Enclosure 7 to E-50547 Listing of Computer Files Contained in Enclosure 8 Page 1 of 5 Disk ID No.
(size)
Discipline System/Component File Series (topics)
Number of Files One Computer Hard Drive Total (83.86 GB)
Structural (14.6 GB)
Structural NUHOMS Matrix /
seismic stability evaluation Appendix A.3.9.7 Folder: \\Structural\\Stability\\MaxSliding Maximum sliding case Input and output files for the maximum sliding case (Mianzhuqingping earthquake, =0.4)
(LS-DYNA Evaluation) 12 Appendix A.3.9.7 Folder: \\Structural\\Stability\\MaxRocking Maximum rocking case Input and output files for the maximum rocking case (Tabas earthquake, =0.8)
(LS-DYNA Evaluation) 12 NUHOMS Matrix /
EOS37PTH and EOS89BTH DSCs Structural Analysis in HSM-MX Appendix A.3.9.1 Folder: \\Structural\\DSC\\
Input and output files for the DSC seismic case on the HSM-MX DSC supports (ANSYS Evaluation)
Seismic case (load case 1 in Appendix A.3.9.1.2.7.6) includes:
- 1.5g on the DSC axial direction toward the top of the DSC
- 0.8g on the vertical direction
- 1.6g on the DSC transverse direction
- Dead weight (DSC and basket with fuel)
- Internal pressure of 20 psi 9
NUHOMS Matrix /
Concrete Evaluation Appendix A.3.9.4 Folder: \\Structural\\HSM-MX\\ANSYS Structural analysis for Dead, Live, Seismic, Normal Thermal, and Accident Thermal load cases Input and output files for structural analysis of the HSM-MX concrete structure (ANSYS Evaluation):
- Subfolder dl: Dead load
- Subfolder ll: Live load
- Subfolder ex: Seismic load (1g in X-direction)
- Subfolder ey: Seismic load (1g in Y-direction)
- Subfolder ez: Seismic load (1g in Z-direction)
- Subfolder to: Normal thermal load
- Subfolder ta: Accident thermal load 27 to E-50547 Listing of Computer Files Contained in Enclosure 8 Page 2 of 5 One Computer Hard Drive Total (83.86 GB)
Structural (14.6 GB)
(continued from previous page)
Structural Appendix A.3.9.4 Folder: \\Structural\\HSM-MX\\CivilFEM\\dummy_shell Calculate design forces and moments for Dead, Live, Seismic, Normal Thermal, and Accident Thermal load cases Input and output files for calculating design forces and moments for a front wall top component (Component 6) and an inclined slab component (Component 64) (CivilFEM Evaluation):
- Subfolder dl_dmsh: Component 6 and 64 for dead load
- Subfolder ll_dmsh: Component 6 and 64 for live load
- Subfolder ex_dmsh: Component 64 for seismic load (1g in X-direction)
- Subfolder ey_dmsh: Component 64 for seismic load (1g in Y-direction)
- Subfolder ez_dmsh: Component 64 for seismic load (1g in Z-direction)
- Subfolder to_dmsh: Component 64 for normal thermal load
- Subfolder ta_dmsh: Component 6 for accident thermal load 65 Appendix A.3.9.4 Folder: \\Structural\\HSM-MX\\CivilFEM\\load_comb Design for Seismic and Accident Thermal load combination Input and output files for design of: an inclined slab component (Component 64) for seismic load combination (C4); and a front wall top component (Component 6) for accident thermal load combination (C7).
(CivilFEM Evaluation)
- Subfolder lc4: Component 64 for seismic load combination (C4)
- Subfolder lc7: Component 6 for accident thermal load combination (C7) 26 to E-50547 Listing of Computer Files Contained in Enclosure 8 Page 3 of 5 Disk ID No.
(size)
Discipline System/Component File Series (topics)
Number of Files Enclosure 8 One Computer Hard Drive Total (83.86 GB)
Thermal (67.8 GB)
Thermal NUHOMS EOS-HSM with EOS-37PTH DSC /
Bounding normal hot storage evaluation with HLZC 4 Appendix 4.9.6 (Table 4.9.6-2)
Folder: \\Thermal\\1-EOS-HSM-EOS-37PTH-LC1-Normal-HLZC4 Input and output files for the bounding normal hot storage condition with 8 mph side wind, HLZC 4 (50kW)
(ANSYS FLUENT Evaluation)
Subfolder 0-4500: output files for iterations from 0 to 4500 Subfolder 4501-6500: output files for iterations from 4501 to 6500 28 NUHOMS EOS-TC125 with EOS-37PTH DSC /
Bounding normal transfer evaluation with HLZC 4 Appendix 4.9.6 (Table 4.9.6-4)
Folder: \\Thermal\\2-EOS-TC125-EOS-37PTH-LC1-Normal-HLZC4 Input and output files for the bounding normal hot, indoor transfer condition without air circulation, HLZC 4 (50kW)
(ANSYS FLUENT Evaluation)
Subfolder steady: the steady-state simulation to evaluate initial state for transient simulation Subfolder transient: the transient simulation for 13 hours1.50463e-4 days <br />0.00361 hours <br />2.149471e-5 weeks <br />4.9465e-6 months <br /> 33 NUHOMS MATRIX with EOS-37PTH DSC /
Bounding normal hot storage evaluation with HLZC 7 and coarse mesh Appendix A.4 (Table A.4.2)
Folder: \\Thermal\\3-MATRIX-EOS-37PTH-LC1e-Normal-HLZC7-Coarse Input and output files for the bounding normal hot storage condition with 15 mph side wind, HLZC 7, and coarse mesh (ANSYS FLUENT Evaluation)
Subfolder 0-6000: output files for iterations from 0 to 6000 Subfolder 6001-12000: output files for iterations from 6001 to 12000 43 NUHOMS MATRIX with EOS-37PTH DSC /
Bounding normal hot storage evaluation with HLZC 7 and fine mesh Appendix A.4 (Table A.4.2)
Folder: \\Thermal\\4-MATRIX-EOS-37PTH-LC1f-Normal-HLZC7-Fine Input and output files for the bounding normal hot storage condition with 15 mph side wind, HLZC 7, and fine mesh (ANSYS FLUENT Evaluation)
Subfolder 0-6000: output files for iterations from 0 to 6000 Subfolder 6001-12000: output files for iterations from 6001 to 12000 43 to E-50547 Listing of Computer Files Contained in Enclosure 8 Page 4 of 5 Disk ID No.
(size)
Discipline System/ Component File Series (topics)
Number of Files One Computer Hard Drive Total (83.86 GB)
Shielding (1.45 GB)
Shielding NUHOMS EOS-37PTH DSC UFSAR Section 6.2.2 PWR and BWR Source Terms 001 Source Specification - Folder Source terms for PWR HLZC#4, Zones 2 and 3 10 002 Shielding Analysis - Folder N/A NUHOMS EOS-125/135 UFSAR Section 6.4.3 EOS-TC Dose Rates 002.01 TC125 - Folder EOS-TC125/135 dose rates for the 37PTH DSC HLZC#4 N/A 002.01.01 Transfer - Folder 6
002.01.02 Decon - Folder 6
002.01.03 Welding - Folder 6
002.01.04 Accident - Folder 4
NUHOMS EOS-HSM UFSAR Section 6.4.4 EOS-HSM Dose Rates 002.02 EOS-HSM - Folder EOS-HSM dose rates for the 37PTH DSC HLZC#4 6
NUHOMS MATRIX Appendix A.6.4.4 HSM-MX Dose Rates 002.03 HSM-MX - Folder HSM-MX dose rates N/A 002.03.01 Single Ref - Folder 7
002.03.02 Double Ref - Folder 7
002.03.03 Triple Ref - Folder 7
002.03.04 Door - Folder 7
002.03.05 Accident - Folder 8
NUHOMS MATRIX Appendix A.11.3 Offside Dose Calculations 003 Offsite Dose Calculations - Folder N/A 003.01 2_1x11 - Folder 6
003.02 2x11 - Folder 6
003.03 2x11 Accident - Folder 6
Spreadsheet describing each input and output file 1
to E-50547 Listing of Computer Files Contained in Enclosure 8 Page 5 of 5 Disk ID No.
(size)
Discipline System/Component File Series (topics)
Number of Files One Computer Hard Drive Total (83.86 GB)
Criticality (6.09 MB)
Criticality NUHOMS-EOS37PTH Criticality Analysis Criticality - Folder 10 Damaged-Failed(no RSB) - Folder The folder supports Chapter 7.
Input and output files for various maximum damaged and failed fuel enrichment requirements as a function of basket type for the EOS-37PTH.
Failed(RSB) - Folder The folder supports Chapter 7.
Input and output files for the maximum BW 15x15 fuel assembly Class reactivity for the loading of 4 Rod Storage Baskets balanced with 33 intact fuels.
2