..,.c.
consumers Power POWERllllli 11/tlCHlliAlll"S PROlillE5S General Offices:
1945 West Parnell Road, Jackson, Ml 49201 * (517) 788-1636 September 15, 1988 Nuclear Regulatory Commission Document Control Desk Washington, DC 20555 DOCKET 50-255 - LICENSE DPR PALISADES PLANT -
Kenneth W Berry Direc"tor Nuclear Licensing TECHNICAL SPECIFICATIONS CHANGE REQUEST -
CONTAINMENT ISOLATION SYSTEM Enclosed is a change to the Palisades Technical Specifications. This change is a result of Consumers Power Company's commitment made in the revised response to Inspection Report 88-008 dated September 2, 1988.
The requested Technical Specification Change incorporates a Containment Isolation Valve Specification which allows for the manual operation of the penetration 33 isolation valves at power for the purpose of sampling Safety Injection Tanks.
This requested change addresses and resolves applicable Standard Technical Specifications requirements and includes a containment isolation valve table as part of the change.
In addition to the penetration 33 valves, the table includes all containment isolation valves needed to isolate upon receipt of containment high radiation (CHR) or containment high pressure (CHP) signals.
The change request has been determined to involve an unreviewed safety question, but an analysis of no significant hazards considerations has been performed and the change has been found to involve no significant hazards considerations.
Consumers Power Company recognizes that numerous Technical Specifications Change Requests, required prior to start-up of the Palisades Plant, have been recently submitted..
This change request could also fall into that category.
However, if approval of the Technical Specification Change Request can not be given due to the work load schedule, we will continue to operate as we have in the past, regarding the sampling of the Safety Injection tanks, since the opening of manual containment isolation valves of penetration 33 for the purpose of Safety Injection Tank sampling was found to involve no significant hazards considerations.
A check for $150.00 is included as required by 10CFR170.12.
'1~_V'4 Kenneth W Berry Director, Nuclear Licensing CC Administrator, Region III, NRC NRC Resident Inspector - Palisades Attachment OC0988-0129-NL02,-
~-
\\
)072 880915 aso92o<
05000255 PDR.
ADOCK PDC p