June 22, 1990 Docket Nos. 50-255, 50-285, 50-309, 50-317, 50-318, 50-335, 50-389, 50-336,

-~- -*-------.-50~36.L,-50... 362, 50-368, 50... 382, 50-528, 50~529 and 50-530 MEMORANDUM FOR:

THRU:

FROM:

T.Murley B. Grimes F. Miraglia*

F. Congel W. Russe 11, ADT J. Roe J. Partlow, ADP

c. Grimes D. Crutchfield, ADSP B. Boger S. Varga G. Lainas G. Holahan
w. Travers C. Rossi B. D. Liaw J. Richardson E. Butcher John T. Larkins, Acting Director Project Directorate V Division of Reactor Projects - III IV, V and Special Projects James E. Tatum, Project Manager Project Directorate V Division of Reactor Projects - III, IV, V and Special Projects P. McKee A. Thadani EAB/Acting Chief J. Dyer, EDO F. Gillespie W. Bateman T. Cox J. Zwolinski C.

SUBJECT:

FORTHCOMING MEETING WITH COMBUSTION ENGINEERING REGULATORY RESPONSE GROUP By memorandum dated June 21, 1990, you were notified that a meeting has been

.scheduled to discuss CEA failure with the Combustion Engineering Regulatory Response Group (CERRG). to this memo is the current agenda for the meeting. is a tentative list of CERRG attendees. If you have any questions regarding this meeting, please contact me at 21373.

Enclosures:

As stated cc w/o enclosures:*

See next page 9006260023 900622.

PDR ADOCK* 05000255 P

PDC:

(A~D:PDV J ~at k/i'ff s t IZU90 DOCUMENT NAME:

MTG ON CEA FAILURE

/s/

James E. Tatum, Project Manager Project Directorate V Division of Reactor Projects - ill

  • IV, V and Special Projects
  • Docket Nos. 50-255, 50-285, 50-309, 50-317, 50-318, 50-335, 50-389, 50-336,

--~50-361, 362-,-- 50-368,- 50-382, -

50-528, 50-529 and 50-530 MEMORANDUM FOR:

T.Murley B. Grimes F. Congel J. Roe

-THRU:

FROM:

F. Miraglia W. Russell, ADT J. Partlow, ADP D. Crutchfield, ADSP S. Varga G. Holahan C. Rossi J. Richardson

-c. Grimes B. Boger G. Lainas W. Travers B. D. Liaw E. Butcher John T *. Larkins, Acting Director Project Directorate V Division of Reactor Projects ~ III IV, V and Special Projects James E. Tatum, Project Manager Project Directorate V Division of Reactor Projects - III, IV, v*and Special Projects June 22, 1990 P. McKee A. Thadani

_ EAB/Acting Chief J. Dyer, EDO F. Gillespie W. Bateman T. Cox J. Zwolinski'

SUBJECT:

FORTHCOMING MEETING WITH COMBUSTION.ENGINEERING REGULATORY RESPONSE GROUP -

By* memorandum dated June 21, 1990, you were notified that a meeting has been scheduled to discuss CEA failure with the Combustion Engineering Regulatory Response Group (CERRG).

  • Enclosure 1 to this memo is the current agenda for the meeting. Enclosure 2 is a tentative list of CERRG attendees. If you have any questions regarding this meeting, please contact me at 21373.

Enclosures:

As stated

-cc w/o enc lOsures: -

See next page 1~P

/LA/PD5 -

'- _ a tum: sg

!2'7190 (A~D:PDV Jl(af~s t IZU90 DOCUMENT NAME:

MTG ON CEA FAILURE

/s/

James E. Tatum, Project Manager Project Directorate V Division of Reactor Projects ~ III "IV, V and Specia 1 Projects

NUCLEAR REGULATORY COMMISSION

. RRG REPORT -

MAIN -YANKEE CEA Flt:tLURE J'une 25, 1990

.Introduction Backgrsiund C-E Plants, CEA Design, Curren.t Status, and Strain Criteria

. LL Qt1aarvotion1 CEA Stickinq Discovery ot New CEA Failure ~tode M. Y. Inspection Proqram* Statu1.

M.Y. R§!sults and Prelimiparv Int:emDtati~

EOT Results Visual Exam Results Likely Failure Sequence and ca.use Work in Proqress or Planned lme:i~~t~on Other C*E Plante s-so Plants 16x16 Plants 14>e14 Plants

,CQ~l1uiion1 and *Action ttams ENCLOSURE 1 R. Wella (NU)

UQ Chairman R. Youn; (C-E)

c. Whittier* (MY)

D. Whittier (MY)

o. Whittier (MY)

V. Roy (C*E)

  • R. Duncan (C-E)

R. Duncan (C-E}

R. Duncan (C-E)

R. Youn; (C-E).

R. Young (C-B)

R. Youn; (C*!)

R. Wella (NU)

I ENCLOSURE 2 TENTATIVE LIST OF ATT!:NDEES

~;11\\bumtion Engin11ring R. ouncan R. Young R. Freeman E. 'l'rapp J. Baum S. Toelle J. Pfeifer V. Roy L. Corsetti

w. Goodwin

~* Shapiro ys;111sJ.u R. Well* ' M.* Hill* (NU)

J *. Hut~chin*oD (l'P,L) c.-

  • au1~on (FP,L)

B. Kor1t;omery (BG&E)

P. File fBG'!)

R.

Buz~sk (BO-Waterford)

D. WhJ.ttier fMYAPC)

D. Baiitiar ' s. Ryder (APS)

DI~TRIBUTION Oc;t'ket File.

NRC & Local PDRs PD5 -Recfdfrig - - -- -

Acting Chief, EAB OGC-White Flint E. Jordan Receptionist - OWFN NRC Participants ACRS (10)

GPA/PA V. Wilson L. Thomas M. Slosson MS 17621 G. Cook, Region V D. Foster

  • L. Kokajko C. Poslusny S. Peterson T. Chan D. Wigginton B. Holian G. Vissing J. Norris D. McDonald A. Bournia C. Burlinger U. Potapovs

/