consumers Power POWE RI Nii
.NllCHlliAN'S PROliRESS Palisades Nuclel!r Plant: 27780 Blue. Star Memorial Highway, Covert, Ml 49043.*
March 6, 1992 Nuclear Regulatory Commission Documerit Control Desk Washington, DC 20555 GB Slade Generaf Manager DOCKET 50-255 - LICENSE DPR PALISADES PLANT - CORRECTION TO RESPONSE TO OPEN ITEM FROM INSPECTION REPORT 91016 In our response to an opeh item from NRC Inspection Report No. 91016, dated December 20, 1991, we* forwarded the results of the analysis of a liquid waste sample for gross beta, tritium, Sr-89 and Sr-90.
The letter contained a table showing the analyzed quantities present and. included the units of measurement.
We have found that the results which we forwarded to the NRC contained an error in the measurement units for the Sr-89 and Sr-90 results. The results for the Sr~89 and Sr-90 an~lysis should have been in picocuries per liter (pti/l) versus picocuries per ~illiliter (pCiLml).
The correct~d results are:
Tritium (Hi) 4.33 E-2 µCi/ml Gross Beta 2.05 E-6 µCi/ml Sr-89
. 91.0 pCi/l Sr-90 9.5 pCi/l If you have any questions please contact Mr. John Paver at 616-764-8913, extension 0307.
. ~~
Gerald B Slade General* Manager CC Administrator, Reg~on III, USNRC NRC Resident Inspector - Palisades 9203110032 920306 PDR ADOCK 05000255 0
. PDR A 01{5 ENEl?GYCOMPANV