Responds to 880421 Request to Reevaluate Thermal Degradation of 2,400-volt Bus Feeder Cables.Util Concludes That Feeder Cable Has Useful Life of 9.9 Yrs Beyond 880516. Cable Safety Significance Will Be Reduced When Mod Done
ML18054A309
Person / Time
Site: Palisades 
Issue date: 05/25/1988
From: Berry K
CONSUMERS ENERGY CO. (FORMERLY CONSUMERS POWER CO.)
To:
NRC OFFICE OF ADMINISTRATION & RESOURCES MANAGEMENT (ARM)
References
NUDOCS 8806020335
Download: ML18054A309 (1)


Text

consumers Power POWERINli MIUllliAN-S PIUlliRESS General Offices: 1945 West Parnall Road, Jackson, Ml 49201 * (517) 788-1636 May 25, 1988 Nuclear Regulatory Commission Document Control Desk Washington, DC 20555 DOCKET 50-255 - LICENSE DPR PALISADES PLANT -

RESPONSE TO APRIL 21, 1988 REQUEST TO REEVALUATE THERMAL DEGRADATION OF 2400 VOLT BUS FEEDER CABLES Kenneth W Berry Director Nuclear Licensing NRC letter, dated April 21, 1988 requested Consumers Power Company to reevaluate the thermal degradation that may have occurred to feeder cables to non-safeguards Bus IE.

The request also stated that the reevaluation should be consistent with Arrhenius methodology.

Consumers Power Company has performed a detailed analysis to determine the useful life of the Bus lE feeder cable from the Station Power Transformer based on the Arrhenius Methodology.

The conclusion, based on this analysis, is that the feeder cable has a useful life of 9.9 years beyond May 16, 1988.

The safety significance of this particular cable will be reduced when the Palisades Plant Modification to improve Off site Power Reliability is completed.

This modification is scheduled to be installed during the 1988 refueling outage, see September 24, 1987 submittal.

The planned modification will place reduced reliance on the referenced feeder cable as a backup to the normal electrical supply.

Therefore the useful life greatly exceeds the period that reliability is.required.

The analysis is included as an attachment to this letter.

Kenneth W Berry Director, Nuclear Licensing CC Administrator, Region III, NRC NRC Resident Inspector - Palisades Attachment OC0588-0021-NL04 n

806020335 880525 DR ADOCK 05000255 P