consumers Power
.POWERINli
- MICHlliAN'S PROliRESS Palisades Nuclear* Plant:
27780 Blue Star Mem~rial Highway, Covert, fl/II 49()43 July 29, 1991 Nuclear Regulatory Commissfon Document Control Desk Washi~gton, DC 20555 GB Slade General Manager DOCKET 50-255 - LICENSE DPR-20.~ PALISADES PLANT - RESPONSE TO NRC BULLETIN NO. 89-01, SUPPLEMENT 2: - FAILURE OF. WESTINGHOUSE STEAM GENERATOR TUBE*
MECHANICAL PLUGS NRC Bulletin No. 89-01, dated May 15, 1989 discussed the failure of mechanical tube plugs supplied by Westinghouse that had been installed in nuclear steam generators.
The bulletin requested utilities to provide an act\\on plan to ensure_ that the p 1 ugs would continue to provide ade_quate reactor coo 1 ant pressure boundary integrity. The request presented in NRC Bulletin 89-01 applied to plugs fabricated from specific heats of Inconel 600.
Supplement 1 to the b~lletin was issued on November 14, 1990 and described failures of Inconel 600 mechanical tube plugs supplied by Westinghouse from heats not included in the original bulletin.
Supplement 2 to the bulletin; dated June 28, 1991, requests that actions similar to those requested in the original bulletin be extended to include all Westinghouse plugs fabricated from Inconel 600.
Specifically, Supplement 2 requests the following two actions for which responses are provided.
- Verification of the information provided in Table 2 of the referenced
- Westinghouse report.
Consumers Power Company Response As part of the 1990 Refueling Outage the Palisades Nuclear Plant replaced its steam generators.
The steam generators that were replaced contained th~
referenced Westinghouse mechanical tube plugs.
The new Palisades steam generators contain only Combustion Engineering rolled tube plugs.
A CMS" ENERGY COMPANY
- A statement inditating whether or not the actions in Actions Requested, item 2 have been or will be taken.
Consumers Power Company Response Since there are no Westinghouse Inconel 600 mechanical tube plugs now installed in the Palisades* steam generators, none of the actions in the Actions Requested will be taken.
- ,/"/A.*.
~'P-2<~-
Gera l d B Slade
1:.
. '~"
CONSUMERS POWER COMPANY Palisades Plant*
Docket 50-255 - License DPR-20
- RESPONSE TO NRC BULLETIN 89-01, Supplement 2 At the* request of the Commission-and pursuant to the Atomic Energy Act of 1954 and *the Energy Reorganization Act of 1974, as amended, and the Commission's Rules and Regulations thereunder, Consumers Power Company submits our response to NRC Bulletin 89-01 Supplement 2, dated June 28, 1991, entitled, "FAILURE OF.
WESTINGHOUSE STEAM GENERATOR TUBE MECHANICAL.PLUGS."
CONSUMERS POWER COMPANY To the best of my knowledge, *information and belief, the contents of this submittal.are truthful and complete~
By~
David P Hoffman,. ce Nuclear Opera Sworn and subscribed to before me this 3dtt.aay. of --~-7'1'=-=b-~-
a L/J.A. -
.Beverlyriry
, N~ic Jackson Courity, Michigan My commission expires ~
~ /flt/;i_
'ii 19iG:.
i