ML18053A531

From kanterella
Jump to navigation Jump to search
Requests Withdrawal of 880819 Tech Spec Change Request Re Primary Coolant Pump Upper Flywheel Exam Due to Administrative Error & Lack of Sufficient Technical Justification
ML18053A531
Person / Time
Site: Palisades 
Issue date: 08/25/1988
From: Berry K
CONSUMERS ENERGY CO. (FORMERLY CONSUMERS POWER CO.)
To:
NRC OFFICE OF ADMINISTRATION & RESOURCES MANAGEMENT (ARM)
References
NUDOCS 8808300314
Download: ML18053A531 (1)


Text

~*., *-.*.:;..,.

.. IF consumers Power l'OWERINli MICHlliAN'S l'ROlillED General Offices:

1945 West Parnell Road, Jackson. Ml 49201 * (517) 788-1636 August 25, 1988

.r Nuclear Regulatory Commission Document Control Desk Washington, DC 20555 DOCKET 50-255 - LICENSE DPR PALISADES PLANT -

Kenneth W Berry Director Nuclear Licensing WITHDRAWAL OF TECHNICAL SPECIFICATIONS CHANGE REQUEST - PRIMARY COOLANT PUMP UPPER FLYWHEEL EXAMINATION WAIVER Consumers Power Company requests withdrawal of -*the Technical Specification Change Request concerning the Primary Coolant Pump Upper Flywheel Examination.

Due to an administrative error, the subject change, submitted on August 19, 1988, was without the required concurrence by the Nuclear Safety Board Chairman.

Subsequent to the submittal, our Nuclear Safety Board determined the change request lacked sufficient technical justification and the 10CFR50.59 evaluation did not properly address the margin of safety.

Although the issues are resolvable, we do not wish to pursue further action on this issue, at thi.s time.

We regret and apologize for any inconvenience we may have caused.

Kenneth W Berry Director, Nuclear Licensing CC Administ~~~9~, ~egion III, NRC NRC Resident Inspector - Palisades 1~~003oo:3i4

  • 00000002 25 5-5

~.

\\

1 1

\\

~DR \\ADOCK 05 PN~.

~-1,

I

~-

OC0888-0103-NL02