ML18057B450

From kanterella
Jump to navigation Jump to search
Provides Info Re Mod of Reactor Protective Sys (Rps), Including Rev 0 to Scope Document, Reactor Protection Sys Trip Unit Assembly & RPS Power Supply Assembly Upgrade & RPS Functional Description
ML18057B450
Person / Time
Site: Palisades 
Issue date: 12/26/1991
From: Slade G
CONSUMERS ENERGY CO. (FORMERLY CONSUMERS POWER CO.)
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
Shared Package
ML18057B451 List:
References
NUDOCS 9201060198
Download: ML18057B450 (2)


Text

~O~SM[!1]1]~W~

~[]W~f l'OWERIN&

MICHl&AN'S PROliRESS Palisades Nuclear Plant:

27780 Blue Star Memorial Highway, Covert, Ml 49043 December 26, 1991 Nuclear Regulatory Commission Document Control Desk Washington, DC 20555 DOCKET 50-255 - LICENSE DPR PALISADES PLANT -

GB Slade General Manager INFORMATION CONCERNING MODIFICATION OF THE REACTOR PROTECTIVE SYSTEM The Reactor Protective System (RPS) at the Palisades Plant is being modified to replace aging components, for which replacement parts are difficult to obtain, with newer components.

In addition, the Flow Setpoint Selector Switch, which was used to adjust the High Power and Low Flow trip setpoints in the original RPS configuration but is no longer used, is being removed.

The replacement components are functionally equivalent to the components which they replace, but are of a newer design.

The replacement components do not rely on digital technology.

They are being supplied by the original RPS supplier, Combustion Engineering.

The modification is being performed under the provisions of 10 CFR 50.59 and, therefore, does not require prior NRC approval.

Due to the importance of the RPS on reactor safety, the details of the modification package are enclosed for your information.

The subject modifications to the RPS do not involve changes to the safety analyses or involve addition of any new equipment which must function to accomplish the assumptions of the safety analyses and, therefore, do not involve changes to the Technical Specifications by requiring addition of any Limiting Conditions for Operation or Surveillance Requirements.

The modifications do not create any conflict with the existing Technical Specifications requirements.

The modifications, therefore, do not involve a change in the Technical Specifications. The RPS modifications do not involve an unreviewed safety question, as defined in 10 CFR 50.59.

One existing Technical Specifications surveillance requirement, although still capable of being performed, will no longer be meaningful once the RPS modifications are accomplished.

The subject surveillance requirement concerns verifying the proper settings of trip setpoint potentiometers for non-operating pump combinations.

These potentiometers would not currently be used if three

~\\ '1 A CMS ENERGY COMPANY

~..

/

pump operation was utilized; instead, each channel would be adjusted to the required setting. The RPS modification will remove these potentiometers and the associated switch.

Setpoint changes for different pump combinations will be made by adjusting each channel in turn. A Technical Specifications change request is being prepared which requests removal of this surveillance requirement in order to avoid unnecessary testing of the RPS.

Approval of that Technical Specifications change request is not required in order to operate with the modified RPS. describes the physical and administrative requirements for the replacement components; Enclosure 2 is a Functional Description of the modification.

~~--

Gerald B. Slade General Manager CC:

Administrator, Region III, USNRC NRC Resident Inspector Enclosures