ML18054A397

From kanterella
Jump to navigation Jump to search
Forwards Bimonthly Work Order Status Rept for Aug 1988 & Sept 1988.Rept Numbers for Months in Error Corrected So as Not to Include Preventive Maint Work Orders
ML18054A397
Person / Time
Site: Palisades 
Issue date: 10/18/1988
From: Johnson B
CONSUMERS ENERGY CO. (FORMERLY CONSUMERS POWER CO.)
To:
NRC OFFICE OF ADMINISTRATION & RESOURCES MANAGEMENT (ARM)
References
NUDOCS 8810270025
Download: ML18054A397 (2)


Text

' \\

I

\\..t consumers Power l'OWERIN&

NllCHl&AN"S l'RO&RESS General Offices: 1945 West Parnell Road, Jackson, Ml 49201 * (517) 788-0550 October 18, 1988 Nuclear Regulatory Commission Document Control Desk Washington, DC 20555 DOCKET 50-255 - LICENSE DPR PALISADES PLANT -

BI-MONTHLY WORK ORDER STATUS REPORT Consumers Power Company letter dated December 27, 1985 committed *to submitting t~ (

a monthly report during the 1985 Palisades refueling outage and a bi-monthly report thereafter which indicates the total work order backlog, total control room deficiencies, emergent work orders and emergent control room deficien-cies.

By letter dated September 1, 1987, we changed the terms used in the report from Total Work Order Backlog to Corrective Work Order Backlog. It has come to our attention that an error existed in our reporting procedure regarding the number of work orders physically completed and/or awaiting post-op testing.

The numbers given between October 26, 1987 and July 25, 1988, include work orders for Preventive Maintenance.

Since this status report is intended to show the progress on Corrective Work Orders, we have corrected the reported numbers for the months in error so as not to include Preventive Maintenance Work Orders.

This report also provides the Corrective Work Order Backlog and Open Control Room Deficiencies for August 1988 and September, 1988.

Our next.report will cover the months of October and November and will be submitted in December, 1988.

Brian D Johnson Staff Licensing Engineer CC Administrator, Region III, NRC NRC Resident Inspector - Palisades Attachment OC10B8-0174-NL02 8810270025 881018 PDR ADOCK 05000255 R

PDC I

j 0

\\

<(

. ~~-..

e e

CORRECTIVE W.O. BACKLOG

. ',,* \\..J 1987/1988 Physically Completed As of Active and/or Awaiting Total Corrective Month/Da~

Backlog Post OE Testing Work Order Backlog Corrected Corrected Jan 26 676 256 932 Feb 23 638 290 928 Mar 30 653 136 789 Apr 27 769 110 879 May 26 753 98 851 Jun 29 680 78 758 Jul 27 678 90 768 Aug 31 534 60 594 Sep 28 552 48 600 Oct 26 373 508 138 881 511 Nov 30 383 210 66 593 449 Dec 28 336 181 67 517 403 Jan 25 320 416 137 736 457 Feb 29 389 207 37 596 426 Mar 30 403 111 26 514 429 Apr 25 411 146 46 557 457 May 30 414 134.

35 548 449 Jun 27 371-160 49 531 420 Jul 25 396 140 32 536 425 Aug 29 302 45 347 Sep 26

,265 104 369 OPEN CONTROL EMERGENT CORRECTIVE W.O.

ROOM DEFICIENCIES 1987/1988 1987/1988 Month Emergent W.O.

Month/Day Total During Month Jan 292 Jan 27 14 12 Feb 318 Feb 23 15 7

Mar 332 Mar 30 6

8 Apr 306 Apr 27 14 9

May 288 May 26 13 9

Jun 240

/'

Jun 30 14 7

Jul

' 244 Jul 29 18 8

Aug 184 Aug 24 15 4

Sep 175 Sep 28 14 4

. Oct 234 Oct 26 7

8 Nov 272 Nov 30 9

5 Dec 163 Dec 15 7

4

  • Jan 200 Jan 30 6
4.

Feb 184 Feb 29 6

4 Mar 131 Mar 30 9

2 Apr 171 Apr 25 12 9

\\.

May 132 May 30 9

6 Jun 77 Jun 27 14 9

Jul 89 Jul 25 13 0

\\

Aug 129 Aug 26 12 2

Sep 151 Sep 30 13 4

OC10.88-0l 74-NL02