Text

consumers Power POWERING MICHIGAN'S PROGRESS Palisades Nuclear Plant: 27780 Blue Star Memorial Highway, Covert, Ml 49043 July 16, 1992 Nuclear Regulatory Commission Document Control Desk Washington, DC 20555 DOCKET 50-255 - LICENSE DPR PALISADES PLANT -

1992 INSERVICE INSPECTION REPORT GB Slade General Manager The report of Inservice Inspection for Palisades Plant is attached.

This report is a summary of the inservice inspections completed during the 1992 refueling outage and is submitted in accordance with the ASME Code and 10CFR50.55a(g).

Also attached are the NIS-2 forms completed during the refueling outage.

~~--*

Gerald B Slade General Manager CC Administrator, Region III, USNRC NRC Resident Inspector - Palisades Attachment

,.. *",.,, ("' (' ')

(, u u ~- ) u

-~92072T6o56 92o~i16-----~\\

PDR ADOCK 05000255 G

PDR A CMS' ENERGY COMPANY