10.0 8.7 Sr-90 18.2+/-1.4 18.7+/-6.0 5.2 Cs-134 46.0+/-1.3 49.0+/-5.0 8.7 Cs-137 27.6+/-1.3 25.3+/-5.0 8.7 QC-W-68 Water Jun 1990 Gr. alpha 9.8+/-0.3 10.6+/-6.0 8.7 Gr. beta 11.4+/-0.6 11.3+/-7.0 8.7 QC-MI-31 Milk Aug1990 1-131 68.8+/-1.6 61.4+/-12.3 10.4 QC-W-69 Water Sep 1990 Sr-89 17.7+/-1.6 19.2+/-10.0 8.7 Sr-90 13.9+/-1.6 17.4+/-10.0 5.2 QC-MI-32 Milk Oct 1990 1-131 34.8+/-0.2 32.4+/-6.5 8.7 Cs-134 25.8+/-1.2 273+/-10.0 8.7 Cs-137 25.3+/-2.0 22.4+/-10.0 8.7 QC-W-70 Water Oct 1990 H-3 2355+/-59 2276+/-455 605 QC-W-71 Water Oct 1990 l-131 55.9+/-0.9 51.8+/-10.4 10.4 QC-W-73 Water Oct 1990 Co-60 18.3+/-2.7 16.8+/-5.0 8.7 Cs-134 28.3+/-2.3 27.0+/-5.0 8.7 Cs-137 22.7+/-1.3 22.4+/-5.0 8.7 QC-W-74 Water Dec1990 Gr. alpha 21.4+/-1.0 26.1+/-6.5 11.3 Gr. beta 25.9+/-1.0 22.3+/-5.6 8.7 a n=3 unless noted otherwise. b n=2 c n=1 d Concentration in pCi/mL A-25
Table A-3. In-house spiked samples (continued) Concentration in pCi/L lab Sample Date TIML Expected Ccxie Type Collected Analysis Result Known Precision 2s, n=l e Activity ls, n=l e QC-MI-33 Milk Jan 1991 Sr-89 20.7+/-3.3 21.6+/-5.0 5.0 Sr-90 19.0+/-1.4 23.0+/-3.0 3.0 Cs-134 22.2+/-1.7 19.6+/-5.0 5.0 Cs-137 26.1+/-1.6 22.3+/-5.0 5.0 QC-MI-34 Milk Feb 1991 1-131 40.7+/-1.8 40.1+/-6.0 6.0 OC-W-75 Water Mar 1991 Sr-89 18.8+/-1.5 23.3+/-5.0 5.0 Sr-90 16.0+/-0.8 17.2+/-3.0 3.0 OC-W-76 Water Apr 1991 1-131 56.5+/-1.7 59.0+/-5.9 5.9 QC-W-77 Water Apr1991 Co-60 16.4+/-2.2 15.7+/-5.0 5.0 Cs-134 23.8+/-2.5 22.6+/-5.0 5.0 Cs-137 25.0+/-2.4 21.1+~.o 5.0 OC-W-78 Water Apr 1991 H-3 4027+/-188 4080+/-408 408 QC-MI-35 Milk Apr1991 I-131 48.0+/-0.8 49.2+/-6.0 6.0 Cs-134 19.2+/-2.0 22.6+/-5.0 5.0 Cs-137 22.8+/-2.2 22.1+/-5.0 5.0 QC-W-79 Water Jun 1991 Gr. alpha 7.4+/-0.7 7.8+/-5.0 5.0 Gr. beta 11.0+/-0.7 11.0+/-5.0 5.0 QC-MI-36 Milk Jul 1991 Sr-89 28.1+/-2.1 34.0+/-10.0 5.0 Sr-90 11.6+/-0.7 11.5+/-3.0 3.0 1-131 14.4+/-1.9 18.3+/-5.0 5.0 Cs-137 34.3+/-3.0 35.1+/-5.0 5.0 QC-W-80 Water Oct1991 Sr-89 27.4+/-6.9 24.4+/-5.0 5.0 Sr-90 11.7+/-1.4 14.1+/-5~0 3.0 QC-W-81 Water Oct 1991 I-131 19.1+/-0.7 20.6+/-4.2 6.0 QC-W-82 Water Oct 1991 Co-60 22.6+/-2.7 22.1+/-5.0 5.0 Cs-134 15.5+/-1.8 17.6+/-5.0 5.0 Cs-137 17.5+/-2.1 17.6+/-5.0 5.0 QC-W-83 Water Oct 1991 H-3 4639+/-137 4382+/-438 438 QC-MI-37 Milk Oct 1991 I-131 23.6+/-3.2 25.8+/-5.0 6.0 Cs-134 22.7+/-2.8 22.1+/-5.0 5.0 Cs-137 38.3+/-3.0 35.1+/-5.0 5.0 QC-W-84 Water Dec 1991 Gr. alpha 6.2+/-0.6 7.8+/-5.0 5.0 Gr. beta 11.0+/-0.7 11.0+/-5.0 5.0 A-26
Table A-3. In-house spiked samples (continued) L1b Sample Date Expected Code Type Collected Analysis Known Precision 2s, n=t e Activity ts, n=l e QC-MI-39 Milk Jan 1992. Sr-89 21.6+/-6.5 31.2+/-10.0 5.0 Sr-90 38.7+/-1.8 42.3+/-8.5 42 1-131 76.8+/-0.9 83.7+/-16.0 8.4 Cs-134 42.1+/-5.7 49.4+/-10.0 5.0 Cs-137 55.2+/-6.4 53.0+/-10.0 5.0 QC-W-85 Water Mar1992 Sr-89 26.2+/-3.t 32.0+/-10.0 5.0 Sr-90 24.4+/-1.4 28.0+/-6.0 3.0 QC-W-86 Water Aprl992 H-3 4080+/-190 4027+/-403 403 QC-W-87 Water Aprt992 1-131 33.5+/-0.6 33.2+/-12.0 6.0 QC-W-88 Water Apr1992 Co-60 17.5+/-2.7 19.7+/-10.0 5.0 Cs-134 28.9+/-2.5 33.5+/-10.0 5.0 Cs-137 41.0+/-3.0 . 38.9+/-10.0 5.0 QC-MI-40 Mille Apr1992 Cs-134 58.0+/-2.6 55.9+/-10.0 5.0 Cs-137 43.7+/-3.0 38.9+/-10.0 5.0 QC-W-41 Mille Apr1992 1-131 50.3+/-0.8 55.9+/-11.2 5.6 QC-W-89 Water Jun 1992 Gr. alpha 15.3+/-0.8 13.6+/-10.0 5.0' Gr. beta 17.2+/-0.9 17.6+/-10.0 5.0 QC-MI-42 Mille Aug.1992 Sr-89 41.4+/-5.9 51.2+/-10.2 5.0 Sr-90 48.9+/-2.5 51.9+/-10.4 52 Cs-134 20.1+/-2.8 20.2+/-10.0 5.0 Cs-137 26.2+/-2.7 26.1+/-10.0 5.0 QC-W-90 Water Sept. 1992 Sr-89 6.7+/-3.4 12.6+/-10.0 5.0 Sr-90 16.1+/-1.4 15.6+/-6.0 3.0 QC-W-91 Water Oct. 1992 1-131 34.9+/-2.2 34.9+/-10.0 6.0 QC-W-92 Water Oct. 1992 Co-60 11.4+/-1.9 9.2+/-10.0 5.0 Cs-134 18.7+/-2.3 14.3+/-10.0 5.0 Cs-137 14.1+/-1.8 15.0+/-10.0 5.0 A-27
Table A-3. In-house spiked samples (continued) Concentration in pCi/L lab Sample r::>ate TIML Expected Code Type Collected Analysis Result Known Precision 2s, n=l e Activity ls, n=l e QC-W-93
- Water Oct. 1992 H-3 3704+/-186 3904+/-390 367 QC-W-94 Water Oct. 1992 H-3 14,925+/-339 15;616+/-1,562 1562 QC-W-95 Water Oct. 1992 1-131 64.2+/-27 67.2+/-10.0 6.7 QC-MI-43 Milk Oct. 1992 1-131 19.9+/-1.0 21.5+/-6.0 6.0 Cs-134 14.2+/-3.4 127+/-10.0 5.0 Cs-137 14.1+/-5.2 17.1+/-10.0 5.0 QC-MI-44 Milk Oct. 1992 1-131 36.1+/-1.2 43.0+/-10.0 6.0 Cs-134 28.2+/-4.0 25.4+/-10.0 5.0 Cs-137 38.8+/-5.1 34.2+/-10.0 5.0 e Starting in January 1991, all determinations are single.
A-28
j1 Table A-4. In-house "blank" samples. ~oncentrntiQn {~iLLl Acceptance L1b Sample Date Results Criteria Code Type Collected Analysis (4.66 a) (4.66 CJ) SPS-5386 Milk Jan *1988 I-131 <0.1 <1 SPW-5448 "Dead" Water Jan 1988 H-3 <177 <300 SPS-5615 Milk Mar1988 Cs-134 <2.4 <10 Cs-137 <2.5 <10 I-131 <0.3 <1 Sr-89 <0.4 <5 Sr-90 24+/-0.5a <1 SPS-5650 D.I. Water Mar 1988 Th-228 <0.3 <1 Th-230 <0.04 <1 Th-232 <0.05 <1 U-234 <0.03 <1 U-235 <0.03 <1 U-238 <0.03 <1 Am-241 <0.06 <1 Cm-241 <0.01 <1 Pu-238 <0.08 <1 Pu-240 <0.02 <1 SPS-6090 Milk Jul 1988 Sr-89 <0.5 <1 Sr-90 1.8+/-0.5 <1 I-131 <0.4 <1 Cs-137 <0.4 <10 SPW-6209 Water Jul 1988 Fe-55 <0.8 <1 SPW-6292 Water. Sep 1988 Sr-89 <0.7 <5 Sr-90 <0.7 <1 SPS-6477 Milk Oct 1988 I-131 <0.2 <1 Cs-134 <6.1 <10 Cs-137 <5.9 <10 SPW-6478 Water Oct 1988 I-131 <0.2 <1 SPW-6479 Water Oct 1988 Co-60 <5.7 <10 Cs-134 <3.7 <10 Cs-137 <4.3 <10 SPW-6480 Water Oct 1988 H-3 <170 <300 A-29
Table A-4. In-house "blank" samples (continued) i L Acceptance lab Sample Date Results Criteria I Code Type Collected. Analysis (4.66 a) (4.66 a) SPW-6625 Water Decl988 Gr. alpha <0.7 <1 Gr. beta <1.9 <4 SPS-6723 Milk Jan 1989 Sr-89 <0.6 <5 Sr-90 1.9+/-0.sa <1 I-131 <0.2 <1 Cs.-134 <4.3 <10 Cs.-137 <4.4 <10 SPW-6877 Water Mar1989 Sr-89 <0.4 <5 Sr-90 <0.6 <1 SPS-6963 Milk Apr1989 I-131 <0.3 <1 Cs.-134 <5.9 <10 Cs.-137 <6.2 <10 SPW-7561 Water Apr 1989 H-3 <150 <300 SPW-7207 Water Jun 1989 Ra-226 <0.2 <1 Ra-228 <0.6 <1 SPS-7208 Milk Jun 1989 Sr-89 <0.6 <5. Sr-90 21+/-0.sa <1 I-131 <0.3. <1 Cs.-134 <6.4 <10 Cs.-137 <7.2 <10 SPW-7588 Water Jun 1989 Gr. alpha <0.2 <1 Gr. beta <1.0 <4 SPS-7322 Milk Aug 1989 . Sr-89 <1.4 <5 Sr-90 4.8+/-1.oa <1 1-131 <0.2 <1
- Cs-134
<6.9 <10 . Cs-137 <8.2 <10 SPW-7559 Water Sep 1989 Sr-89 <2.0 <5 Sr-90 <::0.7 <1 SPW-7560 Water Oct 1989 1-131 <0.1 <1 SPW-7562 Water Oct 1989 H-3 <140 <300 A-30
Table A-4. In-house blank" samples (continued) Concentration CpCi/L) Acceptance rm Sample Date Results Criteria Code Type Collected Analysis (4.66 a) (4.66 a) SPS-7605 Milk Nov *1989 1-131 <0.2 <1 Cs-134 <8.6 <10 Cs-137 <10 <10 SPW-7971 Water Dec 1989 Gr. alpha <0.4 <1 Gr. beta <0.8 <4 SPW-8039 Water Jan 1990 Ra-226 <0.2 <1. SPS-8040 Milk Jan 1990 Sr-89 <0.8 <5 Sr-90 <1.0 <1 SPS-8208 Milk Jan 1990 Sr-89 <0.8 <5 Sr-90 1.6+/-0.sa <i Cs-134 <3.6 <10 Cs-137 <4.7 <10 SPS-8312 Milk Feb 1990 Sr-89 <0.3 <5 Sr-90 1.2+/-0.3a <1 SPW-8312A Water Feb 1990 Sr-89 <0.6 <5 Sr-90 <0.7 <5 SPS-8314 Milk Mar 1990 1-131 <0.3 <1 SPS-8510 Milk May1990 1-131 <0.2 <l Cs-134 <4.6 <10 Cs-137 <4.8 <10 SPW-8511A Water May1990 H-3 <200 <300 SPS-8600 Milk Jul 1990 Sr-89 <0.8 <5 Sr-90 1.7+/-0.6a <1 1-131 <0.3 <1 Cs-134 <5.0 <10 Cs-137 <7.0 <10 SPM-8877 Milk Aug1990 1-131 <0.2 <1 SPW-8925 Water Aug 1990 H-3 <200 <300 A-31
Table A-4. In-house blank" samples (continued) i L Acceptanc lab Sample Date Results Criteria Code Type Collected Analysis (4.66 o) (4.66 o) SPW-8926 Water Augi.990
- Gr. alpha
<0.3 <1 Gr. beta <0.7 <4 SPW-8927 Water Aug 1990 U-234 <0.01 <1 U-235 <0.02 <1 U-238 <0.01 <1 SPW-8928 Water Aug 1990 Mn-54 <4.0 <10 Co-58 <4.1 <10 c~ <2.4 <10 Cs-134 <3.3 <10 Cs-137 <3.7 <10 SPW-8929 Water Aug1990 Sr-89 <1.4 <5 Sr-90 <0.6 <1 SPW-69 Water Sep 1990 Sr-89 <1.8 <5 Sr-90 <0.8 <1 SPW-106 Water Oct1990 H-3 <180 . <300
- I-131
<0.3 <1 SPM-107 Milk Oct1990 1-131 <0.4 <1 Cs-134 <3.3 <10 Cs-137 <4.3 <10 SPW-370 Water Oct1990 Mn-54 <1.7 <10 Co-58 <2.6 <10 c~ <1.6 <10 Cs-134 <1.7 <10 Cs-137 <1.8 <10 SPW-372 Water Dec1990 Gr. alpha <0.3 <1 Gr. beta <0.8 <4 SPS-406 Milk Jan 1991 Sr-89 <0.4 <5 Sr-90 1.8+/-0.4a <1 Cs-134 <3.7 <10 Cs-137 <5.2 <10 SPS-421 Milk Feb 1991 1-131 <0.3 <1 SPW-451 Water Feb 1991 Ra-226 <0.1 <1 Ra-228 <0.9 <1 A-32
'~ Table A-4. In-house "blank" samples (continued) CQn~~ntraUon {~iLL}
- um Sample Date Acceptance Results Criteria Code
- Type Collected Analysis (4.66 a)
(4.66 a) SPW-514 Water Mar 1991 Sr-89 <1.1 <5 Sr-90 <0.9 <1 SPW-586 Water Apr1991 1-131 <0:2 <1 Co-60 <2.5 <10 Cs-134 <2.4 <10 Cs-137 <2.2 <10 SPS-587 Milk Apr1991 1-131 <0.2 <1 Cs-134 <1.7 <10 Cs-137. <1.9 <10 SPW-837 Water Jun 1991 Gr. alpha <0.6 <1 Gr.beta <l.1 <4 SPM-953 Milk Jul 1991 Sr-89 <0.7 <5 Sr-90 0.4+/-0.3a <l I-131 <0.2 <1 Cs-137 <4.9 <10 SPM-1236 Milk Oct1991 1-131 <0.2 <;1 Cs-134 <3.7 <10 Cs-137 <4.6 . <10 SPW-1254 Water Oct1991 Sr-89 <2.8 <5 Sr-90 <0.7 <1 SPW-1256 Water Oct1991 1-131 <0.4 <1 Co-60 <3.6 <10. Cs-134 <4.0 <10 Cs-137 <3.6 <10 SPW-1259 Water Oct1991 H-3 <160 <300 SPW-1444 Water Dec1991 Gr. alpha <0.4 <1 Gr. beta <0.8 . <4 SPM-1578 Milk Jan 1992 Sr-89 <0.5 <5 Sr-90 1.3+/-0.4a <1 1-131 <0.2 <1 Cs-134 <7.2 <10 Cs-137 <8.0 <10 A-33
Table A-4. In-house blank" samples (continued) ~Qn~~ntratiQn {~iLL2 Acceptanc lab. Sample Date Results Criteria Code Type Collected Analysis (4.66 a) (4.66 a) SPW-1860 Water Mar 1992 Sr-89 <0.6 <5 Sr-90 <0.4 <1 SPW-2067 Water Apr 1992 H-3 <168 <300 SPW-2114 Water Apr1992 C-:14 <1.0 <200
- --~
SPW-2119 Milk Apr1992 Co-60 <6.3 <10 Cs-134 . <4.5 <10 Cs-137 <5.4 <10 SPW-2126 Water Apr 1992 I-131 <0.2 <1 SPM-2133 Milk Apr1992 I-131 <0.2 <1 SPW-2220 Water May1992 Co-60 <2.1 <10 Cs-134 <2.1 <10 Cs-137 <2.3 <10 SPW-2369 Water
- Jun 1992 Gr. alpha
<0.4 <1 Gr. beta <0.8 <4 SPM-2500 Milk Aug 1992 I-131 <0.4 <1 Sr-89 <1.2 <5 Sr-90 <0.9 <1 SPW-2666 Water Sept. 1992 Sr-89 <0.8 <5 Sr-90 <0.5 <1 SPW-2828 Water Oct. 1992 Co-60 <4.8 <10 Cs-134 <6.0 <10 Cs-137 <6.1 <10 I-131 <0.3 <1 H-3 <177 . <300 SPM-2829 Milk Oct. 1992 Co-60 <9.3 <10 Cs-134 <6.4 <10 Cs-137 <7.2 <10 SPW-3212 Water Oct 1992 Ra-228 <1.0 <1 SPW-3057 Water NOv. 1992 Ra-226 <0.03 <1 SPW-3294 Water Dec. 1992 Gr. alpha <0.4 <1 Gr. beta <0.8 <4 a Low level of Sr-90 concentration in milk (1-5 pCi/L) is not unusual. A-34
TIML-BLIND-01 Revision 0, 12-29-86 ATIACHMENT B ACCEPTANCE CRITERIA FOR "SPIKED" SAMPLES LABORATORY PRECISION: ONE STANDARD DEVIATION VALUES FOR VARIOUS ANALYSESa Analysis Gamma Emitters Strontium-89 b Strontium-90 b Potassium Gross alpha Gross beta Tritium Radium-226, -228 Plutonium lodine-131, lodine-129b Uranium-238, Nicket-64.b, Technetium-99b Iron-5sb Level 5to100 pCi/liter or kg >100 pCi/liter or kg 5 to SO pCi/liter or kg >50 pCi/liter or kg 2 to 30 pCi/liter or kg >30 pCi/liter or kg >0.1 g/liter or kg <20 pCi/liter >20 pCi/liter <100 pCi/liter >100 pCi/liter <4,000 pCi/liter >4,000 pCi/liter <0.1 pCi/liter 0.1 pCi/liter, gram, or sample <55 pCi/liter >55 pCi/liter <35 pCi/liter >35 pCi/liter SO to 100 pCi/liter >100 pCi/liter One Standard Deviation
- for Single Determination 5 pCi/liter 5% of known value 5 pCi/liter 10% of known value 3.0 pCi/liter 10% of known value 5% of known value 5 pCi/liter 25% of known value 5 pCi/liter 5% of known value ls = (pCi/liter) =
169.85 x (known)*0933 10% of known value 15% of known value 10% of known value 6 pCi/liter 10% of known value 6 pCi/liter 15% of known value 10 pCi/liter 10% of known value a From EPA publication, "Environmental Radioactivity Laboratory Intercomparison Studies Program, Fiscal Year, 1981-1982, EPA-600/4-81-004. bTJML limit A-35
ADDENDUM TO APPENDIX A The following is an explanation of the reasons why certain samples were outside the control limit specified by the Environmental Protection Agency for the Interlaboratory Comparions Program starting January 1988. TIML Result. Uib Code
- Analysis (pCi/L)a STF-524 K
1010.7+/-158.5b STW-532 1-131 9.0+/-2.0 STW-534 Co-60 63.3+/-1.3 STM-554 Sr-90 51.0+/-2.0 STW-560 Pu-239 5~8+/-1.1 STW-568 Ra-228 26+/-1.0 EPA Control Limit (pCi/L)a Explanation 1123.5-1336.5b Error in transference of data. Correct data was 1105+/-33 mg/kg. Results in the past have been within the limits and TIML will monitor the situation in the future. 6.2-8.8 Sample recounted after 12 days. The average result was 8.8+/-1.7 pCi/L (within EPA control limits). The sample was recounted in order to check the decay. Results h1 the past have been within the limits and TIML will continue to monitor the situation in the future. 41.3-58.7 High level of Co-60 was du~ to contamination of beaker. Beaker was discarded upon discovery of contamination. and sample was recounted. Recount results *were 53.2+/-3.6 and 50.9+/-2.4 pCi/L 54.8-65.2 The cause of low result was due to very high fat content of milk. It should be noted that 63% of all
- participants failed this test Also, the average for all participants was 54.0 pCi/L before the Grubb and 55.8 pCi/L after the Grubb.
3.5-4.9 The cause of high results is not known though it is suspected that the standard was not properly calibrated by supplier and is under investigation. New Pu-236 standard was obtained and will be used for the next test. 2.7-4.5 A-36 The cause of low results is not known. Next EPA cross check results were within the control imits. No further action is planned.
ADDENDUM TO APPENDIX A (continued) TIML Result lab Code Analysis (pCi/L) a STM-570 Sr-89 26.0+/-10.0
- Sr-90 45.7+/-4.2 STW-589 Sr-90 17.3+/-1.2 STM-599 K
1300.0+/-69.2C STW-601 Gr. alpha 11.0+/-2.0 STAF-626 Gr. alpha 38.7+/-1.2 STW-632 Ba-133 74.0+/-6.9 STM-641 I-131 130.7+/-16.8 STM-661 Sr-89 25.3+/-7.6 EPA Control Limit (pCi/L)a Explanation 30.3-47.7 The cause of low results was falsely high 49.8-60.2 recovery due to suspected incomplete. calcium removal. Since EPA sample was used up, internal spike was*; prepared and analyzed. The results were within control limits (See table A-3, sample QC-MI-24). No further action is planned. 17.4-22.6 Sample was reanalyzed in triplicate; results of reanalyses were 18.8+/-1.5 pCi/L. No further action is planned. 1414.7-1685.3c Sample was reanalyzed in triplicate. Results of reanalyses were 1421.7+/-95.3 mg/L. The cause of low results was using wrong volume. 11.6-324 Sample was reanalyzed in triplica Results of reanalyses were 13.4+/-1. pCi/L 14.6-35.4 The cause of high results is the difference 51.6-72.4 88.9-127.1 29.3-46.7 A-37 in geometery between standard used in the TIML lab and EPA filter. Sample was :reanalyzed. Results of the reanalyseswere 63.8+/-6.9 pCi/L within EPA limit. The cause of high result is unknown. In-house spike sample was prepared with activity of I-131 68.3+/-6.8 pCi/L Result of the analysis was 69.1+/-9.7 pCi/L The cause of low result is unknown.* Data was checked for errors. The In-house. spike sample was prepared with activity of Sr-89 41.0+/-10.0 pCi/L Result of the analysis was 37.2+/-3.* pCi/L
LlibCode STM-673 ADDENDUM TO APPENDIX A (continued). TIML Result . Analysis (pCi/L)a K 1540.0+/-103.9C EPA Control Limit (pCi/L)a Explanation 1597.3-1902.7 Activity was calculated using the wrong volume (3.5 L), instead of 3.25 L. Correction for volume resulted in a value of 1660.0+/-110.1 mg/L; within EPA control limits. a Reported in pCi/L unl~ otherwise noted. c Concentrations are reported in mg/L. A-38
APPENDIXB DATA REPORTING CONVENTIONS B-1
Data Reporting Conventions 1.0. All activities except gross alpha and gross beta are decay corrected to collection time or the end of the collection period. 2.0. Single Measurements Each single measurement is reported as follows: x+/-s where x =value of the measurement; s = 2a counting uncertainty (corresponding to the 95% confidence level). In cases where the activity is found to be below the lower limit of detection L it is reported as <L where L =the lower limit of detection based on 4.66a uncertainty for a background sample. 3.0. Duplicate analyses 3.1 Individual results: Reported result: Xt +/-St Xt+/-s2 x+/-s where x = (1/2) Cxt +/-xv
- =(1/2) F 3.2. Individual results:
<Lt <L2 ReJ>Orted result: <L where L = lower of Lt and L2 3.3. Individual results: x +/- s <L Reported result: x+/-s if x~L; <L otherwise B-2
4.0. Corr:nputation of Averages and Standard Deviations 4.1 A'\\verages and standard deviations listed in the tables are computed from awl of the individual measurements over the period averaged; for exxa.mple, an annual standard deviation would not be the average of q~uarterly standard deviations. The average x and standard deviation(s) ot:f a set of n ntllJ!bers x1, x2... Xn are defined as follows: 1 x=- 'C"x n~* .yr.{x-X)2 S= 1 n-4.2 Values below the highest lower limit of detection are not included in thee average. 4.3 H aall of the values in the averaging group are less than the highest LLD, thee highest LLD is reported. 4.4 H :i:ill but one of the values are less them the highest LLD, the single valwe x and associated two sigma error is reported. 4.5 In m>unding off, the following rules are followed: 4.S.:l. H the figure following those to be retained is less than 5, the figure is dropped, and the retained figures are kept unchanged. As an example, 11.443 is rounded off to 11.44. 4.5.2 H the figure following those to be retained is greater than 5, the figure is dropped and the last retained figure is raised by 1. As an example, 11.446 is rounded off to 11.45. 4.5.3.. H the figure following those to be retained is 5, and if there are no figures other than zeros beyond the five, the figure five is dropped, and the last-place figure retained is increased by one if it is an odd number or it is kept unchanged if an even number. As an example, 11.435 is rounded off to 11.44, while 11.425 is rounded off to 11.42 B-3
1992 PALISADES AIR PARTICULATE_ Weekly Gross Beta Grand Rapids-Control vs Tower Hill, H Soderberg, J Sarno 0.055 0.050 0.045 !.... 0.040 r © Q) 0.035 2
- 0 0.030
...0
- .> u 0.025
- - 0.020 u
Q_0.015 0.010 0.005 0.000 JAN FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC M 0 NTH
- *
- Tower Hi 11 5 SSE -+ - H Soderberg 5 SE -*- J Sarno 3. 5 ESE ---e-G. R. -C 5 5 N NE
1992 PALISADES AIR PARTICULATE __ Weekly Gross Beta Kalamazoo-Control vs Township Park, State Park 0.055 0.050 0.045 !.... 0.040 Cl) © 0.035 2
- 0 0.030
..0 8 0.025
- - 0.020 u
o._0.015 0.010 0.005 \\. ~
- \\ '*
I*
- '+
P I \\ I, \\* \\, i I
- 0.000--i--~-~-~--~-~-~-~-~-~-~~
JAN FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC M 0 NTH
- *
- State Park 1 N -*- Township Park 1.5 S -e-Kalamazoo-C 35 E
1992 PALISADES AIR PARTICULATE.- Weekly Gross Beta Dowagiac-Control vs Sherman Dairy, R Bus, P Rood 0.055 0.050 0.045 I.... 0.040 CD © 0.035 2
- 0 0.030
..0
- J u 0.025
- - 0.020 u
0.. 0.015 0.010 I J I I I 0.005 0.000 JAN FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC M 0 NTH
- *
- P Rood 3 E -*- R Bus 4. 75 NE
- Sh Dairy 7.5 NNE -+- Dowagiac-C 39 SSE
~-----*- H 0. 1 0
- 0. 0 9
©o.os ~ CJ) s
- 0. 0 7 0.06
.~ 0. D 5 ~
- 10.04
() "0.03
- ~ u 0. 02 Pi 0.01 Palisades Air Particulate Gross Beta Pre-Operational vs.* Operational 0. 0 0 -!--~ll.llll--....a::.~.D...1-~~,
lill---~~L---J1LL4 ..u..u.L-------i::.L~Ul-.--t:LL.o;lilll-'L--, Pre-Op 1987 1988 1989 1990 1991 199 2 1968-1969 Y E A
- R
~Kalamazoo
- Site -- Kalamazoo Trend* -- Site Trend*
- Least Squares Best-Fit line
_I 1992 PALISADES LAKE WATER SAMPLES Gross Beta pCi/L 5.00 4.50 4.00 3.50 3.00 Ludington & South Haven Treated & Raw-Contrc>ls vs Intake '-..... u 2.50 0... 2.00 1.50 1.00 0.50 0.00 JAN FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC M 0 NTH -Iii-Intake Ludington_:__Control --B7-Treated-Control --e-Raw-Control
4.0 3.5 3.0 ~ Q) 2. 5 ~
- Fl
-:::2.0
- Fl u
~ 1. 5 1. 0
- 0. 5 Palisades Lake Water Gross Beta 1987
= 1992 1987 1 9 8 8 1 9 8 9 1990 1991 199 2 y E A R 111 nt ake ~ Discharge ~ Raw kt:::fl Treated - Intake - - - Discharge - - Raw
- * *
- Treated Trend*
Trend* Trend* Trend*
- Least Squares Best-Fit line
- ~~~~-
1992 PALISADES WELL WATER SAMPLES 12 1 1 10 9 8 -' 7 ~ 6 u 0... 5 Gross Beta pCi/L Ludington-Control vs Township Park, State Park, Site and Outage Building J JAN FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC M 0 NTH
- Site -o-St Park -BJ-Twp Park ---e-Ludington-Ctr! -*-Outage Building
1992 PALISADES WELL W.ATER SAMPLES 12 1 1 10 9 8 4 3 2 Gross Beta pCi/L Ludington-Control vs Warehouse, Well* #14~ Well #15 and Well #16 ,.Q / J I I I I / ~ '0 _ _ _ -- -- ~ _ _ I \\ -. - -v J
\\ +- --
I \\, ~ I ', ~ I \\ I '© ' ej I 1 *...... *...... ...... *** :: ~ /. 0 Q-1-~~~~~~~~~~~~~~~~~~~~~ JA~~ FEB MAR /1,PR MAY JUN JUL AUG SEP OCT M 0 NTH
- ** Lu din gton-Ctrl -o-Whse ---te- # 14 -e-- # 15 -*- # *15 NOV DEC
i::: Ji::: J.
- 5. 0 4.5 4.0
~ 3. 5 +I
- Fl 3. 0 f=l
""2 5
- Fl u
°'42.0-1. 5 1. 0 0.5 Palisades Well Water Gross Beta Pre~Operational vs. Operational 0. 0 --1---------l:L:'.A.--____J Pre-Op 1 g 8 7 1988 198 9 1 9 9 0 1 g g 1 1g9 2
- Least 1968-1969 Sq urn-es y
E A R Best-Fit Twp Pk ~Site Avg ~St Pk - Twp Pk Trend* - - - Site Trend* - - St Pk Trend* line
1992 PALISADES MILK SAMPLES Sr-90 pCi/L Shine-Control vs Hessey, Crnkovich, Kemp 10 9 8 7 6 2 1 o~~~-~--.-~-y-~-.-~-.-~--.-~~~--,-~--r~--,~--, JAN FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC M 0 NTH
- *
- Hessey -+- Kemp -e-Shine-Control --ii-Crnkovich
--*~~~~~*~~~~ Palisades Mill{ Sr~90 1 0 9 8 7 3 2
- Pre~Operational vs. Operational 0 --+-----f-""~-~~-f:.L..<:~~~.l.lD...l_~~:u.l.l~:::L,4.l...D~~~~
- Least Pre-Op 1987 1988 1989 1990 1968-1969 Y
E A R 199 2 Squares Best-Fit line ~Near Site
- Control Near Site Trend* -- Control Trend*
24 22 20 1 8 ~ 1 6 Q.) ~ 14 i=i "12
- r=l Cj 1 0
°'1 8 6 4 2 1 Palisades Milk Cs-137 Pre~Operational vs. Operational
LLD Reporting Lim i t O-+-~~~~~_..,~~~,lll-~~~~~~*~--,
Pre-Op 1987 1988 1989 1990 1991 1992 1968-1969 -y E A R ~Near Site ~Control
- 10 9
8 7 6 E Q) 1992 PALISADE:s TLD's ST10 Control vs ST06, ST07 A, ST08 . -~(.
- ,.*---+.
f
- ...... -~._._.
~/_. -,-*- \\ /
- = 5
,,.I ~
- =
~ 3 2 1 Q-1-~~~~~~~~~~~~~--~~~~~~~~~ JAN FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC M 0 NTH
- ST-06 4.75 NE -+- ST-07A 4. 75 NNE -Ii-ST-08 1 N ST-1 OC 55 NNE
10 9 8 7 6 2 1 1992 PALISADES TLD's ST 11 Control vs ST05, ST23, ST24 Q-1-~~~~~~~~~~~~~~~~~~~~~~ JAN FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC M 0 NTH
- ST-05 3 E _._ ST-11 C 35 E -+- ST-23 3 ENE -ii-ST-24 4.5 E
E (I) 10 9 8 7 6 1992 PALISADE:s TLD's ST10 Control vs ST13, ST14, ST15
- = 5
- =
~ 2 1 o--l-~-r-~-.-~~~-.-~-.---~-.-~*--r-~--.~--r~--.~--. JAl\\l FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC M 0 NTH ST-10C 55 NNE ** ST-13 0.9 NNE -+- ST-14 0.9 ENE -Ii-ST-15 1.3 ENE
E Cl) 1992 PALISADES TLD's ST11 Control vs ST01, S1 116, ST17, ST18 10 9 8 7 6
- = 5
~ '*-*----~.::::::-** _,_.;..- --**.::: '--._ /.-!!- 4 . '.,-;,.. ~ .... /.. ;m* '+-.- "~ ~ 1- .. **'..,,.~ */~-,:-.<
- ..-?'. /
/' '>\\ - * ~ /t / / _,A.'* -.. I \\ "/* '~--~ : '..-- / I A_/. 3 I \\ / \\ "~11111/ I '-~ _ _-Jr-~
- ~
I / \\ I 2 1 Q-r-~~~~~~~~~~~~~~~~~---.-~~~--, JAN FEB MAR APR MAY JUN JUL AUG SEP OCT NOV . DEC M 0 NTH
- ST-01 0.3 ESE
- ST-11C 35 E -+-ST-16 1.5 E -Ii-ST-17 1 ESE -.... ST-18 1 SE
1992 PALISADES TLD's ST12 Control vs ST02, ST03, ST04, ST09 10 9 8 2 1 Q-1-~~~~~~~~~~~~~~-~~~~~~~~~~ JAN FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC M 0 NTH
- ST-02 5 SSE -+- ST-03 5 SE -w-ST-04 3.5 SE _...._ ST-09 1.5 S __._ ST-12C 30 SSE
10 9 8 7 6 E (]) 1992 PALISADES TLD's ST12 Control vs ST19, ST20, ST21
- = 5
- =
- 2:
3 2 1 0-*r--~.--~r--~.--~.------~~~-r-----r-"-~-,--~-r--~--.----, JAN FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC M 0 NTH ST-12C 30 SSE ** ST-19 0.7 SSE -+- ST-20 0.7 S ST-21 0.6 SSW
10 9 8 7 6 E (]) 1992 PALISADES TLD's ST 10 Control vs ST33 :' ST34, ST35 .:: 5
- =
~ 4 r r 3 / 2 1 Q-1-~~~~~~~~~~~~~~~~~----r~---.~-----, JAi~ FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC M 0 NTH .._ ST-1 OC 55 NNE *
- ST-33 0.9 ENE -+- ST-34 0.9 ENE -ii-ST-35 0.9 ENE
10 9 8 7 6 E (]) 1992 PALISADES TLD's ST 11 Control vs ST36~, ST37, ST38 .~ 5
- =
~ 4 2 1 Q--1-~~~~~~~~~~~~~~~~~~~~-,--~~ JAN FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC M 0 NTH -e-ST-11 C 35 E -* ST-36 0.9 E -+- ST-37 0.9 E -ii-ST-38 0.9 ESE
- l. /j
--------------------~
Palisades Monthly Thermoluminescent Dosimeters 1 1 1 0 g ~ ~ 8 ~ 0 --7 Pre~Operational vs. Operational S 6 Range 5 - 10 s 5 CJ) 4 ~ s 3 2 Pre-Op 1968-1969 198 7 198 8 1989 199 0 1 9 9 1 199 2
- Least Squares Best-Fit line y
E A R Control Trend
- IBWSJ Inner ~
Outer ~ Control - - - Inner Ring -- Outer Ring Ring Ring Trend
- Trend
- Palisades Quarterly Ther:oluminescent Dosimeter~
1987 = 1992 20 1 8 2 ~~~W-L__---==~~"-'--~ >:< L2 ast 1 9 8 7 1 9 8 8 1 9 8 9 1990 1991 199 2 y E A R I§] Inner ~ Outer f:>~~:~ Control Inner Ring -- Outer Ring Ring Ring Trend
- Trend
- Squoi-eS Best-Fit line Control Trend *
--~~~~-*~-~~~- Palisades Annual Thermolun1inescent Dosimeters 1987 = 1992 80 70 1 0 I 0 -l---~~.D...DJ._~~:u.u.u.~~4-\\..ll.Ll---XJ=i.::::~Lt--_J~~.-Dl------'=~llll--~
- Least 1987 1988 1989 y
E lfi[l Inner ~ Outer ~ Control Ring Ring 1 9 9 0 1 9 9 1 1 9 9 2 A R Inner Ring -- Outer Ring Trend
- Trend
- Squa1~es Best-Fit Ii tie Control Trend
- Palisades Sediments Gross Beta 1987
= 1992 26 ~~j x LL ~20 ~ 18 ~ 1 6 d 1 4 ~ 1 2 bl) "10
- F4 u 8
~ 6 4 2 x <) <)
I
e....,.::...:-..:_-~- -.:-1: - ~ - - -.ai- - - - - - - - - - - - :$>_ - - ~- - - - - - - - - - - - - - - - - - - - - - - ~ +
~----,.
.+- + <) +* + x ~:---;-~---]-L~---~-~ x x x x <) Q--1-r-~~~~-r-r--.-~~~~~~~~~~~~~~~~~~~~ 1987 1988 198 9 y E 1 9 9 0 A R 1 9 9 1 199 2 X Site S. Haven + Ludington -- Site ---- S. Haven Ludington
1 3 1 2 1 1 ~ 10 ~ 9 ~ 8 7 s 6 bJ) ""' 5 'Fl u 4 ~ 3 2 1 Palisades Sediments Gross Beta 1987 = 1992 0 ----i::..<::.Ll I ..D...D...l..-~ I ..Ll...l..U--~ I ~__,,....."'--""' 1 u..>..Ut----~
- Least 1 g 9 2 Squares 1987 1988 1989 y
E Best-Fit Ii 11 e 1990 1991 A R ~ Site II South Haven ~ Ludington - - Site Trend* - South Haven Trend* - - - Ludington Trend*
~
- 5. 0 0 4.50
- 4. 0 0
~ 3. 50 t-3.00 S 2. 5 D blJ "2.00
- Fl u 1 '5 0 Pi 1 ' 0 0
- 0. 5 0
+
*~
Palisades Fish Gross Beta 1987 = 1992 + x x ~ + ~ +
- --- x_ t ---"'--~
T fi.....+
5\\ ~ x + + x ~+ ~ + + t + + 1987 1988 + + 1989 y E 199 0 A R X Site + Ludington Site Trend* 1 9 9 1 199 2 L u d i n g t o n T r e n d
- x
- 0. 0 2 4 Palisades Fish Sr-90 1987
= 1992 0.022 + 0.020 + ~o.01s +J ~D.016 "-"'0.014 so.012 ,bJJ 0. 01 0 U0.008 Pl0.006
- 0. 0 0 4
- 0. 0 0 2 x
x x + x + )f + + x + +
~-----~----------
+ x x x x +x + x + + x + x + + ++ + + -~------..- x + + x+ x x x + +
- x x----
- x
- x x
)f + o.ooo-1-,-~~~~~~~~~~~~~~~~~~~~~r-r---r--,----r-,-,----,-..---,-, 198 7 1988 198 9 y E 199 0 A R X Site + Ludington Site Trend* 1 9 9 1 199 2 L u d i n g t o n T r e n d *
,;=...
- 5. 0 0 4.50 4.00
~ 3. 50 ~,3. 00 s
- 2. 50 blJ
""2.00 'Fl u 1. 5 0 ~ 1. 0 0
- 0. 5 0 a
Palisades Fish Gross Beta 1987 = 1992 0. 0 0 -l--~~.illf_______f:L~llll.J_---J:'.:LL:4~_____.~µ..u..u.i..___-t::LL.~.ll--~~llJ_-__,
- Least 1987 1988 1989 1990 1991 199 2 y
E A R ~Site ~Ludington - Site Trend* -- Ludington Trend* Squares Best-Fit line
r----~~~~~*~-~~~-
- 0. 0 3 5
- 0. 0 3 0
?) 0.025
- 0)
~ "'-"' 0. 0 2 0 s bV0.015
- Fl
~0.010
- 0. 0 0 5 P al is ad es Fish Sr*-90 Pre~Operational vs. Operational 0. 0 0 0-1--~--------~._,_,._,,_,.__~~.w....!l--~~....__0£-F_~--"'-~'-'-'-"--~~,,_...__~
- Least Pre-Op 1987 1988 1989 1990 1991 1992 1968-1969 Y
E A R ~Site
- Ludington Site Trend* -- Ludington Trend*
Squares Best-Fit line
0.24 0.22
- 0. 2 0
~o.1 s +J ~ 0. 1 6 "-"0.14 s
- 0. 1 2
~o.1 o u
- 0. 08 P40.06 0.04 0.02
~-----*__;,; Palisades Fish Cs--137 Pre~Operational vs. Operational LLD R e p o r t i n g Lim i t 0. 0 0 -l----fL4---....t::.qlll1L____-JL4~-9':'.'.~L-~1..D..U..----"'~L----~~---. Pre-Op 1987 1988 1989 1990 1991 1992 1968-1969 Y E A R ~Site
- Ludington}}