Responds to NRC Bulletin 87-002,Suppls 1 & 2 Re Fastner Testing to Determine Conformance W/Applicable Matl Specs. Review of Purchase Orders Did Not Include Receipt/Receipt Insp or Installation Records to Determine Items Used
ML18053A456
Person / Time
Site: Palisades 
Issue date: 07/20/1988
From: Berry K
CONSUMERS ENERGY CO. (FORMERLY CONSUMERS POWER CO.)
To:
NRC OFFICE OF ADMINISTRATION & RESOURCES MANAGEMENT (ARM)
References
IEB-87-002, IEB-87-2, NUDOCS 8807280387
Download: ML18053A456 (44)


Text

consumers Power l'aWERIN&

MICHlliAN'S PIUlliRESS General Offices:

1945 West Parnell Road, Jackson. Ml 49201 * (517) 788-1636 July 20, 1988 Nuclear Regulatory Commission Document Control Desk Washington, DC 20555 DOCKET 50-255 - LICENSE DPR PALISADES PLANT -

Kenneth W Berry Director Nuclear Licensing RESPONSE TO NRC BULLETIN 87-02 SUPPLEMENTS 1 & 2 - FASTENER TESTING TO DETERMINE CONFORMANCE WITH APPLICABLE MATERIAL SPECIFICATIONS NRC Bulletin 87-02 Supplement 1 requested information on the procurement of fasteners within the past 10 years.

Supplement 2 revised the "action required" to clarify the intent and limit the request.to ferrous fasteners !-inch in diameter or greater.

At the time of receipt of Supplement 2, the requested action of Supplement 1 was completed.

We therefore, are providing. the inform-ation as originally requested in Supplement 1 which also fulfills the request in Supplement 2.

A review was made of all Consumers Power Company purchase orders placed for Palisades over a 10 year period (March, 1978 through May, 1988).

Each purchase order specifically referring to fasteners, was sorted by supplier name and address and a summary was made of the orders.

There were 187 different suppliers (some were the same supplier with different addresses), 82 of which supplied safety related (Q) or commercial grade items (CQ) intended for use in safety related applications.

The summary (attached) includes a separate column for non-safety related material (NQ).

The summary does not indicate the number of purchase orders or the quantities ordered.

The total number of purchase orders to each supplier was between 1 and 33 and many were suppliers for only 1 or 2 purchases.

The review did not include receipt/receipt inspection records or installation records to determine which items were actually received or used, nor did it consider equipment suppliers and contractors whose equipment or work included fasteners being supplied.

Kenneth W Berry Director, Nuclear Licensing CC Administrator, Region III, NRC NRC Resident Inspector - Palisades Attachment OC0788-0064-NL02 8807280387 880720 PDR ADOCK 05000255 Q

PDC A1

'/P,,I

CONSUMERS POWER COMPANY Palisades Plant Docket 50-255 - License DPR-20 RESPONSE TO NRG BULLETIN 87-02 SUPPLEMENTS 1&2 At the request of the Commission and pursuant to the Atomic Energy Act of 1954 and the Energy Reorganization Act of 1974, as amended, and the Commission's Rules and Regulations thereunder, Consumers Power Company submits our response to NRC Bulletin 87-02 dated 11/6/87, 4/22/88, 6/10/88, entitled, "Fastener Testing to Determine Conformance with Applicable Material Specifications."

Consumers Power Company's response is dated 1/12/88, 1988.

CONSUMERS POWER COMPANY By D~P~9:~ent Nuclear Operations Sworn and subscribed to before me this 20th day of July, 1988.

Beverly n Avery, Not y Public JacKson County, Michigan My commission expires December 27, 1988 OC0788-0064-NL02

COMPANY Accurate Safety Dist.

10320 N. Thor Dr.

Freeland, MI 48603 Action Threaded Products, Inc.

7440 W. lOOth Place Bridgeview, IL 60455 ALCO Power, Inc.

100 Orchard St.

Auburn, NY 13021 AMCO Engineering Company 3801 North Rose St.

Schiller Park, IL 60176 Allis Chambers Hydro, Inc.

P.O. Box M-93 York, PA 17405 Q, CQ Stainless capscrews, nuts; 1/4" to 3/4" (CQ) capscrews and locknuts; vendor part number specified (CQ) nuts;,1 order with vendor part number specified (CQ)

(1987) page 1 of 42 NQ 1 order for nuts for air compressor components.

Vendor part number specifie (1984)

Stainless and brass bolts, capscre~ nu type 18-8 generally specified; l/,.o 7/16"; mainly for motors 1/4" nuts, bolts (1 order -

vendor part numbers specified) (1987) e

COMPANY All Phase Electric Sixth St. & Blue Star Hwy.

South Haven, MI 49090 All State Fastener Corp.

P.O. Box 356 East Detroit, MI 48021 Aloyco, Inc.

1400 W. Elizabeth Linden, NJ 07036 Anchor Darling Valve Company P.O. Box 3428 Williamsport, PA 17701 Argus Supply Company 15975 E. Eleven Mile Rd.

P.O. Box 689 Roseville, MI 48066 Q, CQ valve yoke bushing nut; brass; vendor part number specified (CQ); 1 order -

1985 capscrews -

ASTM A 574 (CQ) nuts, ASTM A479GR316 (Q)

Al94GR2H (Q) bolts AISI 316 (Q) capscrews A 574 (Q)

Studs SA 193 GR B7 (Q) paye 2 of 42 NQ nuts for electrical unistrut/conduic work (1983-1984) nuts; 3/4",

capscrews; stainless 18-8; (1 order -

1981) nuts ordered by catalog ~umber 1/2" -

COMP.Z\\NY Atlas Valve Company.

300 Richardson Dr.

Lancaster, PA 17603 Atwood & Morrill Company 285 Canal St.

Salem, MA 01970 A & G Engineering Company, Inc.

4640 E. Lapalma Ave.

Anahiem, CA 92806 B & L Industrial ~otor 68565 CR 388 South Haven, MI 49090 Q, CQ studs A564 grade nuts A 564 grade studs A 193 87 nuts A 194 2-H 630 {CQ) 630 (CQ)

{CQ)

{CQ) studs SA 193, Grade B-7 {Q) nuts A 194, Grade 2H

{Q) bolts SA 564, Type 630 (Q) page:> 3 of 42 NQ brass nut ordered by catalog number (1 order -

1981) conduit locknuts, connector wire nuts

COMPANY Barnal Fastener Corporation 23240 Industrial Park Dr.

Farmington, MI 48024 Barclay Ayers & Bertsch Company 1655 Steel N.W.

Grand Rapids, MI 49502 Battery Systems Corp.

11940 Brookfield Livonia, MI 48150 Bergen-Paterson Pipe Support 74 Commerce Way P.O. Box 4011

\\-Joburn, MA 01888 Q, CQ locknuts -

ASTM A-304, 1 order -

1987 (CQ) nuts -

catalog order (CQ) bolts -

ASTM A307, Grade B (Q)

U-bolts with nuts, carbon steel, catalog number (CQ)

  • U-bolts SA193 B7, catalog number (Q) nuts ASME SA-36, catalog numbers (Q) page 4 of 42 NQ boltsA-193, Grades BSM, B7 nuts ASME A-194, grade 2H locknuts 316 SS (catalog order) brass bolt -

5/16" nuts-catalog part numbers, A307 U-bolts - catalog part number

COMPANY BIF, A Unit of General Signal C/O Wm. A. Dalee, Inc.

9190 Roselawn Detroit, MI 49224 Bingham-Williamette Company 5725 Dragon Way Cincinnati, OH 45227 Elue Star Glass, Inc.

Rt. #1 Box 428 South Haven, MI 49090 Erammall Supply Company 196-208 Water St.

Benton Harbor, MI 49022 Q, CQ nuts ordered by part number (CQ)

~--

.r page 5 of 42 NQ nuts - stainless 18-8; catalog items capscrews - stainless 18-8; catalog items bolts for doors 1/2" nuts ordered by catalog number

COMPANY Bridgeport Div. Textron 1035 Crooks Rd.

Troy, MI 48084 Byron Jackson Div.

C/O Smith Co.

Northfield Financial Bldg.

900 Tower Dr.

Troy, MI 48098 Byron Jackson Pump Div.

C/O Y. C. Smith Co.

25511 Southfield Rd.

Southfield, MI

~8075 Byron Jackson Pumps Div 2300 E. Vernon Ave.

Vernon, CA 90058 Cardinal Industrial Prod. Corp.

3873 West Oquendo Las Vegas, NV 89118 Q, CQ capscrews ordered by vendor numbei (Q)

(CQ) ; capscrews -

ASTM A-276-TP-304, A-193-GR-B6 (CQ) bolts ordered by vendor number (Q; studs ordered by vendor number (Q' stud-ASTM A-193-GR-B-7 (Q) capscrew -

A-461-GR-660 (Q)

(all Q) nuts-ASME SA-564 _tYl?e 630

-ASTM A307-GR-B

  • ASTM Al94-GR-2H ~nd GR-6

-ASME A-194-GR-8 and GR-BM, Gb-7

  • SA ~79 Type 430 l

'I r*1f"'>

""'I I/\\ I I..__,.

[Jaye 6 of 42 NQ nut/bolt set for milling machine capscrews ordered by drawing nu~

(all Q) studs/rod-ASME SA564 Type 630 bolts-ASME SA-19 3-.. ;;~-88, SS 304 capscrcws-.1\\SME St'\\-1:)3-CR-1:37

COMPANY Carpenter Industrial Supply Co.

P.O. Box 743 Jackson, MI 49201 Carpenter-Paterson 3220 W. 31st St.

Chicago, IL 60623 Cincinnati Milacron, Inc.

28500 Southfield Rd.

Lathrup Village, ~I 48076 C.E. Power Systems Northfield Financial Bldg.

900 Tower Dr.

Troy, MI 48098 Comsip, Inc.

3030 Red Hat Lane Whittier, CA 90601 Q, CQ bolts-ASME SA 564 Type 630 (Q,CQ~

ASTM A 193 B-7 (Q) nuts Al82 GR F-347 (Q)

ASTM A 415, 304 SS (CQ)

ASTM A 194 GR 7, GR 2-H (Q)

ASTM A 193 GR B~7 (Q) studs ASTM A 540 GR B-24 (Q) capscrews ASTM A 193-B-8-M (Q) set screws ASME SA 193 GR 8*16

(~)

nuts -

SS ordered By part number (Q) pdge 7 of 42 NQ locknuts -

SS 18-8 nuts - catalog number U-bolts - catalog number

~

nuts, screws, bolts for a lathe capscrews -

304SS locknuts ordered to drawing number bolts ordered to drawing number nuts -

ASME SA194 GR 4 (Q)

cmlPANY Consolidated Pipe & Valve Supply 1210 N. Willow St.

Mishawaka, IN 46544 Construction Fasteners, Inc.

2120 Kansas Avenue Flint, MI 48506 Coon-Devisser Company 1500 N. Stephenson Royal Oak, MI 48067 Cooper Energy Services Pen Pump Plant P.O. Box 389 Northwood Avenue Eastron, Pa 18042 Copes-Vulcan, Inc.

P.O. Box 577 Lake Cit;, PA 164~3 Q, cg nuts ASTM A-108 (CQ)

U-bolt/nuts, orderej by catalog number (CQ) studs ASTM.?.\\ 193 G~ '87 (CQ) capscrews ordered b~' dfawing nurc.ber (CQ) n~~s AST~ ~ 194 G~ : H (C~)

page 8 of 42 NQ nuts ordered by catJlog number stu=, ordered by catalog number setscrews and nuts ordered by cataloy num:i2r

I CO~ANY Q, CQ Core Electric/Michigan Pump, Inc.

25125 Outer Dr.

Melvindale, MI 48122 Crane Aloyco, Inc.

nuts SS 304 (Q) 12 E. Devonwood Romeoville, IL 60441 Crane Company Chapman Div.

203 Hampshire St.

Indian Orchard, MA 01151 Crosby Valve Div. Geosource, Inc.

43 Kendrick St.

Wrentham, MA 02093 nuts and studs ordered by drawing number (Q) nuts ordered by part number (CQJ pa':Je 9 of 42 NQ nuts ordered by part number nuts SS 304

COMPANY Cummins Michigan, Inc.

3715 Clay, S.W.

Grand Rapids, MI 49509 Custodis/Ecodyne C/O Bradbury Kenrick Assoc.

P.O. Box 2000 Rochester, MI 48063 Custodis-Ecodyne, Inc.

37 W. 222 Rt. 64 Suite 256 B-8015 Mercantile Plaza St. Charles, IL 60174 Delta Unibus Cl? Engel Klaes Co.

P.O. Box 281 Southfield, Ml 48037 Depatie Fluid Power Co., Inc.

P.O. Box 2556 Kalamazoo, MI 49003 Q, CQ capscrews ordered by part number (CQ) page 10 of 42 NQ nuts ordered by catalog items bolts, nuts - stainless nuts and bolts by drawing number nuts 316 SS

COMPANY Detroit Ball Bearing 1301 N. Madison Ave.

Bay City, MI 48706 Detroit Ball Bearing 1948 Plaza Dr.

Co.

Benton Harbor, MI 48022 Dionex 250 E. Devon Avenue Suite 160 Itasca, IL 60143 Dionex 1228 Titan Way Sunnyvale, CA 94086 Dresser Industries, Inc.

302 S. Center St.

Springfiled, OH 45501 Q, CQ locknuts by drawing number (Q and CQ)

~uts'by part number (Q) page 11 of '-12 NQ locknut by part number locknuts by drawing number bolts by catalog number bolts by catalog number

COMPANY Ecodyne Cooling Products Div.

79 W. Monroe Chicago, IL 60603 Ecodyne Cooling Products C/O Bradbury Kenrick Assoc., Inc.

P.O. Box 2000 Rochester, MI 48063 Ecodyne Cooling Products Div.

C/O Bradbury Kenrick P.O. Box 597 Oak Ridge Station Royal Oak, MI 48073 Electric Machinery Mfg. Co.

800 Central Ave.

Minneapolis, MN 55413 Elliott Company Donora Industrial Park Scott St. Extension Jonora, PA 15033 pagl~ 12 of 42 Q, CQ NQ bolts bolts by reference to components ~

bolts, nuts by part numbers studs by part number (CQ)

~

studs, nuts, capscrews by catalog number (CQ)

COMPANY Energy Steel & Supply Co.

2715 Paldan Dr.

Auburn Hills, MI 48057 Energy Steel Supply 1681 W. Hamlin Rd.

Rochester, MI 48063 Engelwood Electrical Supply 2503 E. Michigan Ave.

Jackson, MI 49204 Esterline Angus Inst. Corp.

P.O. Box 24000 Indianapolis, IN.

46224 Exotic Rubber & Plastics P.O. Box 234 Jackson, MI 49204-0234 Q, CQ bolts-ASTM A307 GR-A (CQ) nuts-stainless (CQ}

-ASTM 307 GR-A (CQ}

-ASME SA 194 GR-8, 304 SS (Q) capscrews-ASTM A-193 (CQ}

studs-ordered by drawing (Q) threaded rod-ASTM A-36 (CQ}

nuts-ASTM A-194 GR-SM (CQ}

GR-2H (Q}

-ASME SA 564 Type 630 (Q}

-ASME SA-453 GR 660 (Q}

capscrews-carbon steel grade 5 (C }

studs-SA 193 GR B-7 (Q) pdye 13 of 42 NQ nuts for conduit ordered by catalog wirenuts ordered by catalog bolts, nuts, studs ordered by cat~J nuts ordered by catalog number, some stainless

COMPANY J. N Fauver Company P.O. Box 9374 318 Mart St.

Grand Rapids, MI 49508 Fauver Co. Inc.

P.O. Box 320 Kentwood, MI 49508 Fischer & Porter ATTN:

Lori Hardy 28820 Southfield Rd.

Suite 221 Lathrup Village, MI 48076

?itzpatrick Electric & Supply 444 Irwin Ave.

~uskegon, MI 49443 Q, CQ puye 14 of 42 NQ nuts for a catalog item nuts for a catalog item stud ordered by part number wirenuts ordered by catalog

COMP.l\\NY General Fastners Co.

1200 Globe Rd.

Livonia, MI 48150 Gimpel Machine Works, Inc.

250 N. Woodbourne Rd.

Langhorne, PA 19047 Goulds Pumps, Inc.

30600 Telegraph Rd.

Suite 3222 Birmingham, MI 48010 Goulds Pumps, Inc.

28437 Greenfield Rd.

Southfield Rd.

Southfield, MI 48076 Q, CQ nut -

reference to component model (CQ) pa*Je 15 of 42 NQ nuts-ASTM A307 GR B A563 CR A bolts-ASTM A 307 GR B capscrews-stainless capscrews-reference to drawing number studs.- reference to drawing number nuts~* reference to drawing number nuts- *reference to component model

CC:-l.PANY Goulds Pumps, Inc.

C/O Simon Inc.

7700 Sprinkle Rd.

Kalamazoo, MI 49001 Grand Rapids Valve & Fitting Co.

7780 Clyde Park, S.W.

Byron Center, MI 49315 Greif Brothers Corporation 346 Goodell St.

Wyandotte, MI 48192 pay8 16 of 42 Q, CQ NQ nuts -

reference to component model (CQ) studs -

ASTM A-108 GR 1211 (CQ)

Nuts-316 SS Swaglock (Q, CQ)

-catalog number (Q, CQ)

-ASME SA-403 Type WP 316 (Q) nuts - brass Swaglock-402-1

-ss-1212-1, 1012-1

  • catalog number nuts and bolts for 55 gallon drums

COMP]l~I'!

Fluid Connections, Inc.

P.O. Box 1721 Grand Rapids, MI 49501 GCA Corp.

899 w. Highway 96 St. Paul, MN 55126 GCA Corp./PAR Systems 3460 Lexington ~ve., N.

St. Paul, MN 55112 The Gage Compar:y Jackson Division 730 E. Mansion Jackson, MI 49203 Q, C'.2 capscrews, stainless (CQ) capscrews -

818.3-1976 (Q,CQ) nuts-818.3-1976 (CQ)

-stainless 818.2.2 -

1972 (Q) page 17 of 42 bolts ordered by reference to component model bolt ordered by reference to component model

COMPANY Guard Nut A Division of Rally Enterprises, Inc.

Box 299 Sonoma, CA 95476 H & K Fasteners P.O. Box 1467 Traverse City, MI 49685 pdye 18 of 42 Q, CQ NQ nuts ordered by part number capscrews - stainless type 18-8 Hach Company nuts ordered by part number P.O. Box 389 Loveland, CO 80539 Hach Company nuts ordered by part number P.O. Box 907 Ames, IA 50010

COMPANY Hammel Dahl & Jamesbury Controls 175 Post Rd.

Warwick, RI 02888 Harbor Welding Supply Co.

2320 Meadowbrook Rd.

Benton Harbor, MI 49022 John T. Harley Co.

23800 Industrial Park Dr.

Farmington Hills, MI 48204 Henry Vogt Machine Corp.

P.O. Box 1918 Louisville, KY 40201 Q, CQ nuts by reference to component serial numbers (CQ) page 19 of 42 NQ nuts by reference to catalog number capscrews by reference to part numl.Jer nuts by reference to component serial numbers nuts by reference to part number

COMPANY

-!ilti, Inc.

21321 Hilltop Southfield, MI 48034

-:ilti Inc.

?.O. Box 21148 Tulsa, OK 74121

-:ilti Fastening Systems 37473 Schoolcraft Rd.

~ivonia, MI 48150 C:ilti, Inc. Fasteneing Systems 520 Hilton Rd.

?erndale, MI 48220 C:ilti Fastening Systems

?5 W. Webster St.

~~skegon, MI 49440 Q, CQ anchor bolts-stainless, catalog number (CQ) anchor bolts-catalog number (CQ) anchor bolts - stainless, catalog number (CQ) pa<Je 20 of 42 NQ stud anchors ordered by catalog number anchor bolts - ordered by catalog number anchor bolts - ordered by catalog ~er anchor colts -

ordered by cataloy nurnb,~r

COMPANY Hilti Inc.

3322 Lousrna Dr.

Suite 403 Grand Rapids, MI 49508 Hilti Inc.

Attn: D. Heisler 2618 E. Shore Dr.

Kalamazoo, MI 49002 Hitachi America Ltd 11 Greenway Plaza, Suite 2206 Houston, TX 77046 Honeywell, Inc.

900 Ionia Ave. N.W.

Grand Rapids, MI 49503 Honeywell 23938 Research Dr.

Farmington Hills, MI 48018 Q, CQ anchor bolts -

catalog number, some stainless (CQ) anchor bolts -

stainless, catalog number (CQ) capscrews by part number (CQ) paye 21 of 42 NQ anchor bolts -

catalog number nuts and bolts by part number studs and nuts by part number

page 22 of 42 Q, CQ COMPANY NQ IMC Magnetics bolts by part number 570 Main St.

West Bury, Long Island, NY 11590 Industrial Belting & Supply Co.

1211 Fulford St.

Kalamazoo, MI 49003 Ingersol-Rand Co.

C/O Pump Parts Order Service 888 Industrial Dr.

Elmhurst, IL 60126 ITT Grinnel Corp.

21755 Trolley Industrial Dr.

Taylor, MI 48180 J.A. Sexauer Mfg. Co., Inc.

C/O Wally Wrench P.O. Box 842 Court Sta.

Kalamazoo, MI 49005 nuts -

300 SS by drawing number (Q, CQ) by drawing number (Q,CQ) screws -

by drawing number (Q,CQ)

U-bolts -

SA 193 GR B7 (CQ)

- catalog number (Q) nuts -

SA 194 GR 2H (CQ) catalog number (Q) nuts by part number nuts by part number

page 23 of 42 COMPANY Q, CQ NQ J.A. Sexauer, inc.

nuts by part number 10 Hamilton Ave.

White Plains, NY 10601 J.E. Lonergan Co.

C/O Agren-Ascher Co.

20100 Van Dyke Ave.

Warren, MI 48093 Jennsion Hardware Co.

901 N. Water St.

Bay City, MI 48706 Joliet Valves, Inc.

P.O. Box 400 Ridge Road Minooka, IL 60477 K & D Select Fasteners, Inc.

2457 American Lane Elk Grove Village, IL 60007 nuts by drawing number nuts - steel threaded rod -

carbon steel class 2A nuts by reference to components capscrews - silicon bronze (CQ)

COMPANY Q, CQ K & M Industrial Machinery Co.

530 W. Kalamazoo Ave.

Kalamazoo, MI 49007 Kalamazoo Mill Supply Company 1830 Lake St.

Kalamazo, MI 49001 Kelm Mfg.

Rt #3 Box 166 Benton Harbor, MI 49022 Kendall Industrial Supply 702 N. 20th St.

Battle Creek, MI 49016 Kendall Industrial Supply Co.

1286 Pipestone Benton Harbor, MI 49022 nuts - per drawing (Q)

  • studs -

ASTM A-564 ClR 630 (Q) page 24 of 42 NQ nut -

reference to catalog number bolts bolts - per drawing, some stainless nuts stainless 18-8 nuts per catalog number nut$ - carbon steel, stainless bolts -

carbon steel1 some by catalog number capscrews -

carbon steel grade 2 1 stainless

COMPANY Q, CQ Kerotest Manufacturing Corp.

2525 Liberty Ave.

Pittsburgh, PA 15222 Kieley & Mueller, Inc.

C/O Automatic Controls Co.

19115 W. Eight Mile Rd.

Detroit, MI 48219 Kilbourn Engineering Co.

9226 W. Flagg Ave.

Milwaukee, WI 53225 Layne Northern Co.

P.O. Box 468 Mishawaka, IN 56544 Lake Welding Supply Co.

363 Ottawa St.

Muskegon, MI 49440 threaded rod -

ASME SA 564 type 630 (Q)

ASTM A 193 GR 87 ( )

nuts -

ASTM A194 (Q)

ASME SA 564 type 630 (Q) bolts by drawing number (Q,CQ) studs -

carbon steel, by drawing number (Q) nuts -

by drawing number, steel (Q,CQ)

M

~ bronze by drawing (CQ)

NQ nut by part number studs by drawing, stainless nuts by drawing, phosphated steel nuts - brass

COMPANY Limitorque Corp.

2730 Bingham Center 20800 Telegraph Brimingham, MI 48010 Limitorque Corp.

5114 Woodall Rd.

P.O. Box 11318 Lynchburg, VA 24502 Mac Whyte Wire Rope Co.

2936 14th Ave.

Kenosha, WI 53141 Q, CQ nuts per component model (Q, CQ) paye 26 of 42 NQ nut per reference to component model nuts and bolts, stainless for wire rope assemblies

COMPANY Mackinaw Engineering 823 W. Saridge St.

Spring Lake, MI 49456 Manufacturers Supply Co.

2851 Buchanan Ave. S.W.

Grand Rapids, MI 49508 Masoeilan Div.

C/O Sample Webtrol, Inc.

35980 Industrial Rd.

Livonia, MI 48150 Mason Neilan Dresser C/O Sample Webtrol, Inc.

25980 Industrial Rd.

Livonia, MI 48150 Q, CQ bolts by part number (CQ) nuts by part number (CQ) bolts by part number (CQ) nuts by part number (CQ) page 27 of 42 NQ nuts by part number bolts -

carbon steel

COMPANY Mc Gowan Electric Supply, Inc.

425 Liberty St.

P.O. Box 765 Jackson, Ml 49204 Mc Master Carr Supply Co.

P.O. Box 4355 2828 N. Paulina Chicago, IL 60680 Metrol Co.

7145 E. Davison Detroit, MI 48212 Michigan Electric Supply Co.

839 Ferguson P.O. Box 977 Benton Harbor, MI 49022 Michigan I & C 23065 Conunerce Dr.

Farmington Hills, Ml 48024 Q, CQ studs for electrical terminals (CQ nuts by part number (CQ)..

pa(Jt:: 28 of 4L NQ nuts by catalog number nuts -

by stock number, some stainless, some silicon bronze U-bolts - stainless by catalog number capscrews - stainless by catalog number bolts by part number nuts - stainless by drawing number AISI 303 nuts by catalog number

- --------~

COMPANY Mid-States Bolt & Screw Co.

2435 S. Grand Traverse St.

Flint, MI 48503 Miller Tool and Die Co.

835 Belden Rd.

Jackson, MI 49203 Mine Safety Appliances Co.

600 Penn Center Bldg.

Pittsburgh, PA 15235 Mittler Supply, Inc.

2320 Meadowbrook Rd.

Benton Harbor, MI 49022 Modulus Corporation Screw & Bolt Division 16000 W. Nine Mile Rd.

Southfield, MI 48075 Q, CQ bolts -

ASTM A-307 (CQ) nuts by part number (CQ) pay8 29 of 42 NQ capscrews - stainless 18-8 nuts - stainless 18-8 nuts - stainless by drawing numbe~

bolts by drawing number nuts by part number nuts by catalog number bolts -

ASTM A 325

COMPANY Mooney Process Engineering, Co.

32700 W. 8 Mile Rd.

Farmington, MI 48024 Motion Industries, Inc.

2025 Yore Ave.

Benton Harbor, MI 49022 Muesco Controls 5450 Old Spanish Trail P.O. Box 14239 Houston, TX 77021 Muskegon Hardware & Supply 605 W. Western Ave.

Muskegon, MI 49443 Nicholson Div. of Datron Inc.

C/O Garrett Burgess Inc.

46901 Grand River P.O. Box 966 Novi, MI 48050 Q, CQ nuts by part number (CQ) nuts by reference to part number (CQ) page 30 of 42 NQ studs - brass by reference to componer1 t model nuts by reference to part number bolts by catalog number screws and nuts by reference to component model

COMPANY North Central Fasteners 544 9th St.

Benton Harbor, MI 49022 North Central Fasteners P.O. Box 840 3515 Lakeshore Dr.

St. Joseph, MI 49085 Nova Machine 18685 Sheldon Rd.

Middleburg, OH 44130 Pacific Pumps Division Dresser Industries 3201 North Wolf Rd.

Franklin Park, MI 60131 Pall Trinity Micro Corp.

P.O. Box 2030 Cortland, NY 13045 Q, CQ capscrews -

A-193 GR B-5, (CQ) stainless, 304 (CQ) bolts -

ASTM A-325 (CQ) nuts -

ASTM A-3.25 (CQ) capscrews - stainless 304

- A-193 GR B-5 nuts -

A-194 GR 2H (CQ)

(CQ)

(CQ) capscrews - stainless 304 (CQ) stainless (CQ)

ASTM A-193 GR B7 {Q)

A-193 GR BS (CQ)

ASME SA-194 GR 8 {Q) nuts - stainless (CQ)

ASME SA 564 type 680 (Q)

ASTM A-194 GR 2H, 6 (Q) paqe 31 of 42 NQ bolts - stainless, carbon steel, A 325 nuts - stainless, carbon steel capscrews - stainless Q, CQ nuts -

ASTM A-453 type 660 (Q)

SA 194 GR 7, 8 (Q)

SA 194 2H (Q) studs -

SA 193 GR 87 (Q)

ASTM A-193 GR 87 {Q)

SA 564 type 630 (Q)

NQ nuti -

by reference to component model bolt -

by part number


~

COMPANY Paramount Tool Co.

Blue Star Hwy. Box 304 Saugatuck, Ml 49453 Paul-Munroe, Inc.

1701 w. Sequoia Orange, CA 92668 Peerless Pump Suite llO 24001 Southfield Rd.

Southfield, MI 48075 Peerless Pump co.

Indian Head Bldg.

21800 Greenfield Rd.

Detroit, MI 48235 Perkin-Elmer Corporation 431 Stephenson Hwy Troy, Ml 48083 Q, CQ page 32 of 42 NQ studs -

ASTM A-193 GR 87 studs with nuts bolts -

grade 87 nuts - stainless 18-8 nuts -

by drawing number nuts -

by drawing number nuts -

by catalog number

COMPANY George R. Peters 1944 Crooks Rd.

Box 850 Troy, MI 48099 William Powell Co.

C/O D.R. Mc Millan 13111 Souix Ave.

Redford, MI 48239 Power & Engineered Products Co.

151 Helen St.

P.O. Box 382 South Plainfield, NY 07080 Pref erred Tool & Products 4817 s. Knox Ave.

Chicago, IL 60632 Process Controls Co.

29915 W. Eight Mile Rd.

Livonia, MI 48152 Q, CQ studs -

A-193 87 (Q) nuts -

A-194 GR 7,8 (Q}

nuts -

by part number (CQ) pc1<Je 33 of 42 NQ studs -

by part number nuts -

by part number nuts, bolts, studs by drawing numb~ or reference to particular use

COMPANY Process Equipment P.O. Box 99 Belding, MI 49043 Programmed & Remote Systems 3460 Lexington Ave., N.

St. Paul, MN 55122 RPM, Inc.

400 36th St. S.E.

Grand Rapids, MI 49508 Rapid Control Eagle Div.

G.W. Mfg. Co.

2479 28th St.

Grand Rapids, MI 49509 Q, CQ capscrews - stainless by part number (CQ)

ASTM A574 (Q) nuts - stainless ANSI Bl8.2.2 (Q)

- stainless by drawing numbe (Q) bolts -

by part number (Q) nuts -

by part number (Q) pi:ll)e 34 of 42

~IQ nuts - stainless 316 bolts - stainless 316 capscrews by part number nuts -

by reference to component model

COMPANY Reliable Automatic Sprinkler 525 North Mac Questen Parkway Mount Vernon, NY 10552 Rockwell International P.O. Box 1961 1900 s. Saunders St.

Raleigh, NC 27602 Safety Services, Inc.

5286 Wynn Rd.

P.O. Box 431 Kalamazoo, MI 49005 Sample-Webtrol, Inc.

32483 Schoolcraft Livonia, MI 48150 Select Fastners, Inc.

65710 Vandustrial Dr.

Westmont, IL 60559 Q, CQ studs -

ASME SA-193 GR 87 (Q) nuts -

ASME SA-194 GR 7 (Q) capscrews -

ASME SA-193 GR 87 (Q) nuts by part number (CQ) capscrews - silicon bronze (CQ) paqe 35 of..J2 NQ nut -

by reference to component mod~l nut by drawing number nuts - reference to component model by part number studs -

by part number nuts -

by part number

COMPANY Simon Inc.

C/O Gould Pumps 4225 W. Main St.

Kalamazoo, MI 49007 Snap-On Tools Corp.

3333 Lousma Dr. S.E.

P.O. Box 8836 Grand Rapids, MI 49508 States Company Attn:

W.C. Wright 4271 Bronze Way Dallas, TX 75237 Steel Center Supply Rt. #1 South Haven, MI 49090 Steel Container Distributors, Inc.

8951 Schaeffer Swy Detroit, MI 48228 Q, CQ nuts - by part number (CQ) nuts - A-563 GR A (CQ)

- carbon steel (CQ)

ASTM A-304 (CQ)

- silicon bronze (CQ) 6061 T-6 (CQ)

ASTM A-194 GR 8 (CQ)

ASTM A-307 (CQ)

U-bol~s - stainless A320 (CQ) carbon steel page 36 of 42 NQ nuts -

L'.' reference to component nuts -

by part number studs -

by part number nuts -

by part number bolts -

ASTM A36 A-325 aluminum 6061-T-6 U-bolts - stainless nuts -

ASTM A-36 Q, CQ bolts -

ASTM A307 (CQ) capscrews - carbon steel (CQ)

NQ capscrews -

by part number

COMPANY Strong Sales 2608 Sanford St.

Muskegon Heights, MI 49444 Strut Service Company Power - Strut Distributor 135 s. Whitford Rd.

Exton, PA 19341 Target Rock Corp.

1966 E. Broadhollow Rd.

P.O. Box V East Farmingdale, NY 11735 Q, CQ studs -

SA-193 GR 86 (CQ) nuts -

SA-194 GR 6 (CQ) nuts by reference to part number (CQ) nuts -

stainless type 300 series (CQ)

NQ

.J i'd(jl' 37 of 42 nuts -

carbon steel A-194 2ll carbon steel yrade 8 bolts -

carbon steel yrade 8 cap9crews - grade 5

COMPANY Harry W. Taylor Co.

5302 Wynn Rd.

Kalamazoo, MI 49003 Teledyne Farris Engineering C/O Metrol Company 7145 East Davison Detroit, MI 48212 Texas Bolt Co.

P. 0. Box 1211 Houston, TX 77001 Q, CQ studs -

ASTM A-193 GR B7 (Q) nuts -

A-194 2H (Q) nuts -

AISI 416 SS, 303 SS (CQ)

ASTM A-582 type 416 SS (CQ) studs -

AISI 416 SS (CQ) nuts - stainless (CQ)

ASTM A-194 GR 2H (Q)

ASTM A-453 type 660 (Q)

ASME SA 453 GR 660 (Q) bolts -

ASTM A-193, GR B-7 (Q,CQ) capscrews -

SA-193 B7 (Q) studs -

SA-193 GR B7 (Q)

SA-453 GR 660 (Q) puge 38 of 42 NQ studs -

A-193 GR 87 nuts -

A-194 GR 2H Bolts -

A-193

COMPANY Threaded Steel Products P.O. Box 3842 Beaumont, TX 77704 Turbodyne Division Dresser Industries, Inc.

37 Coats St.

Wellsville, NY 14895 Underground Pipe & Valve 1100 Prairie Ave.

South Bend, IN 46624 Unistrut Detroit Service Co.

P.O. Box 458 Wayne, MI 48184 Velan Engineering Co.

Avenue C Griswold Industrial Pk Williston, VT 05495 Q, CQ bolts -

by catalog number (CQ) nuts -

by catalog number (CQ) nuts -

A-194 GR 8M (CQ) studs -

ASTM A564 GR 630 (CQ)

NQ studs -

A-193 nuts A-194 page 39 of 42 nuts -

by drawing number by reference to component ~

bolts -

by reference to component nuts nuts by catalog number

COMPANY Victoreen Instrument Co.

10101 Woodland Ave.

Cleveland, OH 44104 Victor Products, Corp.

2635 Belmont Ave.

Chicago, IL 60618 Viking Pump Division Houdaille Industries, 2395 Huron Parkway Ann Arbor, MI 48104 Inc.

Viteo Nuclear Products, Inc.

4445 Hamann Parkway Willoughby, OH 44094 W.J. Woolley Company 1315 W. 22nd St.

Oak Brook, IL 60521 Q, CQ nuts -

by reference to component (CQ) nuts -

ASTM A-194 (Q) bolts -

ASME SA-193 GR B7 (Q) studs -

ASTM A-193 GR B7 (Q)

Studs -

SA-193 GR B7 (Q)

~ ASME SA-564 type 630 (Q)

ASTM A-540 GR B24 (Q) nuts -

ASME SA-194 GR 8 (Q)

~tuds ~ SA-193 B7 (Q) nuts SA 194 GR 2H (Q)

~ciye 40 of 42 NQ capscrews -

by drawing number

COMPANY Walworth Valve Co.

Attn:

J. Hawley 1400 W. Elizabeth Ave.

Linden, NJ 07036 Worthington Group Magraw-Edison Co.

Attn:

Frank Sobeck 37 Coats St.

Wellsville, NY 14895 Westinghouse Electric Corp.

P.O. Box 746 Jackson, MI 49204 Westinghouse Electric 24700 Eleven Mile Rd.

Box 700 Southfield, MI 48076 Y.C. Smith 1715 Northfield Dr.

Rochester, MI 48063 Q, CQ nuts -

A-194 GR BM (CQ) 1 'd'-JL.

~.l U.L NQ nuts -

by part number nuts -

by part number, by drawing, by catalog bronzeJby catalog number capscrews by part number studs -

by drawing, by catalog bolts -

by drawing, by part number e

studs -

by drawing number, by part 11umbc nuts -

by part number, by drawing, cc1ldl bolts -

by ca ta log number, by drawim; nuts -

by drawing

COMPANY York Rubber Company 2921 Venture Dr.

Midland, MI 48640 Q, CQ NQ nuts -

by cataloy number