Forwards Staff Evaluation on Possible Recriticality Following Large Break Loca.Evaluation Includles BNL Rept on post-LOCA Reflood Criticality Calculations
ML18058A515
Person / Time
Site: Palisades 
Issue date: 06/04/1992
From: Rosalyn Jones
Office of Nuclear Reactor Regulation
To: Newton R
WESTINGHOUSE OPERATING PLANTS OWNERS GROUP
Shared Package
ML18058A514 List:
References
NUDOCS 9206160237
Download: ML18058A515 (1)


Text

,*

Roger Newton Westinghouse Owners Group c/o Wisconsin Electric Power Co.

P. 0. Box 2046 231 W. Michigan St.

Milwaukee, Wisconsin 53201

Dear Mr. Newton:

June 4, 1992

SUBJECT:

POSSIBLE RECRITICALITY FOLLOWING A LARGE BREAK LOCA As a follow up to my staff's recent conversation with you on the subject of possible recriticality following a large break LOCA, we are enclosing a copy of my staff's evaluation on this subject. This evaluation includes the Brookhaven National Laboratory report on Post-LOCA Re flood Criticality Ca lcul at ions.

We look forward to hearing from you further with regard to your plans to address this question.

If you need any additional information, please do not hesitate to contact us.

Enclosure:

As stated DISTRIBUTION Central Files SRXB R/F AThadani RJones TCollins MChatterton

  • MChatterton R/F Sincerely, Isl Robert C. Jones, Chief Reactor Systems Branch Division of Systems Technology

<.1~B:DST.

'"'~~N~~

t,f Lf 1 rz,,--