Docket No. 50-255 Mr. Gerald B. Slade Plant General Manager Pa 1 i s.ades Pl ant Consumers Power.Co~pany 27780 Blue Star Memorial Highway Covert, 'Michigan 49043 *

Dear Mr.* *Slade:

f7

'i April.6, 1992 DISTRIBUTION

~~e NRC & LPDRs PD31 Rdg File MShuttleworth JRajan 7/E/23.

ACRS ( 10)

WShafer RIII BBoger JZwolinski LMarsh BHolian OGC Palisades P/F MGamberoni

SUBJECT:

. PALISADES Pi;~T~- ~AFETY EVALUATION ON THE SEISMIC ANALYSIS OF HIGH

TH{RMAL PERFORMANCE FU~L.DESIGN (TAC NO. M75590) l*.... t J'
  • ~~ <.*'
  • ,:'J;.1:

~*

A corriin.itment -from-. th!=* NRc.. **s Systerriat i c Eva 1 uat ion Program wa*s *to eva 1 uate the Pal'isad~s*Juel ;design"for.. seismic'.,-adequacy.

This.evaluation was performed in "conjunction *w'ith the: developme'n"t. oCan advanced high thermal performance fuel

desig~ fo~ thelPa1isades,Plari~: Cbnsumers Power Company (CPC) letter dated

. *-November 7, 19.~9;- *provides* the methods, models, assumptions, and results of the associ~ted ~nalyses: '-NRe staff and contractor review result~d in the following-*CP.Ccorre~pcinden'ce' re.t'ating to this issue:

~ :

!I!

I R~sponse to' st a.ff que~t ions Seismic;re::anal.ysis and resubmi tta l:: *;

-~ :

August 16, November 16, 1990; April 16, 1991 June 30, 1991 A final meeting between Advanced Nuclear Fuels Corpo-ration and the NRC staff was held in September 1991 to review calculations and resolve remaining issues.

The NRC has completed its review of your submittals and concludes that the high thermal performance fuel assemblies will maintain their structural integrity and functionality if ~ubjected to a safe shutdown earthquake.

A safety evaluation detailing our evaluation is enclosed.

Enclo_sure.: ____ _

Safety Evaluation cc w/enclosure:

See next page

  • SEE PREVIOUS CONCURRENCE OFC
LA:PDIII-1
PM:PDIII~L-~

NAME :MShuttleworth*:BHolian 4J'l'-

DATE : 4/1/92

1 /1:)/92 9204240288'920406 PDR.:ADOCK:.*05000255 P

PDR Sincerely, Original Signed By:

Brian Holian, Project* Manager Project Directorate III-1 Division of Reactor Projects 111/IV/V.

Office of Nuclear Reactor Regulation

EMEB
JRajan*

3/6/92

\\

D:PDIII-1
  • e UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, O.C_. ~

Docket No. 50-255 Mr. Gerald B. Slade Plant General Manager Palisades Plant Consumers Power Company 27780 Blue Star Memorial Highway Covert, Michigan 49043

Dear Mr. Slade:

April 6, 1992

SUBJECT:

PALISADES PLANT - SAFETY EVALUATION ON THE SEISMIC ANALYSIS OF HIGH THERMAL PERFORMANCE FUEL DESIGN (TAC NO. M75590)

A commitment from the NRC's Systematic Evaluation Program was to evaluate the Palisades fuel design for seismic adequacy.

This evaluation was performed in conjunction with the development of an advanced high thermal performance fuel design for the Palisades Plant. Consumers Power Company (CPC) letter dated November 7, 1989, provides the methods, models, assumptions, and results-of,,

the associated analyses.

NRC staff and contractor review resulted in the * --.............

following CPC correspondence relating to this issue:

Response to staff questions Seismic re-analysis and resubmittal August 16, November 16, 1990; April 16, 1991 June 30, 1991 A final meeting between Advanced Nuclear Fuels.Corporation and the NRC staff was held in Septembe~ 1991 to review calculations and resolve remaining issues.

The NRC has completed its review of your submittals and concludes that the high thermal performance fuel assemblies will maintain their structural integrity and functionality if subjected to a.safe shutdown earthquake.

A safety,evaluation detailing our evaluation is enclosed.

Enclosure:

Safety Evaluation cc w/enclosure:

See next page Sincerely, Brian Holian, Project Manager Project Directorate III-1 Division of Reactor Projects III/IV/V Office of Nuclear Reactor Regulation

Mr. Gerald B. Slade Consumers Power Company cc:

M. I. Miller, Esquire Sidley & Austin 54th Floor One First National Plaza Chicago, Illinois 60603 Mr. Thomas A. McNish, Secretary Consumers Power Company 212 West Michigan Avenue Jackson, Michigan 49201 Regional Administrator, Region III U.S. Nuclear Regulatory Commission 799 Roosevelt Road Glen Ellyn, Illinois 60137 Jerry Sarno Township Supervisor Covert Township 36197 M-140 Highway Covert, Michigan 49043 Office of the Governor Room 1 - Capitol Building Lansing, Michigan 48913 Mr. Patrick M. Donnelly Director, Safety and Licensing Palisades Plant 27780 Blue Star Memorial Hwy.

Covert, Michigan 49043 Resident Inspector c/o U.S. Nuclear Regulatory Commission Palisades Plant 27782 Blue Star Memorial Hwy.

Covert, Michigan 49043 Nuclear Facilities and Environmental Monitor Section Office Division of Radiological Health Department of Public Health 3423 N. Logan Street P. 0. Box 30195 Lansing, Michigan 30195 Palisades Plant Gerald Charnoff, P.C.

Shaw, Pittman, Potts &

Trowbridge 2300 N. Street, N.W.

Washington, D.C.

20037 Mr. David L. Brannen Vice President Palisades Generating Company c/o Bechtel Power Corporation 15740 Shady Grove Road Gaithersburg, Maryland 20877 Roy W. Jones Manager, Strategic Program Development Westinghouse Electric Corporation 4350 Northern Pike Monroeville, Pennsylvania 15146