| Download: ML18058A251 (2) | |
See also: IR 05000255/1992009
Text
Docket No. 50-255
Consumers Power Company
ATTN:
Gerald B. Slade
General Manager
Palisades Nuclear Generating Plant
27780 Blue Star Memorial Highway
Covert, MI *4'9043 .
Dear nr. Slade:
i 1992
This refers tc the routine. safety inspection conducted by Dr. J. E. House of
this office on February 10-13, 1992, of activities at the Palisades Nuclear
.Ger.erating Plant, authorized by NRC Operating License No. DPR-20, and to the
discussion of out findings with Mr. G. B. Slade, Mr. R. M. Rice and others of
your staff at the conclusion of the inspection.
The enclosed copy of our inspection report identifies areas examined during
- the inspection.
Within these areas, the inspection consisted of a selective
examination of procedures and representative records, observations, and
interviews with personnel.
No violations of NRC requirements were identified during the course of this
inspection.
In accordance with 10 CFR 2.790 of the Commission's regulations, a copy of
this letter and the enclosed inspection report will be placed in the NRC
Public Document Room.
We will gladly discuss any questions you have concerning this inspection.
Sincerely,
~~~3o:ggba i;g5g~5s
G
FDR
~:ea~---
L. Robert Greger, Chief
Reactor Programs Branch
Enclosure:
Inspection Report
No. 50-255/92009(DRSS)
See Attached Distribution
n. ,..., I" ,, 4
~' u .) ( i t
.~*:
. - .... *.)
RIII
~use/jr
tf
f(: ~ I
i.,Y--*S
Snell
c ) i .:JI;;:... '
- /' -***
p JI J
Jo~en
3~/5/9~
Consumers Power Company
Distribution*
cc w/enclosure:
David P. Hoffman, Vice Pre~ident
Nuclear Operations
P. M. Denne lly, Safety and
Licensinc Cirector
DCD/DCB ( RioS)
OC/LFDCB.
Resident Inspector, RIII
James R. Padgett, Michigan Public
Service Commission
Michigan Department of
Public Health
P~lisades; LPM, NRR
SRI, Big Rock Point