consumers Power POWERING MICHlliAN'S PROliRESS Palisades Nuclear Plant: 27780 Blue Star Memorial Highway, Covert. Ml 49043 December 20, 1991 Nuclear Regulatory Co11111ission Document Control Desk Washington, DC 20555 GB Slade General Manager DOCKET 50-255 - LICENSE DPR PALISADES PLANT - RESPONSE TO OPEN ITEM FROM INSPECTION REPORT 91-016 NRC Inspection Report No.91-016, dated September 11, 1991, documented the results of a routine announced safety inspection in the area of radiological chemistry.
An open item concerning the analysis of a liquid waste sample for gross beta, tritium, Sr-89 and sr~9o was contained in the inspection report.
The results of the analyses performed on a liquid waste sample were recently obtained. The resu 1 ts are as f o*l lows:
Tritium (H~)
Gross Beta Sr-89 Sr-90.
4.33 E-2 µCi/ml 2.05 E-6 µCi/ml 91.0 pCi/ml 9.5 pCi/ml By forwarding these results to the NRC, we consider this open item closed. If there are further questions regarding this matter please contac~ Mr John Paver at 616-764-8913, extension 0307.
~/-)/.k._--_.
Gerald B Slade General Manager CC Administrator, Region III, USNRC NRC Resident Inspector - Palisades A CMS' ENERGY COMPANY